Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 482
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
BMC Musculoskelet Disord ; 25(1): 787, 2024 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-39367310

RESUMEN

BACKGROUND: A robotic arm-assisted and a computed tomography (CT)- based navigation system have been reported to improve the accuracy of component positioning in total hip arthroplasty (THA). However, no study has compared robotic arm-assisted THA (rTHA) to CT-based navigated THA (nTHA) concerning accuracy of cup placement and acetabular fractures using the direct anterior approach (DAA). This study aimed to compare the accuracy of cup placement and the presence of intraoperative acetabular fractures between rTHA and nTHA using DAA in the supine position. METHODS: We retrospectively investigated 209 hips of 188 patients who underwent rTHA or nTHA using DAA (rTHA using the Mako system: 85 hips of 79 patients; nTHA: 124 hips of 109 patients). After propensity score matching for age and sex, each group consisted of 73 hips. We evaluated clinical and radiographic outcomes, comparing postoperative cup orientation and position, measured using a three-dimensional templating software, to preoperative CT planning. Additionally, we investigated the prevalence of occult acetabular fracture. RESULTS: Clinical outcomes were not significantly different between the groups at 1 year postoperatively. The mean absolute error of cup orientation was significantly smaller in the rTHA group than in nTHA (inclination: 1.4° ± 1.2° vs. 2.7° ± 2.2°, respectively; p = 0.0001, anteversion: 1.5° ± 1.3° vs. 2.2° ± 1.7°, respectively; p = 0.007). The cases within an absolute error of 5 degrees in both RI and RA were significantly higher in the rTHA (97.3%) than in nTHA group (82.2%) (p = 0.003). The absolute error of the cup position was not significantly different between the two groups. The prevalence of occult acetabular fracture did not differ significantly between the two groups (rTHA: n = 0 [0%] vs. nTHA: n = 1 [1.4%]). CONCLUSION: Cup placement using DAA in the supine position in rTHA was more accurate with fewer outliers compared to nTHA. Therefore, rTHA performed via DAA in a supine position would be useful for accurate cup placement.


Asunto(s)
Acetábulo , Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Tomografía Computarizada por Rayos X , Humanos , Estudios Retrospectivos , Femenino , Masculino , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/efectos adversos , Anciano , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Acetábulo/cirugía , Acetábulo/diagnóstico por imagen , Cirugía Asistida por Computador/métodos , Resultado del Tratamiento , Anciano de 80 o más Años
2.
J Arthroplasty ; 39(8S1): S218-S223, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38417556

RESUMEN

BACKGROUND: Optimal soft-tissue management in total knee arthroplasty (TKA) may reduce symptomatic instability. We hypothesized that TKA outcomes using a computer-assisted dynamic ligament balancer that acquires medial and lateral gap sizes throughout the motion arc would show improved Knee Society Scores (KSS) compared to TKAs done with a traditional tensioner at 0 and 90°. We also sought to quantify the degree to which the planned femoral rotation chosen to optimize medio-lateral balance throughout the arc of motion deviated from the femoral rotation needed to achieve a rectangular flexion gap at 90° alone. METHODS: Baseline demographics, clinical outcomes, KSSs, and femoral rotations were compared in 100 consecutive, computer-assisted TKAs done with the balancer (balancer group) to the immediately prior 100 consecutive computer-assisted TKAs done without the balancer (control group). Minimum follow-up was 13 months and all patients had osteoarthritis. Mean knee motion did not differ preoperatively (110.1 ± 13.6° balancer, 110.4 ± 12.5° control, P = .44) or postoperatively (119.1 ± 10.3° balancer, 118.8 ± 10.9° control, P = .42). Tourniquet times did not differ (93.1 ± 13.0 minutes balancer, 90.7 ± 13.0 minutes control, P = .13). Postoperative length of stay differed (40.2 ± 20.9 hours balancer, 49.0 ± 18.3 hours control, P = .0009). There were 14 readmissions (7 balancer, 7 control), 11 adverse events (4 balancer, 7 control), and 3 manipulations (1 balancer, 2 control). The cohorts were compared using Student's t-tests, Shapiro-Wilk normalities, Wilcoxon rank-sums, and multivariable logistic regression analyses. RESULTS: Postoperative KSS improvements were higher in the balancer group (P < .0001). In multivariable regression analyses, the balancer group experienced 7 ± 2 point improvement in KSS Knee scores (P < .0001) and 4 ± 2 point improvement in KSS Function scores (P = .040) compared to the control group. CONCLUSIONS: The statistically and clinically significant improvements in postoperative KSS demonstrated in the balancer cohort are likely driven by improved stability throughout the motion arc. Further study is warranted to evaluate replicability by non-design surgeons.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla , Osteoartritis de la Rodilla , Rango del Movimiento Articular , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/cirugía , Cirugía Asistida por Computador/métodos , Estudios Retrospectivos , Inestabilidad de la Articulación/cirugía , Inestabilidad de la Articulación/prevención & control , Anciano de 80 o más Años , Fenómenos Biomecánicos
3.
Sensors (Basel) ; 24(16)2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39205058

RESUMEN

Electromagnetic tracking (EMT) can benefit image-guided interventions in cases where line of sight is unavailable. However, EMT can suffer from electromagnetic distortion in the presence of metal instruments. Metal instruments are widely used in laparoscopic surgery, ENT surgery, arthroscopy and many other clinical applications. In this work, we investigate the feasibility of tracking such metal instruments by placing the inductive sensor within the instrument shaft. We propose a magnetostatic model of the field within the instrument, and verify the results experimentally for frequencies from 6 kHz to 60 kHz. The impact of the instrument's dimensions, conductivity and transmitting field frequency is quantified for ranges representative of typical metal instruments used in image-guided interventions. We then performed tracking using the open-source Anser EMT system and quantify the error caused by the presence of the rod as a function of the frequency of the eight emitting coils for the system. The work clearly demonstrates why smaller tool diameters (less than 8 mm) are less susceptible to distortion, as well as identifying optimal frequencies (1 kHz to 2 kHz) for transmitter design to minimise for distortion in larger instruments.


Asunto(s)
Metales , Metales/química , Humanos , Cirugía Asistida por Computador/métodos , Cirugía Asistida por Computador/instrumentación , Magnetismo/instrumentación , Diseño de Equipo , Campos Electromagnéticos
4.
Sensors (Basel) ; 24(14)2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39066150

RESUMEN

Periacetabular osteotomy (PAO) is an effective approach for the surgical treatment of developmental dysplasia of the hip (DDH). However, due to the complex anatomical structure around the hip joint and the limited field of view (FoV) during the surgery, it is challenging for surgeons to perform a PAO surgery. To solve this challenge, we propose a robot-assisted, augmented reality (AR)-guided surgical navigation system for PAO. The system mainly consists of a robot arm, an optical tracker, and a Microsoft HoloLens 2 headset, which is a state-of-the-art (SOTA) optical see-through (OST) head-mounted display (HMD). For AR guidance, we propose an optical marker-based AR registration method to estimate a transformation from the optical tracker coordinate system (COS) to the virtual space COS such that the virtual models can be superimposed on the corresponding physical counterparts. Furthermore, to guide the osteotomy, the developed system automatically aligns a bone saw with osteotomy planes planned in preoperative images. Then, it provides surgeons with not only virtual constraints to restrict movement of the bone saw but also AR guidance for visual feedback without sight diversion, leading to higher surgical accuracy and improved surgical safety. Comprehensive experiments were conducted to evaluate both the AR registration accuracy and osteotomy accuracy of the developed navigation system. The proposed AR registration method achieved an average mean absolute distance error (mADE) of 1.96 ± 0.43 mm. The robotic system achieved an average center translation error of 0.96 ± 0.23 mm, an average maximum distance of 1.31 ± 0.20 mm, and an average angular deviation of 3.77 ± 0.85°. Experimental results demonstrated both the AR registration accuracy and the osteotomy accuracy of the developed system.


Asunto(s)
Realidad Aumentada , Osteotomía , Procedimientos Quirúrgicos Robotizados , Cirugía Asistida por Computador , Osteotomía/métodos , Osteotomía/instrumentación , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Procedimientos Quirúrgicos Robotizados/instrumentación , Cirugía Asistida por Computador/métodos , Acetábulo/cirugía
5.
Surg Innov ; 31(1): 48-57, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38019844

RESUMEN

BACKGROUND: Computer assisted surgical navigation systems are designed to improve outcomes by providing clinicians with procedural guidance information. The use of new technologies, such as mixed reality, offers the potential for more intuitive, efficient, and accurate procedural guidance. The goal of this study is to assess the positional accuracy and consistency of a clinical mixed reality system that utilizes commercially available wireless head-mounted displays (HMDs), custom software, and localization instruments. METHODS: Independent teams using the second-generation Microsoft HoloLens© hardware, Medivis SurgicalAR© software, and localization instruments, tested the accuracy of the combined system at different institutions, times, and locations. The ASTM F2554-18 consensus standard for computer-assisted surgical systems, as recognized by the U.S. FDA, was utilized to measure the performance. 288 tests were performed. RESULTS: The system demonstrated consistent results, with an average accuracy performance that was better than one millimeter (.75 ± SD .37 mm). CONCLUSION: Independently acquired positional tracking accuracies exceed conventional in-market surgical navigation tracking systems and FDA standards. Importantly, the performance was achieved at two different institutions, using an international testing standard, and with a system that included a commercially available off-the-shelf wireless head mounted display and software.


Asunto(s)
Realidad Aumentada , Cirugía Asistida por Computador , Estados Unidos , Cirugía Asistida por Computador/métodos , Sistemas de Navegación Quirúrgica , United States Food and Drug Administration , Programas Informáticos
6.
Arch Orthop Trauma Surg ; 144(3): 1077-1089, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38133802

RESUMEN

INTRODUCTION: The periacetabular osteotomy is a technically demanding procedure with the goal to improve the osseous containment of the femoral head. The options for controlled execution of the osteotomies and verification of the acetabular reorientation are limited. With the assistance of augmented reality, new possibilities are emerging to guide this intervention. However, the scientific knowledge regarding AR navigation for PAO is sparse. METHODS: In this cadaveric study, we wanted to find out, if the execution of this complex procedure is feasible with AR guidance, quantify the accuracy of the execution of the three-dimensional plan, and find out what has to be done to proceed to real surgery. Therefore, an AR guidance for the PAO was developed and applied on 14 human hip cadavers. The guidance included performance of the four osteotomies and reorientation of the acetabular fragment. The osteotomy starting points, the orientation of the osteotomy planes, as well as the reorientation of the acetabular fragment were compared to the 3D planning. RESULTS: The mean 3D distance between planned and performed starting points was between 9 and 17 mm. The mean angle between planned and performed osteotomies was between 6° and 7°. The mean reorientation error between the planned and performed rotation of the acetabular fragment was between 2° and 11°. CONCLUSION: The planned correction can be achieved with promising accuracy and without serious errors. Further steps for a translation from the cadaver to the patient have been identified and must be addressed in future work.


Asunto(s)
Realidad Aumentada , Humanos , Estudios de Factibilidad , Acetábulo/cirugía , Osteotomía/métodos , Cadáver
7.
Arch Orthop Trauma Surg ; 144(6): 2811-2821, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38704436

RESUMEN

BACKGROUND: The use of portable navigation systems (PNS) in total hip arthroplasty (THA) has become increasingly prevalent, with second-generation PNS (sPNS) demonstrating superior accuracy in the lateral decubitus position compared to first-generation PNS. However, few studies have compared different types of sPNS. This study retrospectively compares the accuracy and clinical outcomes of two different types of sPNS instruments in patients undergoing THA. METHODS: A total of 158 eligible patients who underwent THA at a single institution between 2019 and 2022 were enrolled in the study, including 89 who used an accelerometer-based PNS with handheld infrared stereo cameras in the Naviswiss group (group N) and 69 who used an augmented reality (AR)-based PNS in the AR-Hip group (group A). Accuracy error, navigation error, clinical outcomes, and preparation time were compared between the two groups. RESULTS: Accuracy errors for Inclination were comparable between group N (3.5° ± 3.0°) and group A (3.5° ± 3.1°) (p = 0.92). Accuracy errors for anteversion were comparable between group N (4.1° ± 3.1°) and group A (4.5° ± 4.0°) (p = 0.57). The navigation errors for inclination (group N: 2.9° ± 2.7°, group A: 3.0° ± 3.2°) and anteversion (group N: 4.3° ± 3.5°, group A: 4.3° ± 4.1°) were comparable between the groups (p = 0.86 and 0.94, respectively). The preparation time was shorter in group A than in group N (p = 0.036). There were no significant differences in operative time (p = 0.255), intraoperative blood loss (p = 0.387), or complications (p = 0.248) between the two groups. CONCLUSION: An Accelerometer-based PNS using handheld infrared stereo cameras and AR-based PNS provide similar accuracy during THA in the lateral decubitus position, with a mean error of 3°-4° for both inclination and anteversion, though the AR-based PNS required a shorter preparation time.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Realidad Aumentada , Cirugía Asistida por Computador , Sistemas de Navegación Quirúrgica , Humanos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Estudios Retrospectivos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Cirugía Asistida por Computador/métodos , Cirugía Asistida por Computador/instrumentación , Rayos Infrarrojos
8.
BMC Oral Health ; 24(1): 88, 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38229117

RESUMEN

OBJECTIVE: The aim of this study was to present an innovative surgical protocol, navigation-based endoscopic enucleation (NBEE) for the treatment of large mandibular cystic lesions involving the mandibular ramus. METHODS: Twelve patients who presented with a large mandibular cystic lesion involving the mandibular ramus were enrolled in this study. Preoperative planning and intraoperative navigation were performed in all 12 patients. RESULTS: All patients in this study were treated with navigation-based endoscopic enucleation successfully. The follow-up period ranged from 7 to 10 months. Bone regenerated was found in all patients postoperatively. Three patients experienced temporary mandibular nerve palsy, and all relieved within 2 months. No pathological bone fracture was found during surgery. CONCLUSIONS: The use of navigation-based endoscopic enucleation (NBEE) for the treatment of large mandibular cystic lesions involving the ramus proved to be an effective method for complete and precise enucleation of the cystic lesion that also preserved the surrounding tissue.


Asunto(s)
Endoscopía , Mandíbula , Humanos , Mandíbula/cirugía , Endoscopía/métodos , Osteotomía/métodos
9.
BMC Oral Health ; 24(1): 359, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38509530

RESUMEN

This systematic review explores the accuracy of computerized guided implant placement including computer-aided static, dynamic, and robot-assisted surgery. An electronic search up to February 28, 2023, was conducted using the PubMed, Embase, and Scopus databases using the search terms "surgery", "computer-assisted", "dynamic computer-assisted", "robotic surgical procedures", and "dental implants". The outcome variables were discrepancies including the implant's 3D-coronal, -apical and -angular deviations. Articles were selectively retrieved according to the inclusion and exclusion criteria, and the data were quantitatively meta-analysed to verify the study outcomes. Sixty-seven articles were finally identified and included for analysis. The accuracy comparison revealed an overall mean deviation at the entry point of 1.11 mm (95% CI: 1.02-1.19), and 1.40 mm (95% CI: 1.31-1.49) at the apex, and the angulation was 3.51˚ (95% CI: 3.27-3.75). Amongst computerized guided implant placements, the robotic system tended to show the lowest deviation (0.81 mm in coronal deviation, 0.77 mm in apical deviation, and 1.71˚ in angular deviation). No significant differences were found between the arch type and flap operation in cases of dynamic navigation. The fully-guided protocol demonstrated a significantly higher level of accuracy compared to the pilot-guided protocol, but did not show any significant difference when compared to the partially guided protocol. The use of computerized technology clinically affirms that operators can accurately place implants in three directions. Several studies agree that a fully guided protocol is the gold standard in clinical practice.


Asunto(s)
Implantación Dental Endoósea , Procedimientos Quirúrgicos Robotizados , Cirugía Asistida por Computador , Humanos , Cirugía Asistida por Computador/métodos , Implantación Dental Endoósea/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Implantes Dentales , Ensayos Clínicos como Asunto
10.
Gen Dent ; 72(2): 60-64, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38411487

RESUMEN

This case report presents a challenging case of catastrophic failure of a fixed partial denture involving fracture of the prosthesis as well as supporting implants and teeth. The use of robotics facilitated efficient and successful restoration of the patient's dentition. After extraction of 2 fractured teeth and 1 fractured implant, 2 new implants were placed with haptic guidance from robotics, which allowed for stable osteotomies and high initial implant stability quotients. Due to the patient's tremors and heavy occlusal forces, restoration was delayed to allow the surgical site to heal, and the patient received a provisional partial denture. With subsequent placement of the final restoration, the treatment was fully completed in 4.5 months and required only a single surgical procedure. The use of haptic robotics in this case allowed for accurate planning, spacing, and placement of screw-retained implants with an optimal arch, leading to the best long-term outcome for the patient.


Asunto(s)
Implantes Dentales , Robótica , Fracturas de los Dientes , Humanos , Fuerza de la Mordida , Tornillos Óseos
11.
Minim Invasive Ther Allied Technol ; 33(3): 176-183, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38334755

RESUMEN

INTRODUCTION: The use of laparoscopic and robotic liver surgery is increasing. However, it presents challenges such as limited field of view and organ deformations. Surgeons rely on laparoscopic ultrasound (LUS) for guidance, but mentally correlating ultrasound images with pre-operative volumes can be difficult. In this direction, surgical navigation systems are being developed to assist with intra-operative understanding. One approach is performing intra-operative ultrasound 3D reconstructions. The accuracy of these reconstructions depends on tracking the LUS probe. MATERIAL AND METHODS: This study evaluates the accuracy of LUS probe tracking and ultrasound 3D reconstruction using a hybrid tracking approach. The LUS probe is tracked from laparoscope images, while an optical tracker tracks the laparoscope. The accuracy of hybrid tracking is compared to full optical tracking using a dual-modality tool. Ultrasound 3D reconstruction accuracy is assessed on an abdominal phantom with CT transformed into the optical tracker's coordinate system. RESULTS: Hybrid tracking achieves a tracking error < 2 mm within 10 cm between the laparoscope and the LUS probe. The ultrasound reconstruction accuracy is approximately 2 mm. CONCLUSION: Hybrid tracking shows promising results that can meet the required navigation accuracy for laparoscopic liver surgery.


Asunto(s)
Imagenología Tridimensional , Laparoscopía , Hígado , Fantasmas de Imagen , Ultrasonografía , Laparoscopía/métodos , Humanos , Imagenología Tridimensional/métodos , Ultrasonografía/métodos , Hígado/diagnóstico por imagen , Hígado/cirugía , Cirugía Asistida por Computador/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Procedimientos Quirúrgicos Robotizados/instrumentación , Sistemas de Navegación Quirúrgica , Laparoscopios
12.
Rozhl Chir ; 103(8): 305-312, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39313359

RESUMEN

INTRODUCTION: 3D printing, a concept over 40 years old, is finding broader application in clinical practice thanks to technological advancements. At University Hospital Ostrava, 3D printing is utilized to create anatomically accurate models of specific patients before surgical procedures based on imaging data. CASE SERIES: 3D printing is employed as a complement to conventional imaging methods to produce morphologically precise models of anatomical structures of individual patients. These models primarily serve for preoperative planning in elective abdominal, vascular, and thoracic surgery. They are also used in planning osteosynthesis of complex fractures and corrective osteotomies. Multicolor printing, although increasing the process's time demands, allows better clarity and differentiation of individual anatomical structures within a single model. DISCUSSION: Compared to 2D images, 3D models provide better spatial orientation and awareness of the operated structures, contributing to improved surgical outcomes. The benefits of 3D printing in preoperative planning and patient education are confirmed by studies across the fields ranging from cardiac surgery to traumatology. CONCLUSION: After overcoming initial challenges, 3D printing has become a reliable component of the surgical arsenal at University Hospital Ostrava for elective surgery. While 3D printing does not represent a universal answer to all medical challenges, its role is highly beneficial and promising in many indicated cases.


Asunto(s)
Impresión Tridimensional , Humanos , Modelos Anatómicos , Cuidados Preoperatorios
13.
Ann Surg Oncol ; 30(12): 7373-7383, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37606841

RESUMEN

BACKGROUND: Laparoscopic anatomical Segment 8 (S8) resection is a highly challenging hepatectomy. Augmented reality navigation (ARN), which could be combined with indocyanine green (ICG) fluorescence imaging, has been applied in various complex liver resections and may also be applied in laparoscopic anatomical S8 resection. However, no study has explored how to apply ARN plus ICG fluorescence imaging (ARN-FI) in laparoscopic anatomical S8 resection, or explored its accuracy. PATIENTS AND METHODS: This study is a post hoc analysis that included 31 patients undergoing laparoscopic anatomical S8 resection from the clinical NaLLRFI trial, and the resected liver volume was measured in each patient. The perioperative parameters of safety and feasibility, as well as the accuracy analysis outcomes were compared. RESULTS: There were 16 patients in the ARN-FI group and 15 patients underwent conventional laparoscopic hepatectomy without ARN or fluorescence imaging (non-ARN-FI group). There was no significant difference in baseline characteristics between the two groups. Compared with the non-ARN-FI group, the ARN-FI group had lower intraoperative bleeding (median 125 vs. 300 mL, P = 0.003). No significant difference was observed in other postoperative short-term outcomes. Accuracy analysis indicated that the actual resected liver volume (ARLV) in the ARN-FI group was more accurate. CONCLUSIONS: ARN-FI was associated with less intraoperative bleeding and more accurate resection volume. These techniques may address existing challenges and provide rational guidance for laparoscopic anatomical S8 resection.

14.
Periodontol 2000 ; 91(1): 89-112, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35906928

RESUMEN

Flapless and fully guided implant placement has the potential to maximize efficacy outcomes and at the same time to minimize surgical invasiveness. The aim of the current systematic review was to answer the following PICO question: "In adult human subjects undergoing dental implant placement (P), is minimally invasive flapless computer-aided fully guided (either dynamic or static computer-aided implant placement (sCAIP)) (I) superior to flapped conventional (free-handed implant placement (FHIP) or cast-based/drill partially guided implant placement (dPGIP)) surgery (C), in terms of efficacy, patient morbidity, long-term prognosis, and costs (O)?" Randomized clinical trials (RCTs) fulfilling specific inclusion criteria established to answer the PICO question were included. Two review authors independently searched for eligible studies, screened the titles and abstracts, performed full-text analysis, extracted the data from the published reports, and performed the risk of bias assessment. In cases of disagreement, a third review author took the final decision during ad hoc consensus meetings. The study results were summarized using random effects meta-analyses, which were based (wherever possible) on individual patient data (IPD). A total of 10 manuscripts reporting on five RCTs, involving a total of 124 participants and 449 implants, and comparing flapless sCAIP with flapped FHIP/cast-based partially guided implant placement (cPGIP), were included. There was no RCT analyzing flapless dynamic computer-aided implant placement (dCAIP) or flapped dPGIP. Intergroup meta-analyses indicated less depth deviation (difference in means (MD) = -0.28 mm; 95% confidence interval (CI): -0.59 to 0.03; moderate certainty), angular deviation (MD = -3.88 degrees; 95% CI: -7.00 to -0.77; high certainty), coronal (MD = -0.6 mm; 95% CI: -1.21 to 0.01; low certainty) and apical (MD = -0.75 mm; 95% CI: -1.43 to -0.07; moderate certainty) three-dimensional bodily deviations, postoperative pain (MD = -17.09 mm on the visual analogue scale (VAS); 95% CI: -33.38 to -0.80; low certainty), postoperative swelling (MD = -6.59 mm on the VAS; 95% CI: -19.03 to 5.85; very low certainty), intraoperative discomfort (MD = -9.36 mm on the VAS; 95% CI: -17.10 to -1.61) and surgery duration (MD = -24.28 minutes; 95% CI: -28.62 to -19.95) in flapless sCAIP than in flapped FHIP/cPGIP. Despite being more accurate than flapped FHIP/cPGIP, flapless sCAIP still resulted in deviations with respect to the planned position (intragroup meta-analytic means: 0.76 mm in depth, 2.57 degrees in angular, 1.43 mm in coronal, and 1.68 in apical three-dimensional bodily position). Moreover, flapless sCAIP presented a 12% group-specific intraoperative complication rate, resulting in an inability to place the implant with this protocol in 7% of cases. Evidence regarding more clinically relevant outcomes of efficacy (implant survival and success, prosthetically and biologically correct positioning), long-term prognosis, and costs, is currently scarce. When the objective is to guarantee minimal invasiveness at implant placement, clinicians could consider the use of flapless sCAIP. A proper case selection and consideration of a safety margin are, however, suggested.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Adulto , Humanos , Implantación Dental Endoósea/métodos , Colgajos Quirúrgicos
15.
Surg Endosc ; 37(10): 8156-8164, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37653158

RESUMEN

BACKGROUND: Right hemi-hepatectomy plus total caudate lobectomy is the appropriate procedure for type IIIa or partial type II pCCA. However, the laparoscopic implementation of this procedure remains technically challenging, especially hilar vascular dissection and en bloc resection of the total caudate lobe. Augmented reality navigation can provide intraoperative navigation to enhance visualization of invisible hilar blood vessels and guide the parenchymal transection plane. METHODS: Eleven patients who underwent laparoscopic right hemi-hepatectomy plus total caudate lobectomy from January 2021 to January 2023 were enrolled in this study. Augmented reality navigation technology and the anterior approach were utilized in this operation. Routine operative and short-term postoperative outcomes were assessed to evaluate the feasibility of the novel navigation method in this operation. RESULTS: Right hemi-hepatectomy plus total caudate lobectomy was successfully performed in all 11 enrolled patients. Among the 11 patients, the mean operation time was 454.5 ± 25.0 min and the mean estimated blood loss was 209.1 ± 56.1 ml. Negative surgical margins were achieved in all patients. The postoperative course of all the patients was uneventful, and the mean length of postoperative hospital stay was 10.5 ± 1.2 days. CONCLUSION: Laparoscopic right hemi-hepatectomy plus total caudate lobectomy via the anterior approach may be feasible and safe for pCCA with the assistance of augmented reality navigation.


Asunto(s)
Realidad Aumentada , Neoplasias de los Conductos Biliares , Colangiocarcinoma , Tumor de Klatskin , Laparoscopía , Neoplasias Hepáticas , Humanos , Tumor de Klatskin/cirugía , Hepatectomía/métodos , Estudios de Factibilidad , Neoplasias Hepáticas/cirugía , Laparoscopía/métodos , Neoplasias de los Conductos Biliares/cirugía , Neoplasias de los Conductos Biliares/patología , Colangiocarcinoma/cirugía
16.
Surg Endosc ; 37(9): 7083-7099, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37386254

RESUMEN

BACKGROUND: Surgical process model (SPM) analysis is a great means to predict the surgical steps in a procedure as well as to predict the potential impact of new technologies. Especially in complicated and high-volume treatments, such as parenchyma sparing laparoscopic liver resection (LLR), profound process knowledge is essential for enabling improving surgical quality and efficiency. METHODS: Videos of thirteen parenchyma sparing LLR were analyzed to extract the duration and sequence of surgical steps according to the process model. The videos were categorized into three groups, based on the tumor locations. Next, a detailed discrete events simulation model (DESM) of LLR was built, based on the process model and the process data obtained from the endoscopic videos. Furthermore, the impact of using a navigation platform on the total duration of the LLR was studied with the simulation model by assessing three different scenarios: (i) no navigation platform, (ii) conservative positive effect, and (iii) optimistic positive effect. RESULTS: The possible variations of sequences of surgical steps in performing parenchyma sparing depending on the tumor locations were established. The statistically most probable chain of surgical steps was predicted, which could be used to improve parenchyma sparing surgeries. In all three categories (i-iii) the treatment phase covered the major part (~ 40%) of the total procedure duration (bottleneck). The simulation results predict that a navigation platform could decrease the total surgery duration by up to 30%. CONCLUSION: This study showed a DESM based on the analysis of steps during surgical procedures can be used to predict the impact of new technology. SPMs can be used to detect, e.g., the most probable workflow paths which enables predicting next surgical steps, improving surgical training systems, and analyzing surgical performance. Moreover, it provides insight into the points for improvement and bottlenecks in the surgical process.


Asunto(s)
Laparoscopía , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/cirugía , Hepatectomía/métodos , Laparoscopía/métodos , Tiempo de Internación
17.
Clin Oral Implants Res ; 34(5): 438-449, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36794798

RESUMEN

OBJECTIVES: To assess dental implant placement accuracy with a dynamic computer-assisted implant surgery (dCAIS) system and a freehand approach. Secondarily, to compare the patients' perception and quality of life (QoL) with the two approaches. METHODS: A double-arm randomized clinical trial was conducted. Consecutive partially edentulous patients were randomly allocated to the dCAIS or standard freehand approach groups. Implant placement accuracy was evaluated by overlapping the preoperative and postoperative Cone Beam Computer Tomographs (CBCT) and recording linear deviations at the implant apex and platform (in mm) and angular deviations (in degrees). Questionnaires recorded self-reported satisfaction, pain and QoL during surgery and postoperatively. RESULTS: Thirty patients (22 implants) were enrolled in each group. One patient was lost to follow-up. A significant difference (p < .001) in mean angular deviation was found between the dCAIS (4.02°; 95% CI: 2.85 to 5.19) and the FH (7.97°; 95% CI: 5.36 to 10.58) groups. Linear deviations were significantly lower in the dCAIS group, except for the apex vertical deviation, where no differences were found. Although dCAIS took 14 min longer (95% CI: 6.43 to 21.24; p < .001), patients in both groups considered the surgical time acceptable. Postoperative pain and analgesic consumption during the first postoperative week were similar between groups and self-reported satisfaction was very high. CONCLUSION: dCAIS systems significantly increase the accuracy of implant placement in partially edentulous patients in comparison with the conventional freehand approach. However, they increase the surgical time significantly and do not seem to improve patient satisfaction or reduce postoperative pain.


Asunto(s)
Implantes Dentales , Boca Edéntula , Cirugía Asistida por Computador , Humanos , Calidad de Vida , Implantación Dental Endoósea , Tomografía Computarizada de Haz Cónico , Dolor Postoperatorio/etiología , Dolor Postoperatorio/prevención & control , Diseño Asistido por Computadora , Imagenología Tridimensional
18.
Eur Spine J ; 32(10): 3425-3433, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37552327

RESUMEN

PURPOSE: Over the last years, interest and efforts to implement augmented reality (AR) in orthopedic surgery through head-mounted devices (HMD) have increased. However, the majority of experiments were preclinical and within a controlled laboratory environment. The operating room (OR) is a more challenging environment with various confounding factors potentially affecting the performance of an AR-HMD. The aim of this study was to assess the performance of an AR-HMD in a real-life OR setting. METHODS: An established AR application using the HoloLens 2 HMD was tested in an OR and in a laboratory by two users. The accuracy of the hologram overlay, the time to complete the trial, the number of rejected registration attempts, the delay in live overlay of the hologram, and the number of completely failed runs were recorded. Further, different OR setting parameters (light condition, setting up partitions, movement of personnel, and anchor placement) were modified and compared. RESULTS: Time for full registration was higher with 48 s (IQR 24 s) in the OR versus 33 s (IQR 10 s) in the laboratory setting (p < 0.001). The other investigated parameters didn't differ significantly if an optimal OR setting was used. Within the OR, the strongest influence on performance of the AR-HMD was different light conditions with direct light illumination on the situs being the least favorable. CONCLUSION: AR-HMDs are affected by different OR setups. Standardization measures for better AR-HMD performance include avoiding direct light illumination on the situs, setting up partitions, and minimizing the movement of personnel.


Asunto(s)
Realidad Aumentada , Humanos , Quirófanos
19.
Nanomedicine ; 50: 102671, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37054805

RESUMEN

OBJECTIVE: Perineural invasion (PNI) is associated with local recurrence, distant metastasis, and a poor prognosis in pancreatic cancer. However, rare attempt was made to identified the PNI intraoperative. To facilitate precise R0 excision of the tumor, we planned to develop a fluorescent probe for intraoperative imaging of the PNI using GAP-43 as the target and indocyanine green (ICG) as the carrier. METHODS: The probe was created by binding peptide antibody and ICG. Its targeting was tested in vitro and in vivo using a co-culture model of PC12 and tumor cells to create an in vitro neural invasion model and a mouse sciatic nerve invasion model. The small animal imaging system and surgical navigation system confirmed the probe's potential clinical applicability. The sciatic nerve damage model was created to confirm the probe's targeting. RESULTS: We used the pancreatic cancer samples and the public database to confirm that GAP-43 was preferentially overexpressed in pancreatic cancer, particularly in PNI. PC12 cells showed high GAP-43RA-PEG-ICG probe-specific absorption after being co-cultured with tumor cells in vitro. In the sciatic nerve invasion experiment, animals in probe group displayed a significantly stronger fluorescence signal at the PNI compared to ICG-NP and the contralateral normal nerves groups. Although only 60 % of mice appeared to have R0 resections by the naked eye, small animal imaging systems and surgical fluorescence navigation systems could remove the tumor with R0 precision. The injury model used in the probe imaging experimental trials demonstrated that the probe was specifically targeted to the injured nerve, regardless of whether the injury was infiltrated by a tumor or physical. CONCLUSION: We developed the GAP-43Ra-ICG-PEG, an active-targeting near-infrared fluorescent (NIRF) probe, that specifically binds to GAP-43-positive neural cells in an in vitro model of PNI. The probe efficiently visualized PNI lesions in pancreatic cancer in preclinical models, opening up new possibilities for NIRF-guided pancreatic surgery, particularly for PNI patients.


Asunto(s)
Verde de Indocianina , Neoplasias Pancreáticas , Ratas , Ratones , Animales , Colorantes Fluorescentes , Proteína GAP-43 , Neoplasias Pancreáticas/patología , Modelos Animales de Enfermedad , Neoplasias Pancreáticas
20.
J Arthroplasty ; 38(6S): S374-S378, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36828051

RESUMEN

BACKGROUND: The accuracy, precision, and repeatability by which the tibial sagittal plane can be found with imageless technology is currently unknown. The purpose of this study was to identify any differences between imageless and image-based technology to define the sagittal plane of the tibia. METHODS: A computed tomography (CT) was obtained of 18 cadavers with the knee fully extended. The surgical trans-epicondylar axis and several tibial rotation references were acquired on the CT scan. After a medial parapatellar approach, the same anatomical landmarks were acquired in vivo. In the horizontal plane, the angle between the surgical trans-epicondylar axis and the tibial rotational axes was assessed. RESULTS: Highest accuracy was found for posterior cruciate ligament (PCL)-anterior cruciate ligament (ACL, -1.48°, standard deviation [SD] 13.64; imageless), tibial medial condyle (TMC)-tibial lateral condyle (TLC, 1.72°, SD 4.24; image-based), the ACL-medial border of tibial tuberosity (MTT, -2.89°, SD 18.86; image-based). Highest precision was acquired with image-based technology: TMC-TLC (SD 4.24), PCL-ACL (SD 5.86), and PCL-medial third of tibial tuberosity (M3TT, SD 7.10). Excellent intraobserver and interobserver correlation coefficients were observed with image-based technology: PCL-MTT, anterior medial condyle (AMC)-anterior lateral condyle (ALC), and TMC-TLC (Intraobserver and interobserver correlation coefficients 0.90-0.98). CONCLUSION: The tibial sagittal plane could be defined with highest accuracy, precision, and repeatability on a preoperative CT. Imageless methodology lacked the precision and repeatability of image-based technology. With the current pursuit of high accuracy and precision in total knee arthroplasty, the reference frame used to quantify implant position should be highly accurate and precise as well. LEVEL OF EVIDENCE: IV, Case Series.


Asunto(s)
Ligamento Cruzado Posterior , Tibia , Humanos , Tibia/diagnóstico por imagen , Tibia/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Ligamento Cruzado Anterior/cirugía , Cadáver
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA