Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Nanotechnology ; 35(21)2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38320325

RESUMEN

Metasurface is a new type of micro-optical element developed in recent years. It can intelligently modulate electromagnetic waves by adjusting the geometrical parameters and arrangement of dielectric structures. In this paper, a bifocal metalens based on modulation of propagation phase was designed for the potential application in displacement measurement. The phase of the bifocal lens is designed by the optical holography-like method, which is verified by the scalar diffraction theory. We designed a square aperture lens with a side length of 200µm to realize two focal spots with focal lengths of 900 and 1100µm. The two focal spots aren't on one optical axis. The polarization insensitive TiO2cylinders are chosen as structure units. Four structures with different radius were selected to achieve the four phase steps. We fabricated the designed bifocal metalens using electron beam lithography and atomic layer deposition techniques, and measured the light intensity in the areas near the two foci in the direction of the longitudinal axis. The differential signal was calculated, from which we obtained a linear interval. It demonstrates the ability of bifocal differential measurement to be applied to displacement measurement. Because the metasurfaces production process is semiconductor compatible, the bifocal lens is easy to integrate and can be used for miniaturized displacement measurements, micro-resonators, acceleration measurements, and so on.

2.
Sensors (Basel) ; 24(6)2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38544193

RESUMEN

UAVs have been widely used in deformation monitoring because of their high availability and flexibility. However, the quality of UAV images is affected by changing attitude and surveying environments, resulting in a low monitoring accuracy. Cross-shaped markers are used to improve the accuracy of UAV monitoring due to their distinct center contrast and absence of eccentricity. However, existing methods cannot rapidly and precisely detect these markers in UAV images. To address these problems, this paper proposes an adaptive Radon-transform-based marker detection and localization method for UAV displacement measurements, focusing on two critical detection parameters, namely, the radius of marker information acquisition and the edge width of the cross-shaped scoring template. The experimental results show that the marker detection rate is 97.2% under different combinations of flight altitudes, radius ratios of marker information acquisition, and marker sizes. Furthermore, the root mean square error of detection and localization is 0.57 pixels, significantly surpassing the performance and accuracy of other methods. We also derive the critical detection radius and appropriate parameter combinations for different heights to further improve the practicality of the method.

3.
Sensors (Basel) ; 24(6)2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38544232

RESUMEN

Low-frequency and 1/f noise are common measurement limitations that arise in a variety of physical processes. Mitigation methods for these noises are dependent on their source. Here, we present a method for removing 1/f noise of optical origin using a micro-cavity Fabry-Pérot (FP) interferometer. A mechanical modulation of the FP cavity length was applied to a previously studied opto-mechanical sensor. It effectively mimics an up-conversion of the laser frequency, shifting signals to a region where lower white-noise sources dominate and 1/f noise is not present. Demodulation of this signal shifts the results back to the desired frequency range of observation with the reduced noise floor of the higher frequencies. This method was found to improve sensitivities by nearly two orders of magnitude at 1 Hz and eliminated 1/f noise in the range from 1 Hz to 4 kHz. A mathematical model for low-finesse FP cavities is presented to support these results. This study suggests a relatively simple and efficient method for 1/f noise suppression and improving the device sensitivity of systems with an FP interferometer readout.

4.
Sensors (Basel) ; 24(9)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38732829

RESUMEN

In 3D microsphere tracking, unlike in-plane motion that can be measured directly by a microscope, axial displacements are resolved by optical interference or a diffraction model. As a result, the axial results are affected by the environmental noise. The immunity to environmental noise increases with measurement accuracy and the signal-to-noise ratio (SNR). In compound digital holography microscopy (CDHM)-based measurements, precise identification of the tracking marker is critical to ensuring measurement precision. The reconstruction centering method (RCM) was proposed to suppress the drawbacks caused by installation errors and, at the same time, improve the correct identification of the tracking marker. The reconstructed center is considered to be the center of the microsphere, rather than the center of imaging in conventional digital holographic microscopy. This method was verified by simulation of rays tracing through microspheres and axial moving experiments. The axial displacements of silica microspheres with diameters of 5 µm and 10 µm were tested by CDHM in combination with the RCM. As a result, the SNR of the proposed method was improved by around 30%. In addition, the method was successfully applied to axial displacement measurements of overlapped microspheres with a resolution of 2 nm.

5.
Sensors (Basel) ; 24(9)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38732879

RESUMEN

Grating (moiré) interferometry is one of the well-known methods for full-field in-plane displacement and strain measurement. There are many design solutions for grating interferometers, including systems with a microinterferometric waveguide head. This article proposes a modification to the conventional waveguide interferometer head, enabling the implementation of a polarization fringe phase shift for automatic fringe pattern analysis. This article presents both the theoretical considerations associated with the proposed solution and its experimental verification, along with the concept of in-plane displacement/strain sensing using the described head.

6.
Sensors (Basel) ; 23(4)2023 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-36850482

RESUMEN

Computer vision-based displacement measurement techniques are increasingly used for structural health monitoring. However, the vision sensors employed are easily affected by optical turbulence when capturing images of the structure, resulting in displacement measurement errors that significantly reduce the accuracy required in engineering applications. Hence, this paper develops a multi-measurement point method to address this problem by mitigating optical-turbulence errors with spatial randomness. Then, the effectiveness of the proposed method in mitigating optical-turbulence errors is verified by static target experiments, in which the RMSE correction rate can reach up to 82%. Meanwhile, the effects of target size and the number of measurement points on the proposed method are evaluated, and the optimal target design criteria are proposed to improve our method's performance in mitigating optical-turbulence errors under different measurement conditions. Additionally, extensive dynamic target experiments reveal that the proposed method achieves an RMSE correction rate of 69% after mitigating the optical-turbulence error. The experimental results demonstrate that the proposed method improves the visual displacement measurement accuracy and retains the detailed information of the displacement measurement results.

7.
Sensors (Basel) ; 23(3)2023 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-36772310

RESUMEN

The polymer technology based on Electroactive polymers and metal composite ionic polymer has great potential and advantages in many engineering fields. In this paper, a laboratory stand for testing Ionic polymer-metal composites (IPMC) is presented. The laboratory station includes a power supply system and a measuring system for the displacement of IPMC composites. Tests and measurements are carried out using a laser transducer and a camera equipped with image analysis software to determine the IPMC strips displacement. The experimental investigation of IPMCs under different voltage supplies and waveforms, environmental working humidity conditions, temperature, and loading conditions has proved the significant influence of geometric dimension and the effect of increased stress on the displacement value. For materials powered by a higher voltage value, an increased deflection value was noted. In case of displacement, longer is the sample, higher is the displacement value. The length of the sample under load, affects adversely its performance, resulting in an increase in the load on the sample. For samples of a thick size, a more stable movement with and without load can be noticed.

8.
Sensors (Basel) ; 23(23)2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38067917

RESUMEN

This research paper introduces an innovative technique for measuring displacement using auxetic tubular structure (ATS). The proposed displacement measurement method is based on tubular structures with a negative Poisson's ratio. It capitalizes on the underlying principle that the elastic deformation-induced change in transmittance of the ATS can be translated into a corresponding modification in the output current of the solar cell. This method allows for the conversion of the variation in light transmission into a corresponding variation in output voltage. The construction of the ATS can be achieved through 3D-printing technology, enhancing the accessibility of displacement measurement and design flexibility. The experimental results demonstrate that the proposed measurement method exhibits a linear error of less than 8% without any subsequent signal processing and achieves a sensitivity of 0.011 V/mm without signal amplification. Furthermore, experimental results also show that the proposed method has good repeatability and can maintain a high level of reliability and sensitivity when using different measurement devices. This confirms the effectiveness and feasibility of the proposed method, showing a favorable linear relationship between the input and output of the measurement system with an acceptable sensitivity, repeatability, and reliability.

9.
Sensors (Basel) ; 23(8)2023 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-37112362

RESUMEN

A compact and high-precision three-degrees-of-freedom (DOF; X, Y, and Z directions) grating encoder based on the quadrangular frustum pyramid (QFP) prisms is proposed in this paper to solve the insufficient installation space problem of the reading head of the multi-DOF in high-precision displacement measurement applications. The encoder is based on the grating diffraction and interference principle, and a three-DOF measurement platform is built through the self-collimation function of the miniaturized QFP prism. The overall size of the reading head is 12.3 × 7.7 × 3 cm3 and has the potential for further miniaturization. The test results show that three-DOF measurements can be realized simultaneously in the range of X-250, Y-200, and Z-100 µm due to the limitations of the measurement grating size. The measurement accuracy of the main displacement is below 500 nm on average; the minimum and maximum errors are 0.0708% and 2.8422%, respectively. This design will help further popularize the research and applications of multi-DOF grating encoders in high-precision measurements.

10.
Sensors (Basel) ; 23(20)2023 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-37896590

RESUMEN

The current civil infrastructure conditions can be assessed through the measurement of displacement using conventional contact-type sensors. To address the disadvantages of traditional sensors, vision-based sensor measurement systems have been derived in numerous studies and proven as an alternative to traditional sensors. Despite the benefits of the vision sensor, it is well known that the accuracy of the vision-based displacement measurement is largely dependent on the camera extrinsic or intrinsic parameters. In this study, the feasibility study of a deep learning-based single image super-resolution (SISR) technique in a vision-based sensor system is conducted to alleviate the low spatial resolution of image frames at long measurement distance ranges. Additionally, its robustness is evaluated using shaking table tests. As a result, it is confirmed that the SISR can reconstruct definite images of natural targets resulting in an extension of the measurement distance range. Additionally, it is determined that the SISR mitigates displacement measurement error in the vision sensor-based measurement system. Based on this fundamental study of SISR in the feature point-based measurement system, further analysis such as modal analysis, damage detection, and so forth should be continued in order to explore the functionality of SR images by applying low-resolution displacement measurement footage.

11.
Sensors (Basel) ; 23(18)2023 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-37765920

RESUMEN

Bridge inspection and monitoring are usually used to evaluate the status and integrity of bridge structures to ensure their safety and reliability. Computer vision (CV)-based methods have the advantages of being low cost, simple to operate, remote, and non-contact, and have been widely used in bridge inspection and monitoring in recent years. Therefore, this paper reviews three significant aspects of CV-based methods, including surface defect detection, vibration measurement, and vehicle parameter identification. Firstly, the general procedure for CV-based surface defect detection is introduced, and its application for the detection of cracks, concrete spalling, steel corrosion, and multi-defects is reviewed, followed by the robot platforms for surface defect detection. Secondly, the basic principle of CV-based vibration measurement is introduced, followed by the application of displacement measurement, modal identification, and damage identification. Finally, the CV-based vehicle parameter identification methods are introduced and their application for the identification of temporal and spatial parameters, weight parameters, and multi-parameters are summarized. This comprehensive literature review aims to provide guidance for selecting appropriate CV-based methods for bridge inspection and monitoring.

12.
Sensors (Basel) ; 22(24)2022 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-36560274

RESUMEN

This paper presents a fiber-based chromatic dispersion probe for the simultaneous measurement of dual-axis absolute and relative displacement with nanometric resolutions. The proposed chromatic dispersion probe is based on optical dispersion. In the probe, the employed light beam is split into two sub-beams, and then the two sub-beams are made to pass through two optical paths with different optical settings where two identical single-mode fiber detectors are located at different defocused positions of the respective dispersive lenses. In this way, two spectral signals can be obtained to indicate the absolute displacement of each of the dual-axes. A signal processing algorithm is proposed to generate a normalized output wavelength that indicates the relative displacement of the dual-axis. With the proposed chromatic dispersion probe, the absolute and relative displacement measurements of the dual-axis can be realized simultaneously. Theoretical and experimental investigations reveal that the developed chromatic dispersion probe realizes an absolute measurement range and a measurement resolution of approximately 180 µm and 50 nm, respectively, for each axis. Moreover, a relative displacement measurement range and a measurement resolution of about 240 µm and 100 nm, respectively, are achieved for the dual-axis.

13.
Sensors (Basel) ; 22(5)2022 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-35271106

RESUMEN

Measuring displacement is essential for assessing the safety of bridges. Non-contact sensors such as vision sensors can precisely measure displacement but may be expensive or incapable of micro-scale measurement at a low cost, unlike contact displacement sensors, which are economical but challenging to install. This study proposes an economical, remote non-contact sensor system. The system comprises a laser beam transmitter and a light receiver, deriving the displacement based on the position where the laser beam is irradiated to the light-receiving surface. To measure this, the light receiver was installed at the measurement point and included a wireless communicator to transmit the displacement data. A displacement experiment was conducted to evaluate the performance. The results confirmed that precise displacement measurements were possible at a resolution of 100 µm. For bridge load tests, a light receiver under a bridge was installed, laser beams irradiated to the light-receiving surface from a distance, and the displacement was measured for each test and compared with the values measured by a conventional contact sensor. The results were highly consistent with those of the existing sensor, indicating that the proposed sensor system applies to bridge loading tests and the safety diagnosis for various structures.


Asunto(s)
Luz , Transductores , Rayos Láser
14.
Sensors (Basel) ; 22(10)2022 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-35632147

RESUMEN

Grating interferometers that use large two-dimensional grating splice modules for performing wide-range measurements have significant advantages for identifying the position of the wafer stage. However, the manufacturing process of large two-dimensional grating splice modules is very difficult. In contrast to existing redundant designs in the grating line dimension, we propose a novel interferometric reading head with a redundant design for obtaining wide-range displacement measurements. This interferometric reading head uses a one-dimensional grating splice module, and it was observed to be compatible with two orthogonal gratings. We designed a grating interferometer system composed of four reading heads to achieve a wide range of measurements and verified it using ZEMAX simulation. By conducting experiments, we were able to verify the compatibility of the reading head with gratings possessing different grating line directions; the measurement noise was found to be less than 0.3 nm.

15.
Sensors (Basel) ; 22(12)2022 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-35746143

RESUMEN

To improve the accuracy of the current vision-based linear displacement measurement in a large range, a new type of linear displacement sensing system, namely, image grating, is proposed in this paper. The proposed system included a patterned glass plate attached to the moving object and an ultra-low distortion lens for high-accuracy image matching. A DFT local up-sampling phase correlation method was adopted to obtain the sub-pixel translation of the patterns onto the target plate. Multiple sets of stripe patterns with different designs were located on the glass plate to expand the measurement range, based on the principle of phase correlation. In order to improve the measurement accuracy, the main errors of the image grating system were analyzed, and the nonlinear error compensation was completed based on the dynamic calibration of the pixel equivalent. The measurement results, after the error compensation, showed that the total error of the proposed system was less than 2.5 µm in the range of 60 mm, and the repeatability was within 0.16 µm, as quantified by standard deviation.

16.
Sensors (Basel) ; 22(3)2022 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-35161708

RESUMEN

Recent tragedies around the world have shown how accidents in the cable-stayed bridges can wreak havoc on the society. To ensure the safety of the cable-stayed bridges, several studies have estimated the cable tension force using the vibration of cables. Most of these methods for estimating the tension of a cable start with measuring the displacement of the cable. Recent development of commercial cameras provide opportunity for more convenient and efficient method for measuring the displacement of cable. However, traditional vision-based displacement measurement methods require the assumption that the movement of the cable should be measured in parallel to the camera plane. This assumption limits the installation location of the camera when measuring the displacement of a cable. Therefore, this study introduces a new vision-based cable displacement measurement system that can measure the displacement of a cable in various locations even when the camera is installed in the side of the cable. The proposed method consists of three phases: (1) camera projection matrix estimation, (2) cable tracking in the image coordinate, and (3) cable displacement estimation in the world coordinate. To validate the performance of the proposed method, a simulation-based validation test, a lab-scale validation test, and an on-site validation test were conducted. The simulation-based validation test verified the performance of the proposed method in an ideal condition, and the lab-scale validation test showed the performance of the method in physical environment. Finally, the on-site validation test showed that the proposed method can measure the cable displacement with a side view camera.


Asunto(s)
Movimiento , Vibración , Simulación por Computador
17.
Sensors (Basel) ; 22(22)2022 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-36433401

RESUMEN

Under some unexpected conditions, drive rods and control-rod assemblies may not be disconnected. If this situation is not detected, the control rod will be lifted out of the reactor core together with the upper reactor internals. This situation will seriously affect the follow-up work and reduce the economy and safety protection of the nuclear power plant. To ensure safety, the tripping status must be checked after tripping. Follow-up work can be carried out after checking and confirming that all drive rods are in the tripping status. There are many problems for traditional inspection methods, such as misjudgment, low accuracy, and labor consumption. This paper proposes a visual inspection system for the uncoupling state of the control-rod drive rod of the nuclear reactor. The proposed method is based on the fitting model of the ellipse parameter of the drive-rod head and the height of the drive rod. The ellipse of the drive-rod head is firstly accurately detected. Then, a mathematical model between the ellipse parameter and the height of the drive rod is established. The measurement error caused by the swing of the head of the drive rod is eliminated. The accurate measurement of the height difference before and after the tripping of the drive rod is computed. Finally, the status of the uncoupling of the drive rod is judged according to the difference. Many experiments are carried out with our developed system. The experimental results show that the proposed system realizes remote operation, ensures the quality of trip-status inspection, improves work efficiency, and reduces the workload of staff.


Asunto(s)
Plantas de Energía Nuclear , Reactores Nucleares , Humanos
18.
Sensors (Basel) ; 22(24)2022 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-36560378

RESUMEN

When using off-axis digital image correlation (DIC) for non-contact, remote, and multipoint deflection monitoring of engineering structures, accurate calibration of the scale factor (SF), which converts image displacement to physical displacement for each measurement point, is critical to realize high-quality displacement measurement. In this work, based on the distortion-free pinhole imaging model, a generalized SF calibration model is proposed for an off-axis DIC-based video deflectometer. Then, the transversal relationship between the proposed SF calibration method and three commonly used SF calibration methods was discussed. The accuracy of these SF calibration methods was also compared using indoor rigid body translation experiments. It is proved that the proposed method can be degraded to one of the existing calibration methods in most cases, but will provide more accurate results under the following four conditions: (1) the camera's pitch angle is more than 20°, (2) the focal length is more than 25 mm, (3) the pixel size of the camera sensor is more than 5 um, and (4) the image y-coordinate corresponding to the measurement point after deformation is far from the image center.

19.
Sensors (Basel) ; 22(9)2022 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-35591127

RESUMEN

The spherical pair has an important role in the inner frame of the stabilization mechanism of the aviation optoelectronic pod. However, its two-degrees-of-freedom (2-DOF) angular displacement signal is difficult to detect, seriously restricting its application in aviation optoelectronic pods. Therefore, this study proposes a new method to measure a spherical pair's 2-DOF angular displacement using a spherical capacitive sensor. The capacitive sensor presented by this method realizes the measurement of the 2-DOF angular displacement of the spherical pair by integrating the spherical electrode groups in the ball head and the ball socket of the spherical pair. First, based on the geometric structure of the spherical pair, the structure of the capacitive sensor is designed, and the mathematical model for the capacitive sensor is deduced. Then, the sensor's output capacitance, in different directions, is simulated by Ansoft Maxwell software. Finally, an experiment device is built for the measurement experiments. The simulation analysis and experimental results show that the spherical capacitive sensor has an approximately linear output in different directions, and the measured output capacitance is as high as 89.7% of the theoretical value. Compared with the existing sensors that measure the 2-DOF angular displacement signal of the ball pair, the sensor proposed in this study has an integrated structure, which can be integrated into the spherical pair. That makes it possible to apply the spherical pair to the inner frame of the aviation optoelectronic pod.

20.
Sensors (Basel) ; 23(1)2022 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-36616648

RESUMEN

In this paper, a fiber-based chromatic dispersion probe for simultaneous measurement of X-axis and Z-axis displacements with nanometric resolutions by using the full width at half maxima (FWHM) of the detected spectral signal has been proposed and demonstrated. For X-axis, FWHM is employed for indicating the X-axis displacement based on the fact that the FWHM remains almost constant with the varying Z-axis displacement of the fiber detector and shows a linear relationship with the X-axis displacement within a specific Z-axis displacement range. For the Z-axis, the linear relationship between the centroid wavelength λ of the detected spectral signal and the Z-axis displacement is employed for indicating the Z-axis displacement based on the fact that the sensitivity (slope of the λ-Z curve) is also linear with X-axis displacement within a certain X-axis displacement range. Theoretical and experimental investigations have verified the feasibility of the proposed chromatic dispersion probe, which yields X- and Z-axis measurement ranges of 2.3 µm and 15 µm and X- and Z-axis measurement resolutions of better than 25 nm and 50 nm, respectively. Experiments were further performed to evaluate the basic performance of the prototype probe and the maximum measurement errors were less than 10 nm and 60 nm for X- and Z-axis displacements, respectively.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA