Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 441
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Diabetologia ; 67(10): 2199-2209, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38967668

RESUMEN

AIMS/HYPOTHESIS: The aim of this work was to investigate the association between macronutrient intakes and continuous glucose monitoring (CGM) metrics in individuals with type 1 diabetes. METHODS: In 470 individuals with type 1 diabetes of the GUTDM1 cohort (65% female, median age 40 [IQR 28-53] years, median diabetes duration 15 [IQR 6-29] years), we used logistic regression to establish associations between macronutrient intakes and the CGM metrics time in range (TIR, time spent between 3.9-10.0 mmol/l blood glucose, optimally set at ≥70%) and time below range (TBR, <3.9 mmol/l blood glucose, optimally set at <4%). ORs were expressed per 1 SD intake of nutrient and were adjusted for other macronutrient intakes, age, sex, socioeconomic status, BMI, duration of type 1 diabetes, pump use, insulin dose and alcohol intake. RESULTS: The median (IQR) TIR was 67 (51-80)% and TBR was 2 (1-4)%; the mean ± SD energy intake was 6879±2001 kJ, fat intake 75±31 g, carbohydrate intake 162±63 g, fibre intake 20±9 g and protein intake 70±24 g. A higher fibre intake and a lower carbohydrate intake were associated with higher odds of having a TIR≥70% (OR [95% CI] 1.64 [1.22, 2.24] and 0.67 [0.51, 0.87], respectively), whereas solely a higher carbohydrate intake was associated with TBR<4% (OR 1.34 [95% CI 1.02, 1.78]). CONCLUSIONS/INTERPRETATION: A higher fibre intake is independently associated with a higher TIR. A higher carbohydrate intake is associated with less time spent in hypoglycaemia, a lower TIR and a higher time above range. These findings warrant confirmatory (interventional) investigations and may impact current nutritional guidelines for type 1 diabetes.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Carbohidratos de la Dieta , Fibras de la Dieta , Humanos , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Masculino , Estudios Transversales , Adulto , Fibras de la Dieta/administración & dosificación , Glucemia/metabolismo , Glucemia/análisis , Persona de Mediana Edad , Carbohidratos de la Dieta/administración & dosificación , Ingestión de Energía , Estudios de Cohortes
2.
Diabetologia ; 67(6): 1009-1022, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38502241

RESUMEN

AIMS/HYPOTHESIS: Adults with type 1 diabetes should perform daily physical activity to help maintain health and fitness, but the influence of daily step counts on continuous glucose monitoring (CGM) metrics are unclear. This analysis used the Type 1 Diabetes Exercise Initiative (T1DEXI) dataset to investigate the effect of daily step count on CGM-based metrics. METHODS: In a 4 week free-living observational study of adults with type 1 diabetes, with available CGM and step count data, we categorised participants into three groups-below (<7000), meeting (7000-10,000) or exceeding (>10,000) the daily step count goal-to determine if step count category influenced CGM metrics, including per cent time in range (TIR: 3.9-10.0 mmol/l), time below range (TBR: <3.9 mmol/l) and time above range (TAR: >10.0 mmol/l). RESULTS: A total of 464 adults with type 1 diabetes (mean±SD age 37±14 years; HbA1c 48.8±8.1 mmol/mol [6.6±0.7%]; 73% female; 45% hybrid closed-loop system, 38% standard insulin pump, 17% multiple daily insulin injections) were included in the study. Between-participant analyses showed that individuals who exceeded the mean daily step count goal over the 4 week period had a similar TIR (75±14%) to those meeting (74±14%) or below (75±16%) the step count goal (p>0.05). In the within-participant comparisons, TIR was higher on days when the step count goal was exceeded or met (both 75±15%) than on days below the step count goal (73±16%; both p<0.001). The TBR was also higher when individuals exceeded the step count goals (3.1%±3.2%) than on days when they met or were below step count goals (difference in means -0.3% [p=0.006] and -0.4% [p=0.001], respectively). The total daily insulin dose was lower on days when step count goals were exceeded (0.52±0.18 U/kg; p<0.001) or were met (0.53±0.18 U/kg; p<0.001) than on days when step counts were below the current recommendation (0.55±0.18 U/kg). Step count had a larger effect on CGM-based metrics in participants with a baseline HbA1c ≥53 mmol/mol (≥7.0%). CONCLUSIONS/INTERPRETATION: Our results suggest that, compared with days with low step counts, days with higher step counts are associated with slight increases in both TIR and TBR, along with small reductions in total daily insulin requirements, in adults living with type 1 diabetes. DATA AVAILABILITY: The data that support the findings reported here are available on the Vivli Platform (ID: T1-DEXI; https://doi.org/10.25934/PR00008428 ).


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Ejercicio Físico , Humanos , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/terapia , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Adulto , Femenino , Masculino , Automonitorización de la Glucosa Sanguínea/métodos , Glucemia/metabolismo , Glucemia/análisis , Persona de Mediana Edad , Ejercicio Físico/fisiología , Hemoglobina Glucada/metabolismo , Hemoglobina Glucada/análisis , Insulina/uso terapéutico , Insulina/administración & dosificación , Estudios de Cohortes , Monitoreo Continuo de Glucosa
3.
Diabetologia ; 67(8): 1517-1526, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38668761

RESUMEN

AIMS/HYPOTHESIS: Previous studies have shown that individuals with similar mean glucose levels (MG) or percentage of time in range (TIR) may have different HbA1c values. The aim of this study was to further elucidate how MG and TIR are associated with HbA1c. METHODS: Data from the randomised clinical GOLD trial (n=144) and the follow-up SILVER trial (n=98) of adults with type 1 diabetes followed for 2.5 years were analysed. A total of 596 paired HbA1c/continuous glucose monitoring measurements were included. Linear mixed-effects models were used to account for intra-individual correlations in repeated-measures data. RESULTS: In the GOLD trial, the mean age of the participants (± SD) was 44±13 years, 63 (44%) were female, and the mean HbA1c (± SD) was 72±9.8 mmol/mol (8.7±0.9%). When correlating MG with HbA1c, MG explained 63% of the variation in HbA1c (r=0.79, p<0.001). The variation in HbA1c explained by MG increased to 88% (r=0.94, p value for improvement of fit <0.001) when accounting for person-to-person variation in the MG-HbA1c relationship. Time below range (TBR; <3.9 mmol/l), time above range (TAR) level 2 (>13.9 mmol/l) and glycaemic variability had little or no effect on the association. For a given MG and TIR, the HbA1c of 10% of individuals deviated by >8 mmol/mol (0.8%) from their estimated HbA1c based on the overall association between MG and TIR with HbA1c. TBR and TAR level 2 significantly influenced the association between TIR and HbA1c. At a given TIR, each 1% increase in TBR was related to a 0.6 mmol/mol lower HbA1c (95% CI 0.4, 0.9; p<0.001), and each 2% increase in TAR level 2 was related to a 0.4 mmol/mol higher HbA1c (95% CI 0.1, 0.6; p=0.003). However, neither TIR, TBR nor TAR level 2 were significantly associated with HbA1c when accounting for MG. CONCLUSIONS/INTERPRETATION: Inter-individual variations exist between MG and HbA1c, as well as between TIR and HbA1c, with clinically important deviations in relatively large groups of individuals with type 1 diabetes. These results may provide important information to both healthcare providers and individuals with diabetes in terms of prognosis and when making diabetes management decisions.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hemoglobina Glucada , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Hemoglobina Glucada/metabolismo , Femenino , Glucemia/metabolismo , Adulto , Masculino , Persona de Mediana Edad , Hipoglucemiantes/uso terapéutico , Automonitorización de la Glucosa Sanguínea
4.
Diabetologia ; 67(8): 1527-1535, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38787436

RESUMEN

AIMS/HYPOTHESIS: The aim of this study was to evaluate the association of chronic complications with time in tight range (TITR: 3.9-7.8 mmol/l) and time in range (TIR: 3.9-10.0 mmol/l) in people with type 1 diabetes. METHODS: The prevalence of microvascular complications (diabetic retinopathy, diabetic nephropathy and diabetic peripheral neuropathy [DPN]) and macrovascular complications according to sensor-measured TITR/TIR was analysed cross-sectionally in 808 adults with type 1 diabetes. Binary logistic regression was used to evaluate the association between TITR/TIR and the presence of complications without adjustment, with adjustment for HbA1c, and with adjustment for HbA1c and other confounding factors (sex, age, diabetes duration, BMI, BP, lipid profile, smoking, and use of statins and renin-angiotensin-aldosterone system inhibitors). RESULTS: The mean TITR and TIR were 33.9 ± 12.8% and 52.5 ± 15.0%, respectively. Overall, 46.0% had any microvascular complication (34.5% diabetic retinopathy, 23.8% diabetic nephropathy, 16.0% DPN) and 16.3% suffered from any macrovascular complication. The prevalence of any microvascular complication, diabetic retinopathy, diabetic nephropathy and a cerebrovascular accident (CVA) decreased with increasing TITR/TIR quartiles (all ptrend<0.05). Each 10% increase in TITR was associated with a lower incidence of any microvascular complication (OR 0.762; 95% CI 0.679, 0.855; p<0.001), diabetic retinopathy (OR 0.757; 95% CI 0.670, 0.856; p<0.001), background diabetic retinopathy (OR 0.760; 95% CI 0.655, 0.882; p<0.001), severe diabetic retinopathy (OR 0.854; 95% CI 0.731, 0.998; p=0.048), diabetic nephropathy (OR 0.799; 95% CI 0.699, 0.915; p<0.001), DPN (OR 0.837; 95% CI 0.717, 0.977; p=0.026) and CVA (OR 0.651; 95% CI 0.470, 0.902; p=0.010). The independent association of TITR with any microvascular complication (OR 0.867; 95% CI 0.762, 0.988; p=0.032), diabetic retinopathy (OR 0.837; 95% CI 0.731, 0.959; p=0.010), background diabetic retinopathy (OR 0.831; 95% CI 0.705, 0.979; p=0.027) and CVA (OR 0.619; 95% CI 0.426, 0.899; p=0.012) persisted after adjustment for HbA1c. Similar results were obtained when controlling for HbA1c and other confounding factors. CONCLUSIONS/INTERPRETATION: TITR and TIR are inversely associated with the presence of microvascular complications and CVA in people with type 1 diabetes. Although this study was not designed to establish a causal relationship, this analysis adds validity to the use of TITR and TIR as key measures in glycaemic management. TRIAL REGISTRATION: ClinicalTrials.gov NCT02601729 and NCT02898714.


Asunto(s)
Diabetes Mellitus Tipo 1 , Nefropatías Diabéticas , Neuropatías Diabéticas , Retinopatía Diabética , Humanos , Diabetes Mellitus Tipo 1/complicaciones , Masculino , Femenino , Estudios Transversales , Estudios Retrospectivos , Adulto , Persona de Mediana Edad , Retinopatía Diabética/epidemiología , Retinopatía Diabética/etiología , Nefropatías Diabéticas/epidemiología , Neuropatías Diabéticas/epidemiología , Hemoglobina Glucada/metabolismo , Prevalencia , Glucemia/metabolismo , Angiopatías Diabéticas/epidemiología
5.
Cardiovasc Diabetol ; 23(1): 322, 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39217368

RESUMEN

BACKGROUND: Continuous glucose monitoring (CGM) devices provide detailed information on daily glucose control and glycemic variability. Yet limited population-based studies have explored the association between CGM metrics and fatty liver. We aimed to investigate the associations of CGM metrics with the degree of hepatic steatosis. METHODS: This cross-sectional study included 1180 participants from the Guangzhou Nutrition and Health Study. CGM metrics, covering mean glucose level, glycemic variability, and in-range measures, were separately processed for all-day, nighttime, and daytime periods. Hepatic steatosis degree (healthy: n = 698; mild steatosis: n = 242; moderate/severe steatosis: n = 240) was determined by magnetic resonance imaging proton density fat fraction. Multivariate ordinal logistic regression models were conducted to estimate the associations between CGM metrics and steatosis degree. Machine learning models were employed to evaluate the predictive performance of CGM metrics for steatosis degree. RESULTS: Mean blood glucose, coefficient of variation (CV) of glucose, mean amplitude of glucose excursions (MAGE), and mean of daily differences (MODD) were positively associated with steatosis degree, with corresponding odds ratios (ORs) and 95% confidence intervals (CIs) of 1.35 (1.17, 1.56), 1.21 (1.06, 1.39), 1.37 (1.19, 1.57), and 1.35 (1.17, 1.56) during all-day period. Notably, lower daytime time in range (TIR) and higher nighttime TIR were associated with higher steatosis degree, with ORs (95% CIs) of 0.83 (0.73, 0.95) and 1.16 (1.00, 1.33), respectively. For moderate/severe steatosis (vs. healthy) prediction, the average area under the receiver operating characteristic curves were higher for the nighttime (0.69) and daytime (0.66) metrics than that of all-day metrics (0.63, P < 0.001 for all comparisons). The model combining both nighttime and daytime metrics achieved the highest predictive capacity (0.73), with nighttime MODD emerging as the most important predictor. CONCLUSIONS: Higher CGM-derived mean glucose and glycemic variability were linked with higher steatosis degree. CGM-derived metrics during nighttime and daytime provided distinct and complementary insights into hepatic steatosis.


Asunto(s)
Biomarcadores , Automonitorización de la Glucosa Sanguínea , Glucemia , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Humanos , Estudios Transversales , Masculino , Persona de Mediana Edad , Femenino , Glucemia/metabolismo , China/epidemiología , Anciano , Factores de Tiempo , Automonitorización de la Glucosa Sanguínea/instrumentación , Biomarcadores/sangre , Factores de Riesgo , Enfermedad del Hígado Graso no Alcohólico/sangre , Enfermedad del Hígado Graso no Alcohólico/epidemiología , Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Factores de Edad , Medición de Riesgo , Aprendizaje Automático , Hígado Graso/sangre , Hígado Graso/diagnóstico , Hígado Graso/epidemiología , Monitoreo Continuo de Glucosa , Pueblos del Este de Asia
6.
Diabetes Metab Res Rev ; 40(6): e3842, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39298688

RESUMEN

AIMS: To compare the efficacy and safety of different hybrid closed loop (HCL) systems in people with diabetes through a network meta-analysis. METHODS: We searched MEDLINE, EMBASE, CENTRAL and PubMed for randomised clinical trials (RCTs) enrolling children, adolescents and/or adults with type 1 or type 2 diabetes, evaluating Minimed 670G, Minimed 780G, Control-IQ, CamAPS Fx, DBLG-1, DBLHU, and Omnipod 5 HCL systems against other types of insulin therapy, and reporting time in target range (TIR) as outcome. RESULTS: A total of 28 RCTs, all enrolling people with type 1 diabetes, were included. HCL systems significantly increased TIR compared with subcutaneous insulin therapy without continuous glucose monitoring (SIT). Minimed 780G achieved the highest TIR ahead of Control IQ (mean difference (MD) 5.1%, 95% confidence interval (95% CI) [0.68; 9.52], low certainty), Minimed 670G (MD 7.48%, 95% CI [4.27; 10.7], moderate certainty), CamAPS Fx (MD 8.94%, 95% CI [4.35; 13.54], low certainty), and DBLG1 (MD 10.69%, 95% CI [5.73; 15.65], low certainty). All HCL systems decreased time below target range, with DBLG1 (MD -3.69%, 95% CI [-5.2; -2.19], high certainty), Minimed 670G (MD -2.9%, 95% CI [-3.77; -2.04], moderate certainty) and Minimed 780G (MD -2.79%, 95% CI [-3.94; -1.64], high certainty) exhibiting the largest reductions compared to SIT. The risk of severe hypoglycaemia and diabetic ketoacidosis was similar to other types of insulin therapy. CONCLUSIONS: We show a hierarchy of efficacy among the different HCL systems in people with type 1 diabetes, thus providing support to clinical decision-making. TRIAL REGISTRATION: PROSPERO CRD42023453717.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Metaanálisis en Red , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Insulina/administración & dosificación , Insulina/uso terapéutico , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Glucemia/análisis , Pronóstico , Ensayos Clínicos Controlados Aleatorios como Asunto , Automonitorización de la Glucosa Sanguínea/métodos
7.
Diabet Med ; : e15423, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39118381

RESUMEN

AIMS: Continuous glucose monitoring (CGM) systems are standard of care for youth with type 1 diabetes with the goal of spending >70% time in range (TIR; 70-180 mg/dL, 3.9-10 mmol/L). We aimed to understand paediatric CGM user experiences with TIR metrics considering recent discussion of shifting to time in tight range (TITR; >50% time between 70 and 140 mg/dL, 3.9 and 7.8 mmol/L). METHODS: Semi-structured interviews and focus groups with adolescents with type 1 diabetes and parents of youth with type 1 diabetes focused on experiences with TIR goals and reactions to TITR. Groups and interviews were audio-recorded, transcribed and analysed using content analysis. RESULTS: Thirty participants (N = 19 parents: age 43.6 ± 5.3 years, 79% female, 47% non-Hispanic White, 20 ± 5 months since child's diagnosis; N = 11 adolescents: age 15.3 ± 2 years, 55% female, 55% non-Hispanic White, 16 ± 3 months since diagnosis) attended. Participants had varying levels of understanding of TIR. Some developed personally preferred glucose ranges. Parents often aimed to surpass 70% TIR. Many described feelings of stress and disappointment when they did not meet a TIR goal. Concerns about TITR included increased stress and burden; risk of hypoglycaemia; and family conflict. Some participants said TITR would not change their daily lives; others said it would improve their diabetes management. Families requested care team support and a clear scientific rationale for TITR. CONCLUSIONS: The wealth of CGM data creates frequent opportunities for assessing diabetes management and carries implications for management burden. Input from people with type 1 diabetes and their families will be critical in considering a shift in glycaemic goals and targets.

8.
Diabet Med ; : e15415, 2024 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-39034472

RESUMEN

AIMS: Type 1 diabetes mellitus (T1DM) is characterised by insulin deficiency. Due to perceived physical activity (PA)-related hypoglycaemia, a minority of people with T1DM exercise regularly. However, the relationship between T1DM and PA remains poorly understood. Our aim was to summarise the existing literature on the effects of PA on short-term glucose control (glycated haemoglobin or time in range) in people with T1DM. METHODS: We searched seven electronic databases (PubMed, Embase, Cochrane library, Cinahl, SPORTDiscus, PEDro and Web Of Science) and two sources of the grey literature (ClinicalTrials.gov and ICTRP). All reviews were screened via title/abstract and full text by two independent reviewers (LE and HT), conflicts were solved by a third independent reviewer (DDC). We excluded animal studies, case reports, non-English articles, qualitative studies, conference abstracts and articles without full-text access. A meta-analysis using random effects model was performed to study the effect of PA on haemoglobin A1c (HbA1c) levels in people with T1DM. RESULTS: We obtained 19,201 unique references across nine different electronic databases. After screening and snowballing, 68 articles were found investigating the effect of PA on glycaemic control in people with T1DM. Overall, HbA1c levels in the PA group (mean difference = 0.29% (0.20%-0.39%)), were lower compared with the control group. CONCLUSION: An overall small beneficial effect of PA on glycaemic control in people with T1DM was found. Caution is advised when interpreting the results of this meta-analysis, given variations in study type, duration, frequency and intensity of physical activity across included studies.

9.
Diabet Med ; 41(8): e15333, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38671595

RESUMEN

AIMS: Time in Tight Range (TITR) is a novel glycaemic metric in monitoring type 1 diabetes (T1D) management. The aim of this study was to assess the attainability of the TITR target in children and adolescents using the advanced hybrid closed loop (AHCL). METHODS: The 2128-day CGM data from 56 children and adolescents with T1D using AHCL (Minimed-780G) were analysed. Time in Range (TIR) (3.9-10 mmol/L), TITR (3.9-7.7 mmol/L), and other glycaemic parameters were separately analysed in terms of whole day, daytime (06.00-23:59), and nighttime (00.00-05.59) results. The participants were divided into two groups by autocorrection rate where Group 1 had a rate of <30% and Group 2 had a rate of ≥30. RESULTS: All glycaemic parameters indicated a better glycaemic outcome in the nighttime with higher TIR and TITR values compared with daytime (for TIR 87.5 ± 9.5% vs. 78.8 ± 8%, p < 0.001, and TITR 68.2 ± 13.5% vs. 57.5 ± 8.8%, p < 0.001). The rates of TITR >50% and >60% were 87% and 52%, respectively. When those with TITR >60% (n: 29) and those without (n: 27) were evaluated in terms of hypoglycaemia, no statistically significant difference was found in time below range (TBR) 3-3.9 mmol/L (0.3% vs. 2.1%, p: 0.084) and TBR < 3 mmol/L (0.47% vs. 0.3%, p: 0.298). Group 1 had a significantly higher TIR and TITR compared to Group 2 (82.6 ± 6.1% vs. 75.6 ± 8.6%, p: 0.008 and 62.1 ± 7.5% vs. 53.8 ± 7.5%, p: 0.002, respectively). CONCLUSIONS: Most children and adolescents on AHCL achieved the 50% target for TITR whereas more than half achieved the >60% target. A target of >50% for TITR seems realistic in children with T1D using AHCL.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Estudios de Factibilidad , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Adolescente , Niño , Femenino , Masculino , Automonitorización de la Glucosa Sanguínea/métodos , Glucemia/metabolismo , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Insulina/uso terapéutico , Control Glucémico/métodos , Hemoglobina Glucada/metabolismo , Hemoglobina Glucada/análisis , Hipoglucemia/inducido químicamente , Factores de Tiempo
10.
Diabetes Obes Metab ; 26(2): 631-641, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37985360

RESUMEN

AIM: To investigate the safety and efficacy of track and field training compared with intensification of insulin treatment only in adolescents with type 1 diabetes (T1D). MATERIALS AND METHODS: Eighteen adolescents (seven females) with T1D were included (age 15.1 ± 1.1 years, HbA1c 7.3% ± 1.0% [56.3 ± 10.9 mmol/mol]). After a 4-week observational control phase, participants were randomized to either stand-alone intensive glycaemic management (IT; telemedicine or on-site visits, three times/week) or additionally performed track and field exercise (EX; three 60-minute sessions/week) for 4 weeks. Glycaemia was assessed via continuous glucose monitoring during observational control and intervention phases. RESULTS: Time in range (70-180 mg/dL; 3.9-10.0 mmol/L) significantly improved from the observational control phase to the exercise intervention phase in EX (69% ± 13% vs. 72% ± 11%, P = .049), but not in IT (59% ± 22% vs. 62% ± 16%, P = .399). Time below range 1 (54-69 mg/dL; < 3.9 mmol/L) improved in IT (3.1% ± 1.9% vs. 2.0% ± 0.8%, P = .017) and remained stable in EX (2.0% ± 1.7 vs. 1.9% ± 1.1%, P = .999). The EX group's HbA1c ameliorated preintervention to postintervention (mean difference: ΔHbA1c -0.19% ± 0.17%, P = .042), which was not seen within the IT group (ΔHbA1c -0.16% ± 0.37%, P = .40). Glucose standard deviation was reduced significantly in EX (55 ± 11 vs. 51 ± 10 mg/dL [3.1 ± 0.6 vs. 2.8 ± 0.6 mmol/L], P = .011), but not in IT (70 ± 24 vs. 63 ± 18 mg/dL [3.9 ± 1.3 vs. 3.5 ± 1.0 mmol/L], P = .186). CONCLUSION: Track and field training combined with intensive glycaemic management improved glycaemia in adolescents with T1D, which was not observed in the non-exercise group.


Asunto(s)
Diabetes Mellitus Tipo 1 , Atletismo , Femenino , Humanos , Adolescente , Diabetes Mellitus Tipo 1/terapia , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Hemoglobina Glucada , Automonitorización de la Glucosa Sanguínea , Glucemia
11.
Diabetes Obes Metab ; 26(2): 557-566, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37905353

RESUMEN

AIM: To investigate glycaemic outcomes in youths and adults with type 1 diabetes with either MiniMed™ 780G or Tandem t:slim X2™ control-IQ automated insulin delivery (AID) systems and to evaluate clinical factors that migrate, mitigate the achievement of therapeutic goals. MATERIALS AND METHODS: This retrospective, real-world, observational study was conducted in a specialized university type 1 diabetes centre with patients observed for 3-12 months post-initiation of an AID system. Primary outcomes were the percentage time in the target glucose range [TIR70-180 mg/dl (3.9-10 mmol/L)] as measured by continuous glucose monitoring, mean glucose management indicator (GMI) and glycated haemoglobin (HbA1c) levels. RESULTS: Our study cohort consisted of 48 adolescents and 183 adults (55% females) aged 10-77 years. The mean (95% confidence interval) TIR70-180 mg/dl after 30 days was higher than baseline and by 14% points after 360 days with 71.33% (69.4-73.2) (n = 123, p < .001). HbA1c levels decreased by 0.7% and GMI by 0.6% after 360 days. The proportion of time spent <70 mg/dl (3.9 mmol/L) was not significantly different from baseline. During follow-up, 780G users had better continuous glucose monitoring results than control-IQ users but similar HbA1c levels, and an increased risk of weight gain. Age at onset influenced TIR70-180 mg/dl in univariate analysis but there was no significant relationship after adjusting on explanatory variables. Baseline body mass index did not influence the performance of AID systems. CONCLUSIONS: This analysis showed the beneficial effects of two AID systems for people with type 1 diabetes across a broad spectrum of participant characteristics. Only half of the participants achieved international recommendations for glucose control with TIR70-180 mg/dl >70%, HbA1c levels or GMI <7%, which outlines the need to maintain strong educational and individual strategies.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Adulto , Femenino , Humanos , Adolescente , Masculino , Insulina/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Hemoglobina Glucada , Automonitorización de la Glucosa Sanguínea/métodos , Estudios Retrospectivos , Estudios de Seguimiento , Glucemia/análisis , Insulina Regular Humana/uso terapéutico , Glucosa/uso terapéutico , Sistemas de Infusión de Insulina
12.
Diabetes Obes Metab ; 26(11): 5046-5055, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39245809

RESUMEN

AIM: To evaluate the efficacy of a fixed-ratio combination of insulin glargine 100 U/mL plus lixisenatide (iGlarLixi) in people with type 2 diabetes (T2D) using derived time-in-range (dTIR). METHODS: Participant-level data from LixiLan-L, LixiLan-O and LixiLan-G were pooled and dTIR (70-180 mg/dL), derived time-above-range (> 180 mg/dL) and derived time-below-range (dTBR; < 70 mg/dL) were calculated from participant seven-point self-monitored blood glucose profiles. RESULTS: This pooled analysis included data from 2420 participants receiving iGlarLixi (n = 1093), iGlar (n = 836), Lixi (n = 234) or a glucagon-like peptide-1 receptor agonist (GLP-1 RA) (n = 257). Numerically greater improvements in least square (LS) means dTIR were seen from baseline to end of treatment (EOT) with iGlarLixi (25.7%) versus iGlar (15.8%), Lixi (11.7%) or GLP-1 RA (16.2%). At EOT, the mean (standard deviation) dTBR was 0.71% ± 3.4%, 0.61% ± 3.2%, 0.08% ± 1.0% and 0.0% ± 0.0% for iGlarLixi, iGlar, Lixi and GLP-1 RA, respectively. In a subgroup analysis, participants aged younger than 65 years (n = 1690) and 65 years or older (n = 713) showed numerically greater improvements in LS means dTIR from baseline to EOT with iGlarLixi versus iGlar, Lixi or GLP-1 RA. CONCLUSIONS: iGlarLixi achieved improvements in dTIR, with low dTBR values, providing further evidence to inform clinical outcomes with the use of iGlarLixi.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 2 , Hipoglucemiantes , Insulina Glargina , Péptidos , Humanos , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/sangre , Persona de Mediana Edad , Insulina Glargina/uso terapéutico , Femenino , Masculino , Hipoglucemiantes/uso terapéutico , Glucemia/efectos de los fármacos , Glucemia/metabolismo , Anciano , Péptidos/uso terapéutico , Péptidos/administración & dosificación , Automonitorización de la Glucosa Sanguínea , Hemoglobina Glucada/análisis , Hemoglobina Glucada/metabolismo , Hemoglobina Glucada/efectos de los fármacos , Adulto , Combinación de Medicamentos , Receptor del Péptido 1 Similar al Glucagón/agonistas , Ensayos Clínicos Controlados Aleatorios como Asunto , Receptor del Péptido 2 Similar al Glucagón
13.
Diabetes Obes Metab ; 26(11): 4916-4923, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39248215

RESUMEN

AIM: To map the glycaemic variabilities and insulin requirements across different phases of the menstrual cycle and assess the efficacy and performance of the MiniMed 780G system on mitigating glycaemic variabilities during phases of the menstrual cycle. MATERIALS AND METHODS: A pilot study recruiting 15 adolescent and young adult females with type 1 diabetes was conducted. Only females with regular spontaneous menstruation were enrolled in the current study. Phases of each menstrual cycle were determined as either follicular phase or luteal phase. The study analysed continuous glucose monitoring metrics during two study periods: the open loop period (OLP) and the advanced hybrid closed-loop (AHCL) period; each period lasted 3 consecutive months. RESULTS: During the OLP, the mean time in range (TIR) significantly decreased during the luteal phase compared with the follicular phase (65.13% ± 3.07% vs. 70.73% ± 2.05%) (P < .01). The mean time above range significantly increased from 21.07% ± 2.58% during the follicular phase to 24.87% ± 2.97% during the luteal phase (P < .01). After initiating the AHCL period, TIR was comparable during both phases of the menstrual cycle (P = .72), without increasing the time spent below 70 mg/dL (P > .05). Regarding insulin delivery during the AHCL period, the percentage of Auto basal and Auto correction delivered by the algorithm increased by 13.55% and 30.6%, respectively (P < .01), during the luteal phase. CONCLUSIONS: The fully automated adaptive algorithm of the MiniMed 780G system mitigated menstrual cycle-dependent glycaemic variability, successfully attaining the recommended glycaemic outcomes with a TIR greater than 70% throughout the entire menstrual cycle.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Sistemas de Infusión de Insulina , Insulina , Ciclo Menstrual , Humanos , Femenino , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Adolescente , Proyectos Piloto , Glucemia/metabolismo , Glucemia/análisis , Ciclo Menstrual/fisiología , Adulto Joven , Insulina/administración & dosificación , Adulto , Automonitorización de la Glucosa Sanguínea/métodos , Control Glucémico/métodos , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/administración & dosificación , Fase Folicular/fisiología , Fase Luteínica/efectos de los fármacos
14.
Diabetes Obes Metab ; 26(6): 2359-2367, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38528823

RESUMEN

AIM: To investigate the relationship of fat in the pancreas with time spent in different glycaemic ranges. METHODS: Abdominal magnetic resonance imaging at 3.0 Tesla was used to quantify fat in the pancreas as both continuous [i.e. intra-pancreatic fat deposition (IPFD)] and binary (i.e. fatty change of the pancreas vs. normal pancreas) variables. Dexcom G6 devices were used to collect continuous glucose monitoring data every 5 min over a continuous 7-day period. Time above range (TAR), time in range (TIR) and time below range were computed. Statistical models were built to adjust for age, sex, body composition, and other covariates in linear regression analysis and analysis of covariance. RESULTS: In total, 38 individuals were studied. IPFD was significantly associated with TAR (p = .036) and TIR (p = .042) after adjustment for covariates. For every 1% increase in IPFD, there was a 0.3 unit increase in TAR and a decrease in TIR. Individuals with fatty change of the pancreas, when compared with those with normal pancreas, had significantly higher TAR (p = .034) and lower TIR (p = .047) after adjustment for covariates. Neither IPFD (p = .805) nor fatty change of the pancreas (p = .555) was associated with time below range after adjustment for covariates. CONCLUSION: Increased fat in the pancreas is associated with excessive glycaemic variability. Fatty change of the pancreas may contribute to heightening the risk of cardiovascular diseases.


Asunto(s)
Monitoreo Continuo de Glucosa , Páncreas , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tejido Adiposo/diagnóstico por imagen , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Imagen por Resonancia Magnética , Páncreas/diagnóstico por imagen , Páncreas/patología
15.
Diabetes Obes Metab ; 2024 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-39344842

RESUMEN

AIMS: To conduct a meta-analysis of randomized controlled trials (RCTs) to evaluate the effect of glucagon-like peptide-1 receptor agonists (GLP-1RAs) on glycated haemoglobin (HbA1c) and continuous glucose monitoring (CGM) metrics as an adjunct to insulin therapy in adults with type 1 diabetes mellitus (T1D). METHODS: A systematic literature search was conducted through Medline (via PubMed), Cochrane Library, and Google Scholar up to 27 May 2024. Dual-independent study selection, data extraction, and quality assessment were performed. Results were summarized using random-effects meta-analysis. RESULTS: Six RCTs were identified, involving a total of 378 individuals with T1D. The use of GLP-1RAs in addition to standard insulin therapy was associated with a significant reduction in HbA1c (mean difference [MD] -0.21%, 95% confidence interval [CI] -0.36 to -0.06; p = 0.007) and a similar time in range (TIR) compared to placebo (MD -0.22%, 95% CI -2.39 to 1.95; p = 0.84). GLP-1RA therapy resulted in a significantly higher time below range (MD 1.13%, 95% CI 0.50 to 1.76; p < 0.001) and a lower time above range compared with placebo (MD -1.83%, 95% CI -2.51 to -1.15; p < 0.001). Nonsignificant differences were noted for the secondary outcomes, including the mean amplitude of glucose excursion, continuous overall net glycaemic action for 60 min, mean daily glucose, coefficient of variation, and mean standard deviation of weekly glucose levels. CONCLUSION: Our findings suggest that, in individuals with T1D, add-on therapy with GLP-1RAs does not confer significant benefits in terms of CGM metrics and is associated with a longer time below the target glycaemic range.

16.
Diabetes Obes Metab ; 26(8): 3318-3327, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38764360

RESUMEN

AIM: To examine cross-sectional associations between continuous glucose monitoring (CGM)-derived metrics and cerebral small vessel disease (SVD) in older adults with type 2 diabetes. MATERIALS AND METHODS: In total, 80 patients with type 2 diabetes aged ≥70 years were analysed. Participants underwent CGM for 14 days. From the CGM data, we derived mean sensor glucose, percentage glucose coefficient of variation, mean amplitude of glucose excursion, time in range (TIR, 70-180 mg/dl), time above range (TAR) and time below range metrics, glycaemia risk index and high/low blood glucose index. The presence of cerebral SVD, including lacunes, microbleeds, enlarged perivascular spaces and white matter hyperintensities, was assessed, and the total number of these findings comprised the total cerebral SVD score (0-4). Ordinal logistic regression analyses were performed to examine the association of CGM-derived metrics with the total SVD score. RESULTS: The median SVD score was 1 (interquartile range 0-2). Higher hyperglycaemic metrics, including mean sensor glucose, TAR >180 mg/dl, TAR >250 mg/dl, and high blood glucose index and glycaemia risk index, were associated with a higher total SVD score. In contrast, a higher TIR (per 10% increase) was associated with a lower total SVD score (odds ratio 0.73, 95% confidence interval 0.56-0.95). Glycated haemoglobin, percentage glucose coefficient of variation, mean amplitude of glucose excursions, time below range and low blood glucose index were not associated with total cerebral SVD scores. CONCLUSIONS: The hyperglycaemia metrics and TIR, derived from CGM, were associated with cerebral SVD in older adults with type 2 diabetes.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Enfermedades de los Pequeños Vasos Cerebrales , Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/complicaciones , Masculino , Femenino , Anciano , Estudios Transversales , Enfermedades de los Pequeños Vasos Cerebrales/sangre , Glucemia/análisis , Glucemia/metabolismo , Anciano de 80 o más Años , Angiopatías Diabéticas/sangre , Angiopatías Diabéticas/epidemiología , Angiopatías Diabéticas/diagnóstico , Angiopatías Diabéticas/etiología , Hiperglucemia/sangre , Monitoreo Continuo de Glucosa
17.
Intern Med J ; 54(1): 121-128, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37255209

RESUMEN

BACKGROUND AND AIMS: Automated insulin delivery (AID) improves glycaemia among people with type 1 diabetes in clinical trials and overseas real-world studies. Whether improvements are sustained beyond 12 months in the real world, and whether they occur in the Australian context, has not yet been established. We aimed to observe, up to 2 years, the effectiveness of initiating first-generation AID for type 1 diabetes management. METHODS: Retrospective, real-world, observational study using medical records, conducted across five sites in Australia. Adults with type 1 diabetes, who had AID initiated between February 2019 and December 2021, were observed for 6-24 months after initiation (until June 2022). Outcomes examined included glucose metrics assessed by glycated haemoglobin (HbA1c ) and continuous glucose monitoring (CGM), safety and therapy continuation. RESULTS: Ninety-four adults were studied (median age 39 years (interquartile range, IQR: 31-51); pre-initiation HbA1c 7.8% (7.2-8.6)). After AID initiation, HbA1c decreased by mean 0.5 percentage points (95% confidence interval (CI): -0.7 to -0.2) at 3 months (P < 0.001); CGM time in range 3.9-10.0 mmol/L increased by 11 percentage points (9-14) at 1 month (P < 0.001); these improvements were maintained up to 24 months (all P < 0.02). Median CGM time below 3.9 mmol/L was <1.5% pre- and post-AID initiation. The subgroup with pre-initiation HbA1c above 8.5% had the greatest HbA1c improvement (-1.4 percentage points (-1.8 to -1.1) at 3 months). Twelve individuals (13%) discontinued AID, predominantly citing difficulties with CGM. During the 150 person-years observed, four diabetes-related emergencies were documented: three severe hypoglycaemic events and one hyperglycaemic event without ketoacidosis. CONCLUSIONS: Early glucose improvements were observed after real-world AID initiation, sustained up to 2 years, without excess adverse events. The greatest benefits were observed among individuals with highest glycaemia before initiation. Future-generation systems with increased user-friendliness may enhance therapy continuation.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Diabetes Mellitus Tipo 1/inducido químicamente , Insulina , Glucemia , Automonitorización de la Glucosa Sanguínea , Estudios Retrospectivos , Australia/epidemiología , Hipoglucemiantes , Sistemas de Infusión de Insulina
18.
BMC Nephrol ; 25(1): 117, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38553732

RESUMEN

BACKGROUND: Relationship between serum phosphorus time in range and mortality risk in peritoneal dialysis (PD) patients remains uncertain. We aimed to evaluate the association between serum phosphorus time in range and all-cause mortality in Chinese PD population. METHODS: This was a multicenter, retrospective, cohort study of 1,915 patients collected from January 2008 to October 2020 in 4 Chinese centers. Serum phosphorus time in range was estimated as the months during the first year that a patient's serum phosphorus level was within the target range (defined as 1.13-1.78 mmol/L). The primary outcome was all-cause mortality. The secondary outcomes were cardiovascular (CV) mortality and PD withdrawal. Cox proportional hazards regression model with comprehensive adjustments was used to assess the association. RESULTS: The primary outcome occurred in 249 (13.0%) PD patients over a median follow-up of 28 months. Overall, the serum phosphorus time in range was negatively associated with all-cause mortality (per 3-month increments, adjusted HR [aHR], 0.83; 95%CI: 0.75-0.92), CV mortality (per 3-month increments, aHR, 0.87; 95%CI: 0.77-0.99), and PD withdrawal (per 3-month increments, aHR, 0.89; 95%CI: 0.83-0.95). Competing-risk model showed that the relationship of serum phosphorus time in range with all-cause mortality remained stable. None of the variables including demographics, history of diabetes and CV disease, as well as several PD-related and clinical indicators modified this association. CONCLUSIONS: PD patients with longer serum phosphorus time in range in the first year was negatively associated with all-cause mortality and CV mortality. Our findings highlight the importance of maintaining serum phosphorus levels within 1.13-1.78 mmol/L for PD patients.


Asunto(s)
Enfermedades Cardiovasculares , Diálisis Peritoneal , Humanos , Estudios de Cohortes , Estudios Retrospectivos , Fósforo , Diálisis Peritoneal/efectos adversos , Modelos de Riesgos Proporcionales
19.
Med Princ Pract ; : 1-9, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39134001

RESUMEN

INTRODUCTION: Imeglimin is a novel antidiabetic drug with insulinotropic and insulin-sensitizing effects that targets mitochondrial bioenergetics. We investigated acute effects of add-on therapy with imeglimin to preceding metformin on the 24-h glucose profile and glycemic variability assessed by continuous glucose monitoring (CGM) in patients with type 2 diabetes. METHODS: We studied 30 outpatients with type 2 diabetes inadequately controlled with metformin. CGM was used for 14 days straight during the research period. Imeglimin 2,000 mg/day was started on day 7 after initiating CGM. Several CGM parameters were compared between days 4-6 (prior to imeglimin treatment) and 11-13 (following the initiation of imeglimin treatment). RESULTS: After treatment with imeglimin, 24-h mean glucose was acutely decreased from 161.6 ± 48.0 mg/dL to 138.9 ± 32.2 mg/dL (p < 0.0001), while time in range (i.e., at a glucose level of 70-180 mg/dL) was significantly increased from 69.9 ± 23.9% to 80.6 ± 21.0% (p < 0.0001). Addition of imeglimin to metformin significantly decreased the standard deviation (SD) of 24-h glucose and mean amplitude of glycemic excursions, 2 indexes of glycemic variability. Baseline serum high-density lipoprotein (HDL) cholesterol was negatively correlated with changes in mean 24-h glucose (r = -0.3859, p = 0.0352) and those in SD (r = -0.4015, p = 0.0309). CONCLUSIONS: Imeglimin add-on therapy to metformin acutely lowered 24-h glucose levels and improved glycemic variability in patients with type 2 diabetes on metformin. A higher serum HDL cholesterol at baseline was associated with a better response to acute effects of imeglimin on 24-h glucose levels and glycemic variability.

20.
Diabetes Metab Res Rev ; 39(6): e3639, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36964957

RESUMEN

AIMS: Diabetic retinopathy (DR) can occur even in well-controlled type 2 diabetes, suggesting residual risks of DR in this population. In particular, we investigated the combined effect of thyroid function and glycaemic control assessed by an emerging metric, time in range (TIR) with DR. MATERIALS AND METHODS: In this cross-sectional study, a total of 2740 euthyroid patients with type 2 diabetes were included. Thyroid indicators, including thyroid-stimulating hormone (TSH), free triiodothyronine, free thyroxine, thyroid peroxidase antibody and thyroglobulin antibody, were measured. TIR was measured using continuous glucose monitoring data. RESULTS: Overall, the multivariable-adjusted odds ratios (ORs) for DR across ascending tertiles of TSH were 1.00 (reference), 1.06 (95% confidence interval [CI] 0.85-1.32), and 1.48 (95% CI 1.19-1.85). Even in well-controlled participants who achieved a TIR target of >70% (n = 1449), the prevalence of DR was 23.8%, which was significantly related to TSH (OR = 1.54, 95% CI 1.12-2.12, highest vs. lowest TSH tertile). Participants were then classified into 6 groups by the joint categories of TIR (>70%, ≤70%) and TSH (tertiles), and the multivariable-adjusted ORs for DR were highest in TIR ≤70% and the highest TSH tertile group (OR = 1.96, 95% CI 1.41-2.71) when compared with the TIR >70% and the lowest TSH tertile group. CONCLUSIONS: In type 2 diabetic patients with well-controlled glycaemic status, higher TSH within the normal range was associated with an increased risk of DR. The combination of suboptimal TSH and TIR further increased the risk of DR.


Asunto(s)
Diabetes Mellitus Tipo 2 , Retinopatía Diabética , Humanos , Tirotropina , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/epidemiología , Pruebas de Función de la Tiroides , Retinopatía Diabética/epidemiología , Retinopatía Diabética/etiología , Estudios Transversales , Automonitorización de la Glucosa Sanguínea , Glucemia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA