Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 800
Filtrar
Más filtros

País/Región como asunto
Intervalo de año de publicación
1.
Small ; : e2402583, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38804883

RESUMEN

The introduction of axial-coordinated heteroatoms in Fe─N─C single-atom catalysts enables the significant enhancement of their oxygen reduction reaction (ORR) performance. However, the interaction relationship between the axial-coordinated heteroatoms and their carbon supports is still unclear. In this work, a gas phase surface treatment method is proposed to prepare a series of X─Fe─N─C (X = O, P, and S) single-atom catalysts with axial X-coordination on graphitic-N-rich carbon supports. Synchrotron-based X-ray absorption near-edge structure spectra and X-ray photoelectron spectroscopy indicate the formation of an axial charge transfer channel between the graphitic-N-rich carbon supports and single-atom Fe sites by axial O atoms in O─Fe─N─C. As a result, the O─Fe─N─C exhibits excellent ORR performance with a half-wave potential of 0.905 V versus RHE and a high specific capacity of 884 mAh g-1 for zinc-air battery, which is superior to other X─Fe─N─C catalysts without axial charge transfer and the commercial Pt/C catalyst. This work not only demonstrates a general synthesis strategy for the preparation of single-atom catalysts with axial-coordinated heteroatoms, but also presents insights into the interaction between single-atom active sites and doped carbon supports.

2.
Biotechnol Bioeng ; 121(6): 1950-1960, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38470332

RESUMEN

In developing three-dimensional (3D) human skin equivalents (HSEs), preventing dermis and epidermis layer distortion due to the contraction of hydrogels by fibroblasts is a challenging issue. Previously, a fabrication method of HSEs was tested using a modified solid scaffold or a hydrogel matrix in combination with the natural polymer coated onto the tissue culture surface, but the obtained HSEs exhibited skin layer contraction and loss of the skin integrity and barrier functions. In this study, we investigated the method of HSE fabrication that enhances the stability of the skin model by using surface plasma treatment. The results showed that plasma treatment of the tissue culture surface prevented dermal layer shrinkage of HSEs, in contrast to the HSE fabrication using fibronectin coating. The HSEs from plasma-treated surface showed significantly higher transepithelial electrical resistance compared to the fibronectin-coated model. They also expressed markers of epidermal differentiation (keratin 10, keratin 14 and loricrin), epidermal tight junctions (claudin 1 and zonula occludens-1), and extracellular matrix proteins (collagen IV), and exhibited morphological characteristics of the primary human skins. Taken together, the use of plasma surface treatment significantly improves the stability of 3D HSEs with well-defined dermis and epidermis layers and enhanced skin integrity and the barrier functions.


Asunto(s)
Piel Artificial , Humanos , Gases em Plasma/química , Gases em Plasma/farmacología , Ingeniería de Tejidos/métodos , Piel/química
3.
Ophthalmic Physiol Opt ; 44(4): 769-773, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38404141

RESUMEN

INTRODUCTION: Midday fogging is a complication of scleral lens (SL) wear that interrupts clear vision during the course of wear. SLs can be made with a variety of gas permeable materials, sizes and surface treatments, and various solutions are available for storing the lenses and for filling them before application on the eye. Many of these factors have been implicated as possible contributors to midday fogging. This study explored the lens and solution properties in habitual SL wearers with and without midday fogging. METHODS: In this prospective study, 48 habitual SL wearers were evaluated and asked to report whether they experienced midday fogging and if they removed their lenses during the day. They completed the Ocular Surface Disease Index (OSDI), which is a validated tool for dry eye assessment. Lens parameters (material, coatings and diameter) and lens storage and filling solutions were documented. Backward elimination of regression terms evaluated the lens and solution properties in those with and without fogging. OSDI scores were compared using the Mann-Whitney analysis. RESULTS: Collectively, the lens properties and solutions accounted for 27.7% of the variance related to midday fogging. None of the factors alone had a significant impact upon midday fogging. The median (interquartile range) OSDI score for those with fogging [37 (35)] was significantly different from those without fogging [10 (15)], with the scores corresponding to severe dry eye and normal eyes, respectively. CONCLUSION: SL wearers with midday fogging exhibited similar symptoms to patients with severe dry eye. Lens and solution characteristics may play a small role in patients with midday fogging, although changing just a single factor is not likely to impact its presence.


Asunto(s)
Síndromes de Ojo Seco , Humanos , Masculino , Femenino , Estudios Prospectivos , Adulto , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/fisiopatología , Síndromes de Ojo Seco/diagnóstico , Adulto Joven , Persona de Mediana Edad , Soluciones para Lentes de Contacto , Lentes de Contacto/efectos adversos , Esclerótica
4.
Clin Oral Investig ; 28(2): 128, 2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38294555

RESUMEN

OBJECTIVES: This in vitro study aimed to evaluate the wear of natural teeth opposing 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) with different surface conditions. MATERIALS AND METHODS: Sixty 3Y-TZP specimens were randomly assigned to six groups (n = 10), differing in surface condition. In three groups, the samples underwent glazing-with the glaze applied to roughened (i.e., 106-µm-grit diamond-finished), as-sintered, and polished zirconia. The three remaining groups consisted of unglazed specimens: solely polished samples and diamond-finished samples (106-µm-grit and 46-µm-grit) without further conditioning. Two-body wear was evaluated at extracted, non-carious molars (n = 60), which served as antagonists in chewing simulation (10,000 masticatory cycles, 49N load). As a control, natural teeth with intact enamel surfaces were tested against natural molars (n = 10). All samples were 3D-scanned before and after the chewing simulation (7 Series, Straumann). Volume loss was calculated (Inspect Software, GOM), and statistically analyzed (SPSS Statistics 24, IBM). RESULTS: Volume loss of the natural antagonists decreased in the following order: 106-µm-grit diamond-finished zirconia (4.6 ± 2.5 mm3), glazed 106-µm-grit diamond-finished zirconia (3.8 ± 1.1 mm3), glazed as-sintered zirconia (3.5 ± 0.9 mm3), 46-µm-grit diamond-finished zirconia (1.7 ± 0.6 mm3), control (1.6 ± 0.7 mm3), glazed polished zirconia (1.4 ± 0.5 mm3), and solely polishing (0.4 ± 0.2 mm3). Even when polishing the surfaces before glazing, volume loss was not mitigated to the same extent as after polishing alone. CONCLUSIONS: The zirconia surface condition beneath the glazing influences antagonist wear. Although polishing before glazing resulted in acceptable levels of antagonist wear, this approach did not yield as favorable results as polishing alone. CLINICAL RELEVANCE: For operators favoring glazing, pre-polishing the zirconia surface could be advantageous to reduce wear.


Asunto(s)
Esmalte Dental , Boca Edéntula , Circonio , Humanos , Simulación por Computador , Diamante , Masticación
5.
Clin Oral Investig ; 28(9): 473, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39110133

RESUMEN

PURPOSE: To investigate the effects of different surface treatments and thicknesses on the color, transparency, and surface roughness of ultra-transparent zirconia. METHODS: A total of 120 Katana ultra-translucent multi-layered zirconia specimens were divided into 12 groups according to the thickness (0.3, 0.5, and 0.7 mm) and surface treatment (control, airborne particle abrasion [APA], lithium disilicate coating, and glaze on). Color difference (ΔE00) and relative translucency parameter (RTP00) were calculated using a digital spectrophotometer. The surface roughness (Ra, Rq, Sa, and Sq) was measured using a non-contact profile scanner. The surface morphologies and microstructures of the samples were observed using a tungsten filament scanning electron microscope. Statistical analyses were performed by one-way and two-way analysis of variance (ANOVA) followed by post hoc multiple comparisons and Pearson's correlation (α = 0.05). RESULTS: The results showed that the surface treatment, ceramic thickness, and their interactions had significant effects on ΔE00 and RTP00 (p < 0.001). The surface treatment significantly altered the micromorphology and increased the surface roughness of the ceramic samples. APA exhibited the lowest transparency, largest color difference, and highest surface roughness. Zirconia with 0.3 mm and 0.7 mm thicknesses showed strong negative correlations between Sa and RTP00. CONCLUSIONS: The three internal surface treatments significantly altered the surface roughness, color difference, and transparency of ultra-transparent zirconia. As the thickness increased, the influence of the inner surface treatment on the color difference and transparency of zirconia decreased. CLINICAL IMPLICATIONS: For new zirconia internal surface treatment technologies, in addition to considering the enhancement effect on the bonding properties, the potential effects on the color and translucency of high-transparency zirconia should also be considered. Appropriately increasing the thickness of zirconia restorations helps minimize the effect of surface treatment on the optical properties.


Asunto(s)
Color , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Espectrofotometría , Propiedades de Superficie , Circonio , Circonio/química , Porcelana Dental/química , Materiales Dentales/química , Recubrimiento Dental Adhesivo/métodos
6.
Nano Lett ; 23(3): 1061-1067, 2023 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-36662173

RESUMEN

Thin films of ZnO nanocrystals are actively pursued as electron-transporting layers (ETLs) in quantum-dot light-emitting diodes (QLEDs). However, the developments of ZnO-based ETLs are highly engineering oriented and the design of ZnO-based ETLs remains empirical. Here, we identified a previously overlooked efficiency-loss channel associated with the ZnO-based ETLs: i.e., interfacial exciton quenching induced by surface-bound ethanol. Accordingly, we developed a general surface-treatment procedure to replace the redox-active surface-bound ethanol with electrochemically inert alkali carboxylates. Characterization results show that the surface treatment procedure does not change other key properties of the ETLs, such as the conductance and work function. Our single-variable experimental design unambiguously demonstrates that improving the electrochemical stabilities of the ZnO ETLs leads to QLEDs with a higher efficiency and longer operational lifetime. Our work provides a crucial guideline to design ZnO-based ETLs for optoelectronic devices.

7.
Odontology ; 112(1): 74-82, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37036616

RESUMEN

Because the use of hydrofluoric acid (HF) poses health risks if handled improperly, many clinicians prefer to have the ceramic restorations pre-etched in dental laboratories. However, during the try-in procedure, the pre-etched glass-ceramic restorations may be contaminated with saliva resulting in reduced bond strength. This in-vitro study aimed to investigate the effect of different surface treatments on the bond strength of lithium disilicate (LD) glass-ceramic restorations (IPS e.max Press, Ivoclar Vivadent) to two resin cements. One-hundred eighty blocks (4X4X3mm) of LD glass-ceramic were divided into twelve groups (n = 15), of which six received Variolink Esthetic DC (VE) cement and six received RelyX Ultimate (RU) cement, following the surface treatments: G1) Control: Hydrofluoric Acid + Silane (HF + Sil); G2) Hydrofluoric Acid + Saliva + Silane (HF + S + Sil); G3) Hydrofluoric Acid + Saliva + Ivoclean + Silane (HF + S + IC + Sil); G4) Hydrofluoric Acid + Saliva + Phosphoric Acid + Silane (HF + S + P + Sil); G5) Hydrofluoric Acid + Saliva + Monobond Etch & Prime (HF + S + EP); G6) Monobond Etch & Prime (EP). Following treatment, a resin-cement cylinder (2.3 mm diameter) was built on the glass-ceramic surface, photocured (20 s), stored in distilled water (37 °C, 24 h) and submitted to the shear bond strength test. Bond strength data (MPa) were subjected to two-way ANOVA and Tukey (α = 0.01). Cement type and surface treatment had a significant effect on the bond strength (p < 0.001) (Table 4). Single-step Monobond Etch & Prime (EP) significantly improved the bond strength of resin-cements to glass-ceramic with and without saliva contamination.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Cementos de Resina/química , Ácido Fluorhídrico , Silanos , Propiedades de Superficie , Porcelana Dental , Cerámica , Cementos Dentales , Protocolos Clínicos , Ensayo de Materiales
8.
Molecules ; 29(9)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38731440

RESUMEN

Microdroplet-based fluidic systems have the advantages of small size, short diffusion time, and no cross-contamination; consequently, droplets often provide a fast and precise reaction environment as well as an analytical environment for individual molecules. In order to handle diverse reactions, we developed a method to create organic single-micron droplets (S-MDs) smaller than 5 µm in diameter dispersed in silicone oil without surfactant. The S-MD generation microflow device consists of a mother droplet (MoD) generator and a tapered separation channel featuring multiple side channels. The tapered channel enhanced the shear forces to form tails from the MoDs, causing them to break up. Surface treatment with the fluoropolymer CYTOP protected PDMS fluid devices from organic fluids. The tailing separation of methanol droplets was accomplished without the use of surfactants. The generation of tiny organic droplets may offer new insights into chemical separation and help study the scaling effects of various chemical reactions.

9.
BMC Oral Health ; 24(1): 513, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38698366

RESUMEN

BACKGROUND: This study aims to evaluate the effect of surface treatment and resin cement on the shear bond strength (SBS) and mode of failure of polyetheretherketone (PEEK) to lithium disilicate ceramic (LDC). This is suggested to study alternative veneering of PEEK frameworks with a ceramic material. METHODS: eighty discs were prepared from PEEK blank and from lithium disilicate ceramic. Samples were divided into four groups according to surface treatment: Group (A) air abraded with 110 µm Al2O3, Group (AP) air abrasion and primer application, Group (S) 98% sulfuric acid etching for 60 s, Group (SP) Sulfuric acid and primer. Each group was subdivided into two subgroups based on resin cement type used for bonding LDC:1) subgroup (L) self- adhesive resin cement and 2) subgroup (B) conventional resin cement (n = 10). Thermocycling was done for all samples. The bond strength was assessed using the shear bond strength test (SBS). Failure mode analysis was done at 50X magnification with a stereomicroscope. Samples were chosen from each group for scanning electron microscope (SEM). The three-way nested ANOVA followed by Tukey's post hoc test were used for statistical analysis of results. Comparisons of effects were done utilizing one way ANOVA and (p < 0.05). RESULTS: The highest mean of shear bond strength values was demonstrated in Group of air abrasion with primer application using conventional resin cement (APB) (12.21 ± 2.14 MPa). Sulfuric acid groups showed lower shear bond strength values and the majority failed in thermocycling especially when no primer was applied. The failure mode analysis showed that the predominant failure type was adhesive failure between cement and PEEK, while the remaining was mixed failure between cement and PEEK. CONCLUSION: The air abrasion followed by primer application and conventional resin cement used for bonding Lithium Disilicate to PEEK achieved the best bond strength. Primer application did not have an effect when self-adhesive resin cement was used in air-abraded groups. Priming step is mandatory whenever sulfuric acid etching surface treatment is utilized for PEEK.


Asunto(s)
Benzofenonas , Recubrimiento Dental Adhesivo , Porcelana Dental , Análisis del Estrés Dental , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Cementos de Resina , Resistencia al Corte , Propiedades de Superficie , Recubrimiento Dental Adhesivo/métodos , Grabado Ácido Dental/métodos , Ácidos Sulfúricos , Cerámica/química , Abrasión Dental por Aire/métodos , Óxido de Aluminio , Coronas con Frente Estético , Grabado Dental/métodos , Humanos
10.
BMC Oral Health ; 24(1): 558, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38741081

RESUMEN

BACKGROUND: We investigated the efficacy of two different cold atmospheric pressure jet plasma devices (CAP09 and CAPmed) and an air polishing device with glycine powder (AP) either applied as monotherapies or combined therapies (AP + CAP09; AP + CAPmed), in microbial biofilm removal from discs with anodised titanium surface. METHODS: Discs covered with 7-day-old microbial biofilm were treated either with CAP09, CAPmed, AP, AP + CAP09 or AP + CAPmed and compared with negative and positive controls. Biofilm removal was assessed with flourescence and electron microscopy immediately after treatment and after 5 days of reincubation of the treated discs. RESULTS: Treatment with CAP09 or CAPmed did not lead to an effective biofilm removal, whereas treatment with AP detached the complete biofilm, which however regrew to baseline magnitude after 5 days of reincubation. Both combination therapies (AP + CAP09 and AP + CAPmed) achieved a complete biofilm removal immediately after cleaning. However, biofilm regrew after 5 days on 50% of the discs treated with the combination therapy. CONCLUSION: AP treatment alone can remove gross biofilm immediately from anodised titanium surfaces. However, it did not impede regrowth after 5 days, because microorganisms were probably hidden in holes and troughs, from which they could regrow, and which were inaccessible to AP. The combination of AP and plasma treatment probably removed or inactivated microorganisms also from these hard to access spots. These results were independent of the choice of plasma device.


Asunto(s)
Biopelículas , Implantes Dentales , Gases em Plasma , Propiedades de Superficie , Titanio , Biopelículas/efectos de los fármacos , Titanio/química , Implantes Dentales/microbiología , Pulido Dental/métodos , Glicina , Humanos , Técnicas In Vitro , Microscopía Electrónica de Rastreo , Níquel
11.
J Prosthodont ; 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39189693

RESUMEN

PURPOSE: To evaluate the effect of different surface treatments and adhesive cementation on the miniflexural strength (MFS) of monolithic zirconia. MATERIALS AND METHODS: Two-hundred and forty (240) sintered bars of translucent zirconia (ZT) and ultra-translucent zirconia (ZUT) were obtained (8 mm ×2 mm ×1 mm). The bars were divided into 16 groups (n = 15) according to the factors "Zirconia" (ZT and ZUT), "Cementation" (Cem) and "surface treatment" (Ctrl:Control, Al:Aluminum oxide/Al2O3 50 µm, Si:Silica/SiO2 coated alumina particles oxide 30 µm, Gl:Glazing+hydrofluoric acid). Half of the bars received an adhesive layer application, followed by application of resin cement and light curing. The surface roughness was measured in non-cemented groups. All the bars were subjected to the MFS test (1.0 mm/min; 100 kgf). Scanning electron microscopy was used for qualitative analyses. MFS data (MPa) and roughness (µm) were statistically evaluated by three-way and two-way ANOVA respectively and Tukey's test (5%). RESULTS: The surface treatment and the interaction were significant for roughness. Glazing promoted less roughness compared to silicatization. Regarding MFS, only the zirconia and surface treatment factors were significant. For ZT, the sandblasted groups had an increase in MFS and glazing reduced it. There was no difference between the groups without cementation for the ZUT; however, ZUT.Si/Cem, and ZUT.Al/Cem obtained superior MFS among the cemented groups. CONCLUSIONS: Sandblasting increases the flexural strength for ZT, while glaze application tends to reduce it. Applying resin cement increases the flexural strength of ZUT when associated with sandblasting. Sandblasting protocols promote greater surface roughness.

12.
J Prosthodont ; 33(S1): 60-69, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38594924

RESUMEN

PURPOSE: Bioceramic coatings have been shown to promote bone repair, which aids in the early integration of implants. This study aimed to evaluate the influence of air abrasion with a bioceramic abrasive on the surface characteristics of different implant materials and surfaces. The dissolution of the applied treatment from the surfaces over 3 weeks was also assessed. MATERIALS AND METHODS: Discs of three alloys used for dental implants were studied and compared: two types of commercially pure titanium (CpTi)/ (CpTi SLActive) and titanium-zirconia (TiZr). The tested surfaces were: CpTi control (CpC), sandblasted (SB), sandblasted and acid-etched (SBE), and CpTi SLActive®, (TiZr) Roxolid®. Three discs from each group underwent air abrasion with apatite bioceramic powders, 95% hydroxyapatite (HA)/5% calcium oxide (CaO), and 90% hydroxyapatite (HA)/10% calcium oxide (CaO). The treated discs were surface characterized by optical profilometry to obtain surface roughness, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS) to compare element weight percentages of titanium, calcium, and phosphate. Dissolution was assessed using inductively coupled plasma optic emission spectrometry (ICP-OES). RESULTS: Bioceramic powders were deposited on all tested surfaces leading to changes in surface characteristics. The only statistically significant differences between the material groups for surface roughness were found with 95% HA/5% CaO powder in the Sp and Rp parameters (p = 0.03 and 0.04, respectively). There were no significant differences in the Ca and P wt% between all groups and powders 95% HA/5% CaO and 90% HA/10% CaO (p = 0.14, 0.18, and p = 0.15, 0.12, respectively). A non-uniform dispersion of the treatment on the surface layer was visible on all treated surfaces. The bioceramic powder continued to dissolute from the tested surfaces for 3 weeks. CONCLUSION: Bioceramic abrasion modifies implant surface characteristics, although the change in surface characteristics resulting from such treatment was not influenced by the implant material or surface treatment. Air abrasion with hydroxyapatite and calcium oxide bioceramics leaves powder deposits on the treated implant surfaces that could potentially influence the healing of implants affected by peri-implantitis.


Asunto(s)
Cerámica , Implantes Dentales , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Titanio , Circonio , Titanio/química , Circonio/química , Cerámica/química , Abrasión Dental por Aire , Ensayo de Materiales , Espectrometría por Rayos X , Polvos , Durapatita/química , Materiales Biocompatibles Revestidos/química , Materiales Dentales/química , Grabado Dental/métodos , Humanos
13.
J Prosthodont ; 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38858801

RESUMEN

PURPOSE: To evaluate the effect of mechanical, chemical, and mechanical-chemical surface treatment methods on shear bond strength between acrylic denture teeth and thermoplastic nylon denture base. MATERIALS AND METHODS: Maxillary central incisor teeth were treated with five different surface treatment methods: mechanical (sandblasting, T-shape diatoric holes), chemical (5% acetic acid solution, bonding agent), and mechanical-chemical (sandblasting + bonding agent) were embedded in thermoplastic nylon denture base (n = 10). A universal testing machine with a crosshead speed of 0.5 mm per minute was used to test the shear bond strength. Data obtained were statistically evaluated using one-way ANOVA and followed with Tukey post hoc test (α = 0.05) RESULTS: T-shaped diatoric holes exhibited significantly higher shear bond strength among the surface treatment groups, followed by sandblasting + bonding agent, sandblasting, bonding agent, and the acetic acid group (p < 0.001) CONCLUSION: T-shaped diatoric holes as a mechanical surface treatment showed higher shear bond strength than other methods.

14.
J Prosthodont ; 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39188160

RESUMEN

PURPOSE: The aim of the study was to investigate the effect of surface treatment and repair materials on the flexural strength of repaired 3D-printed denture base resins after thermal aging. MATERIALS AND METHODS: Bar-shape specimens (64 × 10 × 3.3 mm) were designed as intact (control) specimens while repair specimens were printed in sections with 2.5 mm space for repair material. Printing was performed with either ASIGA or NextDent denture base material. In each material, one group received no surface treatment, while other repair groups were subjected to one of three surface treatments: (1) monomer application, (2) aluminium oxide particles-abrasion, or (3) both methods (aluminum oxide particles-abrasion and monomer application). Pairs were fixed in a customized mold then repaired with either autopolymerizing acrylic resin or flowable composite (n = 9). Repaired specimens were incubated for 48 h at 37°C in distilled water and then subjected to thermal cycling (5000 cycles). A 3-point bending test was used to evaluate the flexural strength using a universal testing machine, and mode of failure determined followed by fractured surface analysis using scanning electron microscope. Data were analyzed using ANOVA and post hoc Tukey test (α = 0.05). RESULTS: Both resin materials showed a significant decrease in the flexural strength of repaired specimens when compared to control ones (p < 0.001). Groups with no surface treatment had significantly lower flexural strength than those with surface treatment (p < 0.001). Groups treated with monomer application, and with aluminum oxide particles abrasion plus monomer application had similar flexural strength values (p > 0.05), which were higher than those treated with aluminum oxide particles abrasion alone (p < 0.001). Specimens repaired with composite resin showed higher flexural strength than those repaired with auto-polymerized resin (p < 0.05) however, specimens treated with aluminum oxide particles abrasion alone had similar values for both repair materials (p = 0.95). Adhesive failure was dominant in all repaired groups with auto-polymerized while cohesive and mixed were dominant with composite repair groups. CONCLUSION: Surface treatment improved the repair strength of 3D-printed denture base resins. Using composite resin for repair shows better strength with dominant cohesive and mixed failure suggesting that surface treatment and composite repair are suitable procedures for 3D-printed denture base repair.

15.
J Prosthodont ; 2024 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-39305504

RESUMEN

PURPOSE: To investigate the effects of different surface treatments and thermal cycling on the shear bond strength between 3D-printed teeth and denture bases. MATERIAL AND METHODS: For the shear bond strength (SBS) test, the specimens were the maxillary central incisors (11 × 9 × 7 mm) bonded on a cylindrical base (20 × 25 mm). The control group was heat-cured polymethylmethacrylate (PMMA) (N = 20). The printed group was divided into five subgroups (N = 20): no treatment, sandblasting with aluminum oxide (Al2O3), methyl methacrylate monomer, acetone, and adhesive with urethane dimethacrylate. Half of the samples were subjected to 2000 thermal cycling cycles, and all samples were subjected to the SBS test. The failure mode was established as adhesive, cohesive, or mixed through stereomicroscopic analysis. The surface roughness test (Sa) was performed using optical profilometry, and the rectangular specimens (14 × 14 × 2.5 mm) were divided into four groups according to the surface treatments (N = 7 per group). Paired T and Wilcoxon tests were conducted to perform comparisons within the same group. The Kruskal-Wallis and Dwass-Steel-Critchlow-Fligner post-hoc tests were conducted to compare the groups. RESULTS: Al2O3 sandblasting in the 3D-printed groups achieved high SBS values comparable to those of the control group in the thermal cycled (p = 0.962) and non-thermal cycled samples (p = 0.319). It was the only treatment capable of modifying the surface of the 3D-printed resin, thereby increasing the roughness (p = 0.016). CONCLUSIONS: Sandblasting is recommended to increase the bond strength between the tooth and denture bases.

16.
J Contemp Dent Pract ; 25(3): 276-279, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38690702

RESUMEN

AIM: The current study was carried out to assess the interaction between fibrin clots and dental implants following various surface treatments. MATERIALS AND METHODS: In this investigation, 45 dental implants with dimensions of 16 mm in length and 5 mm in diameter were utilized. They were divided up into three groups, each consisting of fifteen samples. Group I: Control; Group II: Ultraviolet (UV) light treated; and group III: Sandblasted and acid-etching (SLA) treated. Healthy volunteers' venous blood samples were drawn into vacutainer tubes without the use of anticoagulants. The samples were centrifuged for 3 minutes at 2700 rpm in a table centrifuge. The entire implant was submerged in room-temperature liquid fibrinogen for 60 minutes. Then, scanning electronic microscopy (SEM) was used to examine each sample. The inter- and intragroup assessments were obtained using the Mann-Whitney U test and the Kruskal-Wallis test; p-values less than 0.05 were regarded as statistically significant. RESULTS: The maximum adhesion of fibrin clot was found in SLA treated group (2.42 ± 0.10) followed by the UV light-treated group (2.18 ± 0.08) and control group (1.20 ± 0.02). There was a statistically significant difference found between the three surface-treated groups (p < 0.001). CONCLUSION: All surface-treatment methods exhibit adhesion between the implant surface and the fibrin clot. However, the highest adherence of fibrin clot was found in SLA treated group compared to the UV light-treated and control group. CLINICAL SIGNIFICANCE: The physical and chemical characteristics of an implant's surface have a significant impact on the way blood clots organize. At the interface between the implant and the bone, blood clot production can initiate and facilitate the healing process. How to cite this article: Jalaluddin M, Ramanna PK, Swain M, et al. Evaluation of Fibrin Clot Interaction with Dental Implant after Different Surface Treatments: An In Vitro Study. J Contemp Dent Pract 2024;25(3):276-279.


Asunto(s)
Implantes Dentales , Fibrina , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Humanos , Técnicas In Vitro , Coagulación Sanguínea , Rayos Ultravioleta , Grabado Ácido Dental
17.
Stomatologiia (Mosk) ; 103(3): 39-41, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38904558

RESUMEN

Ceramic based on zirconium dioxide (ZD) is a modern, durable material for the manufacture of dentures. It is known that ZD is not etched as glass-ceramic, making it difficult to prepare this material before fixing. OBJECTIVE: To study the impact of various methods of surface treatment of ZD-based ceramic on adhesive strength. MATERIALS AND METHODS: Sandblasting with Al2O3 particles sized 50 µm and application of primers with 10-MDP phosphate monomer were used. Adhesive strength values for following 4 groups of samples were obtained: 1st group - RelyX U200 + sandblasting + Compofix new primer (n=9); 2nd group - Compofix + sandblasting + Compofix new primer (n=9); 3rd group - Panavia F 2.0 + sandblasting (n=9); 4th group (control) - Variolink Esthetic DC + sandblasting + Monobond Plus primer (n=9). RESULTS: The highest strength of adhesion was in the 4th group - 48.71±5.71MPa, the smallest in the 3rd group - 9.49±35.24 MPa. Fully domestic components used in the 2nd group allowed to obtain values of 42.50±9.79 MPa. Adhesive strength in the 1st group was 34.11±4.78 MPa. CONCLUSION: The absence of the 10-MDP-based primers application in the preparation of ZD ceramic reduces the adhesive strength between resin cement and its surface. The domestic set for fixation of dentures can be effectively used for ZD on the same basis as European analogue.


Asunto(s)
Propiedades de Superficie , Circonio , Circonio/química , Ensayo de Materiales , Cerámica/química , Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química , Humanos , Cementos Dentales/química , Grabado Dental/métodos
18.
Small ; 19(45): e2304478, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37420322

RESUMEN

Aluminum nanocrystals are emerging as a promising alternative to silver and gold for various applications ranging from plasmonic functionalities to photocatalysis and as energetic materials. Such nanocrystals often exhibit an inherent surface oxidation layer, as aluminum is highly reactive. Its controlled removal is challenging but required, as it can hinder the properties of the encaged metal. Herein, two wet-chemical colloidal approaches toward the surface coating of Al nanocrystals, which afford control over the surface chemistry of the nanocrystals and the oxide thickness, are presented. The first approach utilizes oleic acid as a surface ligand by its addition toward the end of the Al nanocrystals synthesis, and the second approach is the post-synthesis treatment of Al nanocrystals with NOBF4 , in a "wet" colloidal-based approach, which is found to etch and fluorinate the surface oxides. As surface chemistry is an important handle for controlling materials' properties, this research paves a path for manipulating Al nanocrystals while promoting their utilization in diverse applications.

19.
Appl Environ Microbiol ; 89(10): e0114723, 2023 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-37846990

RESUMEN

Antimicrobial blue light (aBL) in the 400-470 nm wavelength range has been reported to kill multiple bacteria. This study assessed its potential for mitigating an important foodborne pathogen, Listeria monocytogenes (Lm), focusing on surface decontamination. Three wavelengths were tested, with gallic acid as a photosensitizing agent (Ps), against dried cells obtained from bacterial suspensions, and biofilms on stainless-steel (SS) coupons. Following aBL exposure, standard microbiological analysis of inoculated coupons was conducted to measure viability. Statistical analysis of variance was performed. Confocal laser scanning microscopy was used to observe the biofilm structures. Within 16 h of exposure at 405 nm, viable Lm dried cells and biofilms were reduced by approx. 3 log CFU/cm2 with doses of 2,672 J/cm2. Application of Ps resulted in an additional 1 log CFU/cm2 at 668 J/cm2, but its effect was not consistent. The highest dose (960 J/cm2) at 420 nm reduced viable counts on the biofilms by 1.9 log CFU/cm2. At 460 nm, after 800 J/cm2, biofilm counts were reduced by 1.6 log CFU/cm2. The effect of material composition on Lm viability was also investigated. Irradiation at 405 nm (668 J/cm2) of cells dried on polystyrene resulted in one of the largest viability reductions (4.0 log CFU/cm2), followed by high-density polyethylene (3.5 log CFU/cm2). Increasing the dose to 4,008 J/cm2 from 405 nm (24 h), improved its efficacy only on SS and polyvinyl chloride. Biofilm micrographs displayed a decrease in biofilm biomass due to the removal of biofilm portions from the surface and a shift from live to dead cells suggesting damage to biofilm cell membranes. These results suggest that aBL is a potential intervention to treat Lm contamination on typical material surfaces used in food production.IMPORTANCECurrent cleaning and sanitation programs are often not capable of controlling pathogen biofilms on equipment surfaces, which transmit the bacteria to ready-to-eat foods. The presence of native plant microbiota and organic matter can protect pathogenic bacteria by reducing the efficacy of sanitizers as well as promoting biofilm formation. Post-operation washing and sanitizing of produce contact surfaces might not be adequate in eliminating the presence of pathogens and commensal bacteria. The use of a dynamic and harmless light technology during downtime and close of operation could serve as a useful tool in preventing biofilm formation and persistence. Antimicrobial blue light (aBL) technology has been explored for hospital disinfection with very promising results, but its application to control foodborne pathogens remains relatively limited. The use of aBL could be a complementary strategy to inactivate surfaces in restaurant or supermarket deli settings.


Asunto(s)
Antiinfecciosos , Listeria monocytogenes , Recuento de Colonia Microbiana , Biopelículas , Antiinfecciosos/farmacología , Luz , Acero Inoxidable , Microbiología de Alimentos
20.
Chemistry ; 29(10): e202203001, 2023 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-36369869

RESUMEN

The roles of organic ammonium salts (OASs) which are widely used for the surface treatment of the perovskite film, including formation of 2D perovskites, direct surface passiviation, and other effects, have been reviewed. The influencing factors for these roles of OASs are also discussed, which are important for improved efficiency and stability of perovskite solar cells. More information can be found in the Review article by X. Guo and co-workers. (DOI: 10.1002/chem.202203001).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA