Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 282
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
J Med Virol ; 96(9): e29881, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39221498

RESUMEN

While HC2 and GP5+/6+ PCR-EIA were pivotal in test validation of new HPV assays, they represent the first generation of comparator tests based upon technologies that are not in widespread use anymore. In the current guideline, criteria for second-generation comparator tests are presented that include more detailed resolution of HPV genotypes. Second-generation comparator tests should preferentially target only the 12 genotypes classified as carcinogenic (IARC-group I), and show consistent non-inferior sensitivity for CIN2+ and CIN3+ and specificity for ≤CIN1 compared to one of the first-generations comparators, in at least three validation studies using benchmarks of 0.95 for relative sensitivity and 0.98 for relative specificity. Validation should take into account used storage media and other sample handling procedures. Meta-analyses were conducted to identify the assays that fulfill these stringent criteria. Four tests fulfilled the new criteria: (1) RealTime High-Risk HPV Test (Abbott), (2) Cobas-4800 HPV test (Roche Molecular System), (3) Onclarity HPV Assay (BD Diagnostics), and (4) Anyplex II HPV HR Detection (Seegene), each evaluated in three to six studies. Whereas the four assays target 14 carcinogenic genotypes, the first two identify separately HPV16 and 18, the third assay identifies five types separately and the fourth identifies all the types separately.


Asunto(s)
Detección Precoz del Cáncer , Papillomaviridae , Infecciones por Papillomavirus , Sensibilidad y Especificidad , Neoplasias del Cuello Uterino , Femenino , Humanos , ADN Viral/genética , Detección Precoz del Cáncer/métodos , Genotipo , Pruebas de ADN del Papillomavirus Humano/métodos , Pruebas de ADN del Papillomavirus Humano/normas , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Papillomaviridae/genética , Papillomaviridae/clasificación , Papillomaviridae/aislamiento & purificación , Infecciones por Papillomavirus/diagnóstico , Infecciones por Papillomavirus/virología , Neoplasias del Cuello Uterino/diagnóstico , Neoplasias del Cuello Uterino/virología
2.
Cytokine ; 184: 156778, 2024 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-39395311

RESUMEN

BACKGROUND: Previous studies indicated that pleural fluid complement C1q was helpful for diagnosing tuberculous pleural effusion (TPE), but the participants in these studies were young. The diagnostic accuracy of C1q for TPE in elderly patients remains unknown. This study aimed to investigate the diagnostic accuracy of C1q for TPE in elderly patients. METHODS: We prospectively recruited patients with undiagnosed pleural effusion who visited the Affiliated Hospital of Inner Mongolia Medical University between September 2018 and July 2021. Their C1q in pleural fluid was detected, and the diagnostic accuracy of C1q was assessed by the receiver operating characteristic (ROC) curve analysis. RESULTS: The median ages of patients with TPE and non-TPE were 75 and 71 years, respectively. TPE patients had significantly higher C1q than non-TPE. The area under the ROC curve (AUC) of C1q was 0.67 (95 %CI: 0.51-0.82). At the threshold of 100 mg/L, C1q had a sensitivity of 0.44 (95 %CI: 0.19-0.69) and specificity of 0.79 (95 %CI: 0.71-0.86). CONCLUSION: C1q in pleural fluid has low diagnostic accuracy for TPE in elderly patients.

3.
Cytokine ; 179: 156618, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38663252

RESUMEN

BACKGROUND: Pleural biomarkers represent potential diagnostic tools for tuberculous pleural effusion (TPE) due to their advantages of low cost, short turnaround time, and less invasiveness. This study evaluated the diagnostic accuracy of two CXCR3 ligands, C-X-C motif chemokine ligand 9 (CXCL9) and CXCL11, for TPE. In addition, we investigated the cellular origins and biological roles of CXCL9 and CXCL11 in the development of TPE. METHODS: This double-blind study prospectively enrolled patients with undiagnosed pleural effusion from two centers (Hohhot and Changshu) in China. Pleural fluid on admission was obtained and levels of CXCL9 and CXCL11 were measured by an enzyme-linked immunosorbent assay (ELISA). The receiver operating characteristic (ROC) curve and the decision curve analysis (DCA) were used to evaluate their diagnostic accuracy and net benefit, respectively. THP-1 cell-derived macrophages were treated with Bacillus Calmette-Guérin (BCG), and quantitative real-time PCR (qRT-PCR) and ELISA were used to determine the mRNA and protein levels of CXCL9 and CXCL11. The chemoattractant activities of CXCL9 and CXCL11 for T helper (Th) cells were analyzed by a transwell assay. RESULTS: One hundred and fifty-three (20 TPEs and 133 non-TPEs) patients were enrolled in the Hohhot Center, and 58 (13 TPEs and 45 non-TPEs) were enrolled in the Changshu Center. In both centers, we observed increased CXCL9 and CXCL11 in TPE patients. The areas under the ROC curves (AUCs) of pleural CXCL9 and CXCL11 in the Hohhot Center were 0.70 (95 % CI: 0.55-0.85) and 0.68 (95 % CI: 0.52-0.84), respectively. In the Changshu Center, the AUCs of CXCL9 and CXCL11 were 0.96 (95 % CI: 0.92-1.00) and 0.97 (95 % CI: 0.94-1.00), respectively. The AUCs of CXCL9 and CXCL11 decreased with the advancement of age. The decision curves of CXCL9 and CXCL11 showed net benefits in both centers. CXCL9 and CXCL11 were upregulated in BCG-treated macrophages. Pleural fluid from TPE and conditioned medium from BCG-treated macrophages were chemotactic for Th cells. Anti-CXCL9 or CXCL11 neutralizing antibodies could partly block the chemotactic activity. CONCLUSIONS: Pleural CXCL9 and CXCL11 are potential diagnostic markers for TPE, but their diagnostic accuracy is compromised in elderly patients. CXCL9 and CXCL11 can promote the migration of peripheral Th cells, thus representing a therapeutic target for the treatment of TPE.


Asunto(s)
Quimiocina CXCL11 , Quimiocina CXCL9 , Derrame Pleural , Receptores CXCR3 , Tuberculosis Pleural , Humanos , Quimiocina CXCL9/metabolismo , Quimiocina CXCL11/metabolismo , Masculino , Femenino , Persona de Mediana Edad , Derrame Pleural/metabolismo , Derrame Pleural/diagnóstico , Receptores CXCR3/metabolismo , Tuberculosis Pleural/diagnóstico , Tuberculosis Pleural/metabolismo , Adulto , Ligandos , Método Doble Ciego , Células THP-1 , Biomarcadores/metabolismo , Macrófagos/metabolismo , Estudios Prospectivos , Anciano , Curva ROC
4.
Biometrics ; 80(3)2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-39225122

RESUMEN

The summary receiver operating characteristic (SROC) curve has been recommended as one important meta-analytical summary to represent the accuracy of a diagnostic test in the presence of heterogeneous cutoff values. However, selective publication of diagnostic studies for meta-analysis can induce publication bias (PB) on the estimate of the SROC curve. Several sensitivity analysis methods have been developed to quantify PB on the SROC curve, and all these methods utilize parametric selection functions to model the selective publication mechanism. The main contribution of this article is to propose a new sensitivity analysis approach that derives the worst-case bounds for the SROC curve by adopting nonparametric selection functions under minimal assumptions. The estimation procedures of the worst-case bounds use the Monte Carlo method to approximate the bias on the SROC curves along with the corresponding area under the curves, and then the maximum and minimum values of PB under a range of marginal selection probabilities are optimized by nonlinear programming. We apply the proposed method to real-world meta-analyses to show that the worst-case bounds of the SROC curves can provide useful insights for discussing the robustness of meta-analytical findings on diagnostic test accuracy.


Asunto(s)
Metaanálisis como Asunto , Sesgo de Publicación , Curva ROC , Humanos , Simulación por Computador , Interpretación Estadística de Datos , Pruebas Diagnósticas de Rutina/estadística & datos numéricos , Modelos Estadísticos , Método de Montecarlo , Sesgo de Publicación/estadística & datos numéricos , Estadísticas no Paramétricas
5.
BMC Med Res Methodol ; 24(1): 111, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38730436

RESUMEN

BACKGROUND: A Generalized Linear Mixed Model (GLMM) is recommended to meta-analyze diagnostic test accuracy studies (DTAs) based on aggregate or individual participant data. Since a GLMM does not have a closed-form likelihood function or parameter solutions, computational methods are conventionally used to approximate the likelihoods and obtain parameter estimates. The most commonly used computational methods are the Iteratively Reweighted Least Squares (IRLS), the Laplace approximation (LA), and the Adaptive Gauss-Hermite quadrature (AGHQ). Despite being widely used, it has not been clear how these computational methods compare and perform in the context of an aggregate data meta-analysis (ADMA) of DTAs. METHODS: We compared and evaluated the performance of three commonly used computational methods for GLMM - the IRLS, the LA, and the AGHQ, via a comprehensive simulation study and real-life data examples, in the context of an ADMA of DTAs. By varying several parameters in our simulations, we assessed the performance of the three methods in terms of bias, root mean squared error, confidence interval (CI) width, coverage of the 95% CI, convergence rate, and computational speed. RESULTS: For most of the scenarios, especially when the meta-analytic data were not sparse (i.e., there were no or negligible studies with perfect diagnosis), the three computational methods were comparable for the estimation of sensitivity and specificity. However, the LA had the largest bias and root mean squared error for pooled sensitivity and specificity when the meta-analytic data were sparse. Moreover, the AGHQ took a longer computational time to converge relative to the other two methods, although it had the best convergence rate. CONCLUSIONS: We recommend practitioners and researchers carefully choose an appropriate computational algorithm when fitting a GLMM to an ADMA of DTAs. We do not recommend the LA for sparse meta-analytic data sets. However, either the AGHQ or the IRLS can be used regardless of the characteristics of the meta-analytic data.


Asunto(s)
Simulación por Computador , Pruebas Diagnósticas de Rutina , Metaanálisis como Asunto , Humanos , Pruebas Diagnósticas de Rutina/métodos , Pruebas Diagnósticas de Rutina/normas , Pruebas Diagnósticas de Rutina/estadística & datos numéricos , Modelos Lineales , Algoritmos , Funciones de Verosimilitud , Sensibilidad y Especificidad
6.
BJOG ; 131(11): 1456-1464, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38660737

RESUMEN

OBJECTIVE: To evaluate the sensitivity of human papillomavirus (HPV) tested urine to detect high-grade cervical precancer (cervical intraepithelial neoplasia grade 2+ [CIN2+]) using two urine collection devices. DESIGN: Randomised controlled trial. SETTING: St Mary's Hospital, Manchester, UK. POPULATION: Colposcopy attendees with abnormal cervical screening; a total of 480 participants were randomised. Matched urine and cervical samples were available for 235 and 230 participants using a first-void urine (FVU)-collection device and standard pot, respectively. METHODS: Urine was self-collected and mixed with preservative - randomised 1:1 to FVU-collection device (Novosanis Colli-pee® 10 mL with urine conservation medium [UCM]) or standard pot. Matched clinician-collected cervical samples were taken before colposcopy. HPV testing used Roche cobas® 8800. A questionnaire evaluated urine self-sampling acceptability. MAIN OUTCOME MEASURES: The primary outcome measured sensitivity of HPV-tested urine (FVU-collection device and standard pot) for CIN2+ detection. Secondary outcomes compared HPV-tested cervical and urine samples for CIN2+ and evaluated the acceptability of urine self-sampling. RESULTS: Urine HPV test sensitivity for CIN2+ was higher with the FVU-collection device (90.3%, 95% CI 83.7%-94.9%, 112/124) than the standard pot (73.4%, 95% CI 64.7%-80.9%, 91/124, p = 0.0005). The relative sensitivity of FVU-device-collected urine was 0.92 (95% CI 0.87-0.97, pMcN = 0.004) compared with cervical, considering that all women were referred after a positive cervical HPV test. Urine-based sampling was acceptable to colposcopy attendees. CONCLUSIONS: Testing of FVU-device-collected urine for HPV was superior to standard-pot-collected urine in colposcopy attendees and has promising sensitivity for CIN2+ detection. General population HPV testing of FVU-device-collected urine will establish its clinical performance and acceptability as an alternative to routine cervical screening.


Asunto(s)
Colposcopía , Detección Precoz del Cáncer , Infecciones por Papillomavirus , Sensibilidad y Especificidad , Toma de Muestras de Orina , Displasia del Cuello del Útero , Neoplasias del Cuello Uterino , Humanos , Femenino , Adulto , Infecciones por Papillomavirus/diagnóstico , Infecciones por Papillomavirus/orina , Neoplasias del Cuello Uterino/diagnóstico , Neoplasias del Cuello Uterino/virología , Displasia del Cuello del Útero/diagnóstico , Displasia del Cuello del Útero/virología , Detección Precoz del Cáncer/métodos , Persona de Mediana Edad , Toma de Muestras de Orina/métodos , Toma de Muestras de Orina/instrumentación , Papillomaviridae/aislamiento & purificación , Manejo de Especímenes/métodos , Manejo de Especímenes/instrumentación , Frotis Vaginal/instrumentación , Virus del Papiloma Humano
7.
Crit Care ; 28(1): 224, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38978055

RESUMEN

BACKGROUND: Acute respiratory distress syndrome (ARDS) is a life-threatening respiratory condition with high mortality rates, accounting for 10% of all intensive care unit admissions. Lung ultrasound (LUS) as diagnostic tool for acute respiratory failure has garnered widespread recognition and was recently incorporated into the updated definitions of ARDS. This raised the hypothesis that LUS is a reliable method for diagnosing ARDS. OBJECTIVES: We aimed to establish the accuracy of LUS for ARDS diagnosis and classification of focal versus non-focal ARDS subphenotypes. METHODS: This systematic review and meta-analysis used a systematic search strategy, which was applied to PubMed, EMBASE and cochrane databases. Studies investigating the diagnostic accuracy of LUS compared to thoracic CT or chest radiography (CXR) in ARDS diagnosis or focal versus non-focal subphenotypes in adult patients were included. Quality of studies was evaluated using the QUADAS-2 tool. Statistical analyses were performed using "Mada" in Rstudio, version 4.0.3. Sensitivity and specificity with 95% confidence interval of each separate study were summarized in a Forest plot. RESULTS: The search resulted in 2648 unique records. After selection, 11 reports were included, involving 2075 patients and 598 ARDS cases (29%). Nine studies reported on ARDS diagnosis and two reported on focal versus non-focal ARDS subphenotypes classification. Meta-analysis showed a pooled sensitivity of 0.631 (95% CI 0.450-0.782) and pooled specificity of 0.942 (95% CI 0.856-0.978) of LUS for ARDS diagnosis. In two studies, LUS could accurately differentiate between focal versus non-focal ARDS subphenotypes. Insufficient data was available to perform a meta-analysis. CONCLUSION: This review confirms the hypothesis that LUS is a reliable method for diagnosing ARDS in adult patients. For the classification of focal or non-focal subphenotypes, LUS showed promising results, but more research is needed.


Asunto(s)
Pulmón , Síndrome de Dificultad Respiratoria , Ultrasonografía , Humanos , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/clasificación , Ultrasonografía/métodos , Ultrasonografía/normas , Pulmón/diagnóstico por imagen , Fenotipo
8.
Ultrasound Obstet Gynecol ; 63(2): 263-270, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37725753

RESUMEN

OBJECTIVE: To determine the diagnostic test accuracy of transvaginal ultrasound (TVS) using a standardized technique for the diagnosis of deep endometriosis (DE) of the uterosacral ligaments (USLs) and adjacent torus uterinus (TU). METHODS: This was a prospective diagnostic test accuracy study conducted at the McMaster University Medical Center Tertiary Endometriosis Clinic, Hamilton, ON, Canada. Consecutive participants were enrolled if they successfully underwent TVS and surgery by our team from 10 August 2020 to 31 October 2021. The index test was TVS using a standardized posterior approach performed and interpreted by an expert sonologist. The reference standard included direct surgical visualization on laparoscopy by the same person who performed and interpreted the ultrasound scans. Accuracy, sensitivity, specificity, positive and negative predictive values (PPV and NPV) and positive and negative likelihood ratios were calculated for the TVS posterior approach for each location using the reference standard. RESULTS: There were 54 consecutive participants included upon completion of laparoscopy and histological assessment. The prevalence of DE for the left USL, right USL and TU was 42.6%, 22.2% and 14.8%, respectively. Based on surgical visualization as the reference standard, TVS demonstrated an accuracy of 92.6% (95% CI, 82.1-97.9%), sensitivity of 82.6% (95% CI, 61.2-95.1%), specificity of 100% (95% CI, 88.8-100%), PPV of 100% and NPV of 88.6% (95% CI, 76.1-95.0%) for diagnosing DE in the left USL. For DE of the right USL, TVS demonstrated an accuracy of 94.4% (95% CI, 84.6-98.8%), sensitivity of 75.0% (95% CI, 42.8-94.5%), specificity of 100% (95% CI, 91.6-100%), PPV of 100% and NPV of 93.3% (95% CI, 84.0-97.4%). For DE of the TU, TVS demonstrated an accuracy of 100% (95% CI, 93.4-100%), sensitivity of 100% (95% CI, 63.1-100%), specificity of 100% (95% CI, 92.3-100%), PPV of 100% and NPV of 100%. CONCLUSIONS: We observed high diagnostic test accuracy of the evaluated standardized TVS technique for assessing DE of the USLs and TU. Further studies evaluating this technique should be performed, particularly with less experienced observers, before considering this technique as the standard approach. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Endometriosis , Vagina , Femenino , Embarazo , Humanos , Vagina/diagnóstico por imagen , Vagina/patología , Endometriosis/diagnóstico por imagen , Endometriosis/cirugía , Sensibilidad y Especificidad , Estudios Prospectivos , Ultrasonografía/métodos , Ligamentos/diagnóstico por imagen , Ligamentos/patología , Pruebas Diagnósticas de Rutina
9.
Lipids Health Dis ; 23(1): 198, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38926783

RESUMEN

BACKGROUND: Lipid accumulation product (LAP) is a novel predictor index of central lipid accumulation associated with metabolic and cardiovascular diseases. This study aims to investigate the accuracy of LAP for the screening of metabolic syndrome (MetS) in general adult males and females and its comparison with other lipid-related indicators. METHODS: A systematic literature search was conducted in PubMed, Scopus, Web of Science, Cumulative Index to Nursing and Allied Health Literature (CINAHL), and ProQuest for eligible studies up to May 8, 2024. Outcomes were pooled mean difference (MD), odds ratio (OR), and diagnostic accuracy parameters (sensitivity, specificity, and area under the summary receiver operating characteristic [AUSROC] curve). Comparative analysis was conducted using Z-test. RESULTS: Forty-three studies involving 202,313 participants (98,164 males and 104,149 females) were included. Pooled MD analysis showed that LAP was 45.92 (P < 0.001) and 41.70 units (P < 0.001) higher in men and women with MetS, respectively. LAP was also significantly associated with MetS, with pooled ORs of 1.07 (P < 0.001) in men and 1.08 (P < 0.001) in women. In men, LAP could detect MetS with a pooled sensitivity of 85% (95% CI: 82%-87%), specificity of 81% (95% CI: 80%-83%), and AUSROC curve of 0.88 (95% CI: 0.85-0.90), while in women, LAP had a sensitivity of 83% (95% CI: 80%-86%), specificity of 80% (95% CI: 78%-82%), and AUSROC curve of 0.88 (95% CI: 0.85-0.91). LAP had a significantly higher AUSROC curve (P < 0.05) for detecting MetS compared to body mass index (BMI), waist-to-height ratio (WHtR), waist-to-hip ratio (WHR), body roundness index (BRI), a body shape index (ABSI), body adiposity index (BAI), conicity index (CI) in both genders, and waist circumference (WC) and abdominal volume index (AVI) in females. CONCLUSION: LAP may serve as a simple, cost-effective, and more accurate screening tool for MetS in general adult male and female populations.


Asunto(s)
Adiposidad , Producto de la Acumulación de Lípidos , Síndrome Metabólico , Humanos , Síndrome Metabólico/diagnóstico , Femenino , Masculino , Adulto , Curva ROC , Tamizaje Masivo/métodos , Factores Sexuales , Circunferencia de la Cintura
10.
Biom J ; 66(7): e202300101, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39330620

RESUMEN

The development of methods for the meta-analysis of diagnostic test accuracy (DTA) studies is still an active area of research. While methods for the standard case where each study reports a single pair of sensitivity and specificity are nearly routinely applied nowadays, methods to meta-analyze receiver operating characteristic (ROC) curves are not widely used. This situation is more complex, as each primary DTA study may report on several pairs of sensitivity and specificity, each corresponding to a different threshold. In a case study published earlier, we applied a number of methods for meta-analyzing DTA studies with multiple thresholds to a real-world data example (Zapf et al., Biometrical Journal. 2021; 63(4): 699-711). To date, no simulation study exists that systematically compares different approaches with respect to their performance in various scenarios when the truth is known. In this article, we aim to fill this gap and present the results of a simulation study that compares three frequentist approaches for the meta-analysis of ROC curves. We performed a systematic simulation study, motivated by an example from medical research. In the simulations, all three approaches worked partially well. The approach by Hoyer and colleagues was slightly superior in most scenarios and is recommended in practice.


Asunto(s)
Biometría , Metaanálisis como Asunto , Curva ROC , Biometría/métodos , Pruebas Diagnósticas de Rutina/métodos , Humanos , Simulación por Computador
11.
J Obstet Gynaecol ; 44(1): 2311664, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38348799

RESUMEN

INTRODUCTION: The diagnosis of endometriomas in patients with endometriosis is of primary importance because it influences the management and prognosis of infertility and pain. Imaging techniques are evolving constantly. This study aimed to systematically assess the diagnostic accuracy of transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI) in detecting endometrioma using the surgical visualisation of lesions with or without histopathological confirmation as reference standards in patients of reproductive age with suspected endometriosis. METHODS: PubMed, Embase, Web of Science, Cumulative Index to Nursing and Allied Health Literature and ClinicalTrials.gov databases were searched from their inception to 12 October 2022, using a manual search for additional articles. Two authors independently performed title, abstract and full-text screening of the identified records, extracted study details and quantitative data and assessed the quality of the studies using the 'Quality Assessment of Diagnostic Accuracy Study 2' tool. Bivariate random-effects models were used to determine the pooled sensitivity and specificity, compare the two imaging modalities and evaluate the sources of heterogeneity. RESULTS: Sixteen prospective studies (10 assessing TVUS, 4 assessing MRI and 2 assessing both TVUS and MRI) were included, representing 1976 participants. Pooled TVUS and MRI sensitivities for endometrioma were 0.89 (95% confidence interval 'CI', 0.86-0.92) and 0.94 (95% CI, 0.74-0.99), respectively (indirect comparison p-value of 0.47). Pooled TVUS and MRI specificities for endometrioma were 0.95 (95% CI, 0.92-0.97) and 0.94 (95% CI, 0.89-0.97), respectively (indirect comparison p-value of 0.51). These studies had a high or unclear risk of bias. A direct comparison (all participants undergoing TVUS and MRI) of the modalities was available in only two studies. CONCLUSION: TVUS and MRI have high accuracy for diagnosing endometriomas; however, high-quality studies comparing the two modalities are lacking.


The diagnosis of endometriomas in patients with endometriosis impacts infertility and pain management. We performed a systematic review and meta-analysis to assess the accuracy of transvaginal ultrasound and magnetic resonance imaging for the diagnosis of endometrioma in patients of reproductive age with suspected endometriosis, and to compare the accuracy of the two imaging modalities. Five databases (PubMed, Embase, Web of Science, Cumulative Index to Nursing and Allied Health Literature and ClinicalTrials.gov databases) were searched. Sixteen prospective studies were included, representing 1976 participants. We found high accuracy of transvaginal ultrasound and magnetic resonance imaging for diagnosing endometriomas. There was no statistically significant difference in diagnostic accuracy between the two modalities. However, high-quality studies comparing the two modalities in the same population are lacking.


Asunto(s)
Endometriosis , Imagen por Resonancia Magnética , Ultrasonografía , Adulto , Femenino , Humanos , Endometriosis/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad , Ultrasonografía/métodos , Vagina/diagnóstico por imagen
12.
Clin Gastroenterol Hepatol ; 21(4): 1070-1081, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35640864

RESUMEN

BACKGROUND & AIMS: We performed a clinical trial that aimed to inform the clinical utility of anorectal manometry (ARM) and balloon expulsion time (BET) as up-front tests to predict outcomes with community-based pelvic floor physical therapy as the next best step to address chronic constipation after failing an empiric trial of soluble fiber supplementation or osmotic laxatives. METHODS: We enrolled 60 treatment-naïve patients with Rome IV functional constipation failing 2 weeks of soluble fiber supplementation or osmotic laxatives. All patients underwent ARM/BET (London protocol) followed by community-based pelvic floor physical therapy. Outcomes were assessed at baseline and 12 weeks. The primary end point was clinical response (Patient Assessment of Constipation-Symptoms instrument). RESULTS: Fifty-three patients completed pelvic rehabilitation and the post-treatment questionnaire. Contemporary frameworks define dyssynergia on balloon expulsion time and dyssynergic patterns (ARM), but these parameters did not inform clinical outcomes (area under the curve [AUC], <0.6). Squeeze pressure (>192.5 mm Hg on at least 1 of 3 attempts; sensitivity, 47.6%; specificity, 83.9%) and limited squeeze duration (inability to sustain 50% of squeeze pressure for >20 seconds; sensitivity, 71.4%; specificity, 58.1%) were the strongest predictors of clinical outcomes. Combining BET with squeeze duration (BET greater than 6.5 seconds and limited squeeze duration) improved predictive accuracy (AUC, 0.75; 95% CI, 0.59-0.90). BET poorly predicted outcomes as a single test (AUC, 0.54; 95% CI, 0.38-0.69). CONCLUSIONS: Using ARM to evaluate squeeze profiles, rather than dyssynergia, appears useful to screen patients with chronic constipation for up-front pelvic floor physical therapy based on likelihood of response. BET appears noninformative as a single screening test (ClinicalTrials.gov: NCT04159350).


Asunto(s)
Laxativos , Diafragma Pélvico , Humanos , Canal Anal , Ataxia/terapia , Estreñimiento/diagnóstico , Estreñimiento/terapia , Defecación/fisiología , Manometría/métodos , Diafragma Pélvico/fisiología , Modalidades de Fisioterapia , Recto
13.
Clin Gastroenterol Hepatol ; 21(4): 1082-1090, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35341952

RESUMEN

BACKGROUND & AIMS: Rectal evacuation disorders are common among constipated patients. We aimed to evaluate the accuracy of an investigational point-of-care test (rectal expulsion device [RED]) to predict outcomes with community-based pelvic floor physical therapy. METHODS: We enrolled patients meeting Rome IV criteria for functional constipation failing fiber/laxatives for more than 2 weeks. RED was inserted and self-inflated, and then time-to-expel was measured in a left lateral position. All patients underwent empiric community-based pelvic floor physical therapy in routine care with outcomes measured at 12 weeks. The primary end point was global clinical response (Patient Assessment of Constipation Symptoms score reduction, >0.75 vs baseline). Secondary end points included improvement in health-related quality-of-life (Patient Assessment of Constipation Quality of Life score reduction, >1.0) and complete spontaneous bowel movement frequency (Food and Drug Administration complete spontaneous bowel movement responder definition). RESULTS: Thirty-nine patients enrolled in a feasibility phase to develop the use-case protocol. Sixty patients enrolled in a blinded validation phase; 52 patients (mean, 46.9 y; 94.2% women) were included in the intention-to-treat analysis. In the left lateral position, RED predicted global clinical response (generalized area under the curve [gAUC], 0.67; 95% CI, 0.58-0.76]), health-related quality-of-life response (gAUC, 0.67; 95% CI, 0.58-0.77; P < .001), and complete spontaneous bowel movement response (gAUC, 0.63; 95% CI, 0.57-0.71; P < .001). As a screening test, a normal RED effectively rules out evacuation disorders (expected clinical response, 8.9%; P = .042). Abnormal RED in the left lateral position (defined as expulsion within 5 seconds or >120 seconds) predicted 48.9% clinical response to physical therapy. A seated maneuver enhanced the likelihood of clinical response (71.1% response with seated RED retained >13 seconds) but likely is unnecessary in most settings. CONCLUSIONS: RED offers an opportunity to disrupt the paradigm by offering a personalized approach to managing chronic constipation in the community (Clinicaltrials.gov: NCT04159350).


Asunto(s)
Diafragma Pélvico , Enfermedades del Recto , Humanos , Femenino , Masculino , Calidad de Vida , Estreñimiento/diagnóstico , Estreñimiento/terapia , Defecación/fisiología , Resultado del Tratamiento , Modalidades de Fisioterapia
14.
BMC Med ; 21(1): 110, 2023 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-36978074

RESUMEN

BACKGROUND: The global spread of COVID-19 created an explosion in rapid tests with results in < 1 hour, but their relative performance characteristics are not fully understood yet. Our aim was to determine the most sensitive and specific rapid test for the diagnosis of SARS-CoV-2. METHODS: Design: Rapid review and diagnostic test accuracy network meta-analysis (DTA-NMA). ELIGIBILITY CRITERIA: Randomized controlled trials (RCTs) and observational studies assessing rapid antigen and/or rapid molecular test(s) to detect SARS-CoV-2 in participants of any age, suspected or not with SARS-CoV-2 infection. INFORMATION SOURCES: Embase, MEDLINE, and Cochrane Central Register of Controlled Trials, up to September 12, 2021. OUTCOME MEASURES: Sensitivity and specificity of rapid antigen and molecular tests suitable for detecting SARS-CoV-2. Data extraction and risk of bias assessment: Screening of literature search results was conducted by one reviewer; data abstraction was completed by one reviewer and independently verified by a second reviewer. Risk of bias was not assessed in the included studies. DATA SYNTHESIS: Random-effects meta-analysis and DTA-NMA. RESULTS: We included 93 studies (reported in 88 articles) relating to 36 rapid antigen tests in 104,961 participants and 23 rapid molecular tests in 10,449 participants. Overall, rapid antigen tests had a sensitivity of 0.75 (95% confidence interval 0.70-0.79) and specificity of 0.99 (0.98-0.99). Rapid antigen test sensitivity was higher when nasal or combined samples (e.g., combinations of nose, throat, mouth, or saliva samples) were used, but lower when nasopharyngeal samples were used, and in those classified as asymptomatic at the time of testing. Rapid molecular tests may result in fewer false negatives than rapid antigen tests (sensitivity: 0.93, 0.88-0.96; specificity: 0.98, 0.97-0.99). The tests with the highest sensitivity and specificity estimates were the Xpert Xpress rapid molecular test by Cepheid (sensitivity: 0.99, 0.83-1.00; specificity: 0.97, 0.69-1.00) among the 23 commercial rapid molecular tests and the COVID-VIRO test by AAZ-LMB (sensitivity: 0.93, 0.48-0.99; specificity: 0.98, 0.44-1.00) among the 36 rapid antigen tests we examined. CONCLUSIONS: Rapid molecular tests were associated with both high sensitivity and specificity, while rapid antigen tests were mainly associated with high specificity, according to the minimum performance requirements by WHO and Health Canada. Our rapid review was limited to English, peer-reviewed published results of commercial tests, and study risk of bias was not assessed. A full systematic review is required. REVIEW REGISTRATION: PROSPERO CRD42021289712.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Metaanálisis en Red , Sesgo , Pruebas Diagnósticas de Rutina , Sensibilidad y Especificidad , Prueba de COVID-19
15.
J Magn Reson Imaging ; 57(5): 1392-1403, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36054564

RESUMEN

BACKGROUND: Accurate diagnosis of axillary lymph node metastasis (ALNM) of breast cancer patients is important to guide local and systemic treatment. PURPOSE: To evaluate the diagnostic performance of different imaging modalities for ALNM in patients with breast cancer. STUDY TYPE: Systematic review and network meta-analysis (NMA). SUBJECTS: Sixty-one original articles with 8011 participants. FIELD STRENGTH: 1.5 T and 3.0 T. ASSESSMENT: We used the QUADAS-2 and QUADAS-C tools to assess the risk of bias in eligible studies. The identified articles assessed ultrasonography (US), MRI, mammography, ultrasound elastography (UE), PET, CT, PET/CT, scintimammography, and PET/MRI. STATISTICAL ANALYSIS: We used random-effects conventional meta-analyses and Bayesian network meta-analyses for data analyses. We used sensitivity and specificity, relative sensitivity and specificity, superiority index, and summary receiver operating characteristic curve (SROC) analysis to compare the diagnostic value of different imaging modalities. RESULTS: Sixty-one studies evaluated nine imaging modalities. At patient level, sensitivities of the nine imaging modalities ranged from 0.27 to 0.84 and specificities ranged from 0.84 to 0.95. Patient-based NMA showed that UE had the highest superiority index (5.95) with the highest relative sensitivity of 1.13 (95% confidence interval [CI]: 0.93-1.29) among all imaging methods when compared to US. At lymph node level, MRI had the highest superiority index (6.91) with highest relative sensitivity of 1.13 (95% CI: 1.01-1.23) and highest relative specificity of 1.11 (95% CI: 0.95-1.23) among all imaging methods when compared to US. SROCs also showed that UE and MRI had the largest area under the curve (AUC) at patient level and lymph node level of 0.92 and 0.94, respectively. DATA CONCLUSION: UE and MRI may be superior to other imaging modalities in the diagnosis of ALNM in breast cancer patients at the patient level and the lymph node level, respectively. Further studies are needed to provide high-quality evidence to validate our findings. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Neoplasias de la Mama , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Femenino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Metástasis Linfática/patología , Neoplasias de la Mama/patología , Metaanálisis en Red , Teorema de Bayes , Tomografía de Emisión de Positrones/métodos , Sensibilidad y Especificidad , Imagen por Resonancia Magnética/métodos , Ganglios Linfáticos/patología , Pruebas Diagnósticas de Rutina
16.
Virol J ; 20(1): 35, 2023 02 24.
Artículo en Inglés | MEDLINE | ID: mdl-36829164

RESUMEN

BACKGROUND: The COVID-19 pandemic highlighted the importance of diagnostic testing against curbing the spread of SARS-CoV-2. The urgent need and scale for diagnostic tools resulted in manufacturers of SARS-CoV-2 assays receiving emergency authorization that lacked robust analytical or clinical evaluation. As it is highly likely that testing for SARS-CoV-2 will continue to play a central role in public health, the performance characteristics of assays should be evaluated to ensure reliable diagnostic outcomes are achieved. METHODS: VALCOR or "VALidation of SARS-CORona Virus-2 assays" is a study protocol designed to set up a framework for test validation of SARS-CoV-2 virus assays. Using clinical samples collated from VALCOR, the performance of Aptima SARS-CoV-2 assay was assessed against a standard comparator assay. Diagnostic test parameters such as sensitivity, specificity and overall per cent agreement were calculated for the clinical performance of Aptima SARS-CoV-2 assay. RESULTS: A total of 180 clinical samples were tested with an addition of 40 diluted clinical specimens to determine the limit of detection. When compared to the standard comparator assay Aptima had a sensitivity of 100.0% [95% CI 95.9-100.0] and specificity of 96.7% [95% CI 90.8-99.3]. The overall percent agreement was 98.3% with an excellent Cohen's coefficient of κ = 0.967 [95% CI 0.929-1.000]. For the limit of detection, Aptima was able to detect all of the diluted clinical samples. CONCLUSION: In conclusion. validation of Aptima SARS-CoV-2 assay using clinical samples collated through the VALCOR protocol showed excellent test performance. Additionally, Aptima demonstrated high analytical sensitivity by detecting all diluted clinical samples corresponding to a low limit of detection.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Técnicas de Laboratorio Clínico/métodos , Prueba de COVID-19 , Técnicas de Diagnóstico Molecular/métodos , Pandemias , Sensibilidad y Especificidad
17.
Epilepsia ; 64(6): 1466-1468, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36756707

RESUMEN

The Critical Success Index (CSI) and Gilbert Skill score (GS) are verification measures that are commonly used to check the accuracy of weather forecasting. In this article, we propose that they can also be used to simplify the joint interpretation of positive predictive value (PPV) and sensitivity estimates across diagnostic accuracy studies of epilepsy data. This is because CSI and GS each provide a single measure that takes the weather forecasting equivalent of PPV and sensitivity into account. We have re-analysed data from our recent systematic review of diagnostic accuracy studies of administrative epilepsy data using CSI and GS. We summarise the results and benefits of this approach.


Asunto(s)
Epilepsia , Humanos , Valor Predictivo de las Pruebas , Epilepsia/diagnóstico , Predicción , Tiempo (Meteorología) , Sensibilidad y Especificidad
18.
BMC Med Res Methodol ; 23(1): 58, 2023 03 10.
Artículo en Inglés | MEDLINE | ID: mdl-36894883

RESUMEN

BACKGROUND: Latent class models are increasingly used to estimate the sensitivity and specificity of diagnostic tests in the absence of a gold standard, and are commonly fitted using Bayesian methods. These models allow us to account for 'conditional dependence' between two or more diagnostic tests, meaning that the results from tests are correlated even after conditioning on the person's true disease status. The challenge is that it is not always clear to researchers whether conditional dependence exists between tests and whether it exists in all or just some latent classes. Despite the increasingly widespread use of latent class models to estimate diagnostic test accuracy, the impact of the conditional dependence structure chosen on the estimates of sensitivity and specificity remains poorly investigated. METHODS: A simulation study and a reanalysis of a published case study are used to highlight the impact of the conditional dependence structure chosen on estimates of sensitivity and specificity. We describe and implement three latent class random-effect models with differing conditional dependence structures, as well as a conditional independence model and a model that assumes perfect test accuracy. We assess the bias and coverage of each model in estimating sensitivity and specificity across different data generating mechanisms. RESULTS: The findings highlight that assuming conditional independence between tests within a latent class, where conditional dependence exists, results in biased estimates of sensitivity and specificity and poor coverage. The simulations also reiterate the substantial bias in estimates of sensitivity and specificity when incorrectly assuming a reference test is perfect. The motivating example of tests for Melioidosis highlights these biases in practice with important differences found in estimated test accuracy under different model choices. CONCLUSIONS: We have illustrated that misspecification of the conditional dependence structure leads to biased estimates of sensitivity and specificity when there is a correlation between tests. Due to the minimal loss in precision seen by using a more general model, we recommend accounting for conditional dependence even if researchers are unsure of its presence or it is only expected at minimal levels.


Asunto(s)
Pruebas Diagnósticas de Rutina , Modelos Estadísticos , Humanos , Análisis de Clases Latentes , Teorema de Bayes , Sensibilidad y Especificidad
19.
BMC Med Res Methodol ; 23(1): 127, 2023 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-37231347

RESUMEN

BACKGROUND: The statistical models developed for meta-analysis of diagnostic test accuracy studies require specialised knowledge to implement. This is especially true since recent guidelines, such as those in Version 2 of the Cochrane Handbook of Systematic Reviews of Diagnostic Test Accuracy, advocate more sophisticated methods than previously. This paper describes a web-based application - MetaBayesDTA - that makes many advanced analysis methods in this area more accessible. RESULTS: We created the app using R, the Shiny package and Stan. It allows for a broad array of analyses based on the bivariate model including extensions for subgroup analysis, meta-regression and comparative test accuracy evaluation. It also conducts analyses not assuming a perfect reference standard, including allowing for the use of different reference tests. CONCLUSIONS: Due to its user-friendliness and broad array of features, MetaBayesDTA should appeal to researchers with varying levels of expertise. We anticipate that the application will encourage higher levels of uptake of more advanced methods, which ultimately should improve the quality of test accuracy reviews.


Asunto(s)
Modelos Estadísticos , Programas Informáticos , Humanos , Sensibilidad y Especificidad , Teorema de Bayes , Revisiones Sistemáticas como Asunto
20.
Clin Chem Lab Med ; 61(5): 777-794, 2023 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-36656998

RESUMEN

This tutorial shows how to perform a meta-analysis of diagnostic test accuracy studies (DTA) based on a 2 × 2 table available for each included primary study. First, univariate methods for meta-analysis of sensitivity and specificity are presented. Then the use of univariate logistic regression models with and without random effects for e.g. sensitivity is described. Diagnostic odds ratios (DOR) are then introduced to combine sensitivity and specificity into one single measure and to assess publication bias. Finally, bivariate random effects models using the exact binomial likelihood to describe within-study variability and a normal distribution to describe between-study variability are presented as the method of choice. Based on this model summary receiver operating characteristic (sROC) curves are constructed using a regression model logit-true positive rate (TPR) over logit-false positive rate (FPR). Also it is demonstrated how to perform the necessary calculations with the freely available software R. As an example a meta-analysis of DTA studies using Procalcitonin as a diagnostic marker for sepsis is presented.


Asunto(s)
Sepsis , Humanos , Pruebas Diagnósticas de Rutina , Polipéptido alfa Relacionado con Calcitonina , Curva ROC , Sensibilidad y Especificidad , Sepsis/diagnóstico , Metaanálisis como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA