RESUMEN
The analysis of exhaled breath condensate (EBC) demonstrates a promising avenue of minimally invasive biopsies for diagnostics. EBC is obtained by cooling exhaled air and collecting the condensation to be utilized for downstream analysis using various analytical methods. The aqueous phase of breath contains a large variety of miscible small compounds including polar electrolytes, amino acids, cytokines, chemokines, peptides, small proteins, metabolites, nucleic acids, and lipids/eicosanoids-however, these analytes are typically present at minuscule levels in EBC, posing a considerable technical challenge. Along with recent improvements in devices for breath collection, the sensitivity and resolution of liquid chromatography coupled to online mass spectrometry-based proteomics has attained subfemtomole sensitivity, vastly enhancing the quality of EBC sample analysis. As a result, proteomics analysis of EBC has been expanding the field of breath biomarker research. We present an au courant overview of the achievements in proteomics of EBC, the advancement of EBC collection devices, and the current and future applications for EBC biomarker analysis.
Asunto(s)
Biomarcadores , Pruebas Respiratorias , Espiración , Espectrometría de Masas , Proteómica , Pruebas Respiratorias/métodos , Pruebas Respiratorias/instrumentación , Humanos , Proteómica/métodos , Biomarcadores/análisis , Espectrometría de Masas/métodos , Espectrometría de Masas/instrumentación , Cromatografía Liquida/métodosRESUMEN
Rationale: Respiratory resistance (Rrs) and reactance (Xrs) as measured by oscillometry and their intrabreath changes have emerged as sensitive parameters for detecting early pathological impairments during tidal breathing. Objectives: This study evaluates the prevalence and association of abnormal oscillometry parameters with respiratory symptoms and respiratory diseases in a general adult population. Methods: A total of 7,560 subjects in the Austrian LEAD (Lung, hEart, sociAl, boDy) Study with oscillometry measurements (computed with the Resmon Pro FULL; Restech Srl) were included in this study. The presence of respiratory symptoms and doctor-diagnosed respiratory diseases was assessed using an interview-based questionnaire. Rrs and Xrs at 5 Hz, their inspiratory and expiratory components, the area above the Xrs curve, and the presence of tidal expiratory flow limitation were analyzed. Normality ranges for oscillometry parameters were defined. Measurements and Main Results: The overall prevalence of abnormal oscillometry parameters was 20%. The incidence of abnormal oscillometry increased in the presence of symptoms or diagnoses: 17% (16-18%) versus 27% (25-29%), P < 0.0001. All abnormal oscillometry parameters except Rrs at 5 Hz were significantly associated with respiratory symptoms/diseases. Significant associations were found, even in subjects with normal spirometry, with abnormal oscillometry incidence rates increasing by 6% (4-8%; P < 0.0001) in subjects with symptoms or diagnoses. Conclusions: Abnormal oscillometry parameters are present in one-fifth of this adult population and are significantly associated with respiratory symptoms and disease. Our findings underscore the potential of oscillometry as a tool for detecting and evaluating respiratory impairments, even in individuals with normal spirometry.
Asunto(s)
Pulmón , Enfermedades Respiratorias , Adulto , Humanos , Oscilometría , Respiración , Espiración , Espirometría , Volumen Espiratorio Forzado , Resistencia de las Vías RespiratoriasRESUMEN
Rationale: The respiratory mechanisms of a successful transition of preterm infants after birth are largely unknown. Objectives: To describe intrapulmonary gas flows during different breathing patterns directly after birth. Methods: Analysis of electrical impedance tomography data from a previous randomized trial in preterm infants at 26-32 weeks gestational age. Electrical impedance tomography data for individual breaths were extracted, and lung volumes as well as ventilation distribution were calculated for end of inspiration, end of expiratory braking and/or holding maneuver, and end of expiration. Measurements and Main Results: Overall, 10,348 breaths from 33 infants were analyzed. We identified three distinct breath types within the first 10 minutes after birth: tidal breathing (44% of all breaths; sinusoidal breathing without expiratory disruption), braking (50%; expiratory brake with a short duration), and holding (6%; expiratory brake with a long duration). Only after holding breaths did end-expiratory lung volume increase: Median (interquartile range [IQR]) = 2.0 AU/kg (0.6 to 4.3), 0.0 (-1.0 to 1.1), and 0.0 (-1.1 to 0.4), respectively; P < 0.001]. This was mediated by intrathoracic air redistribution to the left and non-gravity-dependent parts of the lung through pendelluft gas flows during braking and/or holding maneuvers. Conclusions: Respiratory transition in preterm infants is characterized by unique breathing patterns. Holding breaths contribute to early lung aeration after birth in preterm infants. This is facilitated by air redistribution during braking/holding maneuvers through pendelluft flow, which may prevent lung liquid reflux in this highly adaptive situation. This study deciphers mechanisms for a successful fetal-to-neonatal transition and increases our pathophysiological understanding of this unique moment in life. Clinical trial registered with www.clinicaltrials.gov (NCT04315636).
Asunto(s)
Recien Nacido Prematuro , Respiración , Humanos , Recién Nacido , Espiración , Edad Gestacional , Recien Nacido Prematuro/fisiología , Pulmón , Ensayos Clínicos Controlados Aleatorios como AsuntoRESUMEN
The exhaled breath represents an ideal matrix for noninvasive biomarker discovery, and exhaled metabolomics have the potential to be clinically useful in the era of precision medicine. In this concise translational review, we specifically address volatile organic compounds in the breath, with a view toward fulfilling the promise of these as actionable biomarkers, in particular, for lung diseases. We review the literature paying attention to seminal work linked to key milestones in breath research; discuss potential applications for breath biomarkers across disease areas and healthcare systems, including the perspectives of industry; and outline critical aspects of study design that will need to be considered for any pivotal research going forward if breath analysis is to provide robust validated biomarkers that meet the requirements for future clinical implementation.
Asunto(s)
Biomarcadores , Pruebas Respiratorias , Espiración , Compuestos Orgánicos Volátiles , Humanos , Pruebas Respiratorias/métodos , Biomarcadores/análisis , Biomarcadores/metabolismo , Compuestos Orgánicos Volátiles/análisis , Espiración/fisiología , Metabolómica/métodos , Enfermedades Pulmonares/diagnóstico , Enfermedades Pulmonares/metabolismoRESUMEN
Rationale: The early identification of children with poorly controlled asthma is imperative for optimizing treatment strategies. The analysis of exhaled volatile organic compounds (VOCs) is an emerging approach to identify prognostic and diagnostic biomarkers in pediatric asthma. Objectives: To assess the accuracy of gas chromatography-mass spectrometry-based exhaled metabolite analysis to differentiate between controlled and uncontrolled pediatric asthma. Methods: This study encompassed discovery (SysPharmPediA [Systems Pharmacology Approach to Uncontrolled Paediatric Asthma]) and validation (U-BIOPRED [Unbiased Biomarkers for the Prediction of Respiratory Disease Outcomes] and PANDA [Paediatric-Asthma-Non-Invasive-Diagnostic-Approaches]) phases. First, exhaled VOCs that discriminated degrees of asthma control were identified. Subsequently, outcomes were validated in two independent cohorts. Patients were classified as controlled or uncontrolled on the basis of asthma control test scores and the number of severe attacks in the past year. In addition, the potential of VOCs to predict two or more future severe asthma attacks in SysPharmPediA was evaluated. Measurements and Main Results: Complete data were available for 196 children (SysPharmPediA, n = 100; U-BIOPRED, n = 49; PANDA, n = 47). In SysPharmPediA, after randomly splitting the population into training (n = 51) and test (n = 49) sets, three compounds (acetophenone, ethylbenzene, and styrene) distinguished between patients with uncontrolled and controlled asthma. The areas under the receiver operating characteristic curves (AUROCCs) for training and test sets were, respectively, 0.83 (95% confidence interval [CI], 0.65-1.00) and 0.77 (95% CI, 0.58-0.96). Combinations of these VOCs resulted in AUROCCs of 0.74 ± 0.06 (U-BIOPRED) and 0.68 ± 0.05 (PANDA). Attack prediction tests resulted in AUROCCs of 0.71 (95% CI, 0.51-0.91) and 0.71 (95% CI, 0.52-0.90) for the training and test sets. Conclusions: Exhaled metabolite analysis might enable asthma control classification in children. This should stimulate the further development of exhaled metabolite-based point-of-care tests in asthma.
Asunto(s)
Asma , Biomarcadores , Pruebas Respiratorias , Compuestos Orgánicos Volátiles , Humanos , Asma/metabolismo , Asma/tratamiento farmacológico , Compuestos Orgánicos Volátiles/análisis , Niño , Masculino , Femenino , Pruebas Respiratorias/métodos , Biomarcadores/análisis , Biomarcadores/metabolismo , Adolescente , Espiración , Cromatografía de Gases y Espectrometría de Masas , Índice de Severidad de la Enfermedad , PreescolarRESUMEN
Hydrogen peroxide (H2O2) plays a key role in environmental chemistry, biology, and medicine. H2O2 concentrations typically are 6 to 10 orders of magnitude lower than that of water, making its quantitative detection challenging. We demonstrate that optimized NMR spectroscopy allows direct, interference-free, quantitative measurements of H2O2 down to submicromolar levels in a wide range of fluids, ranging from exhaled breath and air condensate to rain, blood, urine, and saliva. NMR measurements confirm the previously reported spontaneous generation of H2O2 in microdroplets that form when condensing water vapor on a hydrophobic surface, which can interfere with atmospheric H2O2 measurements. Its antimicrobial activity and strong seasonal variation speculatively could be linked to the seasonality of respiratory viral diseases.
Asunto(s)
Peróxido de Hidrógeno/análisis , Espectroscopía de Resonancia Magnética/métodos , Aire/análisis , Sangre , Análisis Químico de la Sangre , Líquidos Corporales/química , Espiración/fisiología , Heces/química , Humanos , Lluvia/química , Saliva/química , Orina/químicaRESUMEN
BACKGROUND: Blood eosinophils and fractional exhaled nitric oxide (Feno) are prognostic biomarkers for exacerbations and predict lung function responses to dupilumab in adolescents and adults with asthma. OBJECTIVE: We evaluated the relationship between baseline blood eosinophils and Feno and response to dupilumab in children with asthma. METHODS: Children aged 6 to 11 years with uncontrolled moderate-to-severe asthma (n = 408) were randomized to receive dupilumab 100/200 mg by body weight or volume-matched placebo every 2 weeks for 52 weeks. Annualized exacerbation rate (AER) reduction and least squares mean change in prebronchodilator percent predicted forced expiratory volume in 1 second (ppFEV1) at week 12 were assessed according to cutoff baseline levels for Feno (<20 ppb vs ≥20 ppb) and blood eosinophil count (<150, ≥150 to <300, ≥300 to <500, and ≥500 cells/µL). Quadrant analyses in populations defined by biomarker thresholds and spline models across continuous end points assessed the relationship with Feno and eosinophil count. Interaction testing evaluated the independent roles of Feno and blood eosinophils as predictive markers. RESULTS: Exacerbation risk and magnitude of AER reduction increased in subgroups with higher baseline biomarker levels. Quadrant analyses revealed that disease of patients with either elevated Feno or eosinophil counts demonstrated a clinical response to dupilumab. Interaction testing indicated blood eosinophil counts or Feno independently added value as predictive biomarkers. CONCLUSIONS: In children with uncontrolled moderate-to-severe asthma, blood eosinophil counts and Feno are clinically relevant biomarkers to identify those at risk for asthma exacerbations, as well as those with disease with clinical response to dupilumab. TRIAL REGISTRATION: Liberty Asthma VOYAGE ClinicalTrials.gov NCT02948959.
Asunto(s)
Anticuerpos Monoclonales Humanizados , Asma , Biomarcadores , Eosinófilos , Óxido Nítrico , Humanos , Asma/tratamiento farmacológico , Asma/diagnóstico , Asma/metabolismo , Niño , Eosinófilos/inmunología , Masculino , Femenino , Óxido Nítrico/metabolismo , Pronóstico , Anticuerpos Monoclonales Humanizados/uso terapéutico , Prueba de Óxido Nítrico Exhalado Fraccionado , Recuento de Leucocitos , Antiasmáticos/uso terapéutico , EspiraciónRESUMEN
A variety of organic compounds in human exhaled breath were measured online by mass spectrometry using the fifth (206 nm) and fourth (257 nm) harmonic emissions of a femtosecond ytterbium (Yb) laser as the ionization source. Molecular ions were enhanced significantly by means of resonance-enhanced, two-color, two-photon ionization, which was useful for discrimination of analytes against the background. The limit of detection was 0.15 ppm for acetone in air. The concentration of acetone in exhaled breath was determined for three subjects to average 0.31 ppm, which lies within the range of normal healthy subjects and is appreciably lower than the range for patients with diabetes mellitus. Many other constituents, which could be assigned to acetaldehyde, ethanol, isoprene, phenol, octane, ethyl butanoate, indole, octanol, etc., were observed in the exhaled air. Therefore, the present approach shows potential for use in the online analysis of diabetes mellitus and also for the diagnosis of various diseases, such as COVID-19 and cancers.
Asunto(s)
Pruebas Respiratorias , Rayos Láser , Espectrometría de Masas , Humanos , Pruebas Respiratorias/métodos , Espectrometría de Masas/métodos , COVID-19/diagnóstico , Espiración , Acetona/análisis , Compuestos Orgánicos Volátiles/análisis , Diabetes Mellitus/diagnóstico , SARS-CoV-2/aislamiento & purificación , Límite de DetecciónRESUMEN
Human-borne acetone is a potent marker of lipid metabolism. Here, an enzyme immobilization method for secondary alcohol dehydrogenase (S-ADH), which is suitable for highly sensitive and selective biosensing of acetone, was developed, and then its applicability was demonstrated for spatiotemporal imaging of concentration distribution. After various investigations, S-ADH-immobilized meshes could be prepared with less than 5% variation by cross-linking S-ADH with glutaraldehyde on a cotton mesh at 40 °C for 15 min. Furthermore, high activity was obtained by adjusting the concentration of the coenzyme nicotinamide adenine dinucleotide (NADH) solution added to the S-ADH-immobilized mesh to 500 µM and the solvent to a potassium phosphate buffer solution at pH 6.5. The gas imaging system using the S-ADH-immobilized mesh was able to image the decrease in NADH fluorescence (ex 340 nm, fl 490 nm) caused by the catalytic reaction of S-ADH and the acetone distribution in the concentration range of 0.1-10 ppm-v, including the breath concentration of healthy people at rest. The exhaled breath of two healthy subjects at 6 h of fasting was quantified as 377 and 673 ppb-v, which were consistent with the values quantified by gas chromatography-mass spectrometry.
Asunto(s)
Acetona , Pruebas Respiratorias , Enzimas Inmovilizadas , Acetona/análisis , Acetona/química , Humanos , Enzimas Inmovilizadas/química , Enzimas Inmovilizadas/metabolismo , Técnicas Biosensibles , Oxidorreductasas de Alcohol/química , Oxidorreductasas de Alcohol/metabolismo , Gases/química , Gases/análisis , Espiración , NAD/análisis , NAD/química , NAD/metabolismoRESUMEN
Accelerations and decelerations of heart rate are nonsymmetrical in the magnitude and number of beat-to-beat changes. The asymmetric features of heart rate variability are related to respiratory durations. To explore the link between respiration and heart rate asymmetry (HRA), we evaluated 14 seated, healthy young adults who breathed with nine combinations of inspiration duration (TI) and expiration duration (TE), chosen respectively from 2, 4, and 6 s. A 5-min R-R interval (RRI) time series was obtained from each study period to construct an averaged pattern waveform relative to the respiratory cycle. We observed that the time interval between inspiration onset and RRI minimum progressively lengthened as TI and TE increased. The time interval between expiration onset and RRI maximum also lengthened when TE increased but shortened when TI increased. Consequently, TI and TE had different effects on the acceleration time (AT; from RRI maximum to RRI minimum) and deceleration time (DT; from RRI minimum to RRI maximum). The percentage of AT within the respiratory cycle showed a strong correlation with traditional Guzik's (r = 0.862, P < 0.001) and Porta's (r = 0.878, P < 0.001) indexes of HRA assessed in a Poincaré plot analysis. These findings suggest that, in addition to considering the magnitude and number of beat-to-beat changes, HRA can also be assessed based on another aspect: the duration of consecutive changes. The stepwise link between the duration of heart rate change and respiratory duration provides insight into the mechanisms connecting respiration to HRA.NEW & NOTEWORTHY In healthy adults who regulated their breathing across nine combinations of inspiration and expiration durations, we used averaged pattern waveform technique to quantify the durations of heart rate acceleration and deceleration within the respiratory cycle. The percent duration of acceleration showed a strong correlation with traditional heart rate asymmetry indexes, which evaluate the magnitude and number of beat-to-beat changes. This new approach opens a window to explore the asymmetric features of heart rate variability.
Asunto(s)
Frecuencia Cardíaca , Humanos , Masculino , Femenino , Adulto Joven , Adulto , Aceleración , Factores de Tiempo , Espiración/fisiología , Inhalación/fisiología , Respiración , ElectrocardiografíaRESUMEN
INTRODUCTION: Volatile organic compounds (VOCs) can arise from underlying metabolism and are detectable in exhaled breath, therefore offer a promising route to non-invasive diagnostics. Robust, precise, and repeatable breath measurement platforms able to identify VOCs in breath distinguishable from background contaminants are needed for the confident discovery of breath-based biomarkers. OBJECTIVES: To build a reliable breath collection and analysis method that can produce a comprehensive list of known VOCs in the breath of a heterogeneous human population. METHODS: The analysis cohort consisted of 90 pairs of breath and background samples collected from a heterogenous population. Owlstone Medical's Breath Biopsy® OMNI® platform, consisting of sample collection, TD-GC-MS analysis and feature extraction was utilized. VOCs were determined to be "on-breath" if they met at least one of three pre-defined metrics compared to paired background samples. On-breath VOCs were identified via comparison against purified chemical standards, using retention indexing and high-resolution accurate mass spectral matching. RESULTS: 1471 VOCs were present in > 80% of samples (breath and background), and 585 were on-breath by at least one metric. Of these, 148 have been identified covering a broad range of chemical classes. CONCLUSIONS: A robust breath collection and relative-quantitative analysis method has been developed, producing a list of 148 on-breath VOCs, identified using purified chemical standards in a heterogenous population. Providing confirmed VOC identities that are genuinely breath-borne will facilitate future biomarker discovery and subsequent biomarker validation in clinical studies. Additionally, this list of VOCs can be used to facilitate cross-study data comparisons for improved standardization.
Asunto(s)
Pruebas Respiratorias , Cromatografía de Gases y Espectrometría de Masas , Compuestos Orgánicos Volátiles , Compuestos Orgánicos Volátiles/análisis , Pruebas Respiratorias/métodos , Humanos , Cromatografía de Gases y Espectrometría de Masas/métodos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Biomarcadores/análisis , Anciano , Adulto Joven , EspiraciónRESUMEN
BACKGROUND: The multitude of metabolites generated by physiological processes in the body can serve as valuable biomarkers for many clinical purposes. They can provide a window into relevant metabolic pathways for health and disease, as well as be candidate therapeutic targets. A subset of these metabolites generated in the human body are volatile, known as volatile organic compounds (VOCs), which can be detected in exhaled breath. These can diffuse from their point of origin throughout the body into the bloodstream and exchange into the air in the lungs. For this reason, breath VOC analysis has become a focus of biomedical research hoping to translate new useful biomarkers by taking advantage of the non-invasive nature of breath sampling, as well as the rapid rate of collection over short periods of time that can occur. Despite the promise of breath analysis as an additional platform for metabolomic analysis, no VOC breath biomarkers have successfully been implemented into a clinical setting as of the time of this review. AIM OF REVIEW: This review aims to summarize the progress made to address the major methodological challenges, including standardization, that have historically limited the translation of breath VOC biomarkers into the clinic. We highlight what steps can be taken to improve these issues within new and ongoing breath research to promote the successful development of the VOCs in breath as a robust source of candidate biomarkers. We also highlight key recent papers across select fields, critically reviewing the progress made in the past few years to advance breath research. KEY SCIENTIFIC CONCEPTS OF REVIEW: VOCs are a set of metabolites that can be sampled in exhaled breath to act as advantageous biomarkers in a variety of clinical contexts.
Asunto(s)
Biomarcadores , Pruebas Respiratorias , Espiración , Metabolómica , Compuestos Orgánicos Volátiles , Humanos , Compuestos Orgánicos Volátiles/análisis , Compuestos Orgánicos Volátiles/metabolismo , Pruebas Respiratorias/métodos , Biomarcadores/metabolismo , Biomarcadores/análisis , Metabolómica/métodosRESUMEN
INTRODUCTION: This study employs Proton-Transfer-Reaction Mass Spectrometry (PTR-MS) to analyze exhaled breath profiles of 504 healthy adults, focusing on nine common volatile organic compounds (VOCs): acetone, acetaldehyde, acetonitrile, ethanol, isoprene, methanol, propanol, phenol, and toluene. PTR-MS offers real-time VOC measurement, crucial for understanding breath biomarkers and their applications in health assessment. OBJECTIVES: The study aims to investigate how demographic factors-gender, age, and smoking history-affect VOC concentrations in exhaled breath. The objective is to enhance our understanding of breath biomarkers and their potential for health monitoring and clinical diagnosis. METHODS: Exhaled breath samples were collected using PTR-MS, measuring concentrations of nine VOCs. The data were analyzed to discern distribution patterns across demographic groups. RESULTS: Males showed higher average VOC levels for certain compounds. Propanol and methanol concentrations significantly increased with age. Smoking history influenced VOC levels, with differences among non-smokers, current smokers, and ex-smokers. CONCLUSION: This research provides valuable insights into demographic influences on exhaled VOC profiles, emphasizing the potential of breath analysis for health assessment. PTR-MS's real-time measurement capabilities are crucial for capturing dynamic VOC changes, offering advantages over conventional methods. These findings lay a foundation for advancements in non-invasive disease detection, highlighting the importance of considering demographics in breath biomarker research.
Asunto(s)
Pruebas Respiratorias , Voluntarios Sanos , Espectrometría de Masas , Compuestos Orgánicos Volátiles , Humanos , Masculino , Pruebas Respiratorias/métodos , Femenino , Compuestos Orgánicos Volátiles/análisis , Adulto , Persona de Mediana Edad , Espectrometría de Masas/métodos , Adulto Joven , Anciano , Espiración , Biomarcadores/análisis , Adolescente , Fumar/metabolismoRESUMEN
BACKGROUND: Breath testing using an electronic nose has been recognized as a promising new technique for the early detection of lung cancer. Imbalanced data are commonly observed in electronic nose studies, but methods to address them are rarely reported. OBJECTIVE: The objectives of this study were to assess the accuracy of electronic nose screening for lung cancer with imbalanced learning and to select the best mechanical learning algorithm. METHODS: We conducted a caseâcontrol study that included patients with lung cancer and healthy controls and analyzed metabolites in exhaled breath using a carbon nanotube sensor array. The study used five machine learning algorithms to build predictive models and a synthetic minority oversampling technique to address imbalanced data. The diagnostic accuracy of lung cancer was assessed using pathology reports as the gold standard. RESULTS: We enrolled 190 subjects between 2020 and 2023. A total of 155 subjects were used in the final analysis, which included 111 lung cancer patients and 44 healthy controls. We randomly divided samples into one training set, one internal validation set, and one external validation set. In the external validation set, the summary sensitivity was 0.88 (95% CI 0.84-0.91), the summary specificity was 1.00 (95% CI 0.85-1.00), the AUC was 0.96 (95% CI 0.94-0.98), the pAUC was 0.92 (95% CI 0.89-0.96), and the DOR was 207.62 (95% CI 24.62-924.64). CONCLUSION: Electronic nose screening for lung cancer is highly accurate. The support vector machine algorithm is more suitable for analyzing chemical sensor data from electronic noses.
Asunto(s)
Neoplasias Pulmonares , Compuestos Orgánicos Volátiles , Humanos , Neoplasias Pulmonares/diagnóstico , Estudios de Casos y Controles , Pruebas Respiratorias/métodos , Espiración , Nariz ElectrónicaRESUMEN
BACKGROUND: The reference values of eNO have certain differences among people of different countries and races. We aimed to obtain the reference value of eNO in healthy children and adolescents (6-18 years old) in China and to explore the associations between the reference values with ages, gender, heights, BMI, and regions. METHODS: We measured FeNO50 levels in 5949 healthy Chinese children and adolescents, FeNO200 and CaNO levels in 658 participants from 16 provinces of 7 administrative areas in China aged 6-18. All persons were studied after obtaining informed consent from children and their parents. RESULTS: The mean FeNO50 of 5949 Chinese children and adolescents aged 6-18 years was 14.1 ppb, with a 95% confidence interval of 1-38.1 ppb. The mean FeNO200 of 658 persons was 6.9 ppb with a 95% upper confidence interval of 15.0 ppb, and the mean CaNO was 3.0 ppb with a 95% upper confidence interval of 11.2 ppb. In the 6-11 age group, age and height were correlated with the logarithm of FeNO50 (P < 0.001, P < 0.05). There was no significant correlation between the logarithm of FeNO200 and gender, age, height and BMI (all P > 0.05). The logarithm of CaNO was correlated with gender (P < 0.05). In the 12-18 age group, gender, height, and region were correlated with the logarithm of FeNO50 (all P < 0.001). There was only a weak correlation between the logarithm of FeNO200 and height (P < 0.001). The logarithm of CaNO was negatively correlated with age (P < 0.05). CONCLUSIONS: Higher FeNO50, FeNO200 and CaNO values were found in healthy children and adolescents in China compared with foreign reports, and is affected by age, height, gender, and region. This study provides useful references for clinical application of eNO in children, especially Asian children.
Asunto(s)
Pruebas Respiratorias , Espiración , Óxido Nítrico , Humanos , Adolescente , Niño , Masculino , Femenino , Valores de Referencia , China/epidemiología , Óxido Nítrico/análisis , Óxido Nítrico/metabolismo , Estudios Transversales , Espiración/fisiología , Pruebas Respiratorias/métodos , Voluntarios Sanos , Factores de EdadRESUMEN
BACKGROUND: Lung cancer (LC), characterized by high incidence and mortality rates, presents a significant challenge in oncology. Despite advancements in treatments, early detection remains crucial for improving patient outcomes. The accuracy of screening for LC by detecting volatile organic compounds (VOCs) in exhaled breath remains to be determined. METHODS: Our systematic review, following PRISMA guidelines and analyzing data from 25 studies up to October 1, 2023, evaluates the effectiveness of different techniques in detecting VOCs. We registered the review protocol with PROSPERO and performed a systematic search in PubMed, EMBASE and Web of Science. Reviewers screened the studies' titles/abstracts and full texts, and used QUADAS-2 tool for quality assessment. Then performed meta-analysis by adopting a bivariate model for sensitivity and specificity. RESULTS: This study explores the potential of VOCs in exhaled breath as biomarkers for LC screening, offering a non-invasive alternative to traditional methods. In all studies, exhaled VOCs discriminated LC from controls. The meta-analysis indicates an integrated sensitivity and specificity of 85% and 86%, respectively, with an AUC of 0.93 for VOC detection. We also conducted a systematic analysis of the source of the substance with the highest frequency of occurrence in the tested compounds. Despite the promising results, variability in study quality and methodological challenges highlight the need for further research. CONCLUSION: This review emphasizes the potential of VOC analysis as a cost-effective, non-invasive screening tool for early LC detection, which could significantly improve patient management and survival rates.
Asunto(s)
Pruebas Respiratorias , Detección Precoz del Cáncer , Neoplasias Pulmonares , Compuestos Orgánicos Volátiles , Humanos , Compuestos Orgánicos Volátiles/análisis , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/metabolismo , Detección Precoz del Cáncer/métodos , Pruebas Respiratorias/métodos , Espiración , Sensibilidad y Especificidad , Biomarcadores de Tumor/análisis , Biomarcadores de Tumor/metabolismoRESUMEN
Electronic cigarette smoking (or vaping) is on the rise, presenting questions about the effects of secondhand exposure. The chemical composition of vape emissions was examined in the exhaled breath of eight human volunteers with the high chemical specificity of complementary online and offline techniques. Our study is the first to take multiple exhaled puff measurements from human participants and compare volatile organic compound (VOC) concentrations between two commonly used methods, proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS) and gas chromatography (GC). Five flavor profile groups were selected for this study, but flavor compounds were not observed as the main contributors to the PTR-ToF-MS signal. Instead, the PTR-ToF-MS mass spectra were overwhelmed by e-liquid thermal decomposition and fragmentation products, which masked other observations regarding flavorings and other potentially toxic species associated with secondhand vape exposure. Compared to the PTR-ToF-MS, GC measurements reported significantly different VOC concentrations, usually below those from PTR-ToF-MS. Consequently, PTR-ToF-MS mass spectra should be interpreted with caution when reporting quantitative results in vaping studies, such as doses of inhaled VOCs. Nevertheless, the online PTR-ToF-MS analysis can provide valuable qualitative information by comparing relative VOCs in back-to-back trials. For example, by comparing the mass spectra of exhaled air with those of direct puffs, we can conclude that harmful VOCs present in the vape emissions are largely absorbed by the participants, including large fractions of nicotine.
Asunto(s)
Compuestos Orgánicos Volátiles , Humanos , Compuestos Orgánicos Volátiles/análisis , Masculino , Adulto , Pruebas Respiratorias , Femenino , Espectrometría de Masas , Vapeo/efectos adversos , Espiración , Sistemas Electrónicos de Liberación de Nicotina , Adulto Joven , Cromatografía de GasesRESUMEN
Emerging data from clinical studies have shown pro-inflammatory effects associated with e-cigarette use. Fractional exhaled nitric oxide (FeNO) is a biomarker of pulmonary type 2 (T2) inflammation. The effect of chronic e-cigarette use on FeNO is unclear. The aim of this study was to compare FeNO levels in COPD ex-smokers who use e-cigarettes (COPDE + e-cig) to COPDE ex-smokers (COPDE) and COPD current smokers (COPDS). FeNO levels were significantly higher in COPDE + e-cig (median 16.2 ppb) and COPDE (median 18.0 ppb) compared to COPDS (median 7.6 ppb) (p = 0.0003 and p < 0.0001 respectively). There was no difference in FeNO levels between COPDE + e-cig compared to COPDE (p > 0.9). The importance of our results is that electronic cigarette use does not alter the interpretation of FeNO results, and so does not interfere with the use of FeNO as a practical biomarker of T2 inflammation, unlike current cigarette smoking in COPD. Whilst the effect of electronic cigarette use on FeNO levels is not the same as cigarette smoke, this cannot be taken as evidence that electronic cigarettes are harmless. These differential pulmonary effects can be attributed to differences in the chemical composition of the two products.
Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Óxido Nítrico , Pruebas Respiratorias , Inflamación , Espiración , BiomarcadoresRESUMEN
BACKGROUND: Patient-ventilator dyssynchrony is frequently observed during assisted mechanical ventilation. However, the effects of expiratory muscle contraction on patient-ventilator interaction are underexplored. The authors hypothesized that active expiration would affect patient-ventilator interaction and they tested their hypothesis in a mixed cohort of invasively ventilated patients with spontaneous breathing activity. METHODS: This is a retrospective observational study involving patients on assisted mechanical ventilation who had their esophageal pressure (Peso) and gastric pressure monitored for clinical purposes. Active expiration was defined as gastric pressure rise (ΔPgas) greater than or equal to 1.0 cm H2O during expiratory flow without a corresponding change in diaphragmatic pressure. Waveforms of Peso, gastric pressure, diaphragmatic pressure, flow, and airway pressure (Paw) were analyzed to identify and characterize abnormal patient-ventilator interaction. RESULTS: 76 patients were identified with Peso and gastric pressure recordings, of whom 58 demonstrated active expiration with a median ΔPgas of 3.4 cm H2O (interquartile range = 2.4 to 5.3) observed in this subgroup. Among these 58 patients, 23 presented the following events associated with expiratory muscle activity: (1) distortions in Paw and flow that resembled ineffective efforts, (2) distortions similar to autotriggering, (3) multiple triggering, (4) prolonged ventilatory cycles with biphasic inspiratory flow, with a median percentage (interquartile range) increase in mechanical inflation time and tidal volume of 54% (44 to 70%) and 25% (8 to 35%), respectively and (5) breathing exclusively by expiratory muscle relaxation. Gastric pressure monitoring was required to identify the association of active expiration with these events. Respiratory drive, assessed by the rate of inspiratory Peso decrease, was significantly higher in patients with active expiration (median [interquartile range] dPeso/dt: 12.7 [9.0 to 18.5] vs 9.2 [6.8 to 14.2] cmH2O/sec; P < 0.05). CONCLUSIONS: Active expiration can impair patient-ventilator interaction in critically ill patients. Without documenting gastric pressure, abnormal patient-ventilator interaction associated with expiratory muscle contraction may be mistakenly attributed to a mismatch between the patient's inspiratory effort and mechanical inflation. This misinterpretation could potentially influence decisions regarding clinical management.
Asunto(s)
Espiración , Respiración Artificial , Estómago , Humanos , Estudios Retrospectivos , Masculino , Femenino , Persona de Mediana Edad , Espiración/fisiología , Anciano , Estómago/fisiología , Respiración Artificial/métodos , Monitoreo Fisiológico/métodos , Presión , Esófago/fisiología , Esófago/fisiopatologíaRESUMEN
RATIONALE: Secondary-electrospray ionization (SESI) coupled with high-resolution mass spectrometry is a powerful tool for the discovery of biomarkers in exhaled breath. A primary electrospray consisting of aqueous formic acid (FA) is currently used to charge the volatile organic compounds in breath. To investigate whether alternate electrospray compositions could enable different metabolite coverage and sensitivities, the electrospray dopants NaI and AgNO3 were tested. METHODS: In a proof-of-principle manner, the exhaled breath of one subject was analyzed repeatedly with different electrospray solutions and with the help of a spectral stitching technique. Capillary diameter and position were optimized to achieve proper detection of exhaled breath. The detected features were then compared using formula annotation. Using an evaporation-based gas standard system, the signal response of the different solutions was probed. RESULTS: Principal component analysis revealed a substantial difference in features detected with AgNO3 . With silver, more sulfur-containing features and more unsaturated hydrocarbon compounds were detected. Furthermore, more primary amines were potentially ionized, as indicated by van Krewelen diagrams. In total, twice as many features were unique to AgNO3 than for other electrospray dopants. Using gas standards at known concentrations, the high sensitivity of FA as a dopant was demonstrated but also indicated alternate sensitivities of the other electrospray solutions. CONCLUSIONS: This work demonstrated the potential of AgNO3 as a complementary dopant for further biomarker discovery in SESI-based breath analysis.