1.
J Vasc Surg ; 80(1): 45-52, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38336105

RESUMEN

OBJECTIVE: Adverse iliofemoral anatomy may preclude complex endovascular aortic aneurysm repair (EVAR). In our practice, staged iliofemoral endoconduits (ECs) are planned prior to complex EVAR to improve vascular access and decrease operative time while allowing the stented vessel to heal. This study describes the long-term results of iliofemoral ECs prior to complex EVAR. METHODS: Between 2012 and 2023, 59 patients (44% male; median age, 75 ± 6 years) underwent ECs before complex EVAR using self-expanding covered stents (Viabahn). For common femoral artery (CFA) disease, ECs were delivered percutaneously from contralateral femoral access and extended into the CFA to preserve the future access site for stent graft delivery. Internal iliac artery patency was maintained when feasible. During complex EVAR, the EC extended into the CFA was directly accessed and sequentially dilated until it could accommodate the endograft. Technical success was defined as successful access, closure, and delivery of the endograft during complex EVAR. Endpoints were vascular injury or EC disruption, secondary interventions, and EC patency. RESULTS: Unilateral EC was performed in 45 patients (76%). ECs were extended into the CFA in 21 patients (35%). Median diameters of the native common iliac, external iliac, and CFA were 7 mm (interquartile range [IQR], 6-8 mm), 6 mm (IQR, 5-7 mm), and 6 mm (IQR, 6-7 mm), respectively. Internal iliac artery was inadvertently excluded in 10 patients (17%). Six patients (10%) had an intraoperative vascular injury during the EC procedure, and six patients (10%) had EC disruption during complex EVAR, including five EC collapses requiring re-stenting and one EC fracture requiring open cut-down and reconstruction with patch angioplasty. In 23 patients (39%), 22 Fr OD devices were used; 20 Fr were used in 22 patients (37%), and 18 Fr in 14 patients (24%). Technical success for accessing EC was 89%. There was no difference in major adverse events at 30 days between the iliac ECs and iliofemoral ECs. Primary patency by Kaplan-Meier estimates at 1, 3, and 5 years were 97.5%, 89%, and 82%, respectively. There was no difference in primary patency between iliac and iliofemoral ECs. Six secondary interventions (10%) were required. The mean follow-up was 34 ± 27 months; no limb loss or amputations occurred during the follow-up. CONCLUSIONS: ECs improve vascular access, and their use prior to complex EVAR is associated with low rates of vascular injury, high technical success, and optimal long-term patency. Complex EVAR procedures can be performed percutaneously by accessing the EC directly under ultrasound guidance and using sequential dilation to avoid EC disruption.


Asunto(s)
Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Arteria Femoral , Arteria Ilíaca , Stents , Grado de Desobstrucción Vascular , Humanos , Masculino , Anciano , Femenino , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Resultado del Tratamiento , Factores de Tiempo , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Anciano de 80 o más Años , Arteria Femoral/cirugía , Arteria Femoral/fisiopatología , Arteria Femoral/diagnóstico por imagen , Estudios Retrospectivos , Arteria Ilíaca/cirugía , Arteria Ilíaca/fisiopatología , Arteria Ilíaca/diagnóstico por imagen , Diseño de Prótesis , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Factores de Riesgo , Complicaciones Posoperatorias/etiología
2.
Catheter Cardiovasc Interv ; 103(2): 317-321, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38123891

RESUMEN

Transcatheter sinus venosus defect closure uses a long covered stent of appropriate length and diameter across the cavoatrial junction after balloon interrogation. The fabric in the covered stent creates a roof for the right upper pulmonary vein that closes the interatrial communication and redirects the vein into the left atrium behind the stent. A fabric tear in the covered stent may cause endoleak that will result in residual flows across the struts of the covered stent, causing procedural failure. This report highlights the identification of fabric leak by angiography and transesophageal echocardiography and steps to overcome this complication by the placement of another overlapping covered stent.


Asunto(s)
Endofuga , Defectos del Tabique Interatrial , Humanos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/terapia , Resultado del Tratamiento , Stents
3.
J Endovasc Ther ; : 15266028241233241, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38379341

RESUMEN

INTRODUCTION: This article aims to evaluate the short-term and mid-term performance of a self-expanding covered stent (COVERA Plus, Bard Tempe, Arizona) during the treatment of Trans-Atlantic Inter-Society Consensus (TASC) C/D aortoiliac obstructive lesions involving the aortic bifurcation. METHODS: A single-center retrospective review of all patients who underwent endovascular reconstruction of the aortoiliac bifurcation for obstructive disease, with the use of Covera, from January 2018 to March 2023. All patients received a postoperative CTA (computed tomography angiography) scan within 1 month from the intervention. Precision of deployment, stent conformation, and stent symmetry were evaluated at the arterial phase of the CTA. Early outcomes were technical success and freedom from open aortic reintervention and/or mortality. Late outcomes were primary and assisted primary patency rates and freedom from reintervention. RESULTS: During the study period, 35 patients underwent primary endovascular treatment of obstructive lesions involving the aortic bifurcation with parallel COVERA stents. Aortoiliac lesions were classified as TASC-IIC in 23 (65.7%) patients and TASC D in 12 (34.2%). Median follow-up was 49 months (interquartile [IQR]: 18-60). Overall survival was 97.1% (95% confidence interval [CI]=91-100) at 60 months. During follow-up, there were one early stent stenosis, treated with an angioplasty and stent relining with an estimated primary patency at 60 months of 97.1% (95% CI=94-100) and a primary-assisted patency of 100%. Estimated freedom from all types of reinterventions at 60 months was 94.3% (95% CI=89-99.3). CONCLUSIONS: The new self-expanding covered Bard COVERA Plus stent used for endovascular treatment of TASC C/D aorto iliac disease proved to be safe and feasible with high technical procedural success rates. Comparison with other types of stents is necessary to further assess the role of the COVERA Plus stent in aortic bifurcation repair. CLINICAL IMPACT: This study investigates the safety and feasibility of the new self-expanding covered Bard Covera Plus stent used for endovascular treatment of TASC C/D aorto iliac disease. The retrospective analysis of 35 patients highlights high technical success and primary patency rate at 60 months. The geometric analysis also helped to underline how this stent can be used precisely in particular conditions. These findings suggest the need for further research to compare COVERA with other types of stents in aortic bifurcation repair.

4.
J Endovasc Ther ; : 15266028231224165, 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38197227

RESUMEN

OBJECTIVES: Aberrant splenic artery aneurysms (ASAAs) located at the splenomesenteric trunk (SMT) and the celiacomesenteric trunk have a close anatomical relationship with the superior mesenteric artery (SMA). The aim of this study was to review our institutional experience of endovascular treatment for ASAAs and evaluate the long-term outcomes. METHODS: A retrospective review of patients with ASAAs who underwent endovascular treatment between December 2006 and December 2022 was performed. The demographics of the patients, aneurysm characteristics, treatment strategies, perioperative and long-term outcomes, and complications were analyzed. RESULTS: A total of 29 patients with ASAAs were endovascularly treated at our institution. The SMT variant occurred in the majority of the patients. All ASAAs were characterized by eccentric growth and extremely short inflow arteries. Only 1 patient's inflow artery of the aneurysm exceeded 1 cm in length. Thirteen patients were treated by coil embolization alone. Four patients received bare stent-assisted coil embolization. A combination of coil embolization and covered stent placement across the orifice of the aberrant splenic artery was performed in the remaining 12 cases. Coil migration into the SMA occurred in 2 patients during the operation. Technical success was achieved in all patients. With a median duration of 63 (34-101) months of follow-up, no intestinal ischemia, aneurysm-related death, aneurysm rupture, or sac enlargement occurred. Three cases of aneurysm sac reperfusion were observed, and 1 patient underwent reintervention with secondary embolization. Asymptomatic occlusion of the covered stent was detected in 1 patient at 2 years. CONCLUSIONS: Endovascular treatment is a safe, effective, and durable option for ASAAs. Inflow embolization might be difficult to achieve in ASAAs and poses a high risk of coil migration into the SMA. Long-term observation indicates that reasonable use of the covered stent could achieve reliable inflow artery exclusion in ASAAs without intestinal complications. CLINICAL IMPACT: Aberrant splenic artery aneurysm (ASAA) is an extremely rare entity. This study reported a large sample size of ASAAs treated by endovascular techniques with long-term follow-up. The ASAA was characterized by an extremely short inflow artery and a close anatomical relationship with the superior mesenteric artery (SMA). Endovascular treatment is a safe, effective, and durable option for ASAAs. Inflow embolization might be difficult to achieve in ASAAs and pose a high risk of coil migration into the SMA. Long-term observation indicates that reasonable use of the covered stent could achieve reliable inflow artery exclusion in ASAAs without intestinal complications.

5.
J Endovasc Ther ; : 15266028241237387, 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38491926

RESUMEN

PURPOSE: This study aimed to assess the efficacy and safety outcome of covered stents (CSs), as compared with bare-metal stents (BMSs), for the treatment of patients with aortoiliac occlusive disease (AIOD). MATERIALS AND METHODS: A systematic literature search was conducted in PubMed, Embase, and Cochrane Library up to August 2023 to identify all studies comparing efficacy and safety outcomes of CSs versus BMSs for treating AIOD. Our outcome was primary patency, secondary patency, technical success, ankle-brachial index (ABI) variation, target lesion revascularization (TLR), limb salvage, complications, and long-term survival. Dichotomous outcomes were pooled as relative risks (RR) or hazard ratio with the 95% confidence interval (CI). Continuous outcomes were pooled as weighted mean differences and 95% CI. Model selection was based on the heterogeneity of the included studies. RESULTS: There were 10 studies (2 randomized controlled trials, 8 retrospective cohort studies), comprising 1676 sample size. Compared with BMSs, CSs use was associated with better primary patency of patients with a Trans-Atlantic Inter-Society Consensus II (TASC) D lesion (RR, 1.15, 95% CI, 1.04 to 1.27, p=0.007), TLR (RR, 0.39, 95% CI, 0.27 to 0.56, p<0.001), technical success (RR, 1.01, 95% CI, 1.00 to 1.02, p=0.010), and long-term survival (RR, 1.06, 95% CI, 1.01 to 1.11, p=0.020). There is no difference between CSs and BMSs regarding primary patency of all patients, secondary patency, variation in ABI, limb salvage, and complications. CONCLUSIONS: Compared with BMSs, CSs used in AIOD was associated with more favorable primary patency in patients with TASC D lesions, TLR, technical success rates, and patient long-term survival. These results provide evidence of the advantages of using CSs for AIOD treatment. Future studies focusing on long-term variations in ABI, primary patency of different degrees of calcification, vascular segments, and TASC classification are warranted. CLINICAL IMPACT: Although several studies evaluated the clinical efficacy of CS in the context of AIOD treatment, the significance and consistency of these findings were not determined to date. We found that CS was used in AIOD associated with better technical success rate, long-term patient survival, lower target lesion revascularization, and higher primary patency of patients with a Trans-Atlantic Inter-Society Consensus II D lesion when compared with BMSs. Our study provides evidence supporting the superiority of CSs over BMSs in the treatment of AIOD, and furnishing clinicians with guidance for treatment decisions.

6.
J Endovasc Ther ; : 15266028241231520, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38349021

RESUMEN

OBJECTIVE: This study aims to compare the 5-year outcomes of endoluminal bypass (EB) using heparin-bonded self-expanding covered stents versus bypass surgery for extensive femoropopliteal disease, including technical and clinical outcomes and health status. BACKGROUND: The surgical femoropopliteal bypass was the gold standard to treat peripheral arterial disease (PAD) for decades; however, endovascular treatment modalities are now recommended for most femoropopliteal lesions. One-year data of a randomized controlled trial comparing EB with surgical bypass (SB) have shown a faster recovery, less morbidity, and comparable patency rates between the two techniques. To date, long-term randomized controlled data regarding both techniques are lacking. METHODS: Five-year results of a multicenter randomized controlled trial comparing EB with SB in patients with femoropopliteal artery disease were evaluated based on intention-to-treat and per-protocol analyses. RESULTS: At 5-year follow-up, primary, primary-assisted, and secondary patency rates were 36.2%, 52.4%, and 68.1% for EB and 49.4%, 72.2%, and 77.8% for SB, respectively (p=0.608). Freedom from target lesion revascularization (fTLR) was 34.1% for EB and 57.6% for SB (p=0.365). In both groups, the ankle-brachial index, Rutherford classification, and walking distance significantly improved compared with baseline without differences between groups at follow-up. Freedom from major amputation rate was 92.6% in the EB group and 96.2% in the SB group (p=0.361). The 36-Item Short-Form Health Survey showed no significant differences between groups. CONCLUSION: Treatment of extensive femoropopliteal disease with self-expanding covered stents provides comparable clinical-related and health-related questionnaire outcomes when compared with SB through 5 years of follow-up. However, the EB is related to a higher number of reinterventions. CLINICAL IMPACT: This present study is the first to report five-year outcomes comparing an endoluminal (EB) using heparin-bonded self-expanding covered stents with surgical bypass (SB) for long and complex femoropopliteal disease. Although the advantages of treatment with EB are mostly seen in the early period after treatment, the outcomes support the use of EB for this indication and seems to be a valid and safe alternative for bypass surgery. Future trials comparing various endovascular strategies may provide further guidance for the development of an evidence-based treatment algorithm.

7.
J Endovasc Ther ; : 15266028241251985, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38708984

RESUMEN

PURPOSE: The treatment of thoracoabdominal aortic aneurysms (TAAAs) using branched endovascular aortic repair (BEVAR) is safe and effective. During deployment, the superior mesenteric artery (SMA) branch can unintentionally open into the celiac trunk (CT) ostium and switched catheterization of the SMA from the CT branch and the CT from the SMA branch can be used as an alternative technique in these cases. This study aimed to investigate the outcome of exchanging the intended target vessels (TVs) for the CT and SMA branches during BEVAR. MATERIALS AND METHODS: A single-center retrospective analysis of patients with TAAAs who underwent BEVAR, using off-the-shelf or custom-made devices (CMDs), with an unintended exchange of TVs for the CT and SMA branches was performed. RESULTS: Between 2014 and 2023, 397 patients were treated with BEVAR for TAAA. Eighteen (4.5%) of those patients were treated with an exchange of TVs for the CT and SMA branches. T-branch was used in 9 cases (50%) and the remaining patients were treated with CMDs. Twelve patients were treated electively, 3 were symptomatic and 3 presented with rupture. Of 36 mesenteric TVs in those 18 patients, 34 (94%) were catheterized successfully, including all 18 SMAs and 16 of the 18 CTs. No branch stenosis or occlusion of the switched mesenteric TVs was detected during follow-up. During 30-day follow-up, 3 patients died and during a median follow-up of 3 (interquartile range [IQR]: 1-15) months 3 more patients died. None of the deaths or the 2 unintended reinterventions was induced by the mesenteric TV exchange. The median hospital stay was 14 (IQR: 9-22) days with a median of 4 (IQR: 2-11) days at the intensive care unit. CONCLUSION: The exchange of the mesenteric TVs for the CT and SMA branches during BEVAR with off-the-shelf and CMD endografts is feasible with good TV patency and freedom from TV-related reinterventions. This alternative technique should be considered in selected cases when direct catheterization via the intended branch is deemed more time-consuming or not feasible. CLINICAL IMPACT: This is the first description of using an exchange of target vessels for the celiac trunk and the superior mesenteric artery branches in patients with thoracoabdominal aortic aneurysms undergoing BEVAR, using off-the-shelf or custom-made devices. The high success rate as well as the good clinical results without any branch stenosis or occlusion during follow-up highlight the feasibility of this alternative technique. It could help in challenging cases when catheterization of the intended target vessels is not possible or too time consuming, resulting in higher success rates of BEVAR and better clinical results.

8.
Artículo en Inglés | MEDLINE | ID: mdl-39154953

RESUMEN

OBJECTIVE: The aim of this study was compare elective surgical repair of popliteal artery aneurysms (PAAs) via a posterior approach vs. endovascular exclusion, analysing early and five year outcomes in a multicentre retrospective study. METHODS: Between January 2010 and December 2023, a retrospectively maintained dataset of all consecutive asymptomatic PAAs that underwent open repair with posterior approach or endovascular repair in 37 centres was investigated. An aneurysm length of ≤ 60 mm was considered the only inclusion criterion. A total of 605 patients were included; 440 PAAs (72.7%) were treated via a posterior approach (open group) and the remaining 165 PAAs (27.3%) were treated using covered stents (endo group). Continuous data were expressed as median with interquartile range. Thirty day outcomes were assessed and compared. At follow up, primary outcomes were freedom from re-intervention, secondary patency, and amputation free survival. Secondary outcomes were survival and primary patency. Estimated five year outcomes were compared using log rank test. RESULTS: At 30 days, no differences were found in major morbidity, mortality, graft occlusion, or re-interventions. Three patients (0.7%) in the open group experienced nerve injury. The overall median duration of follow up was 32.1 months. At five year follow up, freedom from re-intervention was higher in the open group (82.2% vs. 68.4%; p = .021). No differences were observed in secondary patency (open group 90.7% vs. endo group 85.2%; p = .25) or amputation free survival (open group 99.0% vs. endo group 98.4%; p = .73). A posterior approach was associated with better survival outcomes (84.4% vs. 79.4%; p = .050), and primary patency (79.8% vs. 63.8%; p = .012). CONCLUSION: Early and long term outcomes following elective repair of PAAs measuring ≤ 60 mm via a posterior approach or endovascular exclusion seem comparable. Nerve injury might be a rare but potential complication for those undergoing open surgery. Endovascular repair is associated with more re-interventions.

9.
BMC Cardiovasc Disord ; 24(1): 435, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39160486

RESUMEN

BACKGROUND: Currently, the treatment outcomes for complex congenital arteriovenous malformations (AVMs) remain unsatisfactory. This article reports on the utilization of an abdominal aortic stent graft, in conjunction with embolization techniques, for managing acute heart failure triggered by complex congenital arteriovenous malformations in the lower limb. CASE PRESENTATION: We present a case involving a patient with congenital AVMs in the lower limb, who had suffered from prolonged swelling in the left lower limb and recently developed symptoms of heart failure. At the age of 67, the patient was definitively diagnosed with a complex congenital AVMs in the lower limb. This article delves into the practical experiences and limitations encountered in employing an abdominal aortic stent graft, coupled with embolization, to address acute heart failure caused by complex congenital AVMs in the lower limb. CONCLUSIONS: Our article presents the initial report on the challenges and limitations encountered in treating acute heart failure triggered by complex congenital AVMs in the lower limb, utilizing a combination of abdominal aortic stent graft placement and embolization techniques.


Asunto(s)
Malformaciones Arteriovenosas , Embolización Terapéutica , Procedimientos Endovasculares , Insuficiencia Cardíaca , Extremidad Inferior , Stents , Humanos , Embolización Terapéutica/instrumentación , Resultado del Tratamiento , Malformaciones Arteriovenosas/terapia , Malformaciones Arteriovenosas/diagnóstico por imagen , Extremidad Inferior/irrigación sanguínea , Procedimientos Endovasculares/instrumentación , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/etiología , Anciano , Implantación de Prótesis Vascular/instrumentación , Masculino , Prótesis Vascular , Femenino
10.
BMC Cardiovasc Disord ; 24(1): 369, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39020283

RESUMEN

BACKGROUND: Innominate artery aneurysms (IAAs) are rare and may result in rupture, distal arterial embolization, or local compression without timely treatment. Rupture is the most dangerous of these complications. This article reports a case of innominate artery bifurcation pseudoaneurysm. CASE PRESENTATION: The patient was a 45-year-old man who was admitted to the emergency department due to chest discomfort. The computed tomographic angiography (CTA) imaging indicated the presence of a 3.6*2.4 cm saccular aneurysm in the bifurcation of the innominate artery, involving both the right proximal subclavian and common carotid arteries. The patient's vital signs were normal, there was equal blood pressure in the upper arms and no neurological dysfunction was observed. Gadolinium-enhanced magnetic resonance angiography indicated that the circle of Willis was intact. The treatment involved open surgery combined with endovascular therapy. The external carotid artery was first transposed to the right subclavian artery (RSA) and an 8-mm woven Dacron graft was inserted in the middle. The covered stent graft was then placed in the proximal part of the innominate artery to close the entrance of the aneurysm. Lastly, an occluder was implanted at the origin of the RSA. There were no perioperative or postoperative complications. At 1-year follow-up, no aneurysm was observed on CTA and the right vertebral artery was patent. CONCLUSIONS: This study indicated that the combined use of endovascular therapy and open repair surgery is an effective strategy to treat innominate artery bifurcation pseudoaneurysm.


Asunto(s)
Aneurisma Falso , Implantación de Prótesis Vascular , Tronco Braquiocefálico , Procedimientos Endovasculares , Stents , Humanos , Masculino , Persona de Mediana Edad , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/cirugía , Aneurisma Falso/etiología , Aneurisma Falso/terapia , Tronco Braquiocefálico/diagnóstico por imagen , Tronco Braquiocefálico/cirugía , Procedimientos Endovasculares/instrumentación , Resultado del Tratamiento , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Angiografía por Tomografía Computarizada , Angiografía por Resonancia Magnética
11.
Surg Endosc ; 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-39406974

RESUMEN

BACKGROUND: Although the short-term outcomes of bridge-to-surgery (BTS) procedures using self-expandable metal stents are favorable, concerns remain regarding worsened prognosis due to tissue injury in the tumor area. Herein, we describe a newly developed covered stent, the Kawasumi Jabara colonic stent™, designed to reduce tissue damage/injury associated with stent-related complications in BTS procedures. This study aimed to evaluate the efficacy and safety of the Kawasumi Jabara colonic stent as a BTS for obstructive colorectal cancer (OCC). METHODS: This multicenter retrospective observational study included 44 OCC patients who underwent BTS with stents at four facilities between September 2020 and November 2022. The groups of patients receiving the Kawasumi Jabara and non-covered colonic stents were designated Groups C and NC, respectively. Treatment outcomes related to stent placement and surgery were compared using propensity score matching (PSM) analysis. RESULTS: Groups NC and C (n = 34 and 10, respectively) showed no significant differences in sex, age, tumor location, histological type, Colorectal Obstruction Scoring System (CROSS) score, or cStage; however, the stent placement duration was shorter in Group C. No significant differences were found in terms of the technical and clinical success rates for stent placement. Stent dislocation was observed in 0 and 2 cases in Groups C and NC, respectively. PSM analysis between eight cases, each from Groups C and NC, revealed no significant differences in stent-related or surgical outcomes between the groups. However, regarding the gross injury score in the resected specimens, Group C had a lower score than Group NC (1.8 vs. 5.5), and the proportion of pathological tissue injury involving deeper layers was also lower in Group C (37.5% vs. 100%). CONCLUSIONS: Compared to conventional non-covered stents, the Kawasumi Jabara colonic stent™ demonstrated favorable safety during stent insertion, retention, and surgery, with only mild tissue injury.

12.
BMC Nephrol ; 25(1): 271, 2024 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-39182042

RESUMEN

BACKGROUND: Central venous occlusion (CVO) is difficult to treat with percutaneous transluminal angioplasty because the guidewire cannot pass through the occluded segments. In this study, we devised a new method for establishing an extra-anatomic bypass between the right subclavian vein and the superior vena cava via a covered stent to treat whole-segment occlusion of the right brachiocephalic vein (BCV) with calcification. CASE PRESENTATION: We present the case of a 58-year-old female patient who complained of right arm swelling present for 1.5 years. Twelve years prior, the patient began hemodialysis because chronic glomerulonephritis had progressed to end-stage renal disease. During the first 3 years, a right internal jugular vein (IJV)-tunneled cuffed catheter was used as the dialysis access, and the catheter was replaced once. A left arteriovenous fistula (AVF) was subsequently established. Owing to occlusion of the left AVF, a new fistula was established on the right upper extremity 1.5 years prior to this visit. Angiography of the right upper extremity revealed complete occlusion of the right BCV and IJV with calcification. Because of the failure to pass the guidewire across the lesion, we established an extra-anatomic bypass between the right subclavian vein and the superior vena cava with a covered stent. Angiography confirmed the patency of whole vascular access system. After 3 months of follow-up, the patient's AVF function and the bypass patency were satisfactory. CONCLUSIONS: As a new alternative for the treatment of long, angled CVO with or without calcification, a covered stent can be used to establish an extravascular bypass between central veins.


Asunto(s)
Stents , Humanos , Femenino , Persona de Mediana Edad , Venas Braquiocefálicas/cirugía , Venas Braquiocefálicas/diagnóstico por imagen , Vena Subclavia/diagnóstico por imagen , Vena Subclavia/cirugía , Vena Cava Superior/cirugía , Diálisis Renal , Resultado del Tratamiento , Cateterismo Venoso Central , Fallo Renal Crónico/terapia , Fallo Renal Crónico/complicaciones
13.
Vascular ; : 17085381241289811, 2024 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-39364914

RESUMEN

PURPOSE: To describe the technique of off-centering a balloon-expandable covered stent for selective occlusion of a distal entry tear (ET) in a patient, conservatively treated for chronic type B aortic dissection (cTBAD), presenting FL expansion. TECHNIQUE: A 63-year-old male, with conservatively managed cTBAD, presented at follow-up with FL partial thrombosis and expansion (thoracic aorta FL from 21 mm to 27 mm and abdominal aorta FL from 11 mm to 15 mm in 6 months). No proximal ET was identifiable. Distal FL perfusion was caused by an ET in the abdominal aorta feeding a 2 mm accessory renal artery (ARA). As the aortic diameter was below the threshold for endovascular repair, a selective occlusion of the distal ET and ARA was planned. A balloon-expandable covered stent was modified by off-centering the covered stent proximally and resulting in a funnel-shape occluder after deployment across the ET into the ARA. To prevent type Ic endoleak due to possible FL expansion caused by an intra-operatively detected phrenic artery (PA), coils were deployed into the lumen of the modified stent and the ARA. The pre-discharge computed tomography angiography showed exclusion of both the ARA and ET and a type 2 endoleak from the PA. CONCLUSION: A balloon-expandable covered stent can be modified by off-centering the covered stent resulting in a funnel shape to adapt to different diameter requirements.

14.
Vascular ; : 17085381241280458, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39212171

RESUMEN

BACKGROUND: Vessel wall calcification is associated with stent under-expansion and in-stent restenosis. The traditional approaches to treat peripheral artery calcification are percutaneous transluminal angioplasty (PTA) and atherectomy. Shockwave intravascular lithotripsy (IVL) uses sonic wave pressure to disrupt calcium of the severely calcified lesions. Published reports of IVL to treat in-stent restenosis are limited to coronary interventions and bare metal platforms. METHODS: We describe the case of a 55-year-old male with extremely compressed under-expanded covered stents associated with severe wall calcification that resulted in stent occlusion. RESULTS: The IVL system balloon was deployed uneventfully, in a phased manner. Bilateral bare metal stents were also placed in a kissing fashion to further re-expand the arterial segments. Reintervention with IVL facilitated successful revascularization and the stent remained patent at 24 months. CONCLUSION: Our case highlights the use of IVL as an effective tool in the management of vessel wall calcification both for primary and secondary interventions.

15.
Pediatr Cardiol ; 2024 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-39361033

RESUMEN

The effect of stenting of native aortic coarctation (CoA) on post-stenotic dilatation (PSD) has not been previously described. We hypothesized that CoA stenting may lead to positive remodeling of PSD. Retrospective analysis of patients who underwent stent implantation for native CoA from 1999 to 2021 was performed. Primary outcome was incremental change PSD diameter and the PSD/DescAo (Descending Aorta) following stent implantation and comparison between covered and bare-metal stents. 90 consecutive patients, (26 female, average age at first intervention 12.0 years) were included. 35 patients (38.9%) underwent dilatation with bare-metal stents and 55 patients (61.1%) with covered stents. The covered stent subgroup was older (14.0 vs. 9.2 years old, p < 0.001) and PSD was larger (17.0 vs 14.0 mm, p < 0.001). Over a mean of 3.2 years, mean inter-catheterization growth of the PSD was blunted [- 0.05 mm, 95% CI (- 1.5 to 1.4)]. The covered stent subgroup demonstrated a negative inter-catheterization growth compared to the bare-metal stent subgroup (- 0.7 vs 1.6 mm, p < 0.001). When controlled for somatic growth, the PDS/DescAo decreased more significantly among those with covered stent vs bare metal (- 0.12 vs - 0.058, p = 0.004). Stenting of native CoA blunts the growth of PSD; covered stents were significantly associated with regression of the diameter of the PSD over time compared to bare-metal stents.

16.
Kidney Int ; 104(1): 189-200, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36990214

RESUMEN

Use of a covered stent after percutaneous transluminal angioplasty (PTA) was compared to PTA alone for treatment of upper extremity hemodialysis patients with arteriovenous fistula (AVF) stenoses. Patients with AVF stenosis of 50% or more and evidence of AVF dysfunction underwent treatment with PTA followed by randomization of 142 patients to include a covered stent or 138 patients with PTA alone. Primary outcomes were 30-day safety, powered for noninferiority, and six-month target lesion primary patency (TLPP), powered to test whether TLPP after covered-stent placement was superior to PTA alone. Twelve-month TLPP and six-month access circuit primary patency (ACPP) were also hypothesis tested while additional clinical outcomes were observed through two years. Safety was significantly non-inferior while six- and 12-month TLPP were each superior for the covered stent group compared to PTA alone (six months: 78.7% versus 55.8%; 12 months: 47.9% versus 21.2%, respectively). ACPP was not statistically different between groups at six-months. Observed differences at 24 months favored the covered-stent group: 28.4% better TLPP, fewer target-lesion reinterventions (1.6 ± 1.6 versus 2.8 ± 2.0), and a longer mean time between target-lesion reinterventions (380.4 ± 249.5 versus 217.6 ± 158.4 days). Thus, our multicenter, prospective, randomized study of a covered stent used to treat AVF stenosis demonstrated noninferior safety with better TLPP and fewer target-lesion reinterventions than PTA alone through 24 months.


Asunto(s)
Angioplastia de Balón , Fístula Arteriovenosa , Derivación Arteriovenosa Quirúrgica , Humanos , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/terapia , Grado de Desobstrucción Vascular , Constricción Patológica/etiología , Angioplastia de Balón/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Derivación Arteriovenosa Quirúrgica/efectos adversos , Angioplastia/efectos adversos , Stents , Fístula Arteriovenosa/etiología , Diálisis Renal/efectos adversos
17.
J Vasc Surg ; 78(5): 1228-1238.e1, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37399971

RESUMEN

BACKGROUND: Endovascular intervention (EI) is the most commonly used modality for chronic mesenteric ischemia (CMI). Since the inception of this technique, numerous publications have reported the associated clinical outcomes. However, no publication has reported the comparative outcomes over a period of time in which both the stent platform and adjunctive medical therapy have evolved. This study aims to assess the impact of the concomitant evolution of both the endovascular approach and optimal guideline-directed medical therapy (GDMT) on CMI outcomes over three consecutive time eras. METHODS: A retrospective review at a quaternary center from January 2003 to August 2020 was performed to identify patients who underwent EIs for CMI. The patients were divided into three groups based on the date of intervention: early (2003-2009), mid (2010-2014), and late (2015-2020). At least one angioplasty/stent was performed for the superior mesenteric artery (SMA) and/or celiac artery. The patients' short- and mid-term outcomes were compared between the groups. Univariable and multivariable Cox proportional hazard models were also conducted to evaluate the clinical predictors for primary patency loss in SMA only subgroup. RESULTS: A total of 278 patients were included (early, 74; mid, 95; late, 109). The overall mean age was 71 years, and 70% were females. High technical success (early, 98.6%; mid, 100%; late, 100%; P = .27) and immediate resolution of symptoms (early, 86.3%; mid, 93.7%; late, 90.8%; P = .27) were noted over the three eras. In both the celiac artery and SMA cohorts, the use of bare metal stents (BMS) declined over time (early, 99.0%; mid, 90.3%; late, 65.5%; P < .001) with a proportionate increase in covered stents (CS) (early, 0.99%; mid, 9.7%; late, 28.9%; P < .001). The use of postoperative antiplatelet and statins has increased over time (early, 89.2%; mid, 97.9%; late, 99.1%; P = .003) and (early, 47%; mid, 68%; late, 81%; P = .001), respectively. In the SMA stent-only cohort, no significant differences were noted in primary patency rates between BMS and CS (hazard ratio, 0.95; 95% confidence interval, 0.26-2.87; P = .94). High-intensity preoperative statins were associated with fewer primary patency loss events compared to none/low- or moderate-intensity statins (hazard ratio, 0.30; 95% confidence interval, 0.11-0.72; P = .014). CONCLUSIONS: Consistent outcomes were observed for CMI EIs across three consecutive eras. In the SMA stent-only cohort, no statistically significant difference in early primary patency was noted for CS and BMS, making the use of CS at additional cost controversial and possibly not cost effective. Notably, the preoperative high-intensity statins were associated with improved SMA primary patency. These findings demonstrate the importance of guideline-directed medical therapy as an essential adjunct to EI in the treatment of CMI.

18.
J Vasc Surg ; 77(6): 1598-1606.e3, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36822256

RESUMEN

OBJECTIVE: To investigate the technical periprocedural and midterm outcomes of endovascular repairs with multibranched endovascular repair or iliac branch devices combined with a new self-expanding covered stent. METHODS: The COvera in BRAnch registry is a physician-initiated, multicenter, ambispective, observational registry (ClinicalTrials.gov Identifier: NCT04598802) enrolling patients receiving a multibranched endovascular repair or iliac branch devices procedure mated with Bard Covera Plus (Tempe, AZ) covered stent, designed to evaluate the outcomes of the covered stent mated with patient-specific and off-the-shelf branched stent graft. Primary end points were technical success, branch instability, and freedom from aortic and branch-related reintervention within 30 days and at follow-up. Preoperative characteristics, comorbidities, and outcomes definitions were graded according to the Society for Vascular Surgery reporting standards. RESULTS: Two hundred eighty-four patients (76 years; range, 70-80 years; 79% males) in 24 centers were enrolled for a total of 708 target vessels treated. The covered stents were mated with an off-the-shelf graft in 556 vessels (79%) and a custom-made graft in 152 (21%). Three hundred seven adjunctive relining stents in 277 vessels (39%) were deployed, of which 116 (38%) were proximal, 66 (21%) intrastent, and 125 (41%) distal. Adjunctive relining stent placement was more frequent when landing in a vessel branch instead of the main trunk (59% vs 39%; P = .031), performing a percutaneous access (49% vs 35%; P < .001), using a stent with a diameter of 8 mm or greater (44% vs 36%; P = .032) and a length of 80 mm or greater (65% vs 55%; P = .005), when a post-dilatation was not performed (45% vs 29%; P < .001) and when an inner branch configuration was used (55% vs 35%; P < .001). Perioperative technical bridging success was 98%. Eight patients (3%) died in the perioperative period. Two deaths (1%) were associated with renal branch occlusion followed by acute kidney injury and paraplegia. Follow-up data were available for 638 vessels (90%) at a median of 32 months (Q1, Q3, 21, 46). Branch instability was reported in 1% of branches. Forty-six patients (17%) died during follow-up, nine (3%) of them owing to aortic-related causes. Primary patency rates at 1, 2, and 3 years were 99% (581/587), 99% (404/411), and 97% (272/279), respectively. Branch instability was associated with patient-specific devices (9% vs 4%; P = .014) and intrastent adjunctive stent placement (12% vs 2%; P = .003), especially when a bare metal balloon-expandable stent was used (25% vs 3%; P < .001). CONCLUSIONS: The use of this new self-expanding covered stent mated with branched endografts proved to be safe and feasible with high technical procedural success rates. Low rates of branch instability were observed at midterm follow-up. Comparative studies with other commercially available covered stents are warranted.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Femenino , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Torácica/cirugía , Factores de Riesgo , Grado de Desobstrucción Vascular , Diseño de Prótesis , Resultado del Tratamiento , Stents , Italia , Procedimientos Endovasculares/efectos adversos , Sistema de Registros
19.
Rev Cardiovasc Med ; 24(7): 197, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39077012

RESUMEN

Background: Currently, commercially covered stents are the main treatment for coronary artery perforation (CAP), but without satisfied late-term outcomes when compared to drug-eluting stents (DES). This study seeks to report a new covered stent to treat porcine CAP, which is manufactured with DES and a biodegradable membrane fabricated by poly-L-lactic acid (PLLA) polymer. Methods: Experimental swines experienced CAP in proximal-middle of right coronary artery (RCA) by non-compliant balloon burst, and covered stent was deployed in breach segment. Meanwhile, coronary angiography (CAG), optical coherence tomography (OCT), histological light microscopy and scan electron microscopy were performed to characterize the performance of covered stent. Results: Seven swines were used for this study. Two swines were euthanasia at 14 days and 28 days after procedure, respectively. The remaining 5 kept alive until sacrifice at six months. CAG at six months showed total occlusion at the stented segment of RCA in all swines. The interventional revascularization of occlusion lesion was instituted in two swines. After recanalizing occlusion lesion, OCT examination visualized diffuse heterogeneous fibrous plaques, as well as organized thrombosis, lipid deposits and several neoatherosclerosis in the occluded segment. Serial histopathologic and electron microscopies at 14 days, 28 days and six months revealed gradual occlusive vessel lumen with diffuse heterogeneous fibroplasia, smooth muscle proliferation, inflammation response and local neoatherosclerosis, moreover with identification of PLLA polymer membrane degradability. Conclusions: The new covered stent with biodegradable membrane could seal urgent coronary breach and prevent experimental swines death, but with all stent occlusion in mid-term (six months) follow-up, which might be attributed to diffuse heterogeneous fibroplasia, smooth muscle proliferation, inflammation response and local neoatherosclerosis with the degradation of PLLA membrane.

20.
Catheter Cardiovasc Interv ; 102(5): 896-899, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37746918

RESUMEN

Despite improvements in current devices and techniques for complex chronic total occlusion (CTO) percutaneous coronary intervention (PCI), procedural complications, including coronary perforation, still occur and could be life-threatening. A patient with a history of multivessel coronary artery disease and a CTO of the right coronary artery (RCA) underwent successful retrograde crossing of an RCA CTO. After wiring the CTO body and lesion dilatation, a drug-eluting stent was implanted in the distal RCA toward the posterior descending artery. A large Ellis type III perforation occurred at the distal edge of the stent. Septal crossing with a balloon and tamponade of the perforation site through the retrograde collaterals followed, as the RCA was not suitable to accommodate easily both the covered stent and the balloon simultaneously. This case report presents a novel approach the "septal retrograde ping-pong" technique, which demonstrates successful treatment of coronary perforations by utilizing a retrograde approach through a septal collateral. This technique proves to be effective in situations where the conventional antegrade balloon or covered stent delivery methods are not feasible or unsuccessful. This innovative approach offers a promising alternative for managing challenging cases of coronary perforations, providing new insights and potential solutions for interventional cardiologists.


Asunto(s)
Oclusión Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Angiografía Coronaria , Resultado del Tratamiento , Circulación Colateral , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Enfermedad Crónica