Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.650
Filtrar
Más filtros

Intervalo de año de publicación
1.
Neurologia ; 32(9): 579-586, 2017.
Artículo en Inglés, Español | MEDLINE | ID: mdl-27157521

RESUMEN

INTRODUCTION: Stereotactic surgery is used to place electrodes or cannulas in the brain in order to study the function of several brain structures in preclinical research. The hippocampus has been extensively studied with this methodology due to its involvement in a wide range of neurological, cognitive, emotional, and affective disorders. However, the effects of stereotactic surgery on coordination and motor activity should be evaluated in order to determine whether this surgical procedure causes any neurological alterations that may bias the results of studies incorporating this technique. METHODS: We evaluated the effects of stereotactic surgery and implantation of a cannula into the hippocampus of female Wistar rats on the motor activity, forced swim, and rotarod tests. The stage of the oestrous cycle was included in the statistical analysis. RESULTS: Stereotactic surgery had no impact on any of the motor activity variables assessed in the open field (squares crossed, time spent in grooming, and rearing), forced swim (turning behaviour, lateral swimming, latency to first immobility, and time spent immobile), and rotarod (latency to fall) tests, compared with intact rats. Regardless of surgical manipulation, rats in the metestrus and diestrus stages crossed a greater number of squares and displayed longer immobility times than those in the proestrus and estrus stages. CONCLUSION: Stereotactic surgery for cannula placement in the dorsal hippocampus does not affect coordination and motor activity in rats. We can therefore conclude that this procedure has no neurological complications that may interfere in the interpretation of results of studies applying this technique.


Asunto(s)
Hipocampo/fisiología , Actividad Motora/fisiología , Equilibrio Postural/fisiología , Animales , Cánula , Femenino , Ratas , Ratas Wistar , Técnicas Estereotáxicas , Natación/fisiología
2.
Artículo en Inglés | MEDLINE | ID: mdl-37722656

RESUMEN

BACKGROUND: Acute mastoiditis (AM) is the most common complication of acute otitis media and primarily affects children under the age of two; current data on its prevalence in paediatric patients with cochlear implant (CI) are still scant. Proper management of AM in CI children is crucial in order to avoid the implications (financial and emotional) of an explant. Aim of this paper is to describe the cases of AM occurred among young patients with CI in follow up at our department, also in order to evaluate its prevalence, potential predisposing factors, clinical course and therapeutic strategies. PATIENTS AND METHODS: Retrospective study. Medical records of all paediatric patients with CI, who had at least one year of follow-up, were searched aiming to identify those who developed AM, from January 1st 2002 to January 31st 2022. The following data were collected and analysed: demographic features, implant type and side, interval between CI surgery and AM, treatment, laboratory tests, clinical course, vaccination history, associated diseases. RESULTS: AM was developed by six (1.3%) of the 439 children with CI (541 implanted ears). In total, 9 episodes (2.05 %) were recorded, as three patients reported two consecutive infections. Average time interval between CI surgery, to the first or only AM diagnosis, was 13.8 months (range 3-30 months). Furthermore, 3/6 of patients had a history of recurrent acute otitis media; 2/6 an autism spectrum disorder, associated to a combined immune deficiency in one case. All patients were hospitalized and promptly treated by intravenous antibiotic therapy; 4/6 also underwent a mastoidectomy. CI was not explanted in any cases of this series. CONCLUSIONS: Over a 20-year period, AM rate in CI children was 1.3%, which is consistent with the current literature rates of 1-4.7%. All cases were successfully treated, preserving the integrity of the device. In our experience, the early parenteral antibiotic therapy and, when necessary, surgical treatment were adequate to eradicate the infection.


Asunto(s)
Trastorno del Espectro Autista , Implantes Cocleares , Mastoiditis , Otitis Media , Humanos , Niño , Mastoiditis/epidemiología , Mastoiditis/etiología , Mastoiditis/cirugía , Implantes Cocleares/efectos adversos , Estudios Retrospectivos , Trastorno del Espectro Autista/complicaciones , Trastorno del Espectro Autista/tratamiento farmacológico , Otitis Media/complicaciones , Otitis Media/epidemiología , Antibacterianos/uso terapéutico , Progresión de la Enfermedad
3.
Artículo en Inglés | MEDLINE | ID: mdl-38432617

RESUMEN

BACKGROUND AND OBJECTIVES: The surgery of osseointegrated implants has undergone different modifications over the years with the aim of achieving better results and facilitating the surgical technique. Today the most commonly used technique is the linear incision with tissue preservation and placement of the abutment and implant. The long-term success of this technique has served as the basis for the development of the so-called minimally invasive surgical approach (MIPS). This study compares the short-, medium- and long-term results between the classic linear incision technique and the MIPS technique. MATERIAL AND METHODS: A prospective study was conducted on patients who had an osseointegrated implant placed between February 2016 and February 2020. A total of 59 surgeries were performed, 32 surgeries according to the linear incision technique with tissue preservation and 27 with MIPS technique. Outcomes were evaluated at one week, one month and one year. RESULTS: Statistically significant differences were achieved between the 2 groups at one week after surgery. Eighty per cent of the MIPS patients had Holgers grades 0-1 compared to 35% of the linear technique patients (p = 0.001). No statistically significant differences were observed at one month (p = 0.457) and one year (p = 0.228). One case with grade 4 was recorded which resulted in implant extrusion one month after surgery with the MIPS technique. A new osseointegrated implant was placed 2 months after the fall using the same MIPS technique with good results. We were also able to verify that the duration of surgery was much shorter with the MIPS technique and better tolerated in terms of postoperative discomfort by the patient. CONCLUSIONS: In our experience, the MIPS technique is the technique of choice for surgery of osseointegrated Ponto model implants as it is simpler, faster and presents fewer problems in the immediate postoperative period, with similar long-term postoperative results.


Asunto(s)
Oseointegración , Humanos , Estudios Prospectivos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Anciano , Resultado del Tratamiento , Implantación Dental Endoósea/métodos
4.
Arch Soc Esp Oftalmol (Engl Ed) ; 99(8): 356-358, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38909890

RESUMEN

Epithelial inclusion cysts (EIC) are a rare ocular disease and its physiopathology is not well-known. They consist on growths of ocular surface epithelial cells inside the anterior segment of the eye in the form of a cyst. To date several cases have been published in the literature, none of them related to glaucoma surgery. We describe two cases of EIC after glaucoma devices implantation. An 86 year-old male patient with primary open angle glaucoma develop an EIC in right eye three years after removal of PRESERFLO™ MicroShunt (Santen, Osaka, Japan) and a 9 year-old female patient with glaucoma secondary to uveitis for juvenile idiopathic arthritis develops an EIC under the tube of an Ahmed valve implant during postoperative period. EIC develop after ocular penetrating wounds and an inflammatory stimulus. They are benign proliferations, follow-up is necessary to detect space complications early, so less mutilating surgery is needed for removal.


Asunto(s)
Implantes de Drenaje de Glaucoma , Complicaciones Posoperatorias , Humanos , Masculino , Femenino , Anciano de 80 o más Años , Complicaciones Posoperatorias/etiología , Implantes de Drenaje de Glaucoma/efectos adversos , Niño , Quistes/etiología , Quistes/cirugía , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/etiología , Artritis Juvenil/complicaciones , Glaucoma/etiología , Glaucoma/cirugía , Uveítis/etiología
5.
Artículo en Inglés | MEDLINE | ID: mdl-38220047

RESUMEN

OBJECTIVE: to assess clinical safety and postoperative audiological outcomes in postlingual deafness Spanish speaking patients, who underwent surgery with Nurotron™ cochlear implant. MATERIAL AND METHODS: Retrospective descriptive case series study. We performed follow-up of complications and audiological measurements before and after cochlear implantation. Patients with bilateral severe to profound sensorineural hearing loss or patients with unilateral deafness with/without tinnitus were included. Repeated-measures within-subjects for assess pure tone thresholds and speech performance (bilingual test) with a detailed monitoring to establish security or adverse effects were performed. Analysis of variance tests, repetitive measures, were used for statistical analysis. RESULTS: 31 patients were included, 17 (54.8%) men and 14 (45.2%) women. Mean age at the time of surgery was 49.82 ± 18.8 years. The mean follow-up of the group was 31.56 ± 9.57 months (minimum = 19.6 months and maximum = 52.50 months). As major complication one patient (3.23%) had a hard failure that required removal and re-implantation. 25.8% of the patients presented minor complications, the most frequent being vertigo/unsteadiness in 22.6%. The mean of language discrimination (free field at 65 dB SPL) was 62.19% ± 16.66; being 69.82% ± 7.35 in the group of severe to profound bilateral sensorineural hearing loss. A statistically significant reduction was observed in patients with tinnitus, assessed using the visual analogue scale, preoperative = 7.2 ± 1,6 vs postoperative (18months postoperative) = 1.7 ± 1.3 (p < .001). CONCLUSIONS: The Nurotron™ cochlear implant shows satisfactory audiological results, in accordance with what has been reported in the literature. Minor complications were similar to previous studies, but the percentage of hard failure should continue to be observed, which was higher than other reports with comparable follow-up.


Asunto(s)
Implantes Cocleares , Pérdida Auditiva Sensorineural , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Implantes Cocleares/efectos adversos , Adulto , Pérdida Auditiva Sensorineural/cirugía , Anciano , Implantación Coclear , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Lenguaje , Estudios de Seguimiento , Sordera/cirugía , Diseño de Prótesis , Acúfeno/etiología
6.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38701880

RESUMEN

INTRODUCTION AND OBJECTIVES: The optimal chronic antithrombotic regimen for patients with atrial fibrillation undergoing transcatheter aortic valve implantation (TAVI) remains uncertain. Our aim was to compare the incidence of late bleeding events between patients on direct oral anticoagulants (DOACs) and those on vitamin-K antagonists (VKA). METHODS: This single-center observational study included TAVI patients requiring oral anticoagulation at discharge between 2015 and 2021. The primary endpoint was any clinically significant bleeding event. Secondary endpoints were stroke, heart failure, and all-cause mortality. RESULTS: A total of 702 TAVI procedures were performed, with 297 patients requiring oral anticoagulation at discharge. Among them, 206 (69.4%) received VKA and 91 (30.6%) received DOAC. Baseline clinical, procedural and in-hospital characteristics did not significantly differ between groups, except for better renal function among DOAC patients. The median length of follow-up was 2.8 years. The risk of bleeding events was higher in patients receiving DOACs than in those receiving VKA (HR, 2.27; 95%CI, 1.21-4.26; incidence of 9.7 and 4.2 events per 100 patient-years of follow-up for DOAC and VKA patients, respectively). There were no statistically significant differences in the rates of stroke (HR, 1.28; 95%CI, 0.4-4.3), heart failure hospitalization (HR, 0.92; 95%CI, 0.46-1.86), or all-cause mortality (HR, 1.02; 95%CI, 0.68-1.55). CONCLUSIONS: In older patients undergoing TAVI and receiving anticoagulant therapy for atrial fibrillation, the use of DOAC was associated with a higher risk of late bleeding events than VKA.

7.
Bol Med Hosp Infant Mex ; 81(3): 162-169, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38941647

RESUMEN

BACKGROUND: The cochlear implant (CI) is effective for rehabilitating patients with severe to profound sensorineural hearing loss. However, its placement and use have been associated with various complications, such as those affecting the vestibular system. The objective of this study was to compare vestibular function using the video head impulse test (vHIT) in pediatric patients before and after CI placement. METHODS: A descriptive and retrospective study was conducted. The outcomes of 11 pediatric patients of both sexes with a history of profound hearing loss were evaluated. The results of vestibular-ocular reflex (VOR) gain, saccades, asymmetry, Pérez Rey (PR) index, and VOR/saccade ratio for both ears obtained by the vHIT test before and after CI placement were compared. RESULTS: Of the 11 patients evaluated, the VOR gain showed that 81.8% had normal function, 18.2% had hypofunction, and no patients had hyperfunction before implantation. No statistically significant differences were found when compared with post-implant off and post-implant on conditions (p > 0.05). The extracted variables, asymmetry, PR index, and the VOR/saccades ratio also showed no statistically significant differences between the pre- and post-implant conditions, whether off or on. CONCLUSIONS: The vestibular function of pediatric patients did not show significant changes before and after CI placement. The vHIT test is a valuable tool for assessing vestibular function and could be considered a criterion for surgical and rehabilitation decisions in patients undergoing CI placement.


INTRODUCCIÓN: El implante coclear es un dispositivo eficaz para la rehabilitación de pacientes con hipoacusia neurosensorial severa a profunda. Sin embargo, su colocación y uso se ha asociado a diversas complicaciones, entre ellas a nivel del sistema vestibular. El objetivo del presente estudio fue comparar la función vestibular mediante la prueba de videoimpulso cefálico (vHIT) de pacientes pediátricos antes y después de la colocación del implante coclear. MÉTODOS: Se llevó a cabo un estudio descriptivo y retrospectivo. Se evaluaron los resultados de 11 pacientes pediátricos de ambos sexos con antecedente de hipoacusia profunda. Se compararon los resultados de ganancia del VOR, sacadas, asimetría, índice PR así como la relación VOR/sacadas para ambos oídos obtenidos mediante la prueba vHIT antes y después de la colocación del implante coclear. RESULTADOS: De los 11 pacientes evaluados, la ganancia del VOR mostró que el 81.8% tenía normofunción, 18.2% hipofunción y ningún paciente hiperfunción antes del implante. Al compararlo con la ganancia post implante apagado y post implante encendido no se encontraron diferencias estadísticamente significativas (p > 0.05). Las variables sacadas, asimetría, índice PR así como la relación VOR/sacadas tampoco mostraron diferencias estadísticamente significativas entre las condiciones pre y pos implante ya sea apagado o encendido. CONCLUSIONES: La función vestibular de pacientes pediátricos no mostró cambios significativos previo y posterior a la colocación del implante coclear. La prueba vHIT es una herramienta útil que permite evaluar la función vestibular y que podría considerarse como criterio para tomar decisiones quirúrgicas en pacientes que se encuentran en protocolo para implante coclear.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Prueba de Impulso Cefálico , Pérdida Auditiva Sensorineural , Reflejo Vestibuloocular , Humanos , Femenino , Masculino , Prueba de Impulso Cefálico/métodos , Estudios Retrospectivos , Niño , Preescolar , Reflejo Vestibuloocular/fisiología , Pérdida Auditiva Sensorineural/diagnóstico , Pérdida Auditiva Sensorineural/fisiopatología , Pérdida Auditiva Sensorineural/rehabilitación , Grabación en Video , Movimientos Sacádicos/fisiología , Adolescente , Vestíbulo del Laberinto/fisiopatología
8.
Artículo en Inglés | MEDLINE | ID: mdl-38823774

RESUMEN

INTRODUCTION AND OBJECTIVES: Even though the incidence has decreased in recent years, Down syndrome (DS) remains the most common chromosomal disorder today. Despite being a condition with multisystemic involvement, it often tends to affect the head and neck area, making it a frequent reason for consultation with pediatric otolaryngologists or otologists. The purpose of this work is to be one of the first in Spain to characterize and describe the pathology and therapeutic approach typically provided to these patients, analyzing the evolution from a clinical and auditory perspective. MATERIAL AND METHODS: We aim to analyze a sample of 16 pediatric patients recruited over the past 24 years, diagnosed with Down syndrome, and experiencing a wide range of diseases affecting the ear and its auditory function. RESULTS: 62.50% of the patients were women, whose main reason for seeking specialist care was acute and serous otitis media, accounting for 31.25%. These patients have an indication for treatment for various entities within the otological sphere that usually do not differ from those of a healthy child. However, the evolution and response to treatments can take on a torpid character due to the anatomical characteristics of the ears of these patients. CONCLUSIONS: Although the frequency of children with DS in the pediatric otolaryngologist's clinic is decreasing, these patients have a predisposition to ear diseases with auditory repercussions, with variable evolution depending on the disease and the child's intrinsic characteristics.


Asunto(s)
Síndrome de Down , Humanos , Síndrome de Down/complicaciones , Femenino , Masculino , Niño , Preescolar , Adolescente , Enfermedades del Oído/etiología , Enfermedades del Oído/epidemiología , Lactante , Otitis Media con Derrame/complicaciones , Otitis Media con Derrame/etiología , España/epidemiología
9.
Rev Esp Cardiol (Engl Ed) ; 77(1): 29-38, 2024 Jan.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37437882

RESUMEN

INTRODUCTION AND OBJECTIVES: Transcatheter aortic valve implantation (TAVI) using the cusp overlap technique (COT) has shown a lower pacemaker implantation rate at 30 days. The objective of this study was to compare electrocardiogram changes and clinical outcomes between COT and the traditional technique (TT) at 1 year of follow-up. METHODS: Observational, retrospective, nonrandomized study of consecutive patients undergoing TAVI between January 2015 and January 2021. Patients were matched using a propensity score and the TT was compared with COT. The primary endpoints were electrocardiogram changes and a combined endpoint including pacemaker implantation, hospitalization, or cardiovascular death at 1 year. RESULTS: We included 254 patients. After propensity score matching, 184 patients (92 per group) remained. There were no statistically significant differences in baseline characteristics. At 1 year, COT patients showed a significant reduction in new onset left bundle branch block (49% vs 27%, P=.002) and less P wave (13.1±21.0 msec vs 5.47±12.5 msec; P=.003) and QRS prolongation (29.77±27.0 msec vs 16.38±25.4 msec, P <.001). COT was associated with a significant reduction in the occurrence of the primary endpoint (SHR, 0.39 [IC95%, 0.21-0.76]; P=.005). CONCLUSIONS: At 1 year of follow-up, COT reduced the incidence of new onset left bundle branch block and diminished QRS and P wave widening compared with the TT. COT was also associated with a statistically significant reduction in the occurrence of the combined primary cardiovascular endpoint.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo de Rama/complicaciones , Estudios Retrospectivos , Estimulación Cardíaca Artificial/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Prótesis Valvulares Cardíacas/efectos adversos , Arritmias Cardíacas/terapia , Marcapaso Artificial/efectos adversos , Electrocardiografía , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
10.
Artículo en Inglés, Español | MEDLINE | ID: mdl-39187234

RESUMEN

INTRODUCTION AND OBJECTIVES: Impact of gender on long-term outcomes after transcatheter aortic valve implantation (TAVI) remains uncertain. We aimed to investigate gender-specific differences in TAVI and its impact on outcomes. METHODS: This analysis used data from the prospective Spanish TAVI registry, which included consecutive TAVI patients treated in 46 Spanish centers from 2009 to 2021. The primary endpoint was all-cause mortality at 12 months. Secondary endpoints included in-hospital and 30-day mortality and TAVI-related complications. Adjusted logistic and Cox regression analyses were performed. RESULTS: The study included 12 253 consecutive TAVI patients with a mean age of 81.2±6.4 years. Women (53.9%) were older, and had a higher STS-PROM score (7.0±7.0 vs 6.2±6.7; P < .001) than men. Overall, the TAVI-related complication rate was similar between women and men, with specific gender-related complications. While women more frequently developed in-hospital vascular complications (13.6% vs 9.8%; P <.001) and cardiac tamponade (1.5% vs 0.6%; P=.009), men showed a higher incidence of permanent pacemaker implantation (14.5% vs 17.4%; P=.009). There was no difference in all-cause mortality either in hospital (3.6% vs 3.6%, adjusted OR, 1.01; 95%CI, 0.83-1.23; P=.902), at 30 days (4.2% vs 4.2%, adjusted OR, 0.90; 95%CI, 0.65-1.25; P=.564) or at 1 year (11% vs 13%, adjusted HR, 0.94; 95%CI, 0.80-1.11; P=.60). CONCLUSIONS: Women treated with TAVI are older and have more comorbidities than men, leading to distinct complications between genders. Nevertheless, all-cause mortality in the short-term and at 1-year was similar between men and women.

11.
Rev Esp Cardiol (Engl Ed) ; 77(9): 750-758, 2024 Sep.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38311024

RESUMEN

INTRODUCTION AND OBJECTIVES: Carbohydrate antigen 125 (CA125), a biomarker associated with fluid overload, has proven useful in managing diuretic therapy in heart failure. We aimed to evaluate the impact of diuretic optimization guided by CA125 before transcatheter aortic valve implantation (TAVI) on outcomes. METHODS: This prospective interventional study enrolled patients scheduled for TAVI, in whom baseline CA125 was measured 2 weeks before TAVI. Patients with CA125 ≥ 20 U/mL underwent diuretic up-titration before TAVI. Three groups were included: group I) baseline CA125 <20 U/mL; IIa) CA125 ≥ 20 U/mL that decreased after treatment, and IIb) CA125 ≥ 20 U/mL that did not decrease. The primary outcome was changes in the Kansas City Cardiomyopathy Questionnaire at 3 and 12 months. The secondary endpoint was clinical events. RESULTS: The study included 184 patients (115 group I, 46 IIa, and 23 IIb). Groups I and IIa exhibited early and sustained improvements in the Kansas City Cardiomyopathy Questionnaire (group I: 18.9 points [95%CI, 15.7-22.1; P <.001] at 90 days, and 18.1 [95%CI, 14.9-21.4, P <.001] at 1 year; group IIa: 21.1 points [95%CI, 15.4-26.7; P <.001] and 19.5 [95%CI, 13.9-25.1; P <.001] respectively). In contrast, in group IIb there was no significant improvement at 90 days (P=.12), with improvement being significant only at 1 year (17.8 points, 95%CI, 5.9-29.6; P=.003). Over a median follow-up of 20.7 months, there were 63 (27.83%) deaths or heart failure admissions. Multivariate analysis showed a lower risk of events in group I vs IIb (HR, 0.28; 95%CI, 0.14-0.58; P <.001), and IIa vs IIb (HR, 0.24; 95%CI, 0.11-0.55; P <.001). CONCLUSIONS: Patients with persistently high CA125 despite diuretic therapy pre-TAVI showed slower functional recovery and poorer clinical outcomes after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Antígeno Ca-125 , Calidad de Vida , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Estudios Prospectivos , Antígeno Ca-125/sangre , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Biomarcadores/sangre , Diuréticos/uso terapéutico , Resultado del Tratamiento , Anciano , Estudios de Seguimiento
12.
Artículo en Inglés | MEDLINE | ID: mdl-38797372

RESUMEN

BACKGROUND AND OBJECTIVE: Sound localization plays a crucial role in our daily lives, enabling us to recognize voices, respond to alarming situations, avoid dangers, and navigate towards specific signals. However, this ability is compromised in patients with Single-Sided Deafness (SSD) and Asymmetric Hearing Loss (AHL), negatively impacting their daily functioning. The main objective of the study was to quantify the degree of sound source localization in patients with single-sided deafness or asymmetric hearing loss using a Cochlear Implant (CI) and to compare between the two subgroups. MATERIALS AND METHODS: This was a prospective, longitudinal, observational, single-center study involving adult patients diagnosed with profound unilateral or asymmetric sensorineural hearing loss who underwent cochlear implantation. Sound localization was assessed in a chamber equipped with seven speakers evenly distributed from -90º to 90º. Stimuli were presented at 1000 Hz and intensities of 65 dB, 70 dB, and 75 dB. Each stimulus was presented only once per speaker, totaling 21 presentations. The number of correct responses at different intensities was recorded, and angular error in degrees was calculated to determine the mean angular distance between the patient-indicated speaker and the speaker presenting the stimulus. Both assessments were conducted preoperatively without a cochlear implant and two years post-implantation. RESULTS: The total sample comprised 20 patients, with 9 assigned to the SSD group and 11 to the AHL group. The Preoperative Pure Tone Average (PTA) in free field was 31.7 dB in the SSD group and 41.8 dB in the AHL group. There was a statistically significant improvement in sound localization ability and angular error with the use of the cochlear implant at all intensities in both SSD and AHL subgroups. CONCLUSIONS: Cochlear implantation in patients with SSD and AHL enhances sound localization, reducing mean angular error and increasing the number of correct sound localization responses.

13.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38763211

RESUMEN

INTRODUCTION AND OBJECTIVES: In patients undergoing percutaneous coronary intervention (PCI) in the workup pre-transcatheter aortic valve replacement (TAVR), the clinical impact of coronary revascularization complexity remains unknown. This study sought to examine the impact of PCI complexity on clinical outcomes after TAVR in patients undergoing PCI in the preprocedural workup. METHODS: This was a multicenter study including consecutive patients scheduled for TAVR with concomitant significant coronary artery disease. Complex PCI was defined as having at least 1 of the following features: 3 vessels treated, ≥ 3 stents implanted, ≥ 3 lesions treated, bifurcation with 2 stents implanted, total stent length >60mm, or chronic total occlusion. The rates of major adverse cardiac events (MACE), including cardiovascular mortality, myocardial infarction, and coronary revascularization were evaluated. RESULTS: A total of 1550 patients were included, of which 454 (29.3%) underwent complex PCI in the pre-TAVR workup. After a median follow-up period of 2 [1-3] years after TAVR, the incidence of MACE was 9.6 events per 100 patients-years. Complex PCI significantly increased the risk of cardiac death (HR, 1.44; 95%CI, 1.01-2.07), nonperiprocedural myocardial infarction (HR, 1.52; 95%CI, 1.04-2.21), and coronary revascularization (HR, 2.46; 95%CI, 1.44-4.20). In addition, PCI complexity was identified as an independent predictor of MACE after TAVR (HR, 1.31; 95%CI, 1.01-1.71; P=.042). CONCLUSIONS: In TAVR candidates with significant coronary artery disease requiring percutaneous treatment, complex revascularization was associated with a higher risk of MACE. The degree of procedural complexity should be considered a strong determinant of prognosis in the PCI-TAVR population.

14.
Neurocirugia (Astur : Engl Ed) ; 35(1): 51-56, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-36934973

RESUMEN

Neurosurgical management of basilar invagination (BI) has traditionally been aimed at direct cervicomedullary decompression through transoral dens resection or suboccipital decompression with supplemental instrumented fixation. Dr. Goel introduced chronic atlantoaxial dislocation (AAD) as the etiology in most cases of BI and described a technique for distracting the C1-C2 joint with interfacet spacers to achieve reduction and anatomic realignment. We present our modification to Goel's surgical technique, in which we utilize anterior cervical discectomy (ACD) cages as C1-C2 interfacet implants. A young adult male presented to our institution with BI, cervicomedullary compression, occipitalization of C1, and Chiari 1 malformation. There was AAD of C1 over the C2 lateral masses. This reduced some with preoperative traction. He underwent successful C1-C2 interfacet joint reduction and arthrodesis with anterior cervical discectomy (ACD) cages and concomittant occiput to C2 instrumented fusion. BI can be effectively treated through reduction of AAD and by utilizing ACD cages as interfacet spacers.


Asunto(s)
Articulación Atlantoaxoidea , Luxaciones Articulares , Adulto Joven , Masculino , Humanos , Articulación Atlantoaxoidea/diagnóstico por imagen , Articulación Atlantoaxoidea/cirugía , Luxaciones Articulares/diagnóstico por imagen , Luxaciones Articulares/cirugía , Descompresión Quirúrgica/métodos
15.
Artículo en Inglés | MEDLINE | ID: mdl-38224870

RESUMEN

INTRODUCTION: The maximum comfort level (MCL), threshold level (THR) and electrical impedance change in the postoperative period of the cochlear implant for months until they stabilize. The objective of this article is to establish the variation during 5 post-surgical years of impedance, and its relationship with MCL in unilaterally implanted adults. METHODS: Retrospective study over 5 years, with 78 adult patients implanted with MED-EL in a tertiary hospital from the year 2000 to 2015. The variation in impedance, MCL and the relationship between them were analyzed in basal (9-12), medial (5-8) and apical electrodes (1-4), performing an inferential ANOVA analysis of repeated measures with comparisons between consecutive times, corrected with Bonferroni criteria. RESULTS: 33 men (42.3%) and 45 women (57.7%), with a mean age of 52.7±14.6 years. "Stability" was considered the time of follow-up without statistically significant differences between one visit and the next. Changes in impedance in medial electrodes ceased to be statistically significant at 3 months, and in apicals at 6 months, with mean values of 5.84 and 6.43kΩ. MCL stabilized at 2 years in basal and apical electrodes, and at 3 years in medial, with mean values of 24.9, 22.7, and 25.6qu. There was a correlation between MCL and impedance in medium electrodes up to 3 months and in apical ones up to one year. CONCLUSIONS: Electrical impedance drops significantly in medial and apical electrodes up to 3 and 6 months. MCL increases significantly up to two years. Impedance is related to MCL up to 6 months.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Masculino , Adulto , Humanos , Femenino , Persona de Mediana Edad , Anciano , Impedancia Eléctrica , Estudios Retrospectivos , Umbral Auditivo
16.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38000627

RESUMEN

INTRODUCTION AND OBJECTIVES: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR. METHODS: This multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis. RESULTS: The mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. CONCLUSIONS: Up to 6% of contemporary TAVR patients exhibited an impaired functional status following TAVR. Worse baseline NYHA class, chronic pulmonary obstructive disease, and severe mitral regurgitation predicted 30-day NYHA class III/IV, and this determined a higher risk of mortality and heart failure hospitalization at 1-year follow-up. Further studies on the prevention and treatment optimization of patients with impaired functional status after TAVR are needed.

17.
Cir Cir ; 91(6): 824-828, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38096868

RESUMEN

OBJECTIVE: Determine the effectiveness of endoscopy in cochlear implantation as compared to microscopy. METHOD: Study comparing microscopy and endoscopy in cochlear implant placement in 34 patients (23 endoscopic implants and 20 implants via microscopy), between 2014 and 2019, at the Centro Medico Naval, Mexico City. The study was performed under informed consent and according to the Council for International Organizations of Medical Sciences (CIOMS). RESULTS: Of the 34 patients, 12 were children or adolescents and 22 were adults. The visualization of the round window classified via microscopy per St. Thomas Hospital's classification showed that type IIB prevailed in 30.2% of patients, and type III in 41.9%, and when using the endoscope, the round window was observed in full in 82.6% of patients (type I), and type IIA was only observed in 17.4% (four patients). The number of attempts made to place the cochlear implant was greater with the microscope. The time to insertion of the electrode was 1.6 minutes. No differences were observed (p > 0.05) in the number of inpatient days. Cochleostomy was more frequent when using the microscope. CONCLUSIONS: Endoscopy is an effective resource in cochlear implantation for posterior tympanotomy, with no complications observed, offering greater safety in inserting the electrode through the round window.


OBJETIVO: Determinar la efectividad de la endoscopía en la implantación coclear en comparación con la técnica microscópica. MÉTODO: Se comparó la microscopía frente a la endoscopía en la colocación de implante coclear en 34 pacientes (23 endoscópicos y 20 microscópicos), del año 2014 al año 2019, en el Centro Médico Naval de la Ciudad de México. El estudio se realizó bajo consentimiento informado y apegado a las normas del Council for International Organizations of Medical Sciences. RESULTADOS: De los 34 pacientes, 12 eran niños o adolescentes y 22 eran adultos. La visualización de la ventana redonda fue clasificada con microscopio según la clasificación del St. Thomas Hospital, predominando la tipo IIB (30.2%) y la III (41.9%), y al utilizar el endoscopio se observó completa en el 82.6% (tipo I) y tipo IIA en tan solo el 17.4% (cuatro pacientes). El número de intentos en la colocación del implante coclear fue mayor con el microscopio. El tiempo en el que se insertó el electrodo fue de 1.6 minutos. No hubo diferencias (p > 0.05) en la estancia hospitalaria. Fue más frecuente la cocleostomía cuando se uso el microscopio. CONCLUSIONES: La endoscopía es un instrumento efectivo en la implantación coclear por timpanotomía posterior, sin presentarse complicaciones y dando mayor seguridad para insertar el electrodo por la ventana redonda.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Niño , Adulto , Adolescente , Humanos , Ventana Redonda/cirugía , Endoscopía Gastrointestinal , México
18.
Cir Esp (Engl Ed) ; 101(3): 187-197, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36108952

RESUMEN

INTRODUCTION: In recent years, mastectomy and reconstruction techniques have evolved towards less aggressive procedures, improving the satisfaction and quality of life of women. For this reason, mastectomy has become a valid option for both women with breast cancer and high-risk women. The objective of this study is to analyze the safety of mastectomy and immediate prepectoral reconstruction with polyurethane implant in women with breast cancer and risk reduction. METHOD: Observational prospective study to evaluate the feasibility and safety of immediate reconstruction using prepectoral polyurethane implant. All women (with breast cancer or high risk for breast cancer) who underwent skin-sparing or skin-and-nipple-sparing mastectomy with immediate reconstruction with a prepectoral polyurethane implant were included. Women with breast sarcomas, disease progression during primary systemic therapy (PST), delayed, autologous or retropectoral reconstruction, and those who did not wish to participate in the study were excluded. Surgical procedures were performed by both senior and junior surgeons. All patients received the corresponding complementary treatments. All adverse events that occurred during follow-up and the risk factors for developing them were analyzed. RESULTS: 159 reconstructions were performed in 102 women, 80.4% due to breast carcinoma. Fourteen patients developed complications, the most frequent being seroma and wound dehiscence. Eight women required a reoperation (5.0%), seven of them due to implant exposure. Four reconstructions (2.5%) resulted in loss of the implant. Three patients progressed from their oncological process: a local relapse in the mastectomy flap, an axillary progression and a systemic progression. CONCLUSIONS: Prepectoral reconstruction with a polyurethane implant is a procedure with a low incidence of postoperative complications (8.8%) and implant loss (2.5%). Its use is safe with perioperative cancer treatments (neoadjuvant chemotherapy and radiotherapy).


Asunto(s)
Implantes de Mama , Neoplasias de la Mama , Mamoplastia , Humanos , Femenino , Mastectomía/métodos , Neoplasias de la Mama/cirugía , Estudios Prospectivos , Poliuretanos , Calidad de Vida , Estudios Retrospectivos , Recurrencia Local de Neoplasia/cirugía , Mamoplastia/métodos , Implantes de Mama/efectos adversos , Complicaciones Posoperatorias/epidemiología
19.
Rev Esp Cardiol (Engl Ed) ; 76(12): 991-1002, 2023 Dec.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37137426

RESUMEN

INTRODUCTION AND OBJECTIVES: To evaluate the prevalence, clinical characteristics, and outcomes of patients with angina undergoing transcatheter aortic valve replacement (TAVR) for severe aortic stenosis. METHODS: A total of 1687 consecutive patients with severe aortic stenosis undergoing TAVR at our center were included and classified according to patient-reported angina symptoms prior to the TAVR procedure. Baseline, procedural and follow-up data were collected in a dedicated database. RESULTS: A total of 497 patients (29%) had angina prior to the TAVR procedure. Patients with angina at baseline showed a worse New York Heart Association (NYHA) functional class (NYHA class> II: 69% vs 63%; P=.017), a higher rate of coronary artery disease (74% vs 56%; P <.001), and a lower rate of complete revascularization (70% vs 79%; P <.001). Angina at baseline had no impact on all-cause mortality (HR, 1.02; 95%CI, 0.71-1.48; P=.898) and cardiovascular mortality (HR, 1.2; 95%CI, 0.69-2.11; P=.517) at 1 year. However, persistent angina at 30 days post-TAVR was associated with increased all-cause mortality (HR, 4.86; 95%CI, 1.71-13.8; P=.003) and cardiovascular mortality (HR, 20.7; 95%CI, 3.50-122.6; P=.001) at 1-year follow-up. CONCLUSIONS: More than one-fourth of patients with severe aortic stenosis undergoing TAVR had angina prior to the procedure. Angina at baseline did not appear to be a sign of a more advanced valvular disease and had no prognostic impact; however, persistent angina at 30 days post-TAVR was associated with worse clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Pronóstico , Angina de Pecho/epidemiología , Angina de Pecho/etiología , Angina de Pecho/cirugía , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad
20.
Artículo en Inglés | MEDLINE | ID: mdl-37149131

RESUMEN

INTRODUCTION: In newborns, hearing loss secondary to congenital Cytomegalovirus (CMVc) infection, despite its low prevalence, can cause a serious problem in the personal development and social integration of patients. Therefore, it is important to include the determination of CMV DNA as a neonatal screening tool. MATERIALS AND METHODS: We have carried out a 5-year retrospective study, by describing the CMVc in the Autonomous Community of the Basque Country in newborns who did not pass the hearing screening in the early hearing loss detection program. The times of detection, confirmation (incidence) and intervention (treatment) are described. RESULTS: Of 18,782 subjects studied, 58 (three per thousand live births) presented hearing loss. Of these, CMVc is guaranteed in four patients (one woman and three men). The mean time to hearing screening was 6.5 days (SD: ±3.69) and to detect CMV by polymerase chain reaction (PCR) in urine and saliva was 4.2 days (SD: ± 3.94). Time to confirm hearing loss by BAEP and audiological intervention 2.2 (SD: ±0.957) and 5 months (SD: ±3.741), respectively. Four hearing aid adaptations and one cochlear implant were performed. DISCUSSION AND CONCLUSION: Neonatal hearing screening has established itself as a good public health program. The determination of viral DNA allows an early, specific and interdisciplinary diagnosis and treatment, in which otorhinolaryngology plays a fundamental role. Our study highlights the importance of including CMV PCR as a universal screening tool.


Asunto(s)
Infecciones por Citomegalovirus , Sordera , Pérdida Auditiva , Masculino , Femenino , Humanos , Recién Nacido , Citomegalovirus/genética , Estudios Retrospectivos , Infecciones por Citomegalovirus/complicaciones , Infecciones por Citomegalovirus/diagnóstico , Infecciones por Citomegalovirus/epidemiología , Pérdida Auditiva/etiología , Pérdida Auditiva/complicaciones , Audición
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA