Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 568
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Small ; 20(7): e2305980, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37800615

RESUMEN

Unclear reaction mechanisms and unsatisfactory power performance hinder the further development of advanced lithium/fluorinated carbon (Li/CFx ) batteries. Herein, the mechano-electrochemical coupling behavior of a CFx cathode is investigated by in situ monitoring strain/stress using digital image correlation (DIC) techniques, electrochemical methods, and theoretical equations. The DIC monitoring results present the distribution and dynamic evolution of the plane strain and indicate strong dependence toward the material structure and discharge rate. The average plane principal strain of fully discharged 2D fluorinated graphene nanosheets (FGNSs) at 0.5 C is 0.50%, which is only 38.5% that of conventional bulk-structure CFx . Furthermore, the superior structural stability of the FGNSs is demonstrated by the microstructure and component characterization before and after discharge. The plane stress evolution is calculated based on theoretical equations, and the contributions of electrochemical and mechanical factors are examined and discussed. Subsequently, a structure-dependent three-region discharge mechanism for CFx electrodes is proposed from a mechanical perspective. Additionally, the surface deformation of Li/FGNSs pouch cells formed during the discharge process is monitored using in situ DIC. This study reveals the discharge mechanism of Li/CFx batteries and facilitates the design of advanced CFx materials.

2.
Sensors (Basel) ; 24(8)2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38676067

RESUMEN

Facial expression is an important way to reflect human emotions and it represents a dynamic deformation process. Analyzing facial movements is an effective means of understanding expressions. However, there is currently a lack of methods capable of analyzing the dynamic details of full-field deformation in expressions. In this paper, in order to enable effective dynamic analysis of expressions, a classic optical measuring method called stereo digital image correlation (stereo-DIC or 3D-DIC) is employed to analyze the deformation fields of facial expressions. The forming processes of six basic facial expressions of certain experimental subjects are analyzed through the displacement and strain fields calculated by 3D-DIC. The displacement fields of each expression exhibit strong consistency with the action units (AUs) defined by the classical Facial Action Coding System (FACS). Moreover, it is shown that the gradient of the displacement, i.e., the strain fields, offers special advantages in characterizing facial expressions due to their localized nature, effectively sensing the nuanced dynamics of facial movements. By processing extensive data, this study demonstrates two featured regions in six basic expressions, one where deformation begins and the other where deformation is most severe. Based on these two regions, the temporal evolutions of the six basic expressions are discussed. The presented investigations demonstrate the superior performance of 3D-DIC in the quantitative analysis of facial expressions. The proposed analytical strategy might have potential value in objectively characterizing human expressions based on quantitative measurement.


Asunto(s)
Expresión Facial , Imagenología Tridimensional , Humanos , Imagenología Tridimensional/métodos , Cara/fisiología , Emociones/fisiología , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos
3.
Molecules ; 29(8)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38675692

RESUMEN

The global production landscape exhibits a substantial need for efficient and clean energy. Enhancing and advancing energy storage systems are a crucial avenue to optimize energy utilization and mitigate costs. Lithium batteries are the most effective and impressive energy utilization system at present, with good safety, high energy density, excellent cycle performance, and other advantages, occupying most of the market. However, due to the defects in the electrode material of the battery itself, the electrode will undergo the process of expansion, stress evolution, and electrode damage during electro-chemical cycling, which will degrade battery performance. Therefore, the detection of property changes in the electrode during electro-chemical cycling, such as the evolution of stress and the modulus change, are useful for preventing the degradation of lithium-ion batteries. This review presents a current overview of measurement systems applied to the performance detection of batteries' electrodes, including the multi-beam optical stress sensor (MOSS) measurement system, the digital image correlation (DIC) measurement system, and the bending curvature measurement system (BCMS), which aims to highlight the measurement principles and advantages of the different systems, summarizes a part of the research methods by using each system, and discusses an effective way to improve the battery performance.

4.
BMC Oral Health ; 24(1): 901, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39107754

RESUMEN

BACKGROUND: Mechanical complications affect the stability of implant restorations and are a key concern for clinicians, especially with the frequent introduction of new implant designs featuring various structures and materials. This study evaluated the effect of different prosthetic index structure types and implant materials on the stress distribution of implant restorations using both in silico and in vitro methods. METHODS: Four finite element analysis (FEA) models of implant restorations were created, incorporating two prosthetic index structures (cross-fit (CF) and torc-fit (TF)) and two implant materials (titanium and titanium-zirconium). A static load was applied to each group. An in vitro study using digital image correlation (DIC) with a research scenario identical to that of the FEA was conducted for validation. The primary strain, sensitivity index, and equivalent von Mises stress were used to evaluate the outcomes. RESULTS: Changing the implant material from titanium to titanium-zirconium did not significantly affect the stress distribution or maximum stress value of other components, except for the implant itself. In the CF group, implants with a lower elastic modulus increased the stress on the screw. The TF group showed better stress distribution on the abutment and a lower stress value on the screw. The TF group demonstrated similar sensitivity for all components. DIC analysis revealed significant differences between TF-TiZr and CF-Ti in terms of the maximum (P < 0.001) and minimum principal strains (P < 0.05) on the implants and the minimum principal strains on the investment materials in both groups (P < 0.001). CONCLUSIONS: Changes in the implant material significantly affected the maximum stress of the implant. The TF group exhibited better structural integrity and reliability.


Asunto(s)
Implantes Dentales , Materiales Dentales , Análisis del Estrés Dental , Análisis de Elementos Finitos , Titanio , Circonio , Circonio/química , Humanos , Materiales Dentales/química , Análisis del Estrés Dental/métodos , Estrés Mecánico , Diseño de Prótesis Dental , Módulo de Elasticidad , Simulación por Computador , Imagenología Tridimensional
5.
Rock Mech Rock Eng ; 57(7): 4679-4706, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39006378

RESUMEN

We employed a novel combination of digital image correlation (DIC) and grain-based hybrid finite-discrete element method (GB-FDEM) to improve the comprehension of the relationships between microstructural features and the mechanical properties of granitic rocks. DIC and numerical results showed that macrocracks initiated and propagated along grain boundaries among different minerals driven by the high stiffness contrast between the compliant biotite and the stiffer feldspar/quartz grains. Surface deformation analyses revealed that tensile-dominated macrocracks open at monotonically increased rates before the crack damage threshold, and the opening accelerated afterwards with the increased shear component. The onset of the acceleration of the opening rate of macrocracks can be used to infer the crack damage threshold. Both strain and acoustic emission were used to infer damage stress thresholds in the synthetic numerical samples. Numerical results showed that the damage stress thresholds and uniaxial compressive strength decrease with increasing grain size following log-linear relations. Coarse-grained samples tend to fail by axial splitting, while fine-grained samples fail by shear zone formation. Biotite and quartz contents significantly affect mechanical properties, while quartz to feldspar ratio is positively related to the mechanical properties. Our study demonstrates the capacities of DIC and GB-FDEM in inferring damage conditions in granitic rocks and clarifies the microstructural control of the macroscopic mechanical behaviors. Our results also provide a comprehensive understanding of the systematics of strain localization, crack development, and acoustic emission during the rock progressive failure process. Supplementary Information: The online version contains supplementary material available at 10.1007/s00603-024-03789-7.

6.
Exp Eye Res ; 236: 109677, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37827443

RESUMEN

Lacking specimens is the biggest limitation of studying the mechanical behaviors of human corneal. Extracting stress-strain curves is the crucial step in investigating hyperelastic and anisotropic properties of human cornea. 15 human corneal specimens extracted from the small incision lenticule extraction (SMILE) surgery were applied in this study. To accurately measure the personalized true stress-strain curve using corneal lenticules, the digital image correlation (DIC) method and finite element method were used to calibrate the stress and the strain of the biaxial extension test. The hyperelastic load-displacement curves obtained from the biaxial extension test were performed in preferential fibril orientations, which are arranged along the nasal-temporal (NT) and the superior-inferior (SI) directions within the anterior central stroma. The displacement and strain fields were accurately calibrated and calculated using the digital image correlation (DIC) method. A conversion equation was given to convert the effective engineering strain to the true strain. The stress field distribution, which was simulated using the finite element method, was verified. Based on this, the effective nominal stress with personalized characteristics was calibrated. The personalized stress-strain curves containing individual characteristic, like diopter and anterior surface curvature, was accurately measured in this study. These results provide an experimental method using biaxial tensile test with corneal lenticules. It is the foundation for investigating the hyperelasticity and anisotropy of the central anterior stroma of human cornea.


Asunto(s)
Córnea , Sustancia Propia , Humanos , Anisotropía , Calibración , Análisis de Elementos Finitos
7.
Biomed Eng Online ; 22(1): 13, 2023 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-36774524

RESUMEN

The response of soft tissue to loading can be obtained by strain assessment. Typically, strain can be measured using electrical resistance with strain gauges (SG), or optical sensors based on the digital image correlation (DIC), among others. These sensor systems are already established in other areas of technology. However, sensors have a limited range of applications in medical technology due to various challenges in handling human soft materials. The aim of this study was to compare directly attached foil-type SG and 3D-DIC to determine the strain of axially loaded human ligament structures. Therefore, the medial (MCL) and lateral (LCL) collateral ligaments of 18 human knee joints underwent cyclic displacement-controlled loading at a rate of 20 mm/min in two test trials. In the first trial, strain was recorded with the 3D-DIC system and the reference strain of the testing machine. In the second trial, strain was additionally measured with a directly attached SG. The results of the strain measurement with the 3D-DIC system did not differ significantly from the reference strain in the first trial. The strains assessed in the second trial between reference and SG, as well as between reference and 3D-DIC showed significant differences. This suggests that using an optical system based on the DIC with a given unrestricted view is an effective method to measure the superficial strain of human ligaments. In contrast, directly attached SGs provide only qualitative comparable results. Therefore, their scope on human ligaments is limited to the evaluation of changes under different conditions.


Asunto(s)
Ligamentos Colaterales , Humanos , Fenómenos Biomecánicos , Ligamentos Colaterales/fisiología , Articulación de la Rodilla/fisiología , Imagenología Tridimensional , Estrés Mecánico
8.
Microsc Microanal ; 29(2): 580-595, 2023 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-37749723

RESUMEN

Plastic deformation is accumulated in slip bands in a wide variety of engineering alloys. Multiple material and loading conditions impact their distribution and degree of slip localization, but these effects are rarely quantified. To tackle this, the current work introduces a fast Fourier transform (FFT) decomposition method and applies it to a tensile-loaded polycrystalline nickel-based superalloy imaged via high-resolution digital image correlation and electron backscatter diffraction. This approach identifies active slip planes over the FFT images of individual grains and performs inverse transforms such that slip band traces with shared orientations are isolated. This technique enabled the largest quantification of slip band spacings and in-plane strains to date, with a total of 6,557 slip bands detected. The results show that the slip band spacings increase with grain size, with no evident dependence on grain orientation and Schmid factor. Slip bands are found to develop similar spacings along different octahedral planes and continue to spread over larger regions of the grain as the resolved shear stress of the active slip system increases. The FFT decomposition technique, which could be employed with multiple microscopy techniques, will allow for much-needed large-scale quantitative studies of slip localization.

9.
Sensors (Basel) ; 23(6)2023 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-36992028

RESUMEN

To solve the problems of the traditional 3D-DIC algorithm based on feature information or FFT search at the expense of accuracy in exchange for time, such as error-point extraction, mismatching of feature points, poor robustness, and accuracy loss caused by poor anti-noise performance, an improved high-precision 3D-DIC measurement method was proposed. In this method, the exact initial value is obtained by an exhaustive search. Then, the forward Newton iteration method is used for pixel classification, and the first-order nine-point interpolation is designed, which can quickly obtain the elements of Jacobian and Hazen matrix, and achieve accurate sub-pixel positioning. The experimental results show that the improved method has high accuracy, and its mean error and standard deviation stability and extreme value are better than similar algorithms. Compared with the traditional forward Newton method, the total iteration time of the improved forward Newton method is reduced in the subpixel iteration stage, and the computational efficiency is 3.8 times that of the traditional NR algorithm. The whole process of the proposed algorithm is simple and efficient, and it has application value in the precision occasions requiring high precision.

10.
Sensors (Basel) ; 23(2)2023 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-36679591

RESUMEN

Structural Health Monitoring (SHM) systems allow three types of diagnostic tasks to be performed, namely damage identification, loads monitoring, and damage prognosis. Only if all three tasks are correctly fulfilled can the useful remaining life of a structure be estimated credibly. This paper deals with the second task and aimed to extend state-of-the-art in load identification, by demonstrating that it is feasible to achieve it through the analysis of response signals captured with high-speed three-dimensional Digital Image Correlation (HS 3D-DIC). The efficacy of the proposed procedure is demonstrated experimentally on a frame structure under broadband vibration excitation. Full-field vibration displacement signals are captured with the use of two high-speed cameras and processed with 3D-DIC. Loads are identified with two different algorithms based on inverting the Frequency Response Function (FRF) matrix and modal filtration (MF). The paper discusses both methods providing their theoretical background and experimental performance.


Asunto(s)
Algoritmos , Imagenología Tridimensional , Imagenología Tridimensional/métodos , Vibración , Electrocardiografía
11.
Sensors (Basel) ; 23(8)2023 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-37112175

RESUMEN

Digital image-correlation (DIC) algorithms rely heavily on the accuracy of the initial values provided by whole-pixel search algorithms for structural displacement monitoring. When the measured displacement is too large or exceeds the search domain, the calculation time and memory consumption of the DIC algorithm will increase greatly, and even fail to obtain the correct result. The paper introduced two edge-detection algorithms, Canny and Zernike moments in digital image-processing (DIP) technology, to perform geometric fitting and sub-pixel positioning on the specific pattern target pasted on the measurement position, and to obtain the structural displacement according to the change of the target position before and after deformation. This paper compared the difference between edge detection and DIC in accuracy and calculation speed through numerical simulation, laboratory, and field tests. The study demonstrated that the structural displacement test based on edge detection is slightly inferior to the DIC algorithm in terms of accuracy and stability. As the search domain of the DIC algorithm becomes larger, its calculation speed decreases sharply, and is obviously slower than the Canny and Zernike moment algorithms.

12.
Sensors (Basel) ; 23(17)2023 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-37688112

RESUMEN

Reliable and accurate full-field deformation measurements at elevated temperatures using digital image correlation (DIC) require stable and high-contrast high-temperature speckle patterns to be prepared on the sample surface. However, conventional high-temperature speckle patterns fabricated by the existing methods possess several limitations, e.g., easily fail to preserve original pattern features due to the harsh environment and heavily dependent on the operator's experience. In this study, we propose a reliable and reproducible high-temperature speckle fabrication method based on air plasma spraying (APS) and flexible speckle templates. This method involves covering the sample surface with pre-designed speckle templates and then spraying the melted speckle powders onto the specimen surface using an air plasma spray technique to obtain customized speckle patterns. The validity of the proposed method was verified by the speckle fabrication on both planar and curved samples and heating tests with these samples. Experimental results demonstrate that the speckle patterns made by the proposed method adhere well to the sample surface, remain stable during the heating process, and exhibit excellent agreement with the reference values in terms of the thermal expansion coefficients. The proposed method provides a reliable and efficient way to create customized and stable speckle patterns for accurate high-temperature DIC measurements.

13.
Sensors (Basel) ; 23(20)2023 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-37896579

RESUMEN

This paper aims to explore the structural performance of 3D-printed and casted cement-based steel-reinforced concrete beams and one-way slabs incorporating short carbon fibre and activated carbon powder, which have been shown to enhance concrete's flexural strength and reduce its electrical resistivity. The samples are cast and printed in 250 × 325 × 3500 mm beams and 150 × 400 × 3500 mm one-way slabs and mechanical, electrical, and piezoresistivity properties were measured. This length of beams and one-way slabs with rebars have been considered as they can magnify the flexural and cracking behaviour and make them easier to be monitored and analysed. The samples were loaded up to 80% of maximum stress. Crack propagation and strain was assessed using the 2D digital image correlation (DIC) method. The results compared samples under continuously increasing loads between 3D-printed and cast samples. The 3D-printed composites had a better piezoresistive response due to the enhanced anisotropic behaviour. DIC analysis illustrated similar results among different samples, while 3D-printed blocks had lower cracking performance due to the horizontal case fracture in lower stress.

14.
Sensors (Basel) ; 23(21)2023 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-37960631

RESUMEN

Fiber-reinforced polymer (FRP) strengthening systems have been considered an effective technique to retrofit concrete structures, and their use nowadays is more and more extensive. Externally bonded reinforcement (EBR) and near-surface mounted (NSM) technologies are the two most widely recognized and applied FRP strengthening methods for enhancing structural performance worldwide. However, one of the main disadvantages of both approaches is a possible brittle failure mode provided by a sudden debonding of the FRP. Therefore, methodologies able to monitor the long-term efficiency of this kind of strengthening constitute a challenge to be overcome. In this work, two reinforced concrete (RC) specimens strengthened with FRP and subjected to increasing load tests were monitored. One specimen was strengthened using the EBR method, while for the other, the NSM technique was used. The multiple cracks emanating in both specimens in the static tests, as possible origins of a future debonding failure, were monitored using a piezoelectric (PZT)-transducer-based electromechanical impedance (EMI) technique and a digital image correlation (DIC) system. Clustering approaches based on impedance measurements of the healthy and damaged states of the specimens allowed us to suspect the occurrence of cracks and their growth. The strain profiles captured in the images of the DIC system allowed us to depict surface hair-line cracks and their propagation. The combined implementation of the two techniques to look for correlations during incremental bending tests was addressed in this study as a means of improving the prediction of early cracks and potentially anticipating the complete failure of the strengthened specimens.

15.
Sensors (Basel) ; 23(23)2023 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-38067735

RESUMEN

Digital image correlation (DIC) is an optical technique used to measure surface displacements and strains in materials and structures. This technique has demonstrated significant utility in structural examination and monitoring. This manuscript offers a comprehensive review of the contemporary research and applications that have leveraged the DIC technique in laboratory-based structural tests. The reviewed works encompass a broad spectrum of structural components, such as concrete beams, columns, pillars, masonry walls, infills, composite materials, structural joints, steel beams, slabs, and other structural elements. These investigations have underscored the efficacy of DIC as a metrological instrument for the precise quantification of surface deformation and strain in these structural components. Moreover, the constraints of the DIC technique have been highlighted, especially in scenarios involving extensive or complex test configurations. Notwithstanding these constraints, the effectiveness of the DIC methodology has been validated as a strain measurement instrument, offering numerous benefits such as non-invasive operation, full-field measurement capability, high precision, real-time surveillance, and compatibility with integration into other measurement instruments and methodologies.

16.
Sensors (Basel) ; 23(16)2023 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-37631655

RESUMEN

The stability and repeatability of laser metal deposition is particularly important when processing multiple layers or depositing material on complex component surfaces, and requires the use of process parameter control including the stand-off distance between the laser head and the substrate. The system proposed in this paper for correcting the stand-off parameter is based on a chromatic confocal sensor integrated into a laser head. Then, the spectral signal acquired from the measurement system is processed by using the developed application to compensate for the movement of an additional axis of the kinematic system. This study used an independent verification system based on the digital image correlation method. The validation tests were carried out using the system for correcting the stand-off parameter with different control algorithms and given motion trajectories and substrate materials. The results demonstrate that the developed system can be useful for laser metal deposition.

17.
Sensors (Basel) ; 23(24)2023 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-38139640

RESUMEN

In this work, the strains measured with optic fibers and recorded during tensile tests performed on carbon/epoxy composite specimens were compared to those recorded by strain gauges and by Digital Image Correlation (DIC). The work aims at investigating the sensitivity of embedded and glued optic sensors for structural health monitoring applications in comparison with strain gauges and the full field strain map of the DIC. Acrylate, polyimide optic fibers, and three strain gauge sizes are considered to compare the three techniques. Results show hard polyimide-coated sensors are more sensitive to the material pattern than soft acrylate-coated fibers, which also require extensive adhesion length. The work shows a comparable size of strain gauges and material meso-structure is also critical for properly assessing material properties. The Young's modulus computed with the three different techniques is used to define a strategy that supports the selection and the proper size of the adopted strain measuring system for structural health monitoring of composite materials.

18.
Sensors (Basel) ; 23(2)2023 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-36679475

RESUMEN

Fringe projection profilometry (FPP) and digital image correlation (DIC) are widely applied in three-dimensional (3D) measurements. The combination of DIC and FPP can effectively overcome their respective shortcomings. However, the speckle on the surface of an object seriously affects the quality and modulation of fringe images captured by cameras, which will lead to non-negligible errors in the measurement results. In this paper, we propose a fringe image extraction method based on deep learning technology, which transforms speckle-embedded fringe images into speckle-free fringe images. The principle of the proposed method, 3D coordinate calculation, and deformation measurements are introduced. Compared with the traditional 3D-DIC method, the experimental results show that this method is effective and precise.


Asunto(s)
Tecnología
19.
Sensors (Basel) ; 23(17)2023 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-37687943

RESUMEN

A feasible and precise method to measure ligament strain during surgical interventions could significantly enhance the quality of ligament reconstructions. However, all existing scientific approaches to measure in vivo ligament strain possess at least one significant disadvantage, such as the impairment of the anatomical structure. Seeking a more advantageous method, this paper proposes defining medical and technical requirements for a non-destructive, optical measurement technique. Furthermore, we offer a comprehensive review of current optical endoscopic techniques which could potentially be suitable for in vivo ligament strain measurement, along with the most suitable optical measurement techniques. The most promising options are rated based on the defined explicit and implicit requirements. Three methods were identified as promising candidates for a precise optical measurement of the alteration of a ligaments strain: confocal chromatic imaging, shearography, and digital image correlation.


Asunto(s)
Ligamentos , Ligamentos/diagnóstico por imagen , Ligamentos/cirugía , Humanos , Endoscopía
20.
Sensors (Basel) ; 23(15)2023 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-37571447

RESUMEN

We propose a novel hybrid FPP-DIC technique to measure an object's shape and deformation in 3D simultaneously by using a single 3CCD color camera, which captures the blue fringe patterns and red fluorescent speckles within the same image. Firstly, red fluorescent speckles were painted on the surface of the specimen. Subsequently, 12 computer-generated blue fringe patterns with a black background were projected onto the surface of the specimen using a DLP projector. Finally, both the reference and deformed images with three different frequencies and four shifted phases were captured using a 3CCD camera. This technique employed a three-chip configuration in which red-green-blue chips were discretely integrated in the 3CCD color camera sensor, rendering independent capture of RGB information possible. Measurement of out-of-plane displacement was carried out through the implementation of Fringe Projection Profilometry (FPP), whereas the in-plane displacement was evaluated using a 2D Digital Image Correlation (DIC) method by leveraging a telecentric-lens-based optical system. In comparison to the traditional FPP-DIC hybrid methodology, the present approach showed a lower incidence of crosstalk between the fringe patterns and speckle patterns while also offering a corrective for the coupling of the in-plane displacement and out-of-plane displacement. Experimental results for the in-plane cantilever beam and out-of-plane disk comparisons with the traditional 3D-DIC method indicated that the maximum discrepancy obtained between FPP-DIC and 3D-DIC was 0.7 µm and 0.034 mm with different magnifications, respectively, validating the effectiveness and precision of the novel proposed FPP-DIC method.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA