Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Nano Lett ; 21(1): 833-839, 2021 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-33372510

RESUMEN

Graphene has been studied extensively for use in flexible electronics as ultrasensitive and wide-area strain sensors. Many sensors demonstrated so far rely on graphene networks, such that the spatial resolution is compromised, and they are unable to measure strain variations on a fine scale such as those resulting from substrate/interface failure. In this study, mono-/few-layer graphene are demonstrated to be good candidates for strain sensing with high spatial resolution to evaluate features <100 nm. The fundamentals of strain sensing-interaction with the target-have been discussed to shed light on the sensitivity and durability for future sensor fabrication. The proof-of-concept strain sensors have been shown to be able to monitor different states, e.g., the initiation and evolution, of crazes. The analysis also leads to the evaluation of interfacial energy and realization of high local strain in graphene that is applicable for other 2D materials for ultrasensitive strain sensing and bandgap opening applications.

2.
Sensors (Basel) ; 21(17)2021 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-34502793

RESUMEN

Due to the low costs of distributed optical fibre sensors (DFOS) and the possibility of their direct integration within layered composite members, DFOS technology has considerable potential in structural health monitoring of linear underground infrastructures. Often, it is challenging to truly simulate the actual ground conditions at all construction stages. Thus, reliable measurements are required to adjust the model and verify theoretical calculations. The article presents a new approach to monitor displacements and strains in Glass Fiber Reinforced Polymer (GFRP) collectors and pipelines using DFOS. The research verifies the effectiveness of the proposed monitoring solution for health monitoring of composite pipelines. Optical fibres were installed over the circumference of a composite tubular pipe, both on the internal and external surfaces, while loaded externally. Analysis of strain profiles allowed for calculating the actual displacements (shape) of the pipe within its cross-section plane using the Trapezoidal method. The accuracy of proposed approach was positively verified both with reference spot displacement transducer as well as numerical simulations using finite element method (FEM). DFOS could obtain a comprehensive view of structural deformations, including both strains and displacements under externally applied load. The knowledge gained during research will be ultimately used for renovating existing collectors.


Asunto(s)
Tecnología de Fibra Óptica , Fibras Ópticas , Polímeros , Transductores
3.
Res Vet Sci ; 178: 105378, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39137606

RESUMEN

The implantation of unicortical cortex screws in the proximal hole of locking compression plates (LCP) has been recommended for proximal interphalangeal (PIP) arthrodesis in horses to prevent fractures resulting from stress risers in the proximal phalanx (P1). However, this cortex screw fixation technique may limit efficient dorsal compression of the PIP joint by the plate, potentially affecting the stability of the construct. In this study, we aimed to measure stress and strain in P1 and the plate using an ex vivo model of PIP arthrodesis in horses. We employed various implantation methods and proximal screw types in conjunction with two 5.5 mm transarticular cortex screws. Ten pairs of equine forelimbs were divided into four groups based on proximal screw placement: GUC (unicortically placed cortex screw), GBC (bicortically placed cortex screw), GUL (unicortically placed locking screw), and GBL (bicortically placed locking screw). We calculated the magnitude and direction of strain, strain ratio, and stress using strain gauges during an axial compression mechanical testing. The palmar surface of P1 exhibited higher stress and strains than the dorsal surface, with the plate part located at the articular level suffered more stress than the proximal part. Both the implantation method and proximal screw type significantly influenced the analyzed parameters. The GUC promoted greater changes in strain direction in the proximal portion of the P1. Bicortical placement of a cortex screw appears to be the most suitable option for filling the proximal hole of the LCP, because it allows effective dynamic compression via the plate and prevents abrupt shifts in the direction of the forces acting on the proximal part of P1 during loading.


Asunto(s)
Artrodesis , Placas Óseas , Tornillos Óseos , Estrés Mecánico , Animales , Caballos , Artrodesis/veterinaria , Artrodesis/instrumentación , Artrodesis/métodos , Placas Óseas/veterinaria , Fenómenos Biomecánicos , Miembro Anterior/cirugía , Cadáver
4.
Materials (Basel) ; 17(10)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38793419

RESUMEN

Additive manufacturing enables the production of lattice structures, which have been proven to be a superior class of lightweight mechanical metamaterials whose specific stiffness can reach the theoretical limit of the upper Hashin-Shtrikman bound for isotropic cellular materials. To achieve isotropy, complex structures are required, which can be challenging in powder bed additive manufacturing, especially with regard to subsequent powder removal. The present study focuses on the Finite Element Method simulation of 2.5D anisotropic plate lattice metamaterials and the investigation of their lightweight potential. The intentional use of anisotropic structures allows the production of a cell architecture that is easily manufacturable via Laser Powder Bed Fusion (LPBF) while also enabling straightforward optimization for specific load cases. The work demonstrates that the considered anisotropic plate lattices exhibit high weight-specific stiffnesses, superior to those of honeycomb structures, and, simultaneously, a good de-powdering capability. A significant increase in stiffness and the associated surpassing of the upper Hashin-Shtrikman bound due to anisotropy is achievable by optimizing wall thicknesses depending on specific load cases. A stability analysis reveals that, in all lattice structures, plastic deformation is initiated before linear buckling occurs. An analysis of stress concentrations indicates that the introduction of radii at the plate intersections reduces stress peaks and simultaneously increases the weight-specific stiffnesses and thus the lightweight potential. Exemplary samples illustrate the feasibility of manufacturing the analyzed metamaterials within the LPBF process.

5.
Materials (Basel) ; 16(2)2023 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-36676510

RESUMEN

Whereas mechanics theories for isotropic materials are almost matured, only linear elastic theories for composites were essentially established. This is because only homogenized or approximated stresses are obtainable for a composite. Its mechanical properties must be estimated on a true stress level. According to Eshelby, the true stresses of the fiber are the same as its homogenized counterparts. The true stress theory for the matrix was systematically established by the author, and is reviewed and summarized in the paper. An Excel table-based program for calculating all of the possible true stress components is provided as a supplement for the reader to download. As most composite failures are caused by matrix failures, the true stress theory plays a predominant role in estimating the composite properties outside a linear elastic range. Some challenging composite failures were resolved upon the matrix true stresses, and are highlighted in the paper.

6.
Mech Mater ; 442012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24285911

RESUMEN

The attachment of tendon to bone, one of the greatest interfacial material mismatches in nature, presents an anomaly from the perspective of interfacial engineering. Deleterious stress concentrations arising at bi-material interfaces can be reduced in engineering practice by smooth interpolation of composition, microstructure, and mechanical properties. However, following normal development, the rotator cuff tendon-to-bone "insertion site" presents an interfacial zone that is more compliant than either tendon or bone. This compliant zone is not regenerated following healing, and its absence may account for the poor outcomes observed following both natural and post-surgical healing of insertion sites such as those at the rotator cuff of the shoulder. Here, we present results of numerical simulations which provide a rationale for such a seemingly illogical yet effective interfacial system. Through numerical optimization of a mathematical model of an insertion site, we show that stress concentrations can be reduced by a biomimetic grading of material properties. Our results suggest a new approach to functional grading for minimization of stress concentrations at interfaces.

7.
Data Brief ; 39: 107590, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34877374

RESUMEN

We performed in-situ tensile tests on two carbon fibre/epoxy composites with continuous scanning using synchrotron computed tomography (CT). Both composites were cross-ply laminates, and two specimens were tested for each composite. The voxel size was sufficiently small to recognize individual fibres and fibre breaks. For each test, 16-19 volumes were reconstructed, cropped down to the 0° plies and analysed to track fibre break and cluster development. This dataset provides the last CT volume before failure for each of the four specimens as well as the individual fibre break locations in all reconstructed volumes. These data are then plotted against predictions from six state-of-the-art strength models. The target is that these data become a benchmark for the development of new models, inspiring researchers to set up refined experiments and develop improved models.

8.
Bone ; 143: 115647, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32956853

RESUMEN

The fatigue life of cortical bone can vary several orders of magnitude, even in identical loading conditions. A portion of this variability is likely related to intracortical microarchitecture and the role of vascular canals as stress concentrators. The size, spatial distribution, and density of canals determine the peak magnitude and volume of stress concentrations. This study utilized a combination of experimental fatigue testing and image-based finite element (FE) analysis to establish the relationship between the stressed volume (i.e., volume of bone above yield stress) associated with vascular canals and the fatigue life of cortical bone. Thirty-six cortical bone samples were prepared from human femora and tibiae from five donors. Samples were allocated to four loading groups, corresponding to stress ranges of 60, 70, 80, and 90 MPa, then cyclically loaded in zero-compression until fracture. Porosity, canal diameter, canal separation, and canal number for each sample was quantified using X-ray microscopy (XRM) after testing. FE models were created from XRM images and used to calculate the stressed volume. Stressed volume was a good predictor of fatigue life, accounting for 67% of the scatter in fatigue-life measurements. An increase in stressed volume was most strongly associated with higher levels of intracortical porosity and larger canal diameters. The findings from this study suggest that a large portion of the fatigue-life variance of cortical bone in zero-compression is driven by intracortical microarchitecture, and that fatigue failure may be predicted by quantifying the stress concentrations associated with vascular canals.


Asunto(s)
Huesos , Hueso Cortical , Hueso Cortical/diagnóstico por imagen , Fémur , Análisis de Elementos Finitos , Humanos , Porosidad , Estrés Mecánico
9.
Front Physiol ; 11: 388, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32670073

RESUMEN

In the acute respiratory distress syndrome (ARDS), surface tension, T, is likely elevated. And mechanical ventilation of ARDS patients causes ventilation-induced lung injury (VILI), which is believed to be proportional to T. However, the mechanisms through which elevated T may contribute to VILI have been under-studied. This conceptual analysis considers experimental and theoretical evidence for static and dynamic mechanical mechanisms, at the alveolar scale, through which elevated T exacerbates VILI; potential causes of elevated T in ARDS; and T-dependent means of reducing VILI. In the last section, possible means of reducing T and improving the efficacy of recruitment maneuvers during mechanical ventilation of ARDS patients are discussed.

10.
Materials (Basel) ; 12(20)2019 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-31640231

RESUMEN

To investigate the relationship between inclusions and bending fatigue behaviors in 20Cr2Ni4 steel under different stress concentrations. This paper designs a new experimental method to prefabricate different size stress concentrations near the inclusions, and then conducts a new type of bending fatigue test to study the inclusions and their surrounding stress distributions in 20Cr2Ni4 steel. A microhardness tester was combined with laser etching equipment to realize the prefabrication of different stress concentrations at arbitrary positions around any inclusion on the gear steel surface. This method provides an experimental basis for the quantitative analysis of the relationship between stress distribution and fatigue life around the inclusions of heavy-duty gear steels. We also predict the bending fatigue lives of heavy-duty gear steels with different types of inclusions, stress states, and spatial distributions. Then, based on the prefabricated notch parameters and the state of inclusions in the steel, a mathematical model of quantitative analysis is proposed, which can accurately predict the fatigue limit of heavy-duty gear steel. The research results can be applied to the actual use of heavy-duty gears and to the accurate life estimation based on the state of gear stress, thereby providing a quantitative reference model for subsequent gear steel production and gear part processing.

11.
ACS Appl Mater Interfaces ; 8(13): 8789-800, 2016 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-26953827

RESUMEN

The effects of ice formation and accretion on external surfaces range from being mildly annoying to potentially life-threatening. Ice-shedding materials, which lower the adhesion strength of ice to its surface, have recently received renewed research attention as a means to circumvent the problem of icing. In this work, we investigate how surface wettability and surface topography influence the ice adhesion strength on three different surfaces: (i) superhydrophobic laser-inscribed square pillars on copper, (ii) stainless steel 316 Dutch-weave meshes, and (iii) multiwalled carbon nanotube-covered steel meshes. The finest stainless steel mesh displayed the best performance with a 93% decrease in ice adhesion relative to polished stainless steel, while the superhydrophobic square pillars exhibited an increase in ice adhesion by up to 67% relative to polished copper. Comparisons of dynamic contact angles revealed little correlation between surface wettability and ice adhesion. On the other hand, by considering the ice formation process and the fracture mechanics at the ice-substrate interface, we found that two competing mechanisms governing ice adhesion strength arise on nonplanar surfaces: (i) mechanical interlocking of the ice within the surface features that enhances adhesion, and (ii) formation of microcracks that act as interfacial stress concentrators, which reduce adhesion. Our analysis provides insight toward new approaches for the design of ice-releasing materials through the use of surface topographies that promote interfacial crack propagation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA