Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.679
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39118252

RESUMEN

OBJECTIVES: This study aims to investigate the occurrence, type and correlation of early and late atrial arrhythmias following mitral valve repair in patients with no preoperative history of atrial arrhythmias. METHODS: Patients undergoing mitral valve (MV) repair for degenerative disease were included. Early and late postoperative electrocardiograms were evaluated for the incidence and type of atrial arrhythmia (atrial fibrillation [AF] or atrial tachycardia [AT]). RESULTS: The 192 patients were included. Early atrial arrhythmias occurred in 100/192 (52.1%) patients; AF in 61 (31.8%) patients, early AT in 15 (7.8%) and both in 24 (12.5%). In total 89% of patients were discharged in sinus rhythm. During a follow-up time of 7.3 years, 14 patients (7.3%) died and 49 (25.5%) patients developed late atrial arrhythmias. At 10 years, the cumulative incidence of any late atrial arrhythmia, with death as competing risk, was 64% (95% confidence interval [CI] = 55%-72%). On Fine-Gray model analysis, only early postoperative AF lasting >24 h was related to the development of late AF (hazard ratio 5.99, 95% CI = 1.78%-20.10%, p = .004). Early postoperative ATs were related to the development of late tachycardias, independent of their duration (<24 h hazard ratio 4.25, 95% CI = 1.89-9.57, p = .001 and >24 h hazard ratio 3.51, 95% CI = 1.65-7.46, p = .001). CONCLUSIONS: Early and late atrial arrhythmias were common after MV repair surgery. Only early postoperative AF lasting >24 h was a risk factor for the occurrence of late AF. Conversely, any postoperative AT was correlated to the development of late ATs.

2.
Catheter Cardiovasc Interv ; 103(2): 382-388, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38078877

RESUMEN

BACKGROUND: Evidence-based recommendations for antithrombotic treatment in patients who have an indication for oral anticoagulation (OAC) after transcatheter edge-to-edge mitral valve repair (TEER) are lacking. AIMS: To compare bleeding and thrombotic risk for different antithrombotic regimens post-TEER with MitraClip in an unselected population with the need for OACs. METHODS: Bleeding and thrombotic complications (stroke and myocardial infarction) up to 3 months after TEER with mitraclip were evaluated in 322 consecutive pts with an indication for OACs. These endpoints were defined by the Mitral Valve Academic Research Consortium criteria and were compared between two antithrombotic regimens: single antithrombotic therapy with OAC (single ATT) and double/triple ATT with a combination of OAC and aspirin and/or clopidogrel (combined ATT). RESULTS: Collectively, 108 (34%) patients received single ATT, 203 (63%) received double ATT and 11 (3%) received triple ATT. Bleeding events occurred in 67 patients (20.9%), with access site related events being the most frequent cause (37%). Bleeding complications were observed more frequently in the combined ATT group than in the single ATT group: 24% versus 14% [p = 0.03, adjusted RR: 0.55 (0.3-0.98)]. Within the combined group, the bleeding risk was 23% in the double ATT and 45% in the triple ATT group. Thrombotic complications occurred in only three patients (0.9%), and all belonged to the combined ATT group. CONCLUSIONS: In patients with an indication for OACs, withholding of antiplatelet therapy post-TEER with Mitraclip was associated with a 45% reduction in bleeding and without a signal of increased thrombotic risk.


Asunto(s)
Inhibidores de Agregación Plaquetaria , Trombosis , Humanos , Inhibidores de Agregación Plaquetaria/efectos adversos , Anticoagulantes/efectos adversos , Fibrinolíticos/efectos adversos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Hemorragia/inducido químicamente , Trombosis/etiología , Trombosis/prevención & control , Sistema de Registros
3.
Catheter Cardiovasc Interv ; 103(7): 1148-1151, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38639161

RESUMEN

The transcatheter edge-to-edge mitral valve repair (TEER) has been recommended as a reliable treatment option for selected patients with severe degenerative and functional mitral regurgitation (MR). Although MR patients with rheumatic etiology were excluded from two significant trials (EVEREST II and COAPT) that established a role for the TEER in degenerative and functional MR. However, it has been reported that the TEER procedure could be safely and effectively performed in carefully selected rheumatic MR patients. Therefore, we share a case report of successfully treating severe rheumatic MR using a novel-designed TEER system (JensClipTM).


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Cardiopatía Reumática , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/etiología , Cateterismo Cardíaco/instrumentación , Resultado del Tratamiento , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/cirugía , Cardiopatía Reumática/fisiopatología , Cardiopatía Reumática/terapia , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Femenino , Ecocardiografía Transesofágica , Ecocardiografía Doppler en Color , Diseño de Prótesis , Prótesis Valvulares Cardíacas , Persona de Mediana Edad , Masculino
4.
Catheter Cardiovasc Interv ; 104(2): 390-400, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38736245

RESUMEN

BACKGROUND: Malnutrition is associated with poor prognosis in several cardiovascular diseases; however, its role in patients with secondary mitral regurgitation (SMR) is poorly known. AIMS: To evaluate the impact of nutritional status, assessed using different scores, on clinical outcomes in patients with SMR undergoing transcatheter edge-to-edge repair (TEER) in a real-world setting. METHODS: A total of 658 patients with SMR and complete nutritional data were identified from the MIVNUT registry. Nutritional status has been assessed using controlling nutritional status index (CONUT), prognostic nutritional index (PNI), and geriatric nutritional risk index (GNRI) scores. Outcomes of interest were all-cause mortality and all-cause mortality or heart failure (HF) hospitalization. RESULTS: Any malnutrition grade was observed in 79.4%, 16.7%, and 47.9% of patients by using CONUT, PNI, and GNRI, respectively, while moderate to severe malnutrition was noted in 24.7%, 16.7%, and 25.6% of patients, respectively. At a median follow-up of 2.2 years, 212 patients (32.2%) died. Moderate-severe malnutrition was associated with a higher rate of all-cause mortality (HR: 2.46 [95% CI: 1.69-3.58], HR: 2.18 [95% CI: 1.46-3.26], HR: 1.97 [95% CI: 1.41-2.74] for CONUT, PNI, and GNRI scores, respectively). The combined secondary endpoint of all-cause mortality and HF rehospitalization occurred in 306 patients (46.5%). Patients with moderate-severe malnutrition had a higher risk of the composite endpoint (HR: 1.56 [95% CI: 1.20-2.28], HR: 1.55 [95% CI: 1.01-2.19], HR: 1.36 [95% CI: 1.02-1.80] for CONUT, PNI, and GNRI scores, respectively). After adjustment for multiple confounders, moderate-severe malnutrition remained independently associated with clinical outcomes. CONCLUSIONS: Moderate-severe malnutrition was common in patients with SMR undergoing TEER. It was independently associated with poor prognosis regardless of the different scores used.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Desnutrición , Insuficiencia de la Válvula Mitral , Válvula Mitral , Evaluación Nutricional , Estado Nutricional , Sistema de Registros , Humanos , Desnutrición/mortalidad , Desnutrición/diagnóstico , Desnutrición/fisiopatología , Femenino , Masculino , Anciano , Factores de Riesgo , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Resultado del Tratamiento , Prevalencia , Factores de Tiempo , Medición de Riesgo , Anciano de 80 o más Años , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Estudios Retrospectivos
5.
Catheter Cardiovasc Interv ; 103(2): 340-347, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38156508

RESUMEN

BACKGROUND: There is currently little evidence for transcatheter edge-to-edge mitral valve repair (TEER) for mitral regurgitation (MR) in patients with cardiogenic shock (CS). Therefore, this study investigated the characteristics and outcomes of CS patients who underwent TEER for MR. METHODS: PubMed, EMBASE were searched in July 2023. Case series and observational studies reporting clinical characteristics and outcomes in CS patients with MR who underwent TEER were included. We performed a one-group meta-analysis using a random effects model. RESULTS: A total of 4060 patients from 7 case series and 5 observational studies were included. The mean age was 68.2 (95% confidence interval [CI]: 64.1-72.2) years, and 41.4% of patients (95% CI: 39.1%-43.7%) were female. Pre-TEER, severe MR was present in 85.3% (95% CI: 76.1%-91.3%) of patients. Mean left ventricular ejection fraction was 36.7% (95% CI: 29.2%-44.2%), and 54.6% (95% CI: 36.9%-71.2%) of patients received mechanical circulatory support. The severity of MR post-TEER was less than 2+ in 88% (95% CI: 87%-89%) of patients. In-hospital mortality was 11% (95% CI: 10%-13%), whereas 30-day and 1-year mortality rates were 15% (95% CI: 13%-16%), and 36% (95% CI: 21%-54%), respectively. CONCLUSIONS: This systematic review and meta-analysis assessed the clinical characteristics and outcomes of TEER in CS patients with MR. TEER for MR in patients with CS has been successful in reducing MR in most of the patients, but with a high mortality rate. Randomized controlled trials of TEER for MR and CS are needed.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Anciano , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
6.
Catheter Cardiovasc Interv ; 103(1): 137-146, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37890011

RESUMEN

BACKGROUND: The development of the PASCAL transcatheter valve repair system for treating mitral regurgitation (MR) greatly extends therapeutic options. AIMS: To assess the safety, efficacy, and time efficiency of the PASCAL system in transcatheter edge-to-edge repair (TEER) under conscious sedation (CS). METHODS: This is a retrospective, two-center, German registry study consisting of 211 patients who underwent TEER using the PASCAL system under CS. The endpoints were to assess (1) technical, device, and procedural success as per Mitral Valve Academic Research Consortium (MVARC), (2) conversion rate to general anesthesia (GA), (3) hospital length of stay (LoS), (4) New York Heart Association (NYHA) class, and (5) MR compared to baseline at 30-day. RESULTS: A total of 211 patients with a mean age of 78.4 ± 8.9 years, with 51.4% being female and 86.7% belonging to NYHA functional class III/IV and EuroSCORE II 6.3 ± 4.9%, were enrolled. Procedural success attained was 96.9%, and six patients (2.8%) required conversion from CS to GA. At 30 days follow-up, a significant improvement in MR was found in 96 patients (54.2%) patients with 0/1 grade MR and 45 patients (29.5%) were in NYHA functional class III + IV. Moreover, TEER under CS has a short hospital LoS (6.71 ± 5.29 days) and intensive care unit LoS (1.34 ± 3.49 days) with a 2.8% mortality rate. CONCLUSIONS: Performing TEER with the PASCAL system under CS resulted in appreciable (96.9%) procedural success with low mortality and is a safe and promising alternative to GA with positive clinical outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Sedación Consciente/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco
7.
Artículo en Inglés | MEDLINE | ID: mdl-39323306

RESUMEN

BACKGROUND: Transcatheter edge-to-edge repair (TEER) has emerged to address symptomatic atrial functional mitral regurgitation (aFMR) in patients who are at high operative risk. AIMS: No clinical data is available on the impact of residual mitral regurgitation (MR) following TEER in aFMR compared to ventricular functional MR (vFMR). METHODS: In the MITRA-PRO registry, 846 patients with FMR and MitraScore assessment for residual MR quantification were included (722 patients with vFMR and 124 patients with aFMR). RESULTS: Compared to vFMR similar procedural results in regard of residual MR following TEER were found in aFMR patients (MitraScore post TEER 2.5 ± 1.8 vs. 2.7 ± 1.9), while the amount of implanted TEER devices was increased in vFMR. 1-year survival was better in aFMR compared to vFMR regardless of relevant residual MR (MitraScore ≥ 4), while 1-year rehospitalization was comparable for both MR entities. Patients with aFMR and mild residual MR had a lower mortality rate (6.6% vs. 10.3%) and rehospitalization rate (29.1% vs. 46.2%) 1 year after mitral TEER. However, in contrast to vFMR a MitraScore ≥4 was no independent predictor of mortality in aFMR indicating a better tolerance toward residual MR. CONCLUSIONS: Residual MR is an independent predictor of 1-year mortality in vFMR patients, whereas in aFMR patients, a MitraScore of ≥4 is associated with higher mortality but is not an independent predictor in multivariate analysis. Therefore, minimizing MR through mitral TEER is crucial for survival in vFMR patients, while aFMR patients tolerate significant residual MR better 1 year after the procedure.

8.
Eur Radiol ; 34(8): 4963-4976, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38252276

RESUMEN

OBJECTIVE: We aimed to evaluate the mitral valve calcification and mitral structure detected by cardiac computed tomography (cardiac CT) and establish a scoring model based on cardiac CT and clinical factors to predict early good mitral valve repair (EGMR) and guide surgical strategy in rheumatic mitral disease (RMD). MATERIALS AND METHODS: This is a retrospective bi-center cohort study. Based on cardiac CT, mitral valve calcification and mitral structure in RMD were quantified and evaluated. The primary outcome was EGMR. A logical regression algorithm was applied to the scoring model. RESULTS: A total of 579 patients were enrolled in our study from January 1, 2019, to August 31, 2022. Of these, 443 had baseline cardiac CT scans of adequate quality. The calcification quality score, calcification and thinnest part of the anterior leaflet clean zone, and papillary muscle symmetry were the independent CT factors of EGMR. Coronary artery disease and pulmonary artery pressure were the independent clinical factors of EGMR. Based on the above six factors, a scoring model was established. Sensitivity = 95% and specificity = 95% were presented with a cutoff value of 0.85 and 0.30 respectively. The area under the receiver operating characteristic of external validation set was 0.84 (95% confidence interval [CI] 0.73-0.93). CONCLUSIONS: Mitral valve repair is recommended when the scoring model value > 0.85 and mitral valve replacement is prior when the scoring model value < 0.30. This model could assist in guiding surgical strategies for RMD. CLINICAL RELEVANCE STATEMENT: The model established in this study can serve as a reference indicator for surgical repair in rheumatic mitral valve disease. KEY POINTS: • Cardiac CT can reflect the mitral structure in detail, especially for valve calcification. • A model based on cardiac CT and clinical factors for predicting early good mitral valve repair was established. • The developed model can help cardiac surgeons formulate appropriate surgical strategies.


Asunto(s)
Válvula Mitral , Cardiopatía Reumática , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/cirugía , Estudios Retrospectivos , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Adulto , Valor Predictivo de las Pruebas , Estudios de Cohortes
9.
Circ J ; 88(4): 510-516, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37438144

RESUMEN

BACKGROUND: Renal congestion is a potential prognostic factor in patients with heart failure and recently, assessment has become possible with intrarenal Doppler ultrasonography (IRD). The association between renal congestion assessed by IRD and outcomes after mitral transcatheter edge-to-edge repair (TEER) is unknown, so we aimed to clarify renal congestion and its prognostic implications in patients with mitral regurgitation (MR) who underwent TEER using MitraClip system.Methods and Results: Patients with secondary MR who underwent TEER and were assessed for intrarenal venous flow (IRVF) by IRD were classified according to their IRVF pattern as continuous or discontinuous. Of the 105 patients included, 78 patients (74%) formed the continuous group and 27 (26%) were the discontinuous group. Kaplan-Meier analysis revealed significant prognostic power of the IRVF pattern for predicting the composite outcome of all-cause death and heart failure rehospitalization (log-rank P=0.0257). On multivariate Cox regression analysis, the composite endpoint was independently associated with the discontinuous IRVF pattern (hazard ratio, 3.240; 95% confidence interval, 1.300-8.076; P=0.012) adjusted using inverse probability of treatment weighting. CONCLUSIONS: IRVF patterns strongly correlated with clinical outcomes without changes in renal function. Thus, they may be useful for risk stratification after mitral TEER for patients with secondary MR.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Angiografía , Insuficiencia Cardíaca/diagnóstico por imagen , Estimación de Kaplan-Meier , Riñón/diagnóstico por imagen , Resultado del Tratamiento
10.
Circ J ; 2024 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-39183037

RESUMEN

BACKGROUND: There is concern about the durability of mitral valve repair (MVr) for mitral regurgitation (MR) in Marfan patients due to limited long-term data. Furthermore, a detailed time course of changes in cardiac function after MVr in Marfan patients has not been reported. We examined repair techniques, postoperative cardiac function, and outcomes of MVr in Marfan patients. METHODS AND RESULTS: We retrospectively reviewed 29 Marfan patients (mean [±SD] age 27.4±14.8 years) who underwent MVr at The University of Tokyo Hospital from 2010 to 2022. The mean follow-up period was 5.2±3.2 years. The causes of MR were isolated anterior leaflet prolapse in 25% of patients, isolated posterior leaflet prolapse in 11%, and bileaflet prolapse in 64%. Echocardiographic findings showed significant decreases in left ventricular (LV) diastolic and left atrial diameters 1 week after MVr. LV systolic diameter was significantly decreased 3 years after MVr, and LV ejection fraction initially declined before subsequently increasing. The in-hospital and 30-day mortality rates were 0%. At 5 years, the overall survival rate was 94% and the rate of freedom from MR was 84%. CONCLUSIONS: The mid- to long-term outcomes after MVr in Marfan patients were satisfactory, supporting the durability of MVr in these patients. Postoperative cardiac reverse remodeling occurred in a phased manner in Marfan patients, similar to that in patients with degenerative MR.

11.
Circ J ; 88(4): 531-538, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38008428

RESUMEN

BACKGROUND: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).Methods and Results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11-1.32; P=0.13). CONCLUSIONS: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Modelos de Riesgos Proporcionales , Cateterismo Cardíaco
12.
Circ J ; 88(4): 568-578, 2024 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-38281764

RESUMEN

BACKGROUND: When mitral valve (MV) surgery is indicated, repair is preferred over replacement; however, this preference is not supported by evidence from clinical trials. Furthermore, the benefits of MV repair may not be universal for all etiologies of MV disease. METHODS AND RESULTS: This study identified a total of 18,428 patients who underwent MV repair (n=4,817) or MV replacement (n=13,611) during 2001-2018 from Taiwan's National Health Insurance Research Database. These patients were classified into 4 etiologies: infective endocarditis (IE, n=2,678), rheumatic heart disease (RHD, n=4,524), ischemic mitral regurgitation (IMR, n=3,893), and degenerative mitral regurgitation (DMR, n=7,333). After propensity matching, all-cause mortality during follow-up was lower among patients receiving MV repair than among patients receiving MV replacement in the IE, IMR, and DMR groups (hazard ratio [HR]=0.72, 95% confidence interval [CI]: 0.55-0.93; HR=0.82, 95% CI: 0.73-0.92; and HR 0.73, 95% CI: 0.64-0.84, respectively). However, in the RHD group, the MV reoperation rate was higher after MV repair than after MV replacement (subdistribution HR=1.91, 95% CI: 1.02-3.55). CONCLUSIONS: In comparison with MV replacement, MV repair was associated with a lower late mortality in patients with IE, IMR, and DMR, and a higher risk of reoperation in patients with RHD.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cardiopatía Reumática , Humanos , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/cirugía , Estudios de Cohortes , Resultado del Tratamiento
13.
Scand Cardiovasc J ; 58(1): 2347293, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38832868

RESUMEN

OBJECTIVES: Minimally invasive cardiac surgery techniques are increasingly used but have longer cardiopulmonary bypass time, which may increase inflammatory response and negatively affect coagulation. Our aim was to compare biomarkers of inflammation and coagulation as well as transfusion rates after minimally invasive mitral valve repair and mitral valve surgery using conventional sternotomy. DESIGN: A prospective non-randomized study was performed enrolling 71 patients undergoing mitral valve surgery (35 right mini-thoracotomy and 36 conventional sternotomy procedures). Blood samples were collected pre- and postoperatively to assess inflammatory response. Thromboelastometry (ROTEM) was performed to assess coagulation, and transfusion rates were monitored. RESULTS: The minimally invasive group had longer cardiopulmonary bypass times compared to the sternotomy group: 127 min ([115-146] vs 79 min [65-112], p < 0.001) and were cooled to a lower temperature during cardiopulmonary bypass, 34 °C vs 36 °C (p = 0.04). IL-6 was lower in the minimally invasive group compared to the conventional sternotomy group when measured at the end of the surgical procedure, (38 [23-69] vs 61[41-139], p = 0.008), but no differences were found at postoperative day 1 or postoperative day 3. The transfusion rate was lower in the minimally invasive group (14%) compared to full sternotomy (35%, p = 0.04) and the chest tube output was reduced, (395 ml [190-705] vs 570 ml [400-1040], p = 0.04). CONCLUSIONS: Our data showed that despite the longer use of extra corporal circulation during surgery, minimally invasive mitral valve repair is associated with reduced inflammatory response, lower rates of transfusion, and reduced chest tube output.


Asunto(s)
Biomarcadores , Coagulación Sanguínea , Transfusión Sanguínea , Puente Cardiopulmonar , Mediadores de Inflamación , Válvula Mitral , Esternotomía , Toracotomía , Humanos , Estudios Prospectivos , Femenino , Masculino , Biomarcadores/sangre , Persona de Mediana Edad , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Mediadores de Inflamación/sangre , Puente Cardiopulmonar/efectos adversos , Anciano , Resultado del Tratamiento , Factores de Tiempo , Esternotomía/efectos adversos , Toracotomía/efectos adversos , Tromboelastografía , Interleucina-6/sangre , Inflamación/sangre , Inflamación/etiología , Inflamación/diagnóstico , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/sangre , Factores de Riesgo
14.
Heart Vessels ; 39(3): 252-265, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37843552

RESUMEN

This study retrospectively evaluated the mid-term outcomes of surgical aortic valve replacement (SAVR) using a stented porcine aortic valve bioprosthesis (Mosaic; Medtronic Inc., Minneapolis, MN, USA) with concomitant mitral valve (MV) repair. From 1999 to 2014, 157 patients (median [interquartile range] age, 75 [70-79] years; 47% women) underwent SAVR with concomitant MV repair (SAVR + MV repair), and 1045 patients (median [interquartile range] age, 76 [70-80] years; 54% women) underwent SAVR only at 10 centers in Japan as part of the long-term multicenter Japan Mosaic valve (J-MOVE) study. The 5-year overall survival rate was 81.5% ± 4.1% in the SAVR + MV repair group and 85.1% ± 1.4% in the SAVR only group, and the 8-year overall survival rates were 75.2% ± 5.7% and 78.1% ± 2.1%, respectively. Cox proportional hazards analysis showed no significant difference in the survival rates between the two groups (hazard ratio, 0.87; 95% confidence interval, 0.54-1.40; P = 0.576). Among women with mild or moderate mitral regurgitation who were not receiving dialysis, those who underwent SAVR + MV repair, were aged > 75 years, and had a preoperative left ventricular ejection fraction of 30-75% tended to have a lower mortality risk. In conclusion, this subgroup analysis of the J-MOVE cohort showed relevant mid-term outcomes after SAVR + MV repair.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Femenino , Porcinos , Animales , Anciano , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Volumen Sistólico , Estudios Retrospectivos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Función Ventricular Izquierda , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo
15.
J Artif Organs ; 27(1): 57-64, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36752993

RESUMEN

The AtriClip device enables the safe and reproducible epicardial clipping of the left atrial appendage. Transapical off-pump beating heart mitral valve repair using NeoChord DS100 Artificial Chordae Delivery System has matured and become more standardized. We aim to evaluate the feasibility of combining NeoChord repair and left atrial appendage exclusion in a single procedure through the same minithoracotomy in patients with mitral valve prolapse and atrial fibrillation. From 2018 to 2019, seven patients with severe mitral regurgitation and atrial fibrillation underwent transesophageal echocardiography-guided transapical off-pump mitral valve repair with the novel NeoChord DS 1000 system and concomitant left atrial appendage exclusion using the AtriClip Pro II device. Both procedures were performed via left mini-thoracotomy. The AtriClip device was applied after the NeoChord repair was done. All seven patients had less than moderate mitral regurgitation after the NeoChord repair and successful left atrial appendage occlusion. There were no device or procedure-related complications. Clinical follow-up revealed significant symptomatic improvement, and no cardiovascular complications were reported. Transesophageal echocardiography at 6-12 months post-procedure showed stable left atrial appendage occlusion with no residual flow between the left atrium and the left atrial appendage and a stump of less than 5 mm. Beating heart epicardial clipping of the left atrial appendage using AtriClip concomitant with transapical mitral valve repair using Neochord DS 1000 system is a feasible and safe treatment option in mitral valve prolapse and atrial fibrillation in patients with limited indications. However, its safety needs to be confirmed in a larger series of patients.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/complicaciones , Prolapso de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Estudios de Factibilidad , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Resultado del Tratamiento , Cuerdas Tendinosas
16.
J Electrocardiol ; 84: 65-69, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537455

RESUMEN

BACKGROUND: Preoperative left ventricular (LV) ejection fraction (PreLVEF) and preoperative LV end-systolic diameter (PreESD) are known predictors for postoperative LV dysfunction after mitral valve repair (MVR). Fragmented QRS (fQRS) evaluated in 12-derivation electrocardiography has widely been accepted as a sign of myocardial fibrosis. In the present study, we aimed to evaluate the relationship between fQRS in preoperative 12­lead electrocardiography (ECG) and postoperative LV dysfunction that develop after MVR in patients with severe primary mitral regurgitation (MR) due to mitral valve prolapse (MVP). METHODS: From 2019 to 2022, 49 patients who had undergone successful MVR surgery for severeMR caused by MVP were enrolled in the study. The preoperative and postoperative echocardiographic data were collected retrospectively. We analyzed the demographic, echocardiographic, operative and postoperative parameters to assess the relationship between fQRS and early postoperative LV dysfunction, defined as an LVEF<60%. RESULTS: PreLVEF of all patients were ≥ %65. A total of 22 patients had fQRS (44.9%) and postoperative LV dysfunction was found to be 36.7%. A significantly higher rate of fQRS was observed in the group with postoperative LV dysfunction compared to the group without (12 (66.7%) vs 10 (32.3%), p: 0.036). In multivariate analysis for fQRS, PreESD, preoperative pulmonary artery systolic pressure (PrePASP), preoperative atrial fibrillation (PreAF), and male gender, only fQRS was found to be a significant predictor of postoperative LV dysfunction (p: 0.003, OR: 4.28, 95% CI (1.15-15.96). CONCLUSION: fQRS was found to be a predictor of postoperative LV dysfunction in the early period after MVR. fQRS may be a readily available and cost-effective test that can be used in clinical practice to predict postoperative LV dysfunction in patients undergoing MVR.


Asunto(s)
Electrocardiografía , Insuficiencia de la Válvula Mitral , Complicaciones Posoperatorias , Disfunción Ventricular Izquierda , Humanos , Masculino , Femenino , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/etiología , Persona de Mediana Edad , Estudios Retrospectivos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Ecocardiografía , Prolapso de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Volumen Sistólico
17.
Cardiol Young ; 34(1): 198-200, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37953639

RESUMEN

Submitral aneurysm is a rare type of non-ischaemic ventricular aneurysm. We describe the case of a 26-year-old woman with progressive dyspnoea for approximately 1 year who was diagnosed with a ruptured submitral aneurysm in the left atrium with severe regurgitation. The patient underwent aneurysm correction and mitral valve repair, and post-operative echocardiography showed no residual abnormalities. The patient remains asymptomatic.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Aneurisma Cardíaco , Insuficiencia de la Válvula Mitral , Femenino , Humanos , Adulto , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Ventrículos Cardíacos/cirugía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Aneurisma Cardíaco/diagnóstico por imagen , Aneurisma Cardíaco/cirugía
18.
Perfusion ; : 2676591241237130, 2024 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-38430242

RESUMEN

INTRODUCTION: In recent years, major findings on concomitant procedures and anticoagulation management have occurred in Mitral Valve (MV) surgery. Therefore, we sought to evaluate the current practices in MV interventions across Europe. METHODS: In October 2021, all national cardio-thoracic societies in the European region were identified following an electronic search and sent an online survey of 14 questions to distribute among their member consultant/attending cardiac surgeons. RESULTS: The survey was completed by 91 consultant/attending cardiac surgeons across 12 European countries, with 78% indicating MV repair as their specialty area. 57.1% performed >150 operations/year and 71.4% had 10+ years of experience.Concomitant tricuspid valve repair is performed for moderate tricuspid regurgitation (TR) by 69% of surgeons and for mild TR by 26.3%, both with annular diameter >40 mm. 50.6% indicated ischaemic MV surgery in patients undergoing CABG if moderate mitral regurgitation with ERO >20 mm2 and regurgitant volume >30 mL, and 45.1% perform it if severe MR with ERO >40 mm2 and regurgitant volume >60 mL. For these patients the preferred management was: MVR if predictors of repair failure identified (47.2%) and downsizing annuloplasty ring only (34.1%).For atrial fibrillation (AF) in cardiac surgery, 34.1% perform ablation with biatrial lesion and 20% with left sided only. 62.6% perform concomitant Left Atrial Appendage (LAA) Occlusion irrespective of AF ablation with a left atrial clip. A wide variability in anticoagulation strategies for MV repair and bioprosthetic MV valve was reported both for patients in sinus rhythm and AF. CONCLUSION: These results demonstrate a variable practice for MV surgery, and a degree of lack of compliance with surgical intervention guidelines and anticoagulation strategy.

19.
J Clin Ultrasound ; 52(1): 92-94, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37997479

RESUMEN

Diminutive posterior mitral valve leaflet with an extremely elongated anterior leaflet is a rare phenomenon. We share such a case discovered in an 82-year-old patient with severe, symptomatic mitral regurgitation. LA, left atrium; LV, left ventricle; MR, mitral regurgitation.


Asunto(s)
Insuficiencia de la Válvula Mitral , Válvula Mitral , Humanos , Anciano de 80 o más Años , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Ventrículos Cardíacos , Atrios Cardíacos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
20.
J Clin Ultrasound ; 52(4): 385-393, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38344863

RESUMEN

BACKGROUND: The association between surgical treatment of mitral regurgitation (MR) and renal function is not sufficiently well-known. We tried to evaluate renal function before and after the procedure of surgical mitral valve repair (SMVR) in degenerative severe MR. METHODS: Patients with primary severe (4+) MR and normal left ventricular ejection fraction (LVEF) that underwent SMVR, examined by a cutting-edge 3-dimensional (3D) echocardiographic probe were enrolled in this study. We took three CKD-EPI equations to measure estimated glomerular filtration rate (eGFR) before SMVR and shortly before patients discharge. A total of 40 patients with baseline lower mean eGFR were evaluated. RESULTS: Measurements substantiated statistically significant improvements in eGFR (p < 0.001), multivariable linear regression modeling indicating prominent associations between increase in eGFR and decrease of MR (p = 0.003), decline of pulmonary arterial systolic pressure (p = 0.018), as well as increment of forward stroke volume (p = 0.02), in spite of LVEF reduction, left ventricular global longitudinal strain worsening and left atrial ejection fraction impairment. CONCLUSIONS: Renal function improves after SMVR in patients with degenerative significant MR and preserved LVEF, regardless of cardiac functional worsening.


Asunto(s)
Ecocardiografía Tridimensional , Tasa de Filtración Glomerular , Insuficiencia de la Válvula Mitral , Válvula Mitral , Humanos , Femenino , Masculino , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Ecocardiografía Tridimensional/métodos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Resultado del Tratamiento , Riñón/diagnóstico por imagen , Riñón/fisiopatología , Riñón/cirugía , Anciano , Volumen Sistólico/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA