Small ; 20(32): e2401068, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38477701

RESUMEN

On-the-eye microsystems such as smart contacts for vision correction, health monitoring, drug delivery, and displaying information represent a new emerging class of low-profile (≤ 1 mm) wireless microsystems that conform to the curvature of the eyeball surface. The implementation of suitable low-profile power sources for eye-based microsystems on curved substrates is a major technical challenge addressed in this paper. The fabrication and characterization of a hybrid energy generation unit composed of a flexible silicon solar cell and eye-blinking activated Mg-O2 metal-air harvester capable of sustainably supplying electrical power to smart ocular devices are reported. The encapsulated photovoltaic device provides a DC output with a power density of 42.4 µW cm-2 and 2.5 mW cm-2 under indoor and outdoor lighting conditions, respectively. The eye-blinking activated Mg-air harvester delivers pulsed power output with a maximum power density of 1.3 mW cm-2. A power management circuit with an integrated 11 mF supercapacitor is used to convert the harvesters' pulsed voltages to DC, boost up the voltages, and continuously deliver ≈150 µW at a stable 3.3 V DC output. Uniquely, in contrast to wireless power transfer, the power pack continuously generates electric power and does not require any type of external accessories for operation.

2.
Clin Proteomics ; 21(1): 23, 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38481131

RESUMEN

BACKGROUND: Human tear protein biomarkers are useful for detecting ocular and systemic diseases. Unfortunately, existing tear film sampling methods (Schirmer strip; SS and microcapillary tube; MCT) have significant drawbacks, such as pain, risk of injury, sampling difficulty, and proteomic disparities between methods. Here, we present an alternative tear protein sampling method using soft contact lenses (SCLs). RESULTS: We optimized the SCL protein sampling in vitro and performed in vivo studies in 6 subjects. Using Etafilcon A SCLs and 4M guanidine-HCl for protein removal, we sampled an average of 60 ± 31 µg of protein per eye. We also performed objective and subjective assessments of all sampling methods. Signs of irritation post-sampling were observed with SS but not with MCT and SCLs. Proteomic analysis by mass spectrometry (MS) revealed that all sampling methods resulted in the detection of abundant tear proteins. However, smaller subsets of unique and shared proteins were identified, particularly for SS and MCT. Additionally, there was no significant intrasubject variation between MCT and SCL sampling. CONCLUSIONS: These experiments demonstrate that SCLs are an accessible tear-sampling method with the potential to surpass current methods in sampling basal tears.

3.
Ophthalmic Physiol Opt ; 44(2): 321-333, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38303152

RESUMEN

PURPOSE: To measure the dynamic accommodation response (AR) to step stimuli with and without multifocal contact lenses (MFCLs), in emmetropes and myopes. METHODS: Twenty-two adult subjects viewed alternating distance (0.25D) and near (3D) Maltese crosses placed in free space, through two contact lens types: single vision (SVCL) or centre-distance multifocal (MFCL; +2.50D add). The AR level was measured along with near to far (N-F) and far to near (F-N) step response characteristics: percentage of correct responses, magnitude, latency, peak velocity and duration of step response. RESULTS: There was no difference between N-F and F-N responses, or between refractive groups in any aspect of the accommodation step response dynamics. The percentage of correct responses was unaffected by contact lens type. Through MFCLs, subjects demonstrated smaller magnitude, longer latency, shorter duration and slower peak velocity steps than through SVCLs. When viewing the near target, the AR through MFCLs was significantly lower than through SVCLs. When viewing the distance target with the MFCL, the focal points from rays travelling through the distance and near zones were approximately 0.004D behind and 2.50D in front of the retina, respectively. When viewing the near target, the respective values were approximately 1.89D behind and 0.61D in front of the retina. CONCLUSION: The defocus error required for accommodation control appears not to be solely derived from the distance zone of the MFCL. This results in reduced performance in response to abruptly changing vergence stimuli; however, these errors were small and unlikely to impact everyday visual tasks. There was a decrease in ocular accommodation during near tasks, which has previously been correlated with a reduced myopic treatment response through these lenses. With MFCLs, the estimated dioptric myopic defocus was the largest when viewing a distant stimulus, supporting the hypothesis that the outdoors provides a beneficial visual environment to reduce myopia progression.


Asunto(s)
Lentes de Contacto Hidrofílicos , Lentes de Contacto , Miopía , Adulto , Humanos , Refracción Ocular , Pruebas de Visión , Emetropía , Acomodación Ocular , Miopía/terapia
4.
Ophthalmic Physiol Opt ; 44(4): 774-786, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38578134

RESUMEN

PURPOSE: To investigate gaze and behavioural metrics at different viewing distances with multifocal contact lenses (MFCLs), single vision contact lenses (SVCLs) and progressive addition lenses (PALs). METHODS: Fifteen presbyopic contact lens wearers participated over five separate study visits. At each visit, participants were randomly assigned to wear one of five refractive corrections: habitual PAL spectacles, delefilcon A (Alcon Inc.) MFCLs and three separate pairs of delefilcon A single vision lenses worn as distance, intermediate and near corrections. Participants wore a Pupil Core headset to record eye and head movements while performing three visual tasks: reading, visual search and scene observation. Data were investigated using linear regression and post-hoc testing. Parameters of interest included gaze (fixation duration, head movement) and behavioural (reading speed, reading accuracy, visual search time) metrics. RESULTS: Reading speed in SVCLs was significantly faster than in MFCLs and PAL spectacles (F = 16.3, p < 0.0001). Refractive correction worn did not influence visual search times (F = 0.16, p = 0.85). Fixation duration was significantly affected by the type of visual task (F = 60.2, p < 0.001), and an interaction effect was observed between viewing distance and refractive correction (F = 4.3, p = 0.002). There was significantly more horizontal and vertical head movement (F = 3.2, p = 0.01 and F = 3.3, p = 0.01, respectively) during visual search tasks when wearing PAL spectacles compared to SVCLs or MFCLs. CONCLUSION: This work showed that the type of refractive correction affects behavioural metrics such as reading speed and gaze behaviour by affecting horizontal and vertical head movements. The findings of this study suggest that under certain conditions, wearers of MFCLs make fewer head movements compared to PAL spectacles. Gaze behaviour metrics offer a new approach to compare and understand contact lens and spectacle performance, with potential applications including peripheral optical designs for myopia management.


Asunto(s)
Lentes de Contacto , Anteojos , Fijación Ocular , Presbiopía , Lectura , Refracción Ocular , Agudeza Visual , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimientos Oculares/fisiología , Fijación Ocular/fisiología , Movimientos de la Cabeza/fisiología , Presbiopía/fisiopatología , Presbiopía/terapia , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Estudios Cruzados , Estudios Prospectivos
5.
Ophthalmic Physiol Opt ; 44(4): 737-745, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38217323

RESUMEN

PURPOSE: To evaluate the relative positions of modern soft contact lenses (SCLs) relative to the limbus/cornea and the pupil. METHODS: Sixty images of the anterior eyes of 101 subjects were acquired over 10 s while participants fixated the centre of the camera lens located 33 cm in front of the eye in a well-lit (300 lux) clinic. Custom validated image analysis software was used to locate the boundaries of the contact lenses, pupils and corneas (limbus). Horizontal and vertical relative positions of the contact lens, pupil and limbus were calculated from the fitted boundaries. RESULTS: The mean (standard deviation) pupil and corneal diameters for all subjects were 3.84 mm, (0.83) and 11.97 mm (0.48), respectively. The mean [95% confidence interval] pupil centre was located 0.28 mm [0.26, 0.30] nasally and 0.07 mm [0.05, 0.10] superiorly to the corneal centre. Consistent with clinical observations, the contact lenses centred accurately relative to the corneal centre both nasally 0.04 mm [0.01, 0.07] and inferiorly -0.01 mm [-0.06, 0.03]. However, regardless of the eye, the contact lens was significantly (p < 0.001) decentred relative to the pupil centre both temporally -0.23 mm [-0.26, -0.20] and inferiorly -0.08 mm [-0.12, -0.04]. Decentration magnitudes were significantly correlated between the right and left eyes. CONCLUSIONS: Spherical SCLs centred well on the cornea but temporally and inferiorly from the primary line of sight (pupil centre), due to the differences in the location of the pupil and corneal centres. Contrary to some previous reports, there was no evidence that lens optics or material affected lens centration significantly.


Asunto(s)
Lentes de Contacto Hidrofílicos , Pupila , Humanos , Masculino , Adulto , Femenino , Pupila/fisiología , Adulto Joven , Córnea/diagnóstico por imagen , Córnea/anatomía & histología , Persona de Mediana Edad , Adolescente
6.
Ophthalmic Physiol Opt ; 44(5): 884-893, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38778634

RESUMEN

INTRODUCTION: Soft contact lenses may be a good alternative for early-stage keratoconus (KC) patients who do not tolerate rigid gas permeable (RGP) lenses due to ocular discomfort or complications. This prospective study compared outcomes obtained after 2 weeks of wearing two types of soft silicone hydrogel contact lenses for keratoconus that varied in their diameter and central thickness (cc). METHODS: Patients with Amsler-Krumeich grades I or II KC were fitted with small-diameter (14.2 or 14.8 mm) SoftK (SD-SoftK, cc = 0.48 mm) and large-diameter (17 mm) SoftK (LD-SoftK, cc = 0.60 mm) lenses, each worn for 2 weeks in a crossover design. Low (10%;10VA) and high (100%;100VA) contrast visual acuity, contrast sensitivity (CS, Pelli-Robson), higher order aberrations (HOAs, Visionix Vx130), the number of trial lens modifications during fitting and the subjectively preferred lens were compared using Friedman tests with post-hoc analysis. RESULTS: Forty eyes (N = 20, 10 males, mean age: 39.0 ± 9.9 years, range: 23-55 years) were examined. Their habitual median (interquartile1, interquartile3) 10VA (LogMAR), 100VA (LogMAR) and CS (LogCS) were 0.52 (0.30, 0.50), 0.14 (0.10, 0.15) and 1.35 (1.35, 1.50), respectively. For the SD-SoftK condition, the values were 0.23 (0.17, 0.30), 0.02 (0.00, 0.05) and 1.50 (1.50, 1.65), respectively. For the LD-SoftK condition, the respective values were 0.36 (0.27, 0.44), 0.09 (0.05, 0.13) and 1.50 (1.50, 1.60). SD-SoftK lenses significantly improved 10VA compared with habitual and LD-SoftK. SD-SoftK also significantly improved CS compared with habitual, but not LD-SoftK. LD-SoftK significantly improved spherical aberration compared with uncorrected (0.03 ± 0.10 µ vs. 0.07 ± 0.13 µ) but not SD-SoftK (0.04 ± 0.07 µ). Both lenses required a mean of 1.5 modifications prior to final lens fitting. Fewer adverse events were seen with SD-SoftK (N = 3) compared with LD-SoftK (N = 8), and 75% of participants preferred SD-SoftK lenses. CONCLUSION: SD-SoftK lenses were preferred by 75% of subjects, were associated with fewer adverse events and significantly improved 10VA compared with LD-SoftK lenses. SD-SoftK lenses also significantly improved CS compared with the habitual correction, but this did not differ significantly from the LD-SoftK lenses.


Asunto(s)
Lentes de Contacto Hidrofílicos , Sensibilidad de Contraste , Topografía de la Córnea , Estudios Cruzados , Queratocono , Agudeza Visual , Humanos , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Masculino , Femenino , Estudios Prospectivos , Adulto , Agudeza Visual/fisiología , Adulto Joven , Sensibilidad de Contraste/fisiología , Topografía de la Córnea/métodos , Persona de Mediana Edad , Diseño de Equipo , Refracción Ocular/fisiología
7.
Ophthalmic Physiol Opt ; 44(2): 301-310, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37984831

RESUMEN

PURPOSE: Limitations of existing diffractive multifocal designs for presbyopia correction include discrete foci and photic phenomena such as halos and glare. This study aimed to explore a methodology for developing refractive extended depth-of-focus (EDoF) lenses based on a periodic power profile. METHODS: The proposed design technique employed an optical power profile that periodically alternated between far, intermediate and near distances across the pupil radius. To evaluate the lens designs, optical bench testing was conducted. The impact on visual performance was assessed using a spatial light modulator-based adaptive optics vision simulator in human subjects. Additionally, the effects of pupil size change and lens decentration on retinal image quality were examined. A comparative performance analysis was carried out against a typical diffractive trifocal design and a monofocal lens. RESULTS: The proposed design method was found to be effective in uniformly distributing light energy across all object distances within the desired depth of focus (DoF). While trade-offs between overall image quality and DoF still exist, the EDoF lens design, when tested in human subjects, provided a continuous DoF spanning over 2.25 D. The results also revealed that the EDoF design had a slightly higher dependence on changes in pupil size and lens decentration than the diffractive trifocal design. CONCLUSION: The proposed design method showed significant potential as an approach for developing refractive EDoF ophthalmic lenses. These lenses offer a continuous DoF but are slightly more susceptible to variations in pupil size and decentration compared with the diffractive trifocal design.


Asunto(s)
Lentes Intraoculares , Presbiopía , Humanos , Agudeza Visual , Refracción Ocular , Visión Ocular , Diseño de Prótesis
8.
Ophthalmic Physiol Opt ; 44(1): 153-167, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37962295

RESUMEN

INTRODUCTION: This study investigated the equivocal association between contact lens (CL) wear and meibomian gland dysfunction (MGD) by comparing the morphological, functional and subjective outcomes of CL wearers versus control, non-CL wearers. CL wearers were examined as two cohorts based on the annual attendance of follow-up visits (FLU-attended these visits, whereas non-FLU did not). METHODS: Habitual logMAR visual acuity, invasive and non-invasive tear break-up time, Schirmer test, Efron grading scales, meibum quality score (MQS), meibum expressibility score (MES), meibomian gland (MG) loss, lid margin abnormalities and subjective dry eye (DE) symptoms were assessed. RESULTS: Of the 128 participants, 31 were in the FLU cohort, 43 were in the non-FLU cohort and 54 were controls (mean ages: 22.2 ± 3.1, 23.0 ± 4.6 and 22.3 ± 3.5, respectively). Non-FLU CL wearers had more symptoms than controls (3.7 ± 2.4 vs. 2.3 ± 2.1, p < 0.01). Morphologically, FLU (16.9 ± 8.8%, p = 0.02) and non-FLU (18.6 ± 11.3%, p = 0.001) had more MG loss than controls (11.2 ± 6.8%). Functionally, FLU (0.6 ± 0.7, p = 0.01) and non-FLU (0.8 ± 0.9, p = 0.001) had worse MES than controls (0.2 ± 0.5). FLU and non-FLU were both associated with corneal staining (odds ratio [OR] = 3.42, 95% CI: 1.16-10.11, p = 0.03 and OR = 5.23, 95% CI: 1.89-14.48, p = 0.001, respectively) and MG loss (OR = 10.47, 95% CI: 1.14-96.29, p = 0.04 and OR = 16.63, 95% CI: 1.96-140.86, p = 0.01, respectively). Non-FLU CL wear was also associated with abnormal MQS (OR = 12.87, 95% CI: 1.12-148.41, p = 0.04), conjunctival staining (OR = 12.18, 95% CI: 3.66-40.51, p < 0.001) and lid margin telangiectasia (OR = 3.78, 95% CI: 1.55-9.21, p = 0.003). MGD was three times more prevalent in CL wearers (12%) than in controls (4%). CONCLUSIONS: Both CL-wearing cohorts demonstrated significantly more MG abnormalities than controls though the difference was not clinically significant. Non-FLU CL wearers had more DE symptoms. Non-FLU CL wear is an independent predictor for more abnormalities than FLU CL wear, emphasising the importance of follow-ups.


Asunto(s)
Lentes de Contacto , Síndromes de Ojo Seco , Disfunción de la Glándula de Meibomio , Humanos , Estudios de Seguimiento , Glándulas Tarsales , Conjuntiva , Lágrimas , Síndromes de Ojo Seco/diagnóstico
9.
Ophthalmic Physiol Opt ; 44(1): 199-205, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37897105

RESUMEN

PURPOSE: Accumulated axial growth observed during a 6-year clinical trial of a dual focus myopia control contact lens was used to explore different approaches to assess treatment efficacy. METHODS: Axial length measurements from 170 eyes in a 6-year clinical trial of a dual focus myopia control lens (MiSight 1 day, CooperVision) were analysed. Treatment groups comprised one having undergone 6 years of treatment and the other (the initial control group) having 3 years of treatment after 3 years of wearing a single vision control lens. Efficacy was assessed by comparing accumulated ocular growth during treatment to that expected of untreated myopic and emmetropic eyes. The impact of treatment on delaying axial growth was quantified by comparing the increased time required to reach criterion growths for treated eyes and survivor analysis approaches. RESULTS: When compared to the predicted accumulated growth of untreated eyes, 6 years of treatment reduced growth by 0.52 mm, while 3 years of treatment initiated 3 years later reduced growth by 0.19 mm. Accumulated differences between the growth of treated and untreated myopic eyes ranged between 67% and 52% of the untreated myopic growth, and between 112% and 86% of the predicted difference in growth between untreated myopic and age-matched emmetropic eyes. Treated eyes took almost 4 years longer to reach their final accumulated growth than untreated eyes. Treatment increased the time to reach criterion growths by 2.3-2.7 times. CONCLUSION: Estimated growth of age-matched emmetropic and untreated myopic eyes provided evidence of an accumulated slowing in axial elongation of 0.52 mm over 6 years, and the treated growth remained close to that expected of emmetropic eyes. Six years of dual focus myopia control delayed the time to reach the final growth level by almost 4 years.


Asunto(s)
Lentes de Contacto , Miopía , Humanos , Longitud Axial del Ojo , Ojo , Miopía/prevención & control , Refracción Ocular , Resultado del Tratamiento , Ensayos Clínicos como Asunto
10.
Ophthalmic Physiol Opt ; 44(4): 746-756, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38389207

RESUMEN

PURPOSE: The goal was to use SyntEyes modelling to estimate the allowable alignment error of wavefront-guided rigid contact lens corrections for a range of normal and keratoconic eye aberration structures to keep objectively measured visual image quality at or above average levels of well-corrected normal eyes. Secondary purposes included determining the required radial order of correction, whether increased radial order of the corrections further constrained the allowable alignment error and how alignment constraints vary with keratoconus severity. METHODS: Building on previous work, 20 normal SyntEyes and 20 keratoconic SyntEyes were fitted with optimised wavefront-guided rigid contact lens corrections targeting between three and eight radial orders that drove visual image quality, as measured objectively by the visual Strehl ratio, to near 1 (best possible) over a 5-mm pupil for the aligned position. The resulting wavefront-guided contact lens was then allowed to translate up to ±1 mm in the x- and y-directions and rotate up ±15°. RESULTS: Allowable alignment error changed as a function of the magnitude of aberration structure to be corrected, which depends on keratoconus severity. This alignment error varied only slightly with the radial order of correction above the fourth radial order. To return the keratoconic SyntEyes to average levels of visual image quality depended on maximum anterior corneal curvature (Kmax). Acceptable tolerances for misalignment that returned keratoconic visual image quality to average normal levels varied between 0.29 and 0.63 mm for translation and approximately ±6.5° for rotation, depending on the magnitude of the aberration structure being corrected. CONCLUSIONS: Allowable alignment errors vary as a function of the aberration structure being corrected, the desired goal for visual image quality and as a function of keratoconus severity.


Asunto(s)
Lentes de Contacto , Topografía de la Córnea , Queratocono , Agudeza Visual , Humanos , Queratocono/fisiopatología , Queratocono/diagnóstico , Topografía de la Córnea/métodos , Adulto , Femenino , Masculino , Agudeza Visual/fisiología , Adulto Joven , Aberración de Frente de Onda Corneal/fisiopatología , Aberración de Frente de Onda Corneal/diagnóstico , Refracción Ocular/fisiología , Córnea/diagnóstico por imagen , Córnea/fisiopatología
11.
Ophthalmic Physiol Opt ; 44(5): 876-883, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38712751

RESUMEN

OBJECTIVE: This randomised clinical trial assessed the impact on symptoms, tear film dynamics and ocular surface integrity of daily disposable silicone-hydrogel contact lenses (CLs) over a month, paying special attention to lid wiper epitheliopathy (LWE) and its implications for CL discomfort. METHODS: Neophyte CL wearers (n = 44, 21.09 ± 5.00 years old) were randomly assigned to either the experimental (n = 24) or control group (n = 20). Participants assigned to the experimental group were required to wear daily disposable CLs for 1 month for at least 8 h/day and 6 days/week. All participants were healthy subjects (no history of ocular surgery or active ocular disease) with spherical refractive errors between -8.00 and +5.00 D and cylindrical power <0.75 D. At the baseline and 1-month sessions, the Dry Eye Questionnaire 5 (DEQ-5) was completed, together with the measurement of tear film osmolarity with the TearLab osmometer, tear meniscus height (TMH) and lipid layer pattern (LLP) using a slit-lamp with Tearscope Plus attached, fluorescein break-up time (FBUT), maximum blink interval (MBI), corneal staining with fluorescein under cobalt blue light and LWE with lissamine green under slit lamp and halogen white light. RESULTS: At the baseline session, LWE showed a negative correlation with DEQ-5 (r = -0.37, p = 0.02). Significant differences in FBUT and LWE (p = 0.04) and a positive correlation between LWE and DEQ-5 (r = 0.49, p = 0.007) were observed at 1 month. Intrasession analysis at 1 month showed significant differences between the experimental and control groups in DEQ-5, FBUT and LWE (all p ≤ 0.02). Intersession analysis in the experimental group showed variations in DEQ-5, FBUT and LWE (all p ≤ 0.02) but no significant variation in the control group (all p ≥ 0.11). CONCLUSION: The presence of LWE was significantly correlated with higher symptom values in the DEQ-5. Also, participants in the experimental group presented higher values of LWE after 1 month of CL wear, in comparison with the control group.


Asunto(s)
Lentes de Contacto Hidrofílicos , Equipos Desechables , Síndromes de Ojo Seco , Lágrimas , Humanos , Masculino , Femenino , Lágrimas/fisiología , Lágrimas/metabolismo , Adulto Joven , Síndromes de Ojo Seco/fisiopatología , Síndromes de Ojo Seco/diagnóstico , Adulto , Errores de Refracción/terapia , Errores de Refracción/fisiopatología , Siliconas , Adolescente , Encuestas y Cuestionarios , Enfermedades de los Párpados/fisiopatología , Enfermedades de los Párpados/terapia , Concentración Osmolar
12.
Ophthalmic Physiol Opt ; 44(4): 727-736, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38525850

RESUMEN

PURPOSE: This study addressed the utilisation of machine learning techniques to estimate tear osmolarity, a clinically significant yet challenging parameter to measure accurately. Elevated tear osmolarity has been observed in contact lens wearers and is associated with contact lens-induced dry eye, a common cause of discomfort leading to discontinuation of lens wear. METHODS: The study explored machine learning, regression and classification techniques to predict tear osmolarity using routine clinical parameters. The data set consisted of 175 participants, primarily healthy subjects eligible for soft contact lens wear. Various clinical assessments were performed, including symptom assessment with the Ocular Surface Disease Index and 5-Item Dry Eye Questionnaire (DEQ-5), tear meniscus height (TMH), tear osmolarity, non-invasive keratometric tear film break-up time (NIKBUT), ocular redness, corneal and conjunctival fluorescein staining and Meibomian glands loss. RESULTS: The results revealed that simple linear regression was insufficient for accurate osmolarity prediction. Instead, more advanced regression models achieved a moderate level of predictive power, explaining approximately 32% of the osmolarity variability. Notably, key predictors for osmolarity included NIKBUT, TMH, ocular redness, Meibomian gland coverage and the DEQ-5 questionnaire. In classification tasks, distinguishing between low (<299 mOsmol/L), medium (300-307 mOsmol/L) and high osmolarity (>308 mOsmol/L) levels yielded an accuracy of approximately 80%. Key parameters for classification were similar to those in regression models, emphasising the importance of NIKBUT, TMH, ocular redness, Meibomian glands coverage and the DEQ-5 questionnaire. CONCLUSIONS: This study highlights the potential benefits of integrating machine learning into contact lens research and practice. It suggests the clinical utility of assessing Meibomian glands and NIKBUT in contact lens fitting and follow-up visits. Machine learning models can optimise contact lens prescriptions and aid in early detection of conditions like dry eye, ultimately enhancing ocular health and the contact lens wearing experience.


Asunto(s)
Síndromes de Ojo Seco , Aprendizaje Automático , Lágrimas , Humanos , Concentración Osmolar , Masculino , Femenino , Adulto , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/metabolismo , Persona de Mediana Edad , Adulto Joven , Lentes de Contacto Hidrofílicos/efectos adversos , Encuestas y Cuestionarios
13.
Sensors (Basel) ; 24(11)2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38894283

RESUMEN

Permanent engravings on contact lenses provide information about the manufacturing process and lens positioning when they are placed on the eye. The inspection of their morphological characteristics is important, since they can affect the user's comfort and deposit adhesion. Therefore, an inverted wavefront holoscope (a lensless microscope based on Gabor's principle of in-line digital holography) is explored for the characterization of the permanent marks of soft contact lenses. The device, based on an in-line transmission configuration, uses a partially coherent laser source to illuminate the soft contact lens placed in a cuvette filled with a saline solution for lens preservation. Holograms were recorded on a digital sensor and reconstructed by back propagation to the image plane based on the angular spectrum method. In addition, a phase-retrieval algorithm was used to enhance the quality of the recovered images. The instrument was experimentally validated through a calibration process in terms of spatial resolution and thickness estimation, showing values that perfectly agree with those that were theoretically expected. Finally, phase maps of different engravings for three commercial soft contact lenses were successfully reconstructed, validating the inverted wavefront holoscope as a potential instrument for the characterization of the permanent marks of soft contact lenses. To improve the final image quality of reconstructions, the geometry of lenses should be considered to avoid induced aberration effects.

14.
Int J Mol Sci ; 25(5)2024 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-38473902

RESUMEN

The increase in bacterial resistance to antibiotics in recent years demands innovative strategies for the detection and combating of biofilms, which are notoriously resilient. Biofilms, particularly those on contact lenses, can lead to biofilm-related infections (e.g., conjunctivitis and keratitis), posing a significant risk to patients. Non-destructive and non-contact sensing techniques are essential in addressing this threat. Digital holographic tomography emerges as a promising solution. This allows for the 3D reconstruction of the refractive index distribution in biological samples, enabling label-free visualization and the quantitative analysis of biofilms. This tool provides insight into the dynamics of biofilm formation and maturation on the surface of transparent materials. Applying digital holographic tomography for biofilm examination has the potential to advance our ability to combat the antibiotic bacterial resistance crisis. A recent study focused on characterizing biofilm formation and maturation on six soft contact lens materials (three silicone hydrogels, three hydrogels), with a particular emphasis on Staphylococcus epidermis and Pseudomonas aeruginosa, both common culprits in ocular infections. The results revealed species- and time-dependent variations in the refractive indexes and volumes of biofilms, shedding light on cell dynamics, cell death, and contact lens material-related factors. The use of digital holographic tomography enables the quantitative analysis of biofilm dynamics, providing us with a better understanding and characterization of bacterial biofilms.


Asunto(s)
Biopelículas , Lentes de Contacto Hidrofílicos , Humanos , Bacterias , Antibacterianos , Hidrogeles , Lentes de Contacto Hidrofílicos/microbiología , Pseudomonas aeruginosa/fisiología
15.
Molecules ; 29(11)2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38893485

RESUMEN

The following review focuses on the manufacturing and parameterizing of ocular drug delivery systems (DDS) using polymeric materials to create soft contact lenses. It discusses the types of drugs embedded into contact lenses, the various polymeric materials used in their production, methods for assessing the mechanical properties of polymers, and techniques for studying drug release kinetics. The article also explores strategies for investigating the stability of active substances released from contact lenses. It specifically emphasizes the production of soft contact lenses modified with Cyclosporine A (CyA) for the topical treatment of specific ocular conditions. The review pays attention to methods for monitoring the stability of Cyclosporine A within the discussed DDS, as well as investigating the influence of polymer matrix type on the stability and release of CyA.


Asunto(s)
Ciclosporina , Liberación de Fármacos , Ciclosporina/química , Humanos , Cinética , Sistemas de Liberación de Medicamentos , Lentes de Contacto Hidrofílicos , Estabilidad de Medicamentos , Polímeros/química
16.
Int Ophthalmol ; 44(1): 79, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38351423

RESUMEN

PURPOSE: To compare the outcomes, safety, efficacy, and predictability of microkeratome laser in situ keratomileusis (LASIK) 24 h and one month or more after removing soft contact lenses. SETTING: ULTRALASIK Eye Center, Dubai, United Arab Emirates. METHODS: The patients were divided based on the time of discontinuation of the soft contact lenses before LASIK (Group 1 at 24 h and Group 2 at one month or longer), and the two groups were well matched. Schirmer's testing, tear break-up time, corrected distance visual acuity, uncorrected distance visual acuity, manifest refraction spherical equivalent, and infection rate were evaluated preoperatively and at one week, one month, and six months after treatment. RESULTS: Group 1 (G1) comprised 1025 eyes, and group 2 (G2) had 1052 eyes. The groups were comparable preoperatively. The overall-mentioned outcomes were comparable between groups with uncorrected distance visual acuity of - 0.084 ± 0.12 logMAR in G1 and - 0.078 ± 0.17 logMAR in the G2 at 6 months (P = 0.322). Tear break-up time as well as Schirmer's testing results was also comparable with no evidence of increased risk of dry eyes or non-inflammatory complications in any of the groups on follow-up visits at 1 week (P = 0.421), 1 month (P = 0.101), and 6 months (P = 0.399) postoperatively. Finally, no infectious complications were recorded in either of the groups. CONCLUSION: With the absence of corneal warpage, no statistical or clinical difference in microkeratome LASIK outcomes and safety was spotted between the groups despite the difference in SCL discontinuation time before the procedure.


Asunto(s)
Queratomileusis por Láser In Situ , Miopía , Humanos , Queratomileusis por Láser In Situ/métodos , Miopía/cirugía , Miopía/etiología , Agudeza Visual , Refracción Ocular , Córnea/cirugía , Resultado del Tratamiento , Láseres de Excímeros/uso terapéutico
17.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742501

RESUMEN

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Asunto(s)
Lentes de Contacto , Queratocono , Esclerótica , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Femenino , Masculino , Adulto , Esclerótica/cirugía , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Resultado del Tratamiento , Topografía de la Córnea , Prótesis e Implantes , Adulto Joven , Ajuste de Prótesis/métodos , Adolescente , Sustancia Propia/cirugía
18.
Emerg Infect Dis ; 29(2): 397-401, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36692441

RESUMEN

Tap water is not sterile, and its use in home medical devices can result in infections from waterborne pathogens. However, many participants in a recent survey in the United States said tap water could safely be used for home medical devices. These results can inform communication materials to reduce the high consequence of infections.


Asunto(s)
Percepción , Agua , Humanos , Estados Unidos , Encuestas y Cuestionarios , Abastecimiento de Agua , Microbiología del Agua
19.
Small ; 19(11): e2207017, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36564357

RESUMEN

The contact lens (CL) industry has made great strides in improving CL-wearing experiences. However, a large amount of CL wearers continue to experience ocular dryness, known as contact lens-induced dry eye (CLIDE), stemming from the reduction in tear volume, tear film instability, increased tear osmolarity followed by inflammation and resulting in ocular discomfort and visual disturbances. In this article, to address tear film thinning between the CL and the ocular surface, the concept of using a CL with microchannels to deliver the tears from the pre-lens tear film (PrLTF) to the post-lens ocular surface using in vitro eye-blink motion is investigated. This study reports an eye-blink mimicking system with microfluidic poly(2-hydroxyethyl methacrylate) (poly(HEMA)) hydrogel with integrated microchannels to demonstrate eye-blink assisted flow through microchannels. This in vitro experimental study provides a proof-of-concept result that tear transport from PrLTF to post-lens tear film can be enhanced by an artificial eyelid motion in a pressure range of 0.1-5 kPa (similar to human eyelid pressure) through poly(HEMA) microchannels. Simulation is conducted to support the hypothesis. This work demonstrates the feasibility of developing microfluidic CLs with the potential to help prevent or minimize CLIDE and discomfort by the enhanced transport of pre-lens tears to the post-lens ocular surface.


Asunto(s)
Lentes de Contacto Hidrofílicos , Síndromes de Ojo Seco , Humanos , Microfluídica , Síndromes de Ojo Seco/etiología , Ojo
20.
Exp Eye Res ; 226: 109339, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36470431

RESUMEN

Dry eye disease (DED) is an emerging health problem affecting millions of individuals every year. The current treatments for DED include lubricating eye drops and anti-inflammatory agents. These agents have to be used frequently and contain preservatives, which can damage the ocular surface. A substantially long-acting treatment with better bioavailability on the ocular surface might reduce the frequency of drug use and its side effects. This review summarizes the current state of different biomaterials-nanosystems, hydrogels, and contact lenses used as drug delivery systems in DED. The explored drugs in biomaterial formulation are cyclosporin, ocular lubricants, and topical steroids. Most of the data is from animal models where increased drug delivery and desired therapeutic effects could be obtained; however, trials involving human participants are yet to happen. There is no published study comparing the different types of biomaterials for DED use. Long-term studies evaluating their ocular toxicity and biocompatibility would enhance their transition to human use. Overall they look promising for DED treatment, but they are still in the stage of technological advancement and clinical studies.


Asunto(s)
Lentes de Contacto , Síndromes de Ojo Seco , Animales , Humanos , Síndromes de Ojo Seco/tratamiento farmacológico , Antiinflamatorios/uso terapéutico , Enfermedad Iatrogénica , Disponibilidad Biológica , Lágrimas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA