1.
Respir Res ; 25(1): 361, 2024 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-39369209

RESUMEN

BACKGROUND AND AIMS: Because bronchoscopy is an invasive procedure, sedatives and analgesics are commonly administered, which may suppress the patient's spontaneous breathing and can lead to hypoventilation and hypoxemia. Few reports exist on the dynamic monitoring of oxygenation and ventilation during bronchoscopy. This study aimed to prospectively monitor and evaluate oxygenation and ventilation during bronchoscopy using transcutaneous arterial blood oxygen saturation and carbon dioxide. METHODS: We included patients who required pathological diagnosis using fluoroscopic bronchoscopy at our hospital between March 2021 and April 2022. Midazolam was intravenously administered to all patients as a sedative during bronchoscopy, and fentanyl was administered in addition to midazolam when necessary. A transcutaneous blood gas monitor was used to measure dynamic changes, including arterial blood partial pressure of carbon dioxide (tcPCO2), transcutaneous arterial blood oxygen saturation (SpO2), pulse rate, and perfusion index during bronchoscopy. Quantitative data of tcPCO2 and SpO2 were presented as mean ± standard deviation (SD) (min-max), while the quantitative data of midazolam plus fentanyl and midazolam alone were compared. Similarly, data on sex, smoking history, and body mass index were compared. Subgroup comparisons of the difference (Δ value) between baseline tcPCO2 at the beginning of bronchoscopy and the maximum value of tcPCO2 during the examination were performed. RESULTS: Of the 117 included cases, consecutive measurements were performed in 113 cases, with a success rate of 96.6%. Transbronchial lung biopsy was performed in 100 cases, whereas transbronchial lung cryobiopsy was performed in 17 cases. Midazolam and fentanyl were used as anesthetics during bronchoscopy in 46 cases, whereas midazolam alone was used in 67 cases. The median Δ value in the midazolam plus fentanyl and midazolam alone groups was 8.10 and 4.00 mmHg, respectively, indicating a significant difference of p < 0.005. The mean ± standard deviation of tcPCO2 in the midazolam plus fentanyl and midazolam alone groups was 44.8 ± 7.83 and 40.6 ± 4.10 mmHg, respectively. The SpO2 in the midazolam plus fentanyl and midazolam alone groups was 94.4 ± 3.37 and 96.2 ± 2.61%, respectively, with a larger SD and greater variability in the midazolam plus fentanyl group. CONCLUSION: A transcutaneous blood gas monitor is non-invasive and can easily measure the dynamic transition of CO2. Furthermore, tcPCO2 can be used to evaluate the ventilatory status during bronchoscopy easily. A transcutaneous blood gas monitor may be useful to observe regarding respiratory depression during bronchoscopy, particularly when analgesics are used.


Asunto(s)
Monitoreo de Gas Sanguíneo Transcutáneo , Broncoscopía , Dióxido de Carbono , Saturación de Oxígeno , Humanos , Broncoscopía/métodos , Masculino , Femenino , Estudios Prospectivos , Persona de Mediana Edad , Monitoreo de Gas Sanguíneo Transcutáneo/métodos , Dióxido de Carbono/sangre , Anciano , Saturación de Oxígeno/fisiología , Midazolam/administración & dosificación , Oxígeno/sangre , Fentanilo/administración & dosificación , Adulto , Hipnóticos y Sedantes/administración & dosificación
2.
Blood Purif ; 52(2): 103-113, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36037805

RESUMEN

BACKGROUND: Extracorporeal carbon dioxide removal (ECCO2R) was used to prevent invasive mechanical ventilation and associated mechanical damage in patients with acute respiratory distress syndrome (ARDS). OBJECTIVES: This study aimed to investigate the efficacy and safety of ECCO2R treatment in patients with ARDS or chronic obstructive pulmonary disease (COPD). METHODS: MEDLINE, EMBASE, and the Cochrane Library were systematically searched for relevant studies that reported patient prognosis, blood gas parameters, and ECCO2R-related adverse events (AEs) published as of September 2020. Odds ratios (ORs), weighted mean differences (WMDs), and their corresponding 95% confidence intervals (CIs) were used to compare the outcomes. RESULTS: Fifteen studies involving 532 ARDS or COPD patients were included. Compared with controls, ECCO2R did not influence the 28-day mortality (OR = 0.73, 95% CI: 0.28-1.87, p = 0.51), the length of hospital stay (WMD = 3.34, 95% CI: -5.22 to 11.90, p = 0.444), and the length of intensive care unit stay (WMD = -0.39, 95% CI: -8.76 to 7.99, p = 0.928). Compared with baseline values, partial pressure of carbon dioxide (PaCO2) in the ECCO2R group was significantly reduced, while the ratio of arterial oxygen partial pressure to fractional inspired oxygen (PaO2/FiO2) and pH increased. The overall rate of ECCO2R-related AEs was 35% (95% CI: 17-53%, p < 0.001), and bleeding was the most common AE with a rate of 22% (95% CI: 13-31%, p = 0.002). The rate of ECCO2R-related deaths was low. CONCLUSIONS: In conclusion, there was no statistically significant difference in the prognosis of patients with and without ECCO2R treatment. ECCO2R significantly reduced PaCO2 and improved PaO2/FiO2 and pH values in patients with ARDS or COPD. Bleeding was the most common ECCO2R-related AE.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Síndrome de Dificultad Respiratoria , Humanos , Dióxido de Carbono , Respiración Artificial/efectos adversos , Síndrome de Dificultad Respiratoria/etiología , Enfermedad Pulmonar Obstructiva Crónica/etiología , Enfermedad Pulmonar Obstructiva Crónica/terapia , Oxígeno
3.
BMC Pediatr ; 23(1): 20, 2023 01 14.
Artículo en Inglés | MEDLINE | ID: mdl-36639787

RESUMEN

PURPOSE: The present study aimed to investigate the correlation between transcutaneous carbon dioxide partial pressure (PtcCO2) and arterial carbon dioxide pressure (PaCO2) and the accuracy of PtcCO2 in predicting PaCO2 during laparoscopic surgery in pediatric patients. METHODS: Children aged 2-8 years with American Society of Anesthesiologists (ASA) class I or II who underwent laparoscopic surgery under general anesthesia were selected. After anesthesia induction and tracheal intubation, PtcCO2 was monitored, and radial arterial catheterization was performed for continuous pressure measurement. PaCO2, PtcCO2, and end-tidal carbon dioxide partial pressure (PetCO2) were measured before pneumoperitoneum, and 30, 60, and 90 min after pneumoperitoneum, respectively. The correlation and agreement between PtcCO2 and PaCO2, PetCO2, and PaCO2 were evaluated. RESULTS: A total of 32 patients were eventually enrolled in this study, resulting in 128 datasets. The linear regression equations were: PtcCO2 = 7.89 + 0.82 × PaCO2 (r2 = 0.70, P < 0.01); PetCO2 = 9.87 + 0.64 × PaCO2 (r2 = 0.69, P < 0.01). The 95% limits of agreement (LOA) of PtcCO2 - PaCO2 average was 0.66 ± 4.92 mmHg, and the 95% LOA of PetCO2 - PaCO2 average was -4.4 ± 4.86 mmHg. A difference of ≤ 5 mmHg was noted between PtcCO2 and PaCO2 in 122/128 samples and between PetCO2 and PaCO2 in 81/128 samples (P < 0.01). CONCLUSION: In pediatric laparoscopic surgery, a close correlation was established between PtcCO2 and PaCO2. Compared to PetCO2, PtcCO2 can estimate PaCO2 accurately and could be used as an auxiliary monitoring indicator to optimize anesthesia management for laparoscopic surgery in children; however, it is not a substitute for PetCO2. REGISTRATION NUMBER OF CHINESE CLINICAL TRIAL REGISTRY: ChiCTR2100043636.


Asunto(s)
Laparoscopía , Neumoperitoneo , Humanos , Niño , Dióxido de Carbono , Monitoreo de Gas Sanguíneo Transcutáneo/métodos , Monitoreo Fisiológico
4.
Medicina (Kaunas) ; 59(7)2023 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-37512072

RESUMEN

According to Fick's principle, the total uptake of (or release of) a substance by tissues is the product of blood flow and the difference between the arterial and the venous concentration of the substance. Therefore, the mixed or central venous minus arterial CO2 content difference depends on cardiac output (CO). Assuming a linear relationship between CO2 content and partial pressure, central or mixed venous minus arterial PCO2 differences (Pcv-aCO2 and Pmv-aCO2) are directly related to CO. Nevertheless, this relationship is affected by alterations in the CO2Hb dissociation curve induced by metabolic acidosis, hemodilution, the Haldane effect, and changes in CO2 production (VCO2). In addition, Pcv-aCO2 and Pmv-aCO2 are not interchangeable. Despite these confounders, CO is a main determinant of Pcv-aCO2. Since in a study performed in septic shock patients, Pmv-aCO2 was correlated with changes in sublingual microcirculation but not with those in CO, it has been proposed as a monitor for microcirculation. The respiratory quotient (RQ)-RQ = VCO2/O2 consumption-sharply increases in anaerobic situations induced by exercise or critical reductions in O2 transport. This results from anaerobic VCO2 secondary to bicarbonate buffering of anaerobically generated protons. The measurement of RQ requires expired gas analysis by a metabolic cart, which is not usually available. Thus, some studies have suggested that the ratio of Pcv-aCO2 to arterial minus central venous O2 content (Pcv-aCO2/Ca-cvO2) might be a surrogate for RQ and tissue oxygenation. In this review, we analyze the physiologic determinants of Pcv-aCO2 and Pcv-aCO2/Ca-cvO2 and their potential usefulness and limitations for the monitoring of critically ill patients. We discuss compelling evidence showing that they are misleading surrogates for tissue perfusion and oxygenation, mainly because they are systemic variables that fail to track regional changes. In addition, they are strongly dependent on changes in the CO2Hb dissociation curve, regardless of changes in systemic and microvascular perfusion and oxygenation.


Asunto(s)
Dióxido de Carbono , Choque Séptico , Humanos , Análisis de los Gases de la Sangre , Hemodinámica , Gasto Cardíaco
5.
J Transl Med ; 19(1): 390, 2021 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-34774068

RESUMEN

BACKGROUND: Despite much evidence supporting the monitoring of the divergence of transcutaneous partial pressure of carbon dioxide (tcPCO2) from arterial partial pressure carbon dioxide (artPCO2) as an indicator of the shock status, data are limited on the relationships of the gradient between tcPCO2 and artPCO2 (tc-artPCO2) with the systemic oxygen metabolism and hemodynamic parameters. Our study aimed to test the hypothesis that tc-artPCO2 can detect inadequate tissue perfusion during hemorrhagic shock and resuscitation. METHODS: This prospective animal study was performed using female pigs at a university-based experimental laboratory. Progressive massive hemorrhagic shock was induced in mechanically ventilated pigs by stepwise blood withdrawal. All animals were then resuscitated by transfusing the stored blood in stages. A transcutaneous monitor was attached to their ears to measure tcPCO2. A pulmonary artery catheter (PAC) and pulse index continuous cardiac output (PiCCO) were used to monitor cardiac output (CO) and several hemodynamic parameters. The relationships of tc-artPCO2 with the study parameters and systemic oxygen delivery (DO2) were analyzed. RESULTS: Hemorrhage and blood transfusion precisely impacted hemodynamic and laboratory data as expected. The tc-artPCO2 level markedly increased as CO decreased. There were significant correlations of tc-artPCO2 with DO2 and COs (DO2: r = - 0.83, CO by PAC: r = - 0.79; CO by PiCCO: r = - 0.74; all P < 0.0001). The critical level of oxygen delivery (DO2crit) was 11.72 mL/kg/min according to transcutaneous partial pressure of oxygen (threshold of 30 mmHg). Receiver operating characteristic curve analyses revealed that the value of tc-artPCO2 for discrimination of DO2crit was highest with an area under the curve (AUC) of 0.94, followed by shock index (AUC = 0.78; P < 0.04 vs tc-artPCO2), and lactate (AUC = 0.65; P < 0.001 vs tc-artPCO2). CONCLUSIONS: Our observations suggest the less-invasive tc-artPCO2 monitoring can sensitively detect inadequate systemic oxygen supply during hemorrhagic shock. Further evaluations are required in different forms of shock in other large animal models and in humans to assess its usefulness, safety, and ability to predict outcomes in critical illnesses.


Asunto(s)
Choque Hemorrágico , Animales , Dióxido de Carbono , Femenino , Oxígeno , Presión Parcial , Perfusión , Estudios Prospectivos , Resucitación , Choque Hemorrágico/terapia , Porcinos
6.
J Cardiothorac Vasc Anesth ; 35(12): 3604-3611, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34088551

RESUMEN

OBJECTIVE: The objective of this study was to assess whether the central venous-to-arterial carbon dioxide partial-pressure difference (ΔPCO2) and the ratio of the ΔPCO2 to the arterial-venous difference in oxygen content (ΔPCO2/Ca-vO2) predict postoperative complications (PC) after cardiac surgery. DESIGN: Prospective, observational, noninterventional study. PARTICIPANTS: The study comprised 60 patients undergoing cardiac surgery with cardiopulmonary bypass. INTERVENTIONS: The primary endpoint was the occurrence of PC. Data were first analyzed in two groups based on the occurrence of PC. Then, receiver operating characteristic curves of the ΔPCO2 and the ΔPCO2/Ca-vO2 ratio were analyzed for the prediction of PC. MEASUREMENTS AND MAIN RESULTS: Among the study participants, 22 (36.7%) experienced PC. The death rate was 18.3%. The present study found that the ΔPCO2 and the ΔPCO2/Ca-vO2 ratio predicted the occurrence of PC with areas under the curve of 0.702 and 0.666, respectively. The best thresholds of these markers were 8.3 mmHg for the ΔPCO2 and 2.16 mmHg/mL for the ΔPCO2/Ca-vO2 ratio. A significant difference was found for these indicators between the groups with and without PC. The ΔPCO2 and the ΔPCO2/Ca-vO2 ratio were significantly correlated to EuroSCORE II, duration of aortic clamping, majority of prognostic scores the first two days postoperatively, and the lactate level. The ΔPCO2/Ca-vO2 ratio is predictive of hyperlactatemia >2 mmol/L, with an area under the curve of 0.787. CONCLUSION: The ΔPCO2 and the ΔPCO2/Ca-vO2 ratio predict the occurrence of complications in cardiac surgery.


Asunto(s)
Dióxido de Carbono , Procedimientos Quirúrgicos Cardíacos , Análisis de los Gases de la Sangre , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Puente Cardiopulmonar/efectos adversos , Humanos , Oxígeno , Estudios Prospectivos
7.
Pediatr Cardiol ; 42(7): 1601-1606, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34106319

RESUMEN

BACKGROUND: Elevated arterial-central venous carbon dioxide partial pressure difference (AVCO2) may be an important marker to predict tissue and organ hypoperfusion in adults. We analyzed the hemodynamic data of infants with congenital heart disease who underwent corrective repair with cardiopulmonary bypass (CPB) to identify whether AVCO2 has clinical significance in early postoperative tissue hypoperfusion, occurrence of complications, and clinical outcomes. METHODS: Infants with clinical conditions of hypoperfusion, without volume responsiveness and with ineffective initial treatment, within 3 h of cardiac surgery were enrolled in this study. A pulse contour cardiac output catheter was used to monitor the cardiac index (CI). Eight measurements of arterial blood gas and central venous blood gas were taken within 42 h after surgery. Clinical data of all patients were recorded. RESULTS: A total of 69 children were enrolled in this study. Arteriovenous oxygen difference, AVCO2, lactic acid level, and vasoactive inotropic score in the hypoperfusion group (oxygen supply/oxygen consumption ratio [DO2/VO2] of ≤ 2) were significantly higher than those in the non-hypoperfusion group (DO2/VO2 > 2), while the CI in the hypoperfusion group was significantly lower than that in the non-hypoperfusion group. The cutoff value of AVCO2 to predict DO2/VO2 ≤ 2 was 12.3 within 42 h of surgery with area under the curve of 0.84. High AVCO2 is more likely to be associated with some complications and prolonged mechanical ventilation and length of stay in the intensive care unit. CONCLUSION: Elevated AVCO2 within 42 h of CPB in infants is associated with tissue and organ hypoperfusion and incidence of complications. Persistent or repeated increase in AVCO2 indicates poor prognosis.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiopatías Congénitas , Adulto , Dióxido de Carbono , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Niño , Cardiopatías Congénitas/cirugía , Humanos , Lactante , Oxígeno , Presión Parcial , Periodo Posoperatorio , Pronóstico
8.
COPD ; 18(1): 16-25, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33455452

RESUMEN

Gas exchange inefficiency and dynamic hyperinflation contributes to exercise limitation in chronic obstructive pulmonary disease (COPD). It is also characterized by an elevated fraction of physiological dead space (VD/VT). Noninvasive methods for accurate VD/VT assessment during exercise in patients are lacking. The current study sought to compare transcutaneous PCO2 (TcPCO2) with the gold standard-arterial PCO2 (PaCO2)-and other available methods (end tidal CO2 and the Jones equation) for estimating VD/VT during incremental exercise in COPD. Ten COPD patients completed a symptom limited incremental cycle exercise. TcPCO2 was measured by a heated electrode on the ear-lobe. Radial artery blood was collected at rest, during unloaded cycling (UL) and every minute during exercise and recovery. Ventilation and gas exchange were measured breath-by-breath. Bland-Altman analysis examined agreement of PCO2 and VD/VT calculated using PaCO2, TcPCO2, end-tidal PCO2 (PETCO2) and estimated PaCO2 by the Jones equation (PaCO2-Jones). Lin's Concordance Correlation Coefficient (CCC) was assessed. 114 measurements were obtained from the 10 COPD subjects. The bias between TcPCO2 and PaCO2 was 0.86 mmHg with upper and lower limit of agreement ranging -2.28 mmHg to 3.99 mmHg. Correlation between TcPCO2 and PaCO2 during rest and exercise was r2=0.907 (p < 0.001; CCC = 0.941) and VD/VT using TcPCO2 vs. PaCO2 was r2=0.958 (p < 0.0001; CCC = 0.967). Correlation between PaCO2-Jones and PETCO2 vs. PaCO2 were r2=0.755, 0.755, (p < 0.001; CCC = 0.832, 0.718) and for VD/VT calculation (r2=0.793, 0.610; p < 0.0001; CCC = 0.760, 0.448), respectively. The results support the accuracy of TcPCO2 to reflect PaCO2 and calculate VD/VT during rest and exercise, but not in recovery, in COPD patients, enabling improved accuracy of noninvasive assessment of gas exchange inefficiency during incremental exercise testing.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Dióxido de Carbono , Ejercicio Físico , Prueba de Esfuerzo , Humanos , Intercambio Gaseoso Pulmonar , Volumen de Ventilación Pulmonar
9.
Zhongguo Dang Dai Er Ke Za Zhi ; 23(8): 809-813, 2021 Aug 15.
Artículo en Inglés, Zh | MEDLINE | ID: mdl-34511170

RESUMEN

OBJECTIVES: To evaluate the accuracy and safety of measurements of transcutaneous carbon dioxide partial pressure (TcPCO2) and transcutaneous oxygen partial pressure (TcPO2) at electrode temperatures lower than the value used in clinical practice in very low birth weight infants. METHODS: A total of 45 very low birth weight infants were enrolled. TcPCO2 and TcPO2 measurements were performed in these infants. Two transcutaneous monitors were placed simultaneously for each subject. One electrode was set and maintained at 42℃ used in clinical practice for neonates (control group), and the other was successively set at 38℃, 39℃, 40°C, and 41℃ (experimental group). The paired t-test was used to compare the measurement results between the groups. A Pearson correlation analysis was used to analyze the correlation between the measurement results of the experimental group and control group, and between the measurement results of experimental group and arterial blood gas parameters. RESULTS: There was no significant difference in TcPCO2 between each experimental subgroup (38-41℃) and the control group. TcPCO2 in each experimental subgroup (38-41℃) was strongly positively correlated with TcPCO2 in the control group (r>0.9, P<0.05) and arterial carbon dioxide partial pressure (r>0.8, P<0.05). There were significant differences in TcPO2 between each experimental subgroup (38-41℃) and the control group (P<0.05), but TcPO2 in each experimental subgroup (38-41℃) was positively correlated with TcPO2 in the control group (r=0.493-0.574, P<0.05) and arterial oxygen partial pressure (r=0.324-0.399, P<0.05). No skin injury occurred during transcutaneous measurements at all electrode temperatures. CONCLUSIONS: Lower electrode temperatures (38-41℃) can accurately measure blood carbon dioxide partial pressure in very low birth weight infants, and thus can be used to replace the electrode temperature of 42°C. Transcutaneous measurements at the lower electrode temperatures may be helpful for understanding the changing trend of blood oxygen partial pressure.


Asunto(s)
Monitoreo de Gas Sanguíneo Transcutáneo , Dióxido de Carbono , Electrodos , Humanos , Lactante , Recién Nacido , Recién Nacido de muy Bajo Peso , Oxígeno , Presión Parcial , Temperatura
11.
Crit Care ; 22(1): 196, 2018 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-30119692

RESUMEN

BACKGROUND: Dyscarbia is common in out-of-hospital cardiac arrest (OHCA) patients and its association to neurological outcome is undetermined. METHODS: This is an exploratory post-hoc substudy of the Target Temperature Management (TTM) trial, including resuscitated OHCA patients, investigating the association between serial measurements of arterial partial carbon dioxide pressure (PaCO2) and neurological outcome at 6 months, defined by the Cerebral Performance Category (CPC) scale, dichotomized to good outcome (CPC 1 and 2) and poor outcome (CPC 3-5). The effects of hypercapnia and hypocapnia, and the time-weighted mean PaCO2 and absolute PaCO2 difference were analyzed. Additionally, the association between mild hypercapnia (6.0-7.30 kPa) and neurological outcome, its interaction with target temperature (33 °C and 36 °C), and the association between PaCO2 and peak serum-Tau were evaluated. RESULTS: Of the 939 patients in the TTM trial, 869 were eligible for analysis. Ninety-six percent of patients were exposed to hypocapnia or hypercapnia. None of the analyses indicated a statistical significant association between PaCO2 and neurological outcome (P = 0.13-0.96). Mild hypercapnia was not associated with neurological outcome (P = 0.78) and there was no statistically significant interaction with target temperature (Pinteraction = 0.95). There was no association between PaCO2 and peak serum-Tau levels 48 or 72 h after return of spontaneous circulation (ROSC). CONCLUSIONS: Dyscarbia is common after ROSC. No statistically significant association between PaCO2 in the post-cardiac arrest phase and neurological outcome at 6 months after cardiac arrest was detected. There was no significant interaction between mild hypercapnia and temperature in relation to neurological outcome.


Asunto(s)
Dióxido de Carbono/análisis , Evaluación del Resultado de la Atención al Paciente , Anciano , Análisis de los Gases de la Sangre/métodos , Dióxido de Carbono/efectos adversos , Dióxido de Carbono/sangre , Femenino , Humanos , Hipercapnia/complicaciones , Hipocapnia/complicaciones , Hipotermia Inducida/métodos , Hipotermia Inducida/normas , Modelos Logísticos , Masculino , Persona de Mediana Edad , Paro Cardíaco Extrahospitalario/complicaciones , Paro Cardíaco Extrahospitalario/fisiopatología , Fenómenos Fisiológicos Respiratorios
12.
Am J Respir Crit Care Med ; 196(8): 964-984, 2017 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-28406724

RESUMEN

Acute respiratory distress syndrome (ARDS) is characterized by severe impairment of gas exchange. Hypoxemia is mainly due to intrapulmonary shunt, whereas increased alveolar dead space explains the alteration of CO2 clearance. Assessment of the severity of gas exchange impairment is a requisite for the characterization of the syndrome and the evaluation of its severity. Confounding factors linked to hemodynamic status can greatly influence the relationship between the severity of lung injury and the degree of hypoxemia and/or the effects of ventilator settings on gas exchange. Apart from situations of rescue treatment, targeting optimal gas exchange in ARDS has become less of a priority compared with prevention of injury. A complex question for clinicians is to understand when improvement in oxygenation and alveolar ventilation is related to a lower degree or risk of injury for the lungs. In this regard, a full understanding of gas exchange mechanism in ARDS is imperative for individualized symptomatic support of patients with ARDS.


Asunto(s)
Investigación Biomédica/historia , Intercambio Gaseoso Pulmonar/fisiología , Respiración Artificial/métodos , Síndrome de Dificultad Respiratoria/historia , Síndrome de Dificultad Respiratoria/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Historia del Siglo XX , Historia del Siglo XXI , Humanos , Masculino , Persona de Mediana Edad , Síndrome de Dificultad Respiratoria/diagnóstico , Síndrome de Dificultad Respiratoria/terapia , Estados Unidos
14.
Indian J Crit Care Med ; 18(11): 711-5, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25425837

RESUMEN

BACKGROUND AND AIM: Arterial carbon dioxide tension (PaCO2) is considered the gold standard for scrupulous monitoring in pediatric intensive care unit (PICU), but it is invasive, laborious, expensive, and intermittent. The study aims to explore when we can use end-tidal carbon dioxide tension (PETCO2) as a reliable, continuous, and noninvasive monitor of arterial CO2. MATERIALS AND METHODS: Concurrent PETCO2, fraction of inspired oxygen, PaCO2, and arterial oxygen tension values of clinically stable children on mechanical ventilation were recorded. Children with extra-pulmonary ventriculoatrial shunts were excluded. The PETCO2 and PaCO2 difference and its variability and reproducibility were studied. RESULTS: A total of 624 concurrent readings were obtained from 105 children (mean age [SD] 5.53 [5.43] years) requiring invasive bi-level positive airway pressure ventilation in the PICU. All had continuous PETCO2 monitoring and an arterial line for blood gas measurement. The mean (SD) number of concurrent readings obtained from each child, 4-6 h apart was 6.0 (4.05). The PETCO2 values were higher than PaCO2 in 142 observations (22.7%). The PaCO2-PETCO2 difference was individual admission specific (ANOVA, P < 0.001). The PaCO2-PETCO2 difference correlated positively with the alveolar-arterial oxygen tension [P(A-a)O2] difference (ρ = 0.381 P < 0.0001). There was a fixed bias between the PETCO2 and PaCO2 measuring methods, difference +0.66 KPa (95% confidence interval: +0.57 to +0.76). CONCLUSIONS: The PaCO2-PETCO2 difference was individual specific. It was not affected by the primary disorder leading to the ventilation.

15.
Mar Environ Res ; 201: 106699, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39178709

RESUMEN

To investigate air-sea CO2 flux at the Qingdao nearshore site and its temporal variations, a high-resolution continuous observation of surface carbon dioxide partial pressure (pCO2) was carried out at Zhongyuan Pier near Tuandao from May 25 to July 8, 2019. It was observed that during this period, surface pCO2 varied between ∼490 and ∼690 µatm, mainly associated with sea surface temperature. Surface pCO2 also displayed substantial diurnal variations, with an average amplitude of 64 ± 21 µatm, largely dominated by biological activities. During the observational period, this site acted as a source of atmospheric CO2, releasing 361 mmol CO2 m-2. The notable diurnal variations in air-sea CO2 flux, such as the observed average amplitude of 10.9 mmol m-2 d-1 in this study, pose a challenge for accurately estimating the air-sea CO2 flux in coastal regions without high-resolution observations.


Asunto(s)
Dióxido de Carbono , Monitoreo del Ambiente , Estaciones del Año , Agua de Mar , Dióxido de Carbono/análisis , Agua de Mar/química , China , Temperatura , Atmósfera/química , Océanos y Mares
16.
Asian J Surg ; 47(5): 2152-2160, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38238140

RESUMEN

PURPOSE: Change in venous-to-arterial carbon dioxide partial pressure difference[P(v-a)CO2] could be a useful marker to assess tissue perfusion status. Herein, we assessed the predictive values of postoperative P(v-a)CO2 measurements for mortality in critically ill patients after major surgery. The correlation between P(v-a)CO2 values and other conventional parameters of patient prognosis was also evaluated. METHODS: Patients admitted to the intensive care unit(ICU) after abdominal surgery were enrolled. Arterial and venous blood gas analyses were performed within 1 h(T0) and after 24 h(T1) of admission to the ICU, respectively. The relationship between P(v-a)CO2 levels at T1 and other conventional parameters were assessed using a Bland-Altman plot. Logistic regression analysis was performed to examine the predisposing factors of mortality after surgery. RESULTS: A total of 231 patients were finally analyzed. We divided the participants into the high PvaCO2 group[P(v-a)CO2 ≥ 8.6] and the low PvaCO2 group[P(v-a)CO2 < 8.6]. Seven-day-, 28-day, and in-hospital mortality were significantly higher in the high PvaCO2 group than in the low PvaCO2 group. There was significant agreement between P(v-a)CO2 values at T1 and APACHE II scores, lactate levels at T1 and total SOFA scores at T1. In multivariate logistic analysis, an increased P(v-a)CO2 value at T1 was the only significant risk factor of 7-day mortality after surgery. [odds ratio:1.341, 95%confidence interval: 1.050-1.714, p=0.019]. CONCLUSION: P(v-a)CO2 measurements could be not only a significant predictor of postoperative prognosis, but also a useful surveillance parameter to maintain tissue perfusion after abdominal surgery in patients with a potential risk of fatal complication-related tissue hypoperfusion.


Asunto(s)
Análisis de los Gases de la Sangre , Dióxido de Carbono , Valor Predictivo de las Pruebas , Humanos , Femenino , Masculino , Dióxido de Carbono/sangre , Persona de Mediana Edad , Pronóstico , Anciano , Arterias , Mortalidad Hospitalaria , Abdomen/cirugía , Enfermedad Crítica , Venas , Unidades de Cuidados Intensivos , Presión Parcial , Biomarcadores/sangre
17.
Ann Card Anaesth ; 26(2): 171-176, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37706382

RESUMEN

Background: Clearance of tissue carbon dioxide by circulation is measured by venous to arterial carbon dioxide partial pressure difference (AVCO2) and is correlated with cardiac output (CO) in critically ill adult patients. This study aimed to correlate AVCO2 with other CO indices like arteriovenous oxygen saturation difference (AVO2), central venous oxygen saturation (ScVO2), and serum lactate in pediatric patients undergoing intracardiac repair (ICR) for tetralogy of Fallot (TOF). Methods: We conducted a prospective observational study in 50 patients, of age 5 months to 5 years, undergoing ICR for TOF and analyzed AVO2, AVCO2, ScVO2, and lactate from arterial and venous blood gas pairs obtained at different time intervals from admission to pediatric intensive care unit (PICU) (T0), at 6 h (T1), 12 h (T2), 24 h (T3), and 48 h (T4) postoperatively. Bivariate correlations were analyzed using Pearson for parametric variables. Results: Admission AVCO2 was not correlated with AVO2 (R2 = 0.166, P = 0.246), ScVO2 (R2 = -2.2, P = 0.124), and lactate (R2 = -0.07, P = 0.624). At T1, AVCO2 was correlated with AVO2 (R2 = 0.283, P = 0.0464) but not with ScVO2 (R2 = - 0.25, P = 0.079) and lactate (R2 = -0.07, P = 0.623). At T2, T3 and T4, AVCO2 was correlated with AVO2 (R2 = 0.338,0.440 & 0.318, P = 0.0162, 0.0013, and 0.024), ScVO2 (R2 = - 0.344, - 0.488, and -0.366; P = 0.0143, <0.0001, and 0.017), and lactate (R2 = 0.305, 0.467 and 0.607; P = 0.0314, 0.00062 and <0.0001). AVCO2 was negatively correlated with ScVO2. No correlation observed between admission AVCO2 and mechanical ventilation duration. Two nonsurvivors had higher value of admission AVCO2 compared to survivors. Conclusion: AVCO2 is correlated with other CO surrogates like AVO2, ScVO2, and lactate in pediatric patients undergoing ICR for TOF.


Asunto(s)
Tetralogía de Fallot , Humanos , Dióxido de Carbono , Gasto Cardíaco , Ácido Láctico , Oxígeno , Presión Parcial , Tetralogía de Fallot/cirugía , Lactante , Preescolar
18.
Pediatr Pulmonol ; 58(10): 2899-2905, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37594148

RESUMEN

OBJECTIVE: Accurate and reliable noninvasive methods to estimate gas exchange are necessary to guide clinical decisions to avoid frequent blood samples in children with pediatric acute respiratory distress syndrome (PARDS). We aimed to investigate the correlation and agreement between end-tidal P CO 2 ${P}_{{\mathrm{CO}}_{2}}$ measured immediately after a 3-s inspiratory-hold (PLAT CO2 ) by capnometry and P aCO 2 ${P}_{{\mathrm{aCO}}_{2}}$ measured by arterial blood gases (ABG) in PARDS. DESIGN: Prospective cohort study. SETTING: Seven-bed Pediatric Intensive Care Unit, Hospital El Carmen de Maipú, Chile. PATIENTS: Thirteen mechanically ventilated patients aged ≤15 years old undergoing neuromuscular blockade as part of management for PARDS. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: All patients were in volume-controlled ventilation mode. The regular end-tidal P CO 2 ( P ETCO 2 ) ${P}_{{\mathrm{CO}}_{2}}({P}_{{\mathrm{ETCO}}_{2}})$ (without the inspiratory hold) was registered immediately after the ABG sample. An inspiratory-hold of 3 s was performed for lung mechanics measurements, recording P ETCO 2 ${P}_{{\mathrm{ETCO}}_{2}}$ in the breath following the inspiratory-hold. (PLAT CO2 ). End-tidal alveolar dead space fraction (AVDSf) was calculated as [ ( P aCO 2 - P ETCO 2 ) / P aCO 2 ] $[({P}_{{\mathrm{aCO}}_{2}}\mbox{--}{P}_{{\mathrm{ETCO}}_{2}})/{P}_{{\mathrm{aCO}}_{2}}]$ and its surrogate (S)AVDSf as [ ( PLAT CO 2 - P ETCO 2 ) / PLAT CO 2 ] $[{(}_{\mathrm{PLAT}}{\mathrm{CO}}_{2}\mbox{--}{P}_{{\mathrm{ETCO}}_{2}}){/}_{\mathrm{PLAT}}{\mathrm{CO}}_{2}]$ . Measurements of P aCO 2 ${P}_{{\mathrm{aCO}}_{2}}$ were considered the gold standard. We performed concordance correlation coefficient (ρc), Spearman's correlation (rho), and Bland-Altmann's analysis (mean difference ± SD [limits of agreement, LoA]). Eleven patients were included, with a median (interquartile range) age of 5 (2-11) months. Tidal volume was 5.8 (5.7-6.3) mL/kg, PEEP 8 (6-8), driving pressure 10 (8-11), and plateau pressure 17 (17-19) cm H2 O. Forty-one paired measurements were analyzed. P aCO 2 ${P}_{{\mathrm{aCO}}_{2}}$ was higher than P ETCO 2 ${P}_{{\mathrm{ETCO}}_{2}}$ (52 mmHg [48-54] vs. 42 mmHg [38-45], p < 0.01), and there were no significant differences with PLAT CO2 (50 mmHg [46-55], p > 0.99). The concordance correlation coefficient and Spearman's correlation between P aCO 2 ${P}_{{\mathrm{aCO}}_{2}}$ and PLAT CO2 were robust (ρc = 0.80 [95% confidence interval [CI]: 0.67-0.90]; and rho = 0.80, p < 0.001.), and for P ETCO 2 ${P}_{{\mathrm{ETCO}}_{2}}$ were weak and strong (ρc = 0.27 [95% CI: 0.15-0.38]; and rho = 0.63, p < 0.01). The bias between PLAT CO2 and P aCO 2 ${P}_{{\mathrm{aCO}}_{2}}$ was -0.4 ± 3.5 mmHg (LoA -7.2 to 6.4), and between P ETCO 2 ${P}_{{\mathrm{ETCO}}_{2}}$ and P aCO 2 ${P}_{{\mathrm{aCO}}_{2}}$ was -8.5 ± 4.1 mmHg (LoA -16.6 to -0.5). The correlation between AVDSf and (S)AVDSf was moderate (rho = 0.55, p < 0.01), and the mean difference was -0.5 ± 5.6% (LoA -11.5 to 10.5). CONCLUSION: This pilot study showed the feasibility of measuring end-tidal CO2 after a 3-s end-inspiratory breath hole in pediatric patients undergoing controlled ventilation for ARDS. Encouraging preliminary results warrant further study of this technique.

19.
Front Cardiovasc Med ; 10: 1085755, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37583587

RESUMEN

The co-existence of atrial septal defect and coronary artery disease in a patient is rare in clinical practice. In the combined surgery of off-pump coronary artery bypass grafting and atrial septal defect closure, the unusual cardiac positions may affect the direction of blood shunting between the atriums, leading to more complex hemodynamic changes. Here, we report a case of a 67-year-old female who underwent refractory hypoxemia related to heart position in such a combined operation.

20.
Adv Ther ; 39(11): 5058-5071, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36050614

RESUMEN

INTRODUCTION: Sepsis is a heterogeneous syndrome that results in life-threatening organ dysfunction. Our goal was to determine the relevant variables and patient phenotypes to use in predicting sepsis outcomes. METHODS: We performed an ancillary study concerning 119 patients with septic shock at intensive care unit (ICU) admittance (T0). We defined clinical worsening as having an increased sequential organ failure assessment (SOFA) score of ≥ 1, 48 h after admission (ΔSOFA ≥ 1). We performed univariate and multivariate analyses based on the 28-day mortality rate and ΔSOFA ≥ 1 and determined three patient phenotypes: safe, intermediate and unsafe. The persistence of the intermediate and unsafe phenotypes after T0 was defined as a poor outcome. RESULTS: At T0, the multivariate analysis showed two variables associated with 28-day mortality rate: norepinephrine dose and serum lactate concentration. Regarding ΔSOFA ≥ 1, we identified three variables at T0: norepinephrine dose, lactate concentration and venous-to-arterial carbon dioxide difference (P(v-a)CO2). At T0, the three phenotypes (safe, intermediate and unsafe) were found in 28 (24%), 70 (59%) and 21 (18%) patients, respectively. We thus suggested using an algorithm featuring norepinephrine dose, lactate concentration and P(v-a)CO2 to predict patient outcomes and obtained an area under the curve (AUC) of 74% (63-85%). CONCLUSION: Our findings highlight the fact that identifying relevant variables and phenotypes may help physicians predict patient outcomes.


Asunto(s)
Sepsis , Choque Séptico , Dióxido de Carbono , Humanos , Unidades de Cuidados Intensivos , Ácido Láctico , Norepinefrina/uso terapéutico , Fenotipo , Pronóstico , Curva ROC , Estudios Retrospectivos , Sepsis/complicaciones , Sepsis/tratamiento farmacológico , Choque Séptico/tratamiento farmacológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA