RESUMEN
Reverberation in real environments is an important factor affecting the high resolution of target sound source localization (SSL) methods. Broadband low-frequency signals are common in real environments. This study focuses on the localization of this type of signal in reverberant environments. Because the time reversal (TR) method can overcome multipath effects and realize adaptive focusing, it is particularly suitable for SSL in a reverberant environment. On the basis of the significant advantages of the sparse Bayesian learning algorithm in the estimation of wave direction, a novel SSL is proposed in reverberant environments. First, the sound propagation model in a reverberant environment is studied and the TR focusing signal is obtained. We then use the sparse Bayesian framework to locate the broadband low-frequency sound source. To validate the effectiveness of the proposed method for broadband low-frequency targeting in a reverberant environment, simulations and real data experiments were performed. The localization performance under different bandwidths, different numbers of microphones, signal-to-noise ratios, reverberation times, and off-grid conditions was studied in the simulation experiments. The practical experiment was conducted in a reverberation chamber. Simulation and experimental results indicate that the proposed method can achieve satisfactory spatial resolution in reverberant environments and is robust.
RESUMEN
Obtaining real-world multi-channel speech recordings is expensive and time-consuming. Therefore, multi-channel recordings are often artificially generated by convolving existing monaural speech recordings with simulated Room Impulse Responses (RIRs) from a so-called shoebox room [1] for stationary (not moving) speakers. Far-field speech processing for home automation or smart assistants have to cope with moving speakers in reverberant environments. With this dataset, we aim to support the generation of realistic speech data by providing multiple directional RIRs along a fine grid of locations in a real room. We provide directional RIR recordings for a classroom and a large corridor. These RIRs can be used to simulate moving speakers by generating random trajectories on that grid, and quantize the trajectories along the grid points. For each matching grid point, the monaural speech recording can be convolved with the RIR at this grid point. Then, the spatialized recording can be compiled using the overlap-add method for each grid point [2]. An example is provided with the data.
RESUMEN
Estimating the elasticity of hydrogel phantoms in a cell culture plane is important for understanding the cell behavior in response to various types of mechanical stimuli. Hence, a noncontact tool for measuring the elastic properties of hydrogel phantoms in such three-dimensional cell cultures is required. A well-known method to determine the mechanical properties of hydrogels is the transient wave method. However, due to the multiple reflections of waves from the boundaries, a bigger cell culture plane or multiple directional filters may be required. In this study, we utilized reverberant shear wave elastography, which is based on the autocorrelation principle, to evaluate the shear wave speed in hydrogel samples within a culture dish. Numerical simulations were performed first to confirm the validity of the reverberant elastography method. Subsequently, we used this method to measure the wave speeds in hydrogel phantoms with different concentrations. Shear rheology tests were also performed, and their results were found to be in good agreement with the measured shear wave speeds. The proposed method could be useful for measuring the elasticity of tissues in tissue engineering applications in an inexpensive and noncontact manner.
Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hidrogeles , Fantasmas de Imagen , Hidrogeles/química , Diagnóstico por Imagen de Elasticidad/métodos , Elasticidad , Reología/métodosRESUMEN
Reverberant elastography provides fast and robust estimates of shear modulus; however, its reliance on multiple mechanical drivers hampers clinical utility. In this work, we hypothesize that for constrained organs such as the brain, reverberant elastography can produce accurate magnetic resonance elastograms with a single mechanical driver. To corroborate this hypothesis, we performed studies on healthy volunteers (n= 3); and a constrained calibrated brain phantom containing spherical inclusions with diameters ranging from 4-18 mm. In both studies (i.e. phantom and clinical), imaging was performed at frequencies of 50 and 70 Hz. We used the accuracy and contrast-to-noise ratio performance metrics to evaluate reverberant elastograms relative to those computed using the established subzone inversion method. Errors incurred in reverberant elastograms varied from 1.3% to 16.6% when imaging at 50 Hz and 3.1% and 16.8% when imaging at 70 Hz. In contrast, errors incurred in subzone elastograms ranged from 1.9% to 13% at 50 Hz and 3.6% to 14.9% at 70 Hz. The contrast-to-noise ratio of reverberant elastograms ranged from 63.1 to 73 dB compared to 65 to 66.2 dB for subzone elastograms. The average global brain shear modulus estimated from reverberant and subzone elastograms was 2.36 ± 0.07 kPa and 2.38 ± 0.11 kPa, respectively, when imaging at 50 Hz and 2.70 ± 0.20 kPa and 2.89 ± 0.60 kPa respectively, when imaging at 70 Hz. The results of this investigation demonstrate that reverberant elastography can produce accurate, high-quality elastograms of the brain with a single mechanical driver.
Asunto(s)
Diagnóstico por Imagen de Elasticidad , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Encéfalo/diagnóstico por imagen , Espectroscopía de Resonancia MagnéticaRESUMEN
Significance: Quantifying the biomechanical properties of the whole eye globe can provide a comprehensive understanding of the interactions among interconnected ocular components during dynamic physiological processes. By doing so, clinicians and researchers can gain valuable insights into the mechanisms underlying ocular diseases, such as glaucoma, and design interventions tailored to each patient's unique needs. Aim: The aim of this study was to evaluate the feasibility and effectiveness of a multifocal acoustic radiation force (ARF) based reverberant optical coherence elastography (RevOCE) technique for quantifying shear wave speeds in different ocular components simultaneously. Approach: We implemented a multifocal ARF technique to generate reverberant shear wave fields, which were then detected using phase-sensitive optical coherence tomography. A 3D-printed acoustic lens array was employed to manipulate a collimated ARF beam generated by an ultrasound transducer, producing multiple focused ARF beams on mouse eye globes ex vivo. RevOCE measurements were conducted using an excitation pulse train consisting of 10 cycles at 3 kHz, followed by data processing to produce a volumetric map of the shear wave speed. Results: The results show that the system can successfully generate reverberant shear wave fields in the eye globe, allowing for simultaneous estimation of shear wave speeds in various ocular components, including cornea, iris, lens, sclera, and retina. A comparative analysis revealed notable differences in wave speeds between different parts of the eye, for example, between the apical region of the cornea and the pupillary zone of the iris (p=0.003). Moreover, the study also revealed regional variations in the biomechanical properties of ocular components as evidenced by greater wave speeds near the apex of the cornea compared to its periphery. Conclusions: The study demonstrated the effectiveness of RevOCE based on a non-invasive multifocal ARF for assessing the biomechanical properties of the whole eyeball. The findings indicate the potential to provide a comprehensive understanding of the mechanical behavior of the whole eye, which could lead to improved diagnosis and treatment of ocular diseases.
Asunto(s)
Diagnóstico por Imagen de Elasticidad , Animales , Ratones , Cara , Córnea/diagnóstico por imagen , Iris , AcústicaRESUMEN
INTRODUCTION: The purpose of this study was to investigate the association between the mechanical properties of plantar soft tissue and diabetes status. METHOD: 51 (M/F: 21/30) participants with prediabetes onset (fasting blood sugar [FBS] level > 100 mg/dL), age >18 years, and no lower limb amputation were recruited after ethical approval was granted from Pontificia Universidad Catolica del Peru ethical review board. Ultrasound reverberant shear wave elastography was used to assess the soft tissue stiffness at the 1st metatarsal head (MTH), 3rd MTH, and the heel at both feet. RESULTS: Spearman's rank-order correlation (rho) test indicated a significant (P < .05) positive correlations between FBS level and the plantar soft tissue shear wave speed at the 1st MTH: rho = 0.402 (@400 Hz), rho = 0.373 (@450 Hz), rho = 0.474 (@500 Hz), rho= 0.395 (@550 Hz), and rho = 0.326 (@600 Hz) in the left foot and rho = 0.364 (@450 Hz) in the right foot. Mann-Whitney U test indicated a significantly (P < .05) higher shear wave speed in the plantar soft tissue with the following effect sizes (r) at the 1st MTH of the left foot at all tested frequencies: r = 0.297 (@450 Hz), r = 0.345 (@500 Hz), r = 0.322 (@550 Hz), and r = 0.275 (@600 Hz), and at the 1st MTH of right foot r = 0.286 (@400 Hz) in diabetes as compared with the age and body mass index matched prediabetes group. CONCLUSION: An association between fasting blood sugar level and the stiffness of the plantar soft tissue with higher values of shear wave speed in diabetes versus prediabetes group was observed. This indicated that the proposed approach can improve the assessment of the severity of diabetic foot complications with potential implications in patient stratification.
Asunto(s)
Diabetes Mellitus , Pie Diabético , Diagnóstico por Imagen de Elasticidad , Adolescente , Fenómenos Biomecánicos , Índice de Masa Corporal , Pie Diabético/diagnóstico por imagen , Pie/diagnóstico por imagen , HumanosRESUMEN
Plantar soft tissue stiffness provides relevant information on biomechanical characteristics of the foot. Therefore, appropriate monitoring of foot elasticity could be useful for diagnosis, treatment or health care of people with complex pathologies such as a diabetic foot. In this work, the reliability of reverberant shear wave elastography (RSWE) applied to plantar soft tissue was investigated. Shear wave speed (SWS) measurements were estimated at the plantar soft tissue at the first metatarsal head, the third metatarsal head and the heel from both feet in five healthy volunteers. Experiments were repeated for a test-retest analysis with and without the use of gel pad using a mechanical excitation frequency range between 400 and 600 Hz. Statistical analysis was performed to evaluate the reliability of the SWS estimations. In addition, the results were compared against those obtained with a commercially available shear wave-based elastography technique, supersonic imaging (SSI). The results indicate a low coefficient of variation for test-retest experiments with gel pad (median: 5.59%) and without gel pad (median: 5.83%). Additionally, the values of the SWS measurements increase at higher frequencies (median values: 2.11 m/s at 400 Hz, 2.16 m/s at 450 Hz, 2.24 m/s at 500 Hz, 2.21 m/s at 550 Hz and 2.31 m/s at 600 Hz), consistent with previous reports at lower frequencies. The SWSs at the plantar soft tissue at the first metatarsal head, third metatarsal head and heel were found be significantly (p<0.05) different, with median values of 2.42, 2.16 and 2.03 m/s, respectively which indicates the ability of the method to differentiate between shear wave speeds at different anatomical locations. The results indicated better elastographic signal-to-noise ratios with RSWE compared to SSI because of the artifacts presented in the SWS generation. These preliminary results indicate that the RSWE approach can be used to estimate the plantar soft tissue elasticity, which may have great potential to better evaluate changes in biomechanical characteristics of the foot.
Asunto(s)
Diagnóstico por Imagen de Elasticidad , Elasticidad , Pie/diagnóstico por imagen , Talón/diagnóstico por imagen , Humanos , Reproducibilidad de los ResultadosRESUMEN
As elastography of the brain finds increasing clinical applications, fundamental questions remain about baseline viscoelastic properties of the brainin vivo. Furthermore, the underlying mechanisms of how and why elastographic measures can change over time are still not well understood. To study these issues, reverberant shear wave elastography using an optical coherence tomography scanner is implemented on a mouse model, both under awake conditions and in a sleep state where there are known changes in the glymphatic fluid flow system in the brain. We find that shear wave speed, a measure of stiffness, changes by approximately 12% between the two states, sleep versus awake, in the entire cortical brain imaging volume. Our microchannel flow model of biphasic (fluid plus solid) tissue provides a plausible rheological model based on the fractal branching vascular and perivascular system, plus a second parallel system representing the finer scale glymphatic fluid microchannels. By adjusting the glymphatic system fluid volume proportional to the known sleep/wake changes, we are able to approximately predict the measured shear wave speeds and their change with the state of the glymphatic system. The advantages of this model are that its main parameters are derived from anatomical measures and are linked to other major derivations of branching fluid structures including Murray's Law. The implications for clinical studies are that elastography of the brain is strongly influenced by the regulation or dysregulation of the vascular, perivascular, and glymphatic systems.
Asunto(s)
Diagnóstico por Imagen de Elasticidad , Animales , Ratones , Diagnóstico por Imagen de Elasticidad/métodos , Encéfalo/diagnóstico por imagen , Vigilia , SueñoRESUMEN
The tendency over the last decades in the aerospace industry is to substitute classic metallic materials with new composite materials such as carbon fiber composites (CFC), fiber glass, etc., as well as adding electronic devices to ensure the safety and proper platform operation. Due to this, to protect the aircraft against the Electromagnetic Environmental Effects (E3), it is mandatory to develop accurate electromagnetic (EM) characterization measurement systems to analyze the behavior of new materials and electronic components. In this article, several measurement methods are described to assess the EM behavior of the samples under test: microstrip transmission line for a surface current analysis, free space to obtain intrinsic features of the materials and shielding effectiveness (SE) approaches to figure out how well they isolate from EM fields. The results presented in this work show how the different facilities from the National Institute of Aerospace Technology (INTA) are suitable for such purposes, being capable of measuring a wide variety of materials, depending on the type of test to be carried out.
RESUMEN
Elastography is a modality that estimates tissue stiffness and, thus, provides useful information for clinical diagnosis. Attention has focused on the measurement of shear wave propagation; however, many methods assume shear wave propagation is unidirectional and aligned with the lateral imaging direction. Any deviations from the assumed propagation result in biased estimates of shear wave speed. To address these challenges, directional filters have been applied to isolate shear waves with different propagation directions. Recently, a new method was proposed for tissue stiffness estimation involving creation of a reverberant shear wave field propagating in all directions within the medium. These reverberant conditions lead to simple solutions, facile implementation and rapid viscoelasticity estimation of local tissue. In this work, this new approach based on reverberant shear waves was evaluated and compared with another well-known elastography technique using two calibrated elastic and viscoelastic phantoms. Additionally, the clinical feasibility of this technique was analyzed by assessing shear wave speed in human liver and breast tissues, in vivo. The results indicate that it is possible to estimate the viscoelastic properties in each scanned medium. Moreover, a better approach to estimation of shear wave speed was obtained when only the phase information was taken from the reverberant waves, which is equivalent to setting all magnitudes within the bandpass equal to unity: an idealization of a perfectly isotropic reverberant shear wave field.
Asunto(s)
Mama/anatomía & histología , Diagnóstico por Imagen de Elasticidad/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Hígado/anatomía & histología , Fantasmas de Imagen , Estudios de Factibilidad , Femenino , Humanos , Valores de ReferenciaRESUMEN
OBJECTIVE: The purpose of this study was to explore the differences in speech intelligibility in short-reverberant sound fields using deteriorated monosyllables. Generated using digital signal processing, deteriorated monosyllables can lack the redundancy of words, and thus may emphasize differences in sound fields in terms of speech clarity. METHODS: Ten participants without any hearing disorders identified 100 monosyllables convolved with eight impulse responses measured in different short-reverberant sound fields (speech transmission index >0.6 and reverberation time <1s), and we compared speech recognition scores between normal and deteriorated monosyllables. Deterioration was produced using low-pass filtering (cut off frequency=1600Hz). RESULTS: Speech recognition scores associated with the deteriorated monosyllables were lower than those for the normal monosyllables. In addition, scores were more varied among the different sound fields, although this result was not significant according to an analysis of variance. In contrast, the variation among sound fields was significant for the normal monosyllables. When comparing the intelligibility scores to the acoustic parameters calculated from eight impulse responses, the speech recognition scores were the highest when the reverberant/direct sound energy ratio (R/D) was balanced. CONCLUSIONS: Although our deterioration procedure obscured differences in intelligibility score among the different sound fields, we have established that the R/D is a useful parameter for evaluating speech intelligibility in short-reverberant sound fields.
Asunto(s)
Inteligibilidad del Habla , Adulto , Femenino , Humanos , Masculino , Percepción del HablaRESUMEN
Localization of sound sources is a considerable computational challenge for the human brain. Whereas the visual system can process basic spatial information in parallel, the auditory system lacks a straightforward correspondence between external spatial locations and sensory receptive fields. Consequently, the question how different acoustic features supporting spatial hearing are represented in the central nervous system is still open. Functional neuroimaging studies in humans have provided evidence for a posterior auditory "where" pathway that encompasses non-primary auditory cortex areas, including the planum temporale (PT) and posterior superior temporal gyrus (STG), which are strongly activated by horizontal sound direction changes, distance changes, and movement. However, these areas are also activated by a wide variety of other stimulus features, posing a challenge for the interpretation that the underlying areas are purely spatial. This review discusses behavioral and neuroimaging studies on sound localization, and some of the competing models of representation of auditory space in humans. This article is part of a Special Issue entitled Human Auditory Neuroimaging.