Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.708
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 25(1): e14232, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38088260

RESUMEN

PURPOSE: This study aims to assess the accuracy of a modified electron beam calibration based on the IAEA TRS-398 and AAPM-TG-51 in multicenter radiotherapy. METHODS: This study was performed using the Elekta and Varian Linear Accelerator electron beams with energies of 4-22 MeV under reference conditions using cylindrical (PTW 30013, IBA FC65-G, and IBA FC65-P) and parallel-plate (PTW 34045, PTW 34001, and IBA PPC-40) chambers. The modified calibration used a cylindrical chamber and an updated k ' Q $k{^{\prime}}_Q$ based on Monte Carlo calculations, whereas TRS-398 and TG-51 used cylindrical and parallel-plate chambers for reference dosimetry. The dose ratio of the modified calibration procedure, TRS-398 and TG-51 were obtained by comparing the dose at the maximum depth of the modified calibration to TRS-398 and TG-51. RESULTS: The study found that all cylindrical chambers' beam quality conversion factors determined with the modified calibration ( k ' Q ) $( {{{k^{\prime}}}_Q} )$ to the TRS-398 and TG-51 vary from 0.994 to 1.003 and 1.000 to 1.010, respectively. The dose ratio of modified/TRS-398cyl and modified/TRS-398parallel-plate, the variation ranges were 0.980-1.014 and 0.981-1.019, while for the counterpart modified/TG-51cyl was found varying between 0.991 and 1.017 and the ratio of modified/TG-51parallel-plate varied in the range of 0.981-1.019. CONCLUSION: This multi-institutional study analyzed a modified calibration procedure utilizing new data for electron beam calibrations at multiple institutions and evaluated existing calibration protocols. Based on observed variations, the current calibration protocols should be updated with detailed metrics on the stability of linac components.


Asunto(s)
Electrones , Fenilpropionatos , Radioterapia de Alta Energía , Humanos , Radioterapia de Alta Energía/métodos , Calibración , Agua , Radiometría/métodos , Fotones
2.
Strahlenther Onkol ; 197(6): 520-527, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33938967

RESUMEN

PURPOSE: Intensity-modulated radiotherapy (IMRT) for cervical cancer yields favorable results in terms of oncological outcomes, acute toxicity, and late toxicity. Limited data are available on clinical results with volumetric modulated arc therapy (VMAT). This study's purpose is to compare outcome and toxicity with VMAT to conventional 3D conformal radiotherapy (3DCRT), giving special consideration to the influence of patient- and treatment-related parameters on side effects. MATERIALS AND METHODS: Patients with cervical cancer stage I-IVA underwent radiotherapy alone or chemoradiotherapy using 3DCRT (n = 75) or VMAT (n = 30). Survival endpoints were overall survival, progression-free survival, and locoregional control. The National Cancer Institute Common Terminology Criteria for Adverse Events and the Late Effects of Normal Tissues criteria were used for toxicity assessment. Toxicity and patient- and treatment-related parameters were included in a multivariable model. RESULTS: There were no differences in survival rates between treatment groups. VMAT significantly reduced late small bowel toxicity (OR = 0.10, p = 0.03). Additionally, VMAT was associated with an increased risk of acute urinary toxicity (OR = 2.94, p = 0.01). A low body mass index (BMI; OR = 2.46, p = 0.03) and overall acute toxicity ≥grade 2 (OR = 4.17, p < 0.01) were associated with increased overall late toxicity. CONCLUSION: We demonstrated significant reduction of late small bowel toxicity with VMAT treatment, an improvement in long-term morbidity is conceivable. VMAT-treated patients experienced acute urinary toxicity more frequently. Further analysis of patient- and treatment-related parameters indicates that the close monitoring of patients with low BMI and of patients who experienced relevant acute toxicity during follow-up care could improve late toxicity profiles.


Asunto(s)
Radioterapia Conformacional/métodos , Neoplasias del Cuello Uterino/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Braquiterapia/efectos adversos , Braquiterapia/métodos , Quimioradioterapia/efectos adversos , Cisplatino/efectos adversos , Cisplatino/uso terapéutico , Femenino , Estudios de Seguimiento , Humanos , Intestino Delgado/efectos de la radiación , Persona de Mediana Edad , Análisis Multivariante , Supervivencia sin Progresión , Traumatismos por Radiación/etiología , Radioterapia Conformacional/efectos adversos , Radioterapia de Alta Energía/efectos adversos , Radioterapia de Alta Energía/métodos , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Tasa de Supervivencia , Sistema Urinario/efectos de la radiación , Neoplasias del Cuello Uterino/terapia
3.
Pediatr Blood Cancer ; 67(2): e28018, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31710168

RESUMEN

BACKGROUND: Extraskeletal osteosarcoma is an extremely rare disease, comprising less than 0.1% of all cancers diagnosed in the United States, of which less than 5% occur in the upper extremities. The management of two cases of pediatric upper extremity extraskeletal osteosarcoma is discussed. CASE DESCRIPTION: Two children initially noticed painless left upper extremity masses at the ages of 16 and 13, respectively. Following a period of several months, both lesions became symptomatic, necessitating operative intervention, which revealed giant cell-rich extraskeletal osteosarcoma; PET staging following gross total resection revealed no residual or metastatic disease in either patient. After extensive discussion with the patients and family, adjuvant chemotherapy was initiated for one patient, and adjuvant radiation therapy was initiated in both patients. CONCLUSIONS: Despite the rarity of these tumors, the importance of radiation therapy has been established by current and ongoing studies such as the Children's Oncology Group study ARST0332. Radiation therapy remains an important component of the multimodality therapy comprising optimal treatment of this disease, despite the relative paucity of long-term outcome data derived from level I evidence.


Asunto(s)
Neoplasias Óseas/radioterapia , Osteosarcoma/radioterapia , Radioterapia de Alta Energía/métodos , Neoplasias de los Tejidos Blandos/radioterapia , Extremidad Superior/efectos de la radiación , Adolescente , Neoplasias Óseas/patología , Humanos , Masculino , Osteosarcoma/patología , Fotones , Pronóstico , Neoplasias de los Tejidos Blandos/patología
4.
J Appl Clin Med Phys ; 21(3): 68-74, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32034989

RESUMEN

PURPOSE: Treating deep-seated bulky tumors with traditional single-field Cerrobend GRID-blocks has many limitations such as suboptimal target coverage and excessive skin toxicity. Heavy traditional GRID-blocks are a concern for patient safety at various gantry-angles and dosimetric detail is not always available without a GRID template in user's treatment planning system. Herein, we propose a simple, yet clinically useful multileaf collimator (MLC)-based three-dimensional (3D)-crossfire technique to provide sufficient target coverage, reduce skin dose, and potentially escalate tumor dose to deep-seated bulky tumors. MATERIALS/METHODS: Thirteen patients (multiple sites) who underwent conventional single-field cerrobend GRID-block therapy (maximum, 15 Gy in 1 fraction) were re-planned using an MLC-based 3D-crossfire method. Gross tumor volume (GTV) was used to generate a lattice pattern of 10 mm diameter and 20 mm center-to-center mimicking conventional GRID-block using an in-house MATLAB program. For the same prescription, MLC-based 3D-crossfire grid plans were generated using 6-gantry positions (clockwise) at 60° spacing (210°, 270°, 330°, 30°, 90°, 150°, therefore, each gantry angle associated with a complement angle at 180° apart) with differentially-weighted 6 or 18 MV beams in Eclipse. For each gantry, standard Millenium120 (Varian) 5 mm MLC leaves were fit to the grid-pattern with 90° collimator rotation, so that the tunneling dose distribution was achieved. Acuros-based dose was calculated for heterogeneity corrections. Dosimetric parameters evaluated include: mean GTV dose, GTV dose heterogeneities (peak-to-valley dose ratio, PVDR), skin dose and dose to other adjacent critical structures. Additionally, planning time and delivery efficiency was recorded. With 3D-MLC, dose escalation up to 23 Gy was simulated for all patient's plans. RESULTS: All 3D-MLC crossfire GRID plans exhibited excellent target coverage with mean GTV dose of 13.4 ± 0.5 Gy (range: 12.43-14.24 Gy) and mean PVDR of 2.0 ± 0.3 (range: 1.7-2.4). Maximal and dose to 5 cc of skin were 9.7 ± 2.7 Gy (range: 5.4-14.0 Gy) and 6.3 ± 1.8 Gy (range: 4.1-11.1 Gy), on average respectively. Three-dimensional-MLC treatment planning time was about an hour or less. Compared to traditional GRID-block, average beam on time was 20% less, while providing similar overall treatment time. With 3D-MLC plans, tumor dose can be escalated up to 23 Gy while respecting skin dose tolerances. CONCLUSION: The simple MLC-based 3D-crossfire GRID-therapy technique resulted in enhanced target coverage for de-bulking deep-seated bulky tumors, reduced skin toxicity and spare adjacent critical structures. This simple MLC-based approach can be easily adopted by any radiotherapy center. It provides detailed dosimetry and a safe and effective treatment by eliminating the heavy physical GRID-block and could potentially provide same day treatment. Prospective clinical trial with higher tumor-dose to bulky deep-seated tumors is anticipated.


Asunto(s)
Neoplasias/radioterapia , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Alta Energía/instrumentación , Radioterapia de Alta Energía/métodos , Humanos , Pronóstico , Dosificación Radioterapéutica , Estudios Retrospectivos
5.
Can J Urol ; 26(4): 9809-9820, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31469635

RESUMEN

INTRODUCTION: To assess the impact of primary and secondary therapies for high- and intermediate-risk prostate cancer on health-related quality of life (HRQoL). MATERIALS AND METHODS: A prospective study was initiated in 2007 at Center for Prostate Disease Research Multicenter National Database sites. Longitudinal patterns in HRQoL from baseline (pre-treatment) to 5 years post-diagnosis were examined for patients with high- and intermediate-risk prostate cancer, treated by radical prostatectomy (RP) or external beam radiation therapy (EBRT). Change in HRQoL was modeled using linear regression models fit with generalized estimating equations. The probability of maintaining HRQoL was compared between patients receiving RP only versus RP with secondary treatment. RESULTS: Of 445 men with high- and intermediate-risk prostate cancer, 228 underwent RP and 143 had EBRT± androgen deprivation therapy (ADT). Fifty received secondary therapy (EBRT and/or ADT or chemotherapy) after RP. RP patients showed a greater decline over time in sexual function and bother and urinary function compared to EBRT±ADT patients. Patients who had secondary therapy after RP were less likely to maintain their HRQoL compared to those who had RP alone. These differences were most pronounced for sexual and hormonal function. CONCLUSIONS: Prostate cancer patients experience significant declines in HRQoL after primary therapy. Additional secondary therapy after RP, in the form of EBRT and/or ADT, appears to be responsible for further deterioration in HRQoL outcomes.


Asunto(s)
Recurrencia Local de Neoplasia/terapia , Prostatectomía/métodos , Neoplasias de la Próstata/psicología , Neoplasias de la Próstata/terapia , Calidad de Vida , Radioterapia de Alta Energía/métodos , Anciano , Antagonistas de Andrógenos/administración & dosificación , Bases de Datos Factuales , Supervivencia sin Enfermedad , Humanos , Modelos Lineales , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Invasividad Neoplásica/patología , Recurrencia Local de Neoplasia/patología , Estadificación de Neoplasias , Estudios Prospectivos , Prostatectomía/mortalidad , Neoplasias de la Próstata/mortalidad , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica , Radioterapia de Alta Energía/mortalidad , Medición de Riesgo , Análisis de Supervivencia , Resultado del Tratamiento , Estados Unidos
6.
J Appl Clin Med Phys ; 19(3): 351-354, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29493079

RESUMEN

AAPM Report 142 recommends and the State of Ohio requires that the imaging dose be quantified in radiotherapy applications. Using the TG51 dose calibration protocol for MV Imaging dose measurement requires knowledge of the kQ parameter for the beam quality and the ionization chamber type under investigation. The %dd(10)x of the Varian TrueBeam 2.5 MV imaging beam falls outside the range of the available data for the calculation of the kQ value. Due to the similarities of the 2.5 MV imaging beam and the 60 Co beam, we and others made the assumption that kQ = 1.0 in TG51 calculations. In this study, we used the TG21 and TG51 calibration protocols in conjunction to validate that kQ = 1.0 for the 2.5 MV imaging beam using a PTW 30013 farmer chamber. Standard measurements for TG51 absolute dosimetry QA were performed at 100 cm SSD, 10 cm depth, 10 × 10 field size, delivering 100 Monitor Units to a waterproof Farmer Chamber (PTW TN30013) for both 2.5 and 6 MV. Both the TG21 and TG51 formalisms were used to calculate the dose to water per MU at dmax (Dw /MU) for the 6 MV beam. The calculated outputs were 1.0005 and 1.0004 cGy/MU respectively. The TG21 formalism was then used to calculate (Dw /MU) for the 2.5 MV imaging beam. This value was then used in the TG51 formalism to find kQ for the 2.5 MV imaging beam. A kQ value of 1.00 ± 0.01 was calculated for 2.5 MV using this method.


Asunto(s)
Modelos Teóricos , Fantasmas de Imagen , Monitoreo de Radiación/instrumentación , Monitoreo de Radiación/métodos , Radioterapia de Alta Energía/instrumentación , Radioterapia de Alta Energía/métodos , Calibración , Electrones , Humanos , Fotones , Radiometría/métodos
7.
Osteoporos Int ; 28(6): 1915-1923, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28243706

RESUMEN

This study deals with the role of texture analysis as a predictive factor of radiation-induced insufficiency fractures in patients undergoing pelvic radiation. INTRODUCTION: This study aims to assess the texture analysis (TA) of computed tomography (CT) simulation scans as a predictive factor of insufficiency fractures (IFs) in patients with pelvic malignancies undergoing radiation therapy (RT). METHODS: We performed an analysis of patients undergoing pelvic RT from January 2010 to December 2014, 24 of whom had developed pelvic bone IFs. We analyzed CT-simulation images using ImageJ macro software and selected two regions of interest (ROIs), which are L5 body and the femoral head. TA parameters included mean (m), standard deviation (SD), skewness (sk), kurtosis (k), entropy (e), and uniformity (u). The IFs patients were compared (1:2 ratio) with controlled patients who had not developed IFs and matched for sex, age, menopausal status, type of tumor, use of chemotherapy, and RT dose. A reliability test of intra- and inter-reader ROI TA reproducibility with the intra-class correlation coefficient (ICC) was performed. Univariate and multivariate analyses (logistic regression) were applied for TA parameters observed both in the IFs and the controlled groups. RESULTS: Inter- and intra-reader ROI TA was highly reproducible (ICC > 0.90). Significant TA parameters on paired t test included L5 m (p = 0.001), SD (p = 0.002), k (p = 0.006), e (p = 0.004), and u (p = 0.015) and femoral head m (p < 0.001) and SD (p = 0.001), whereas on logistic regression analysis, L5 e (p = 0.003) and u (p = 0.010) and femoral head m (p = 0.027), SD (p = 0.015), and sex (p = 0.044). CONCLUSIONS: In our experience, bone CT TA could be correlated to the risk of radiation-induced IFs. Studies on a large patient series and methodological refinements are warranted.


Asunto(s)
Fracturas por Estrés/etiología , Huesos Pélvicos/lesiones , Traumatismos por Radiación/etiología , Radioterapia de Alta Energía/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Cuello Femoral/diagnóstico por imagen , Fracturas por Estrés/diagnóstico por imagen , Humanos , Vértebras Lumbares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Huesos Pélvicos/efectos de la radiación , Neoplasias Pélvicas/radioterapia , Valor Predictivo de las Pruebas , Traumatismos por Radiación/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Dosificación Radioterapéutica , Radioterapia de Alta Energía/métodos , Medición de Riesgo/métodos , Tomografía Computarizada por Rayos X/métodos
8.
Strahlenther Onkol ; 192(5): 333-41, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26972086

RESUMEN

OBJECTIVE: The present study compares in silico treatment plans using hybrid plan technique during hypofractionated radiation of mammary carcinoma with simultaneous integrated boost (SIB). The influence of 6 MV photon radiation in flattening filter free (FFF) mode against the clinical standard flattening filter (FF) mode is to be examined. PATIENTS AND METHODS: RT planning took place with FF and FFF radiation plans for 10 left-sided breast cancer patients. Hybrid plans were realised with two tangential IMRT fields and one VMAT field. The dose prescription was in line with the guidelines in the ARO-2010-01 study. The dosimetric verification took place with a manufacturer-independent measurement system. RESULTS: Required dose prescriptions for the planning target volumes (PTV) were achieved for both groups. The average dose values of the ipsi- and contralateral lung and the heart did not differ significantly. The overall average incidental dose to the left anterior descending artery (LAD) of 8.24 ± 3.9 Gy in the FFF group and 9.05 ± 3.7 Gy in the FF group (p < 0.05) were found. The dosimetric verifications corresponded to the clinical requirements. FFF-based RT plans reduced the average treatment time by 17 s/fraction. CONCLUSION: In comparison to the FF-based hybrid plan technique the FFF mode allows further reduction of the average LAD dose for comparable target volume coverage without adverse low-dose exposure of contralateral structures. The combination of hybrid plan technique and 6 MV photon radiation in the FFF mode is suitable for use with hypofractionated dose schemes. The increased dose rate allows a substantial reduction of treatment time and thus beneficial application of the deep inspiration breath hold technique.


Asunto(s)
Neoplasias de la Mama/radioterapia , Hipofraccionamiento de la Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Alta Energía/métodos , Radioterapia de Intensidad Modulada/métodos , Terapia Combinada , Femenino , Humanos , Resultado del Tratamiento
9.
Strahlenther Onkol ; 192(4): 240-7, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26856858

RESUMEN

BACKGROUND: Combining reirradiation (reRT) and hyperthermia (HT) has shown high therapeutic value for patients with locoregional recurrent breast cancer (LR). However, additional toxicity of reirradiation (e.g., rib fractures) may occur. The aim of this study is to determine the impact of potential risk factors on the occurrence of rib fractures. PATIENTS AND METHODS: From 1982-2005, 234 patients were treated with adjuvant reRT + HT after surgery for LR. ReRT consisted typically of 8 fractions of 4 Gy twice a week, or 12 fractions of 3 Gy four times a week. A total of 118 patients were irradiated with abutted photon and electron fields. In all, 60 patients were irradiated using either one or alternating combinations of abutted AP electron fields. Hyperthermia was given once or twice a week. RESULTS: The 5-year infield local control (LC) rate was 70 %. Rib fractures were detected in 16 of 234 patients (actuarial risk: 7 % at 5 years). All rib fractures occurred in patients treated with a combination of photon and abutted electron fields (p = 0.000); in 15 of 16 patients fractures were located in the abutment regions. The other significant predictive factors for rib fractures were a higher fraction dose (p = 0.040), large RT fields, and treatment before the year 2000. DISCUSSION AND CONCLUSION: ReRT + HT results in long-term LC. The majority of rib fractures were located in the photon/electron abutment area, emphasizing the disadvantage of field overlap. Large abutted photon/electron fields combined with 4 Gy fractions increase the number of rib fractures in this study group. However, as these factors were highly correlated no relative importance of the individual factors could be estimated. Increasing the number of HT sessions a week does not increase the risk of rib fractures.


Asunto(s)
Neoplasias de la Mama/radioterapia , Hipertermia Inducida , Recurrencia Local de Neoplasia/radioterapia , Osteorradionecrosis/etiología , Traumatismos por Radiación/etiología , Radioterapia de Alta Energía/métodos , Reirradiación , Fracturas de las Costillas/etiología , Costillas/efectos de la radiación , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/patología , Terapia Combinada , Supervivencia sin Enfermedad , Femenino , Humanos , Mastectomía Segmentaria , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Radioterapia Adyuvante , Factores de Riesgo
10.
Strahlenther Onkol ; 192(4): 223-31, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26742732

RESUMEN

BACKGROUND: We compared different image-guidance (IG) strategies for prostate cancer with high-precision IG intensity-modulated radiation therapy (IMRT) using TomoTherapy® (Accuray Inc., Madison, WI, USA) and linear accelerator (LINAC)-IMRT and their impact on planning target volume (PTV) margin reduction. Follow-up data showed reduced bladder toxicity in TomoTherapy patients compared to LINAC-IMRT. The purpose of this study was to quantify whether the treatment delivery technique and decreased margins affect reductions in bladder toxicity. PATIENTS AND METHODS: Setup corrections from 30 patients treated with helical TomoTherapy and 30 treated with a LINAC were analyzed. These data were used to simulate three IG protocols based on setup error correction and a limited number of imaging sessions. For all patients, gastrointestinal (GI) and genitourinary (GU) toxicity was documented and correlated with the treatment delivery technique. RESULTS: For fiducial marker (FM)-based RT, a margin reduction of up to 3.1, 3.0, and 4.8 mm in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions, respectively, could be achieved with calculation of a setup correction from the first three fractions and IG every second day. Although the bladder volume was treated with mean doses of 35 Gy in the TomoTherapy group vs. 22 Gy in the LINAC group, we observed less GU toxicity after TomoTherapy. CONCLUSION: Intraprostate FMs allow for small safety margins, help decrease imaging frequency after setup correction, and minimize the dose to bladder and rectum, resulting in lower GU toxicity. In addition, IMRT delivered with TomoTherapy helps to avoid hotspots in the bladder neck, a critical anatomic structure associated with post-RT urinary toxicity.


Asunto(s)
Adenocarcinoma/radioterapia , Neoplasias de la Próstata/terapia , Traumatismos por Radiación/etiología , Radiocirugia/métodos , Radioterapia de Alta Energía/métodos , Radioterapia de Intensidad Modulada/métodos , Cirugía Asistida por Computador/métodos , Vejiga Urinaria/efectos de la radiación , Sistema Urogenital/efectos de la radiación , Adenocarcinoma/patología , Anciano , Anciano de 80 o más Años , Terapia Combinada , Tracto Gastrointestinal/efectos de la radiación , Humanos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica , Estadística como Asunto
11.
Strahlenther Onkol ; 192(4): 232-9, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26852243

RESUMEN

AIM: To compare simultaneous integrated boost plans for intensity-modulated proton therapy (IMPT), helical tomotherapy (HT), and RapidArc therapy (RA) for patients with head and neck cancer. PATIENTS AND METHODS: A total of 20 patients with squamous cell carcinoma of the head and neck received definitive chemoradiation with bilateral (n = 14) or unilateral (n = 6) neck irradiation and were planned using IMPT, HT, and RA with 54.4, 60.8, and 70.4 GyE/Gy in 32 fractions. Dose distributions, coverage, conformity, homogeneity to planning target volumes (PTV)s and sparing of organs at risk and normal tissue were compared. RESULTS: All unilateral and bilateral plans showed excellent PTV coverage and acceptable dose conformity. For unilateral treatment, IMPT delivered substantially lower mean doses to contralateral salivary glands (< 0.001-1.1 Gy) than both rotational techniques did (parotid gland: 6-10 Gy; submandibular gland: 15-20 Gy). Regarding the sparing of classical organs at risk for bilateral treatment, IMPT and HT were similarly excellent and RA was satisfactory. CONCLUSION: For unilateral neck irradiation, IMPT may minimize the dry mouth risk in this subgroup but showed no advantage over HT for bilateral neck treatment regarding classical organ-at-risk sparing. All methods satisfied modern standards regarding toxicity and excellent target coverage for unilateral and bilateral treatment of head and neck cancer at the planning level.


Asunto(s)
Carcinoma de Células Escamosas/radioterapia , Quimioradioterapia/métodos , Neoplasias de Oído, Nariz y Garganta/terapia , Terapia de Protones/métodos , Radioterapia de Alta Energía/métodos , Radioterapia de Intensidad Modulada/métodos , Anciano , Anciano de 80 o más Años , Carcinoma de Células Escamosas/patología , Fraccionamiento de la Dosis de Radiación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Órganos en Riesgo/efectos de la radiación , Neoplasias de Oído, Nariz y Garganta/patología , Traumatismos por Radiación/prevención & control , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos
12.
J Oral Maxillofac Surg ; 74(1): 190-9, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26253013

RESUMEN

PURPOSE: Surgery of irradiated tissue has an increased complication rate because of the development of hypovascular, hypocellular, and hypoxic tissue. This study was undertaken to perform histopathologic and histomorphometric analyses of irradiation tissue injury in bone and the surrounding soft tissues. MATERIAL AND METHODS: The histopathologic findings of 40 human mandibular bones and the surrounding soft tissue specimens obtained from different patients who underwent surgical procedures for treatment of osteoradionecrosis of the jaws were reviewed. RESULTS: Histopathologic examination showed 7 processes in the following order of appearance: hyperemia, endarteritis, thrombosis, cell loss, hypovascularity, increase of fat in the bone marrow cavity, and fibrosis. Histomorphometric analysis showed significant hypocellularity (P = .007), hypovascularity (P < .001), and fibrosis (P < .001) in irradiated specimens compared with control specimens. CONCLUSION: These results showed that radiation injuries affect the bone and surrounding soft tissues. However, the irradiation-induced injuries, such as cellular loss (hypocellularity) and fibrosis, were more expressive in bone tissue than in the surrounding soft tissues.


Asunto(s)
Enfermedades Mandibulares/patología , Osteorradionecrosis/patología , Periodoncio/efectos de la radiación , Tejido Adiposo/efectos de la radiación , Antígenos CD34/análisis , Médula Ósea/efectos de la radiación , Muerte Celular/efectos de la radiación , Endarteritis/patología , Endotelio Vascular/efectos de la radiación , Fibrosis , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Hiperemia/patología , Microvasos/efectos de la radiación , Dosificación Radioterapéutica , Radioterapia de Alta Energía/métodos , Trombosis/patología
13.
J Appl Clin Med Phys ; 17(2): 194-205, 2016 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-27074483

RESUMEN

High-dose-rate (HDR) brachytherapy is a popular modality for treating cancers of the prostate, cervix, endometrium, breast, skin, bronchus, esophagus, and head and neck as well as soft-tissue sarcomas. Because of different source designs and licensing issues, there is a need for specific dosimetry dataset for each HDR source model. The main objective of the present work is to measure 2D relative dose distribution around a new prototype 192Ir source, referred to as IRAsource-HDR, in PMMA phantom in the framework of AAPM TG-43 and TG-55 recommendations for radial distances of 0.5cm to 4 cm. Radiochromic films (RCFs) Gafchromic EBT and HD-810 were used for measurements. The dose rate constant, Λ, of the source was determined to be 1.084± 4.6%, 1.129 ± 4.4%, and 1.112 ± 0.8% cGyh-1U-1 using EBT RCF, HD-810 RCF, and Monte Carlo (MC) simulation, respectively. The results obtained in this study are in good agreement with previously published data for HDR interstitial 192Ir-HDR sources with a maximum discrepancy of ± 4.5%. An acceptable agreement (within ± 2%) between MC calculations and RCFs measurements showed that HD-810 RCF dosimetry is as good as EBT RCF, within HDR brachytherapy, and justifies the use of specific data for this new source. These data could be used as a benchmark for dose calculations in the conventional brachytherapy treatment planning systems.


Asunto(s)
Braquiterapia/instrumentación , Dosimetría por Película/métodos , Radioisótopos de Iridio/uso terapéutico , Neoplasias/radioterapia , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Alta Energía/métodos , Braquiterapia/métodos , Humanos , Método de Montecarlo , Dosificación Radioterapéutica
14.
J Appl Clin Med Phys ; 17(4): 442-455, 2016 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-27455499

RESUMEN

Out-of-field doses from radiotherapy can cause harmful side effects or eventually lead to secondary cancers. Scattered doses outside the applicator field, neutron source strength values, and neutron dose equivalents have not been broadly investigated for high-energy electron beams. To better understand the extent of these exposures, we measured out-of-field dose characteristics of electron applicators for high-energy electron beams on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at various energy levels. Out-of-field dose profiles and percent depth-dose curves were measured in a Wellhofer water phantom using a Farmer ion chamber. Neutron dose was assessed using a combination of moderator buckets and gold activation foils placed on the treatment couch at various locations in the patient plane on both the Varian 21iX and Elekta Versa HD linear accelerators. Our findings showed that out-of-field electron doses were highest for the highest electron energies. These doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. The Elekta linear accelerator had higher electron out-of-field doses than the Varian units examined, and the Elekta dose profiles exhibited a second dose peak about 20 to 30 cm from central-axis, which was found to be higher than typical out-of-field doses from photon beams. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. With respect to neutron dosimetry, Q values and neutron dose equivalents increased with electron beam energy. Neutron contamination from electron beams was found to be much lower than that from photon beams. Even though the neutron dose equivalent for electron beams represented a small portion of neutron doses observed under photon beams, neutron doses from electron beams may need to be considered for special cases.


Asunto(s)
Electrones , Neutrones , Aceleradores de Partículas , Fantasmas de Imagen , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Alta Energía/métodos , Algoritmos , Humanos , Fotones , Radiometría/instrumentación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/instrumentación , Radioterapia de Alta Energía/instrumentación , Agua
15.
J Appl Clin Med Phys ; 16(3): 5375, 2015 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-26103497

RESUMEN

Portal dosimetry using electronic portal imaging devices (EPIDs) is often applied to verify high-energy photon beam treatments. Due to the change in photon energy spectrum, the resulting dose values are, however, not very accurate in the case of wedged beams if the pixel-to-dose conversion for the situation without wedge is used. A possible solution would be to consider a wedged beam as another photon beam quality requiring separate beam modeling of the dose calculation algorithm. The aim of this study was to investigate a more practical solution: to make aSi EPID-based dosimetry models also applicable for wedged beams without an extra commissioning effort of the parameters of the model. For this purpose two energy-dependent wedge multiplication factors have been introduced to be applied for portal images taken with and without a patient/phantom in the beam. These wedge multiplication factors were derived from EPID and ionization chamber measurements at the EPID level for wedged and nonwedged beams, both with and without a polystyrene slab phantom in the beam. This method was verified for an EPID dosimetry model used for wedged beams at three photon beam energies (6, 10, and 18 MV) by comparing dose values reconstructed in a phantom with data provided by a treatment planning system (TPS), as a function of field size, depth, and off-axis distance. Generally good agreement, within 2%, was observed for depths between dose maximum and 15 cm. Applying the new model to EPID dose measurements performed during ten breast cancer patient treatments with wedged 6 MV photon beams showed that the average isocenter underdosage of 5.3% was reduced to 0.4%. Gamma-evaluation (global 3%/3 mm) of these in vivo data showed an increase in percentage of points with γ ≤ 1 from 60.2% to 87.4%, while γmean reduced from 1.01 to 0.55. It can be concluded that, for wedged beams, the multiplication of EPID pixel values with an energy-dependent correction factor provides good agreement between dose values determined by an EPID and a TPS, indicating the usefulness of such a practical solution.


Asunto(s)
Algoritmos , Radiometría/instrumentación , Radiometría/métodos , Radioterapia de Alta Energía/instrumentación , Radioterapia de Alta Energía/métodos , Pantallas Intensificadoras de Rayos X , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
J Appl Clin Med Phys ; 16(3): 5402, 2015 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-26103499

RESUMEN

Radiographic film dosimetry suffers from its energy dependence in proton dosimetry. This study sought to develop a method of measuring proton beams by the film and to evaluate film response to proton beams for the constancy check of depth dose (DD). It also evaluated the film for profile measurements. To achieve this goal, from DDs measured by film and ion chamber (IC), calibration factors (ratios of dose measured by IC to film responses) as a function of depth in a phantom were obtained. These factors imply variable slopes (with proton energy and depth) of linear characteristic curves that relate film response to dose. We derived a calibration method that enables utilization of the factors for acquisition of dose from film density measured at later dates by adapting to a potentially altered processor condition. To test this model, the characteristic curve was obtained by using EDR2 film and in-phantom film dosimetry in parallel with a 149.65 MeV proton beam, using the method. An additional validation of the model was performed by concurrent film and IC measurement perpendicular to the beam at various depths. Beam profile measurements by the film were also evaluated at the center of beam modulation. In order to interpret and ascertain the film dosimetry, Monte Carlos simulation of the beam was performed, calculating the proton fluence spectrum along depths and off-axis distances. By multiplying respective stopping powers to the spectrum, doses to film and water were calculated. The ratio of film dose to water dose was evaluated. Results are as follows. The characteristic curve proved the assumed linearity. The measured DD approached that of IC, but near the end of the spread-out Bragg peak (SOBP), a spurious peak was observed due to the mismatch of distal edge between the calibration and measurement films. The width of SOBP and the proximal edge were both reproducible within a maximum of 5mm; the distal edge was reproducible within 1 mm. At 5 cm depth, the dose was reproducible within 10%. These large discrepancies were identified to have been contributed by film processor uncertainty across a layer of film and the misalignment of film edge to the frontal phantom surface. The deviations could drop from 5 to 2 mm in SOBP and from 10% to 4.5% at 5 cm depth in a well-controlled processor condition(i.e., warm up). In addition to the validation of the calibration method done by the DD measurements, the concurrent film and IC measurement independently validated the model by showing the constancy of depth-dependent calibration factors. For profile measurement, the film showed good agreement with ion chamber measurement. In agreement with the experimental findings, computationally obtained ratio of film dose to water dose assisted understanding of the trend of the film response by revealing relatively large and small variances of the response for DD and beam profile measurements, respectively. Conclusions are as follows. For proton beams, radiographic film proved to offer accurate beam profile measurements. The adaptive calibration method proposed in this study was validated. Using the method, film dosimetry could offer reasonably accurate DD constancy checks, when provided with a well-controlled processor condition. Although the processor warming up can promote a uniform processing across a single layer of the film, the processing remains as a challenge.


Asunto(s)
Algoritmos , Dosimetría por Película/instrumentación , Dosimetría por Película/métodos , Modelos Estadísticos , Radioterapia de Alta Energía/instrumentación , Radioterapia de Alta Energía/métodos , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Protones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
J Appl Clin Med Phys ; 16(3): 5503, 2015 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-26103504

RESUMEN

Image-guided radiotherapy (IGRT), based on radiopaque markers placed in the prostate gland, was used for proton therapy of prostate patients. Orthogonal X-rays and the IBA Digital Image Positioning System (DIPS) were used for setup correction prior to treatment and were repeated after treatment delivery. Following a rationale for margin estimates similar to that of van Herk,(1) the daily post-treatment DIPS data were analyzed to determine if an adaptive radiotherapy plan was necessary. A Web application using ASP.NET MVC5, Entity Framework, and an SQL database was designed to automate this process. The designed features included state-of-the-art Web technologies, a domain model closely matching the workflow, a database-supporting concurrency and data mining, access to the DIPS database, secured user access and roles management, and graphing and analysis tools. The Model-View-Controller (MVC) paradigm allowed clean domain logic, unit testing, and extensibility. Client-side technologies, such as jQuery, jQuery Plug-ins, and Ajax, were adopted to achieve a rich user environment and fast response. Data models included patients, staff, treatment fields and records, correction vectors, DIPS images, and association logics. Data entry, analysis, workflow logics, and notifications were implemented. The system effectively modeled the clinical workflow and IGRT process.


Asunto(s)
Internet , Neoplasias de la Próstata/radioterapia , Terapia de Protones , Radioterapia Guiada por Imagen/métodos , Programas Informáticos , Flujo de Trabajo , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico , Radioterapia de Alta Energía/métodos
18.
J Appl Clin Med Phys ; 16(6): 435­448, 2015 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-26699572

RESUMEN

The purpose of this work was to experimentally investigate the out-of-field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT). The study was carried out for 6, 9, 12, and 18 MeV electron beams, on three different linear accelerators, each equipped with a specific applicator. Measurements were performed in a water phantom, at different depths, for different applicator sizes, and off-axis distances up to 70 cm from beam central axis (CAX). Thermoluminescent powder dosimeters (TLD-700) were used. For given cases, TLD measurements were compared to EBT3 films and parallel-plane ionization chamber measurements. Also, out-of-field doses at 10 cm depth, with and without applicator, were evaluated. With the Siemens applicators, a peak dose appears at about 12-15 cm out of the field edge, at 1 cm depth, for all field sizes and energies. For the Siemens Primus, with a 10 × 10 cm(²) applicator, this peak reaches 2.3%, 1%, 0.9% and 1.3% of the maximum central axis dose (Dmax) for 6, 9, 12 and 18 MeV electron beams, respectively. For the Siemens Oncor, with a 10 × 10 cm(²) applicator, this peak dose reaches 0.8%, 1%, 1.4%, and 1.6% of Dmax for 6, 9, 12, and 14 MeV, respectively, and these values increase with applicator size. For the Varian 2300C/D, the doses at 12.5 cm out of the field edge are 0.3%, 0.6%, 0.5%, and 1.1% of Dmax for 6, 9, 12, and 18 MeV, respectively, and increase with applicator size. No peak dose is evidenced for the Varian applicator for these energies. In summary, the out-of-field dose from electron beams increases with the beam energy and the applicator size, and decreases with the distance from the beam central axis and the depth in water. It also considerably depends on the applicator types. Our results can be of interest for the dose estimations delivered in healthy tissues outside the treatment field for the RT patient, as well as in studies exploring RT long-term effects.


Asunto(s)
Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Alta Energía/métodos , Electrones/uso terapéutico , Diseño de Equipo , Dosimetría por Película , Humanos , Aceleradores de Partículas , Fantasmas de Imagen , Radiometría/instrumentación , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos , Radioterapia de Alta Energía/instrumentación , Radioterapia de Alta Energía/estadística & datos numéricos , Dosimetría Termoluminiscente , Agua
19.
J Appl Clin Med Phys ; 16(6): 314-324, 2015 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-26699586

RESUMEN

The accurate measurement of the linear accelerator (linac) radiation isocenter is critical, especially for stereotactic treatment. Traditional quality assurance (QA) procedure focuses on the measurement of single radiation isocenter, usually of 6 megavoltage (MV) photon beams. Single radiation isocenter is also commonly assumed in treatment planning systems (TPS). Due to different flattening filters and bending magnet and steering parameters, the radiation isocenter of one energy mode can deviate from another if no special effort was devoted. We present the first experience of the multiradiation isocenters alignment on an Elekta linac, as well as its corresponding QA procedure and clinical impact. An 8 mm ball-bearing (BB) phantom was placed at the 6 MV radiation isocenter using an Elekta isocenter search algorithm, based on portal images. The 3D radiation isocenter shifts of other photon energy modes relative to the 6 MV were determined. Beam profile scanning for different field sizes was used as an independent method to determine the 2D multiradiation isocenters alignment. To quantify the impact of radiation isocenter offset on targeting accuracy, the 10 MV radiation isocenter was manually offset from that for 6 MV by adjusting the bending magnet current. Because our table isocenter was mechanically aligned to the 6 MV radiation isocenter, the deviation of the table isocentric rotation from the "shifted" 10 MV radiation isocenter after bending magnet adjustment was assessed. Winston-Lutz test was also performed to confirm the overall radiation isocenter positioning accuracy for all photon energies. The portal image method showed the radiation isocenter of the 10 MV flattening filter-free mode deviated from others before beam parameter adjustment. After the adjustment, the deviation was greatly improved from 0.96 to 0.35 mm relative to the 6 MV radiation isocenter. The same finding was confirmed by the profile-scanning method. The maximum deviation of the table isocentric rotation from the 10 MV radiation isocenter was observed to linearly increase with the offset between 6 and 10 MV radiation isocenter; 1 mm radiation isocenter offset can translate to almost 2 mm maximum deviation of the table isocentric rotation from the 10 MV radiation isocenter. The alignment of the multiradiation isocenters is particularly important for high-precision radiotherapy. Our study provides the medical physics community with a quantitative measure of the multiradiation isocenters alignment. A routine QA method should be considered, to examine the radiation isocenters alignment during the linac acceptance.


Asunto(s)
Fotones/uso terapéutico , Radioterapia de Alta Energía/métodos , Algoritmos , Humanos , Imagenología Tridimensional , Aceleradores de Partículas , Posicionamiento del Paciente , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud , Planificación de la Radioterapia Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/normas , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos , Radioterapia de Alta Energía/normas , Radioterapia de Alta Energía/estadística & datos numéricos , Rotación
20.
Int Dent J ; 65(5): 242-8, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26362241

RESUMEN

AIM OF THE STUDY: Radiotherapy (RT) is a radical therapeutic option for patients with oropharyngeal cancer (OPC). It induces an acute postradiation reaction that may cause significant pain. The aim of this study was to analyse pain occurrence and intensity, as well as type and effectiveness of analgesic treatment, in OPC patients undergoing RT or radiochemotherapy (RT-CT). MATERIAL AND METHODS: Retrospective data were obtained for 42 OPC patients at clinical stages I-IVA, treated with adjuvant RT or RT-CT or definite RT or RT-CcT at the Comprehensive Cancer Center in Bialystok, Poland. Pain intensity and type of analgesic treatment during the therapy were analysed and compared with the intensity of the radiation-induced acute reaction, assessed weekly according to the Dische score. RESULTS: Thirty-nine (92.9%) patients received analgesic treatment. Analgesic therapy was started in 27 (64.3%) patients with administration of non-steroidal anti-inflammatory drugs (NSAIDs) and/or paracetamol, in seven (16.7%) with mild opioids and in five (11.9%) with strong opioids. Strong opioids were used during therapy in 21 (50%) patients. Co-analgesics were administered to six patients. Breakthrough pain was observed in 10 (23.8%) patients. CONCLUSIONS: High incidence of pain during RT and RT-CT calls for increased awareness of the importance of pain monitoring and treatment during RT of OPC patients. The analgesic treatment had to be adjusted individually.


Asunto(s)
Neoplasias Orofaríngeas/radioterapia , Manejo del Dolor/métodos , Acetaminofén/uso terapéutico , Adulto , Anciano , Analgésicos/uso terapéutico , Analgésicos Opioides/uso terapéutico , Antiinflamatorios no Esteroideos/uso terapéutico , Antineoplásicos/uso terapéutico , Quimioradioterapia/métodos , Quimioradioterapia Adyuvante , Cisplatino/uso terapéutico , Dipirona/uso terapéutico , Combinación de Medicamentos , Femenino , Fentanilo/uso terapéutico , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Morfina/uso terapéutico , Estadificación de Neoplasias , Neoplasias Orofaríngeas/terapia , Dolor/clasificación , Radioterapia Adyuvante , Radioterapia de Alta Energía/métodos , Estudios Retrospectivos , Tramadol/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA