Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Anal Chem ; 87(16): 8473-80, 2015 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-26167627

RESUMEN

The development of rapid methods for unambiguous identification and precise quantification of protein toxins in various matrices is essential for public health surveillance. Nowadays, analytical strategies classically rely on sensitive immunological assays, but mass spectrometry constitutes an attractive complementary approach thanks to direct measurement and protein characterization ability. We developed here an innovative multiplex immuno-LC-MS/MS method for the simultaneous and specific quantification of the three potential biological warfare agents, ricin, staphylococcal enterotoxin B, and epsilon toxin, in complex human biofluids and food matrices. At least 7 peptides were targeted for each toxin (43 peptides in total) with a quadrupole-Orbitrap high-resolution instrument for exquisite detection specificity. Quantification was performed using stable isotope-labeled toxin standards spiked early in the sample. Lower limits of quantification were determined at or close to 1 ng·mL(-1). The whole process was successfully applied to the quantitative analysis of toxins in complex samples such as milk, human urine, and plasma. Finally, we report new data on toxin stability with no evidence of toxin degradation in milk in a 48 h time frame, allowing relevant quantitative toxin analysis for samples collected in this time range.


Asunto(s)
Enterotoxinas/análisis , Ricina/análisis , Espectrometría de Masas en Tándem , Secuencia de Aminoácidos , Animales , Isótopos de Carbono/química , Cromatografía Líquida de Alta Presión , Enterotoxinas/sangre , Enterotoxinas/orina , Humanos , Marcaje Isotópico , Leche/química , Isótopos de Nitrógeno/química , Péptidos/análisis , Péptidos/normas , Ricina/sangre , Ricina/orina , Espectrometría de Masas en Tándem/normas
2.
Anal Bioanal Chem ; 406(21): 5147-55, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24633508

RESUMEN

Ricin is a toxic protein derived from castor beans and composed of a cytotoxic A chain and a galactose-binding B chain linked by a disulfide bond, which can inhibit protein synthesis and cause cell death. Owing to its high toxicity, ease of preparation, and lack of medical countermeasures, ricin has been listed as both chemical and biological warfare agents. For homeland security or public safety, the unambiguous, sensitive, and rapid methods for identification and quantification of ricin in complicated matrices are of urgent need. Mass spectrometric analysis, which provides specific and sensitive characterization of protein, can be applied to confirm and quantify ricin. Here, we report a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method in which ricin was extracted and enriched from serum by immunocapture using anti-ricin monoclonal antibody 3D74 linked to magnetic beads, then digested by trypsin, and analyzed by LC-ESI-MS/MS. Among 19 distinct peptides observed in LC-quadrupole/time of flight-MS (LC-QTOF-MS), two specific and sensitive peptides, T7A ((49)VGLPINQR(56)) and T14B ((188)DNCLTSDSNIR(198)), were chosen, and a highly sensitive determination of ricin was established in LC-triple quadrupole-MS (LC-QqQ-MS) operating in multiple reaction monitoring mode. These specific peptides can definitely distinguish ricin from the homologous protein Ricinus communis agglutinin (RCA120), even though the amino acid sequence homology of the A-chain of ricin and RCA120 is up to ca. 93% and that of B-chain is ca. 85%. Furthermore, peptide T7A was preferred in the quantification of ricin because its sensitivity was at least one order of magnitude higher than that of the peptide T14B. Combined with immunocapture enrichment, this method provided a limit of detection of ca. 2.5 ng/mL and the limit of quantification was ca. 5 ng/mL of ricin in serum, respectively. Both precision and accuracy of this method were determined and the RSD was less than 15%. This established method was then applied to measure ricin in serum samples collected from rats exposed to ricin at the dosage of 50 µg/kg in an intravenous injection manner. The results showed that ca. 10 ng/mL of the residual ricin in poisoned rats serum could be detected even at 12 h after exposure.


Asunto(s)
Anticuerpos Monoclonales/química , Armas Biológicas , Sustancias para la Guerra Química/aislamiento & purificación , Fragmentos de Péptidos/análisis , Ricina/sangre , Animales , Cromatografía Liquida , Inmunoprecipitación , Límite de Detección , Imanes , Masculino , Lectinas de Plantas/análisis , Ratas , Ratas Sprague-Dawley , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Tripsina/química
3.
Anal Bioanal Chem ; 406(21): 5157-69, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24928113

RESUMEN

Ricin is a toxin that can be easily extracted from seeds of Ricinus communis plants. Ricin is considered to be a major bio-threat as it can be freely and easily acquired in large quantities. A deliberate release of such toxin in civilian populations would very likely overwhelm existing public health systems, resulting in public fear and social unrest. There is currently no commercially available or FDA-approved prophylaxis such as vaccines, or therapeutic antitoxins or antidotes, available for ricin intoxication. Patient treatment is typically supportive care based on symptoms, often designed to reinforce the body's natural response. This paper describes the development and validation of a robust ELISA test kit, which can be used to screen for ricin in biological specimens such as whole blood and faeces. Faecal specimens are shown in this study to have better diagnostic sensitivity and a wider diagnostic window compared to whole blood. From these results, it is concluded that faeces is the most suitable clinical specimen for diagnosis of ricin poisoning via the oral route. The ELISA test kit can also detect ricin in environmental samples. An advantage of this ELISA kit over other commercial off-the-shelf (COTS) detection kits currently on the market that are developed to screen environmental samples only is its ability to diagnose ricin poisoning from clinical specimens as well as detect ricin from environmental samples.


Asunto(s)
Anticuerpos Monoclonales/química , Armas Biológicas , Sustancias para la Guerra Química/aislamiento & purificación , Ensayo de Inmunoadsorción Enzimática/normas , Juego de Reactivos para Diagnóstico/normas , Ricina/sangre , Animales , Heces/química , Humanos , Límite de Detección , Masculino , Variaciones Dependientes del Observador , Conejos , Ratas , Ratas Wistar , Reproducibilidad de los Resultados
4.
Toxins (Basel) ; 13(2)2021 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-33499033

RESUMEN

Ricin, a protein derived from the seeds of the castor bean plant (Ricinus communis), is a highly lethal toxin that inhibits protein synthesis, resulting in cell death. The widespread availability of ricin, its ease of extraction and its extreme toxicity make it an ideal agent for bioterrorism and self-poisoning. Thus, a rapid, sensitive and reliable method for ricin identification in clinical samples is required for applying appropriate and timely medical intervention. However, this goal is challenging due to the low predicted toxin concentrations in bio-fluids, accompanied by significantly high matrix interferences. Here we report the applicability of a sensitive, selective, rapid, simple and antibody-independent assay for the identification of ricin in body fluids using mass spectrometry (MS). The assay involves lectin affinity capturing of ricin by easy-to-use commercial lactose-agarose (LA) beads, following by tryptic digestion and selected marker identification using targeted LC-MS/MS (Multiple Reaction Monitoring) analysis. This enables ricin identification down to 5 ng/mL in serum samples in 2.5 h. To validate the assay, twenty-four diverse naive- or ricin-spiked serum samples were evaluated, and both precision and accuracy were determined. A real-life test of the assay was successfully executed in a challenging clinical scenario, where the toxin was identified in an abdominal fluid sample taken 72 h post self-injection of castor beans extraction in an eventual suicide case. This demonstrates both the high sensitivity of this assay and the extended identification time window, compared to similar events that were previously documented. This method developed for ricin identification in clinical samples has the potential to be applied to the identification of other lectin toxins.


Asunto(s)
Cromatografía Liquida , Ricina , Espectrometría de Masas en Tándem , Humanos , Biomarcadores/sangre , Límite de Detección , Reproducibilidad de los Resultados , Ricina/sangre , Ricina/envenenamiento , Factores de Tiempo , Flujo de Trabajo
5.
Anal Biochem ; 401(2): 271-9, 2010 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-20226158

RESUMEN

Using a newly developed fluorescent nanoparticle (NP) that gives rise to a high-intensity and stable fluorescent light, a sensitive antibody (Ab) microarray assay system has been developed for specific detection of bioterrorism agents, as exemplified by ricin, cholera toxin (CT), and staphylococcal enterotoxin B (SEB). The Ab microarray uses a sandwich format that consists of capture Abs, analytes (toxins), biotinylated detection Abs, and avidin-conjugated NP. In all three cases, polyclonal Abs (pAbs) displayed superiority over monoclonal antibodies (mAbs) in capturing toxins on microarray slides even when the pAbs and mAbs had similar affinity as determined by enzyme-linked immunosorbent assay (ELISA). The detection system was successfully used to detect toxins spiked in milk, apple cider, and blood samples. We were able to detect ricin at 100 pg/ml in buffer and at 1 ng/ml in spiked apple cider or milk, whereas CT and SEB were detected at 10 pg/ml in buffer and 100 pg/ml in spiked apple cider or milk. High specificities were also demonstrated in the detection of mixed toxin samples with similar sensitivities. The matrix effect of blood samples on the detection of mixed toxins seems to be minimal when the toxin concentration is at or above 100 ng/ml. The current study highlights the significant role of pAb and NP in increasing selectivity and sensitivity of toxin detection in a microarray format.


Asunto(s)
Anticuerpos/inmunología , Sustancias para la Guerra Química/análisis , Toxina del Cólera/análisis , Enterotoxinas/análisis , Análisis por Matrices de Proteínas/métodos , Ricina/análisis , Animales , Bebidas/análisis , Toxina del Cólera/sangre , Toxina del Cólera/inmunología , Enterotoxinas/sangre , Enterotoxinas/inmunología , Colorantes Fluorescentes/química , Humanos , Leche/química , Nanopartículas/química , Ricina/sangre , Ricina/inmunología , Sensibilidad y Especificidad
6.
Anal Chem ; 81(6): 2037-42, 2009 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-19228034

RESUMEN

Ricin is a potent toxin capable of inhibiting protein synthesis and causing death or respiratory failure. Because of its high availability and lethality, ricin is considered a likely agent for bioterrorism. Rapidly determining contamination of food product with ricin and human exposure to ricin is therefore an important public health goal. In this work, we report the development of a method that detects ricin and its activity in food or clinical samples. This method involves immunocapture of the toxin, an examination of the activity of the ricin protein upon a DNA substrate that mimics the toxin's natural RNA target, and analysis of tryptic fragments of the toxin itself. It is the combination of these three techniques, all performed on the same sample, which allows for a sensitive and selective analysis of ricin isolated from a food or clinical sample. This measurement includes a measure of the toxin's activity. The utility of this method was demonstrated on ricin spiked into food and clinical samples consisting of milk, apple juice, serum, and saliva.


Asunto(s)
Sustancias para la Guerra Química/análisis , Contaminación de Alimentos/análisis , Ricina/análisis , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Secuencia de Aminoácidos , Animales , Bebidas/análisis , ADN/química , Humanos , Leche/química , Datos de Secuencia Molecular , Ricina/sangre , Saliva/metabolismo , Tripsina/metabolismo
7.
Toxicology ; 223(1-2): 61-70, 2006 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-16650517

RESUMEN

A previously characterised amplified ELISA for ricin (sensitivity limit approximately 200 pgmL(-1)) has been employed to quantify ricin following a novel recovery method from selected tissues. Tissue samples from rats dosed by pulmonary instillation or orally with ricin were homogenised and treated with an elution buffer to extract ricin. This is the first time that ex vivo recovery of ricin post exposure following pulmonary or oral challenge has been achieved using clinically acceptable sampling methods, with promise in terms of diagnosis for the timely implementation of therapy. The toxin was detected and quantified using the ELISA in conjunction with pure ricin standards. Extracts from tissues sampled, including lung, blood, liver and spleen tested positive for ricin with maximum yield in lung associated fractions for pulmonary dosing and liver tissue for oral administration. This indicates the potential of lavage and blood sampling for timely diagnosis of ricin poisoning by pulmonary and oral routes, respectively. Time course analysis at 24 and 48 h also indicated the progression of ricin from surfaces of the lung into the lung tissue. Inter-subject variation was observed in the case of oral dosing, with data for ricin-treated and vehicle control tissues not statistically different in all samples. In addition the oral toxicity of the crude ricin administered was found to be higher than expected in the rat, based upon published information and an unpublished in house murine study.


Asunto(s)
Sustancias para la Guerra Química/análisis , Ricina/análisis , Administración Oral , Animales , Sustancias para la Guerra Química/farmacocinética , Sustancias para la Guerra Química/envenenamiento , Electroforesis en Gel de Poliacrilamida , Exposición por Inhalación , Dosificación Letal Mediana , Hígado/metabolismo , Pulmón/metabolismo , Masculino , Especificidad de Órganos , Intoxicación/sangre , Intoxicación/diagnóstico , Ratas , Ratas Sprague-Dawley , Ricina/sangre , Ricina/farmacocinética , Ricina/envenenamiento , Sensibilidad y Especificidad , Bazo/metabolismo , Factores de Tiempo , Distribución Tisular
8.
Cancer Res ; 44(2): 862-5, 1984 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-6692385

RESUMEN

A Phase I study was carried out with ricin, a plant toxin acting by inhibiting protein synthesis, on 54 cancer patients with advanced disease. Ricin was given as i.v. bolus injections every two weeks at dose levels ranging from 4.5 to 23 micrograms/sq m of estimated body surface area. Ricin was well tolerated at doses up to 18 to 20 micrograms/sq m. At these levels and at higher levels, flu-like symptoms with fatigue and muscular pain appeared and, in some patients, nausea and vomiting occurred also. No myelo-suppression was seen. Antibodies to ricin were detected in serum after two to three ricin injections. Ricin was eliminated from blood according to first order kinetics. At each dose level, the plasma concentrations, as well as the side effects, showed only minor differences between patients. The highest dose given, 23 micrograms/sq m, gave plasma concentrations twice those found previously to be therapeutically effective in tumor-bearing mice. Of 38 evaluable patients, one patient with lymphoma had a partial response. Stable disease was observed in four patients with renal cancers, in two with soft tissue sarcomas, and in one patient each with mesothelioma, thyroid, and rectal cancer. A dose of 23 micrograms/sq m is recommended for Phase II trials of ricin.


Asunto(s)
Neoplasias/tratamiento farmacológico , Ricina/uso terapéutico , Abrina/uso terapéutico , Adolescente , Adulto , Anciano , Formación de Anticuerpos , Evaluación de Medicamentos , Femenino , Semivida , Humanos , Linfoma/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Ricina/efectos adversos , Ricina/sangre
9.
J Am Soc Mass Spectrom ; 27(4): 748-51, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26873724

RESUMEN

The protein toxin ricin obtained from castor bean plant (Ricinus communis) seeds is a potent biological warfare agent due to its ease of availability and acute toxicity. In this study, we demonstrated a rapid and simple method to detect ricin in serum in vitro. The ricin was mixed with serum and digested by trypsin, then all the peptides were efficiently extracted using Cu-chelated magnetic beads and were detected with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. The specific ricin peptides were identified by Nanoscale Ultra Performance liquid chromatography coupled to tandem mass spectrometry according to their sequences. The assay required 2.5 hours, and a characteristic peptide could be detected down to 4 ng/µl and used as a biomarker to detect ricin in serum. The high sensitivity and simplicity of the procedure makes it valuable in clinical practice. Graphical Abstract ᅟ.


Asunto(s)
Quelantes/química , Sustancias para la Guerra Química/farmacocinética , Cobre/química , Imanes/química , Ricina/sangre , Secuencia de Aminoácidos , Sustancias para la Guerra Química/análisis , Cromatografía Líquida de Alta Presión/métodos , Humanos , Límite de Detección , Reproducibilidad de los Resultados , Ricina/análisis , Ricinus/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
10.
J Clin Oncol ; 15(2): 723-34, 1997 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-9053498

RESUMEN

PURPOSE: Immunotoxins could improve outcome in small-cell lung cancer (SCLC) by targeting tumor cells that are resistant to chemotherapy and radiation. N901 is a murine monoclonal antibody that binds to the CD56 (neural cell adhesion molecule [NCAM]) antigen found on cells of neuroendocrine origin, including SCLC. N901-bR is an immunoconjugate of N901 antibody with blocked ricin (bR) as the cytotoxic effector moiety. N901-bR has more than 700-fold greater selectivity in vitro for killing the CD56+ SCLC cell line SW-2 than for an antigen-negative lymphoma cell line. Preclinical studies suggested the potential for clinically significant cardiac and neurologic toxicity. We present a phase I study of N901-bR in relapsed SCLC. PATIENTS AND METHODS: Twenty-one patients (18 relapsed, three primary refractory) with SCLC were entered onto this study. Successive cohorts of at least three patients were treated at doses from 5 to 40 microg/kg/d for 7 days. The initial three cohorts received the first day's dose (one seventh of planned dose) as a bolus infusion before they began the continuous infusion on the second day to observe acute toxicity and determine bolus pharmacokinetics. Toxicity assessment included nerve-conduction studies (NCS) and radionuclide assessment of left ventricular ejection fraction (LVEF) before and after N901-bR administration to fully assess potential neurologic and cardiac toxicity. RESULTS: The dose-limiting toxicity (DLT) of N901-bR given by 7-day continuous infusion is capillary leak syndrome, which occurred in two of three patients at the dose of 40 microg/kg (lean body weight [LBW])/d. Detectable serum drug levels equivalent to effective in vitro drug levels were achieved at the 20-, 30-, and 40-microg/kg(LBW)/d dose levels. Specific binding of the immunotoxin to tumor cells in bone marrow, liver, and lung was observed. Cardiac function remained normal in 15 of 16 patients. No patient developed clinically significant neuropathy. However, a trend was noted for amplitude decline in serial NCS of both sensory and motor neurons. One patient with refractory SCLC achieved a partial response. CONCLUSION: N901-bR is an immunotoxin with potential clinical activity in SCLC. N901-bR is well tolerated when given by 7-day continuous infusion at the dose of 30 microg/kg(LBW)/d. Neurologic and cardiac toxicity were acceptable when given to patients with refractory SCLC. A second study to evaluate this agent after induction chemoradiotherapy in both limited- and extensive-stage disease was started following completion of this study.


Asunto(s)
Anticuerpos Monoclonales/uso terapéutico , Carcinoma de Células Pequeñas/terapia , Inmunotoxinas/uso terapéutico , Neoplasias Pulmonares/terapia , Ricina/análogos & derivados , Adulto , Anciano , Anticuerpos Monoclonales/efectos adversos , Anticuerpos Monoclonales/sangre , Carcinoma de Células Pequeñas/inmunología , Femenino , Corazón/efectos de los fármacos , Humanos , Inmunoconjugados , Inmunotoxinas/efectos adversos , Inmunotoxinas/sangre , Neoplasias Pulmonares/inmunología , Masculino , Persona de Mediana Edad , Sistema Nervioso/efectos de los fármacos , Ricina/efectos adversos , Ricina/sangre , Ricina/uso terapéutico , Resultado del Tratamiento
11.
Chem Commun (Camb) ; 51(82): 15137-40, 2015 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-26323568

RESUMEN

Protein toxins present considerable health risks, but detection often requires laborious analysis. Here, we developed electrochemical aptamer biosensors for ricin and botulinum neurotoxins, which display robust and specific signal at nanomolar concentrations and function in dilute serum. These biosensors may aid future efforts for the rapid diagnosis of toxins.


Asunto(s)
Aptámeros de Nucleótidos/química , Técnicas Biosensibles , Toxinas Botulínicas Tipo A/análisis , ADN/química , Ricina/análisis , Animales , Toxinas Botulínicas Tipo A/sangre , Bovinos , Electroquímica , Conformación de Ácido Nucleico , Ricina/sangre
12.
Cancer Chemother Pharmacol ; 13(3): 157-63, 1984.
Artículo en Inglés | MEDLINE | ID: mdl-6488437

RESUMEN

A highly sensitive enzyme-linked immunosorbent assay (ELISA) for determination of ricin in serum is presented. Using this method it was found that IV-injected ricin disappeared from the plasma of mice and cancer patients according to first-order kinetics. DBA mice were found to be more sensitive to ricin than C3H and B6D2 mice. When mice of the different strains were given the same dose of ricin, the concentrations found in liver, spleen, and kidneys were highest in the most sensitive mice. Ricin disappeared most rapidly from serum of the mice with the highest sensitivity. The inverse correlation between the rate of disappearance of ricin from serum and the tissue concentrations reached may be due to the fact that ricin is rapidly and firmly bound to cell surface receptors. Whole-body autoradiography after IV injection of 125I-labeled ricin showed the highest amount of radioactivity in liver, spleen, and adrenal cortex. Considerable amounts of radioactivity were also present in bone marrow, showing that the lack of myelosuppressive activity of ricin previously found in mice and dogs cannot be accounted for by the failure of ricin to reach the bone marrow. Part of the ricin in the tissues was present in the form of free chains, the highest fraction being present in the liver. In this tissue both the free A-chains and those present in whole ricin were found to be modified. However, the modified A-chains had retained their full capacity to inhibit protein synthesis in vitro. In cancer patients, toxicity appeared at about the same initial serum levels as in the mice, supporting the view that mouse data have a good predictive value for man. At each dose level the individual variations were modest, a finding that is important for eventual clinical use of this potent drug.


Asunto(s)
Ricina/metabolismo , Animales , Ensayo de Inmunoadsorción Enzimática , Humanos , Cinética , Tasa de Depuración Metabólica , Ratones , Ratones Endogámicos/metabolismo , Peso Molecular , Ricina/administración & dosificación , Ricina/sangre , Ricina/inmunología , Especificidad de la Especie , Distribución Tisular
13.
Toxicon ; 32(11): 1371-7, 1994 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-7886695

RESUMEN

A highly sensitive and specific ELISA was developed to detect ricin in biological fluids. The assay utilizes an affinity-purified goat polyclonal antibody to adsorb ricin from solution. The same antibody (biotinylated) is then used to form a sandwich, and avidin-linked alkaline phosphatase allows color development and measurement of optical density at 405 nm. Our routine assay uses a standard curve over the range of 0-10 ng/ml ricin, with accurate quantitation below 1 ng/ml (100 pg/well) in assay buffer as well as in a 1:10 dilution of human urine or 1:50 dilution of human serum spiked with ricin. Ricin measured in spiked samples demonstrated accuracy typically within 5% of the expected value in all matrices. The coefficient of variation ranged from 3-10% at 10 ng/ml to 8-25% at 2.5 ng/ml. Two variations on the routine assay were also investigated. First, lengthened incubation times and additional time for color development allowed accurate quantitation in serum dilutions as low as 1:2. Second, increased concentrations of biotinylated antibody and avidin-linked enzyme from 1:250 to 1:70 enhanced the sensitivity of the assay 10-fold, achieving a detection limit of at least 100 pg/ml (10 pg/well). The assay was also configured to a format based upon chemiluminescence, which allowed quantitation in the 0.1-1 ng/ml range, but was subject to slightly greater variability than the colorimetric assay.


Asunto(s)
Ensayo de Inmunoadsorción Enzimática , Ricina/análisis , Animales , Anticuerpos/química , Cromatografía de Afinidad , Colorimetría , Cabras , Humanos , Mediciones Luminiscentes , Estándares de Referencia , Reproducibilidad de los Resultados , Ricina/sangre , Ricina/inmunología , Ricina/orina
14.
Presse Med ; 14(37): 1909-13, 1985 Nov 02.
Artículo en Francés | MEDLINE | ID: mdl-2933692

RESUMEN

In order to consolidate a complete or partial remission, 4 patients with T-cell malignancy received cyclophosphamide 120 mg/kg plus total body irradiation, followed by reinfusion of cryopreserved autologous bone marrow purged in vitro by the immunotoxin T 101 (SR 41322) composed of the murine monoclonal T 101 antibody coupled with the A chain of ricin. The immunotoxin was applied in doses of 10(-9) and 10(-8) M for periods of 4 and 20 hours at 37 degrees C. The recovery of CFUc and BFUe progenitors was total following incubation with IT 101, but reduced after cryopreservation (1-15 to 80% for CFUc,-33 to 47% for BFUe), haematopoietic recovery occurred within normal delays, demonstrating that autologous bone marrow pretreated with the immunotoxin can be successfully transplanted. However, the slow increase in lymphocytes and the occurrence of lethal infection in 2 cases indicate that an in-depth study of immunological reconstitution after in vitro treatment of bone marrow with ITT 101 is necessary.


Asunto(s)
Anticuerpos Monoclonales/farmacología , Trasplante de Médula Ósea , Refuerzo Inmunológico de Injertos/métodos , Leucemia Linfoide/cirugía , Linfoma/cirugía , Ricina/farmacología , Adolescente , Adulto , Anticuerpos Monoclonales/efectos adversos , Anticuerpos Monoclonales/sangre , Médula Ósea/efectos de los fármacos , Estudios de Evaluación como Asunto , Femenino , Humanos , Masculino , Ricina/efectos adversos , Ricina/sangre , Linfocitos T , Factores de Tiempo
15.
Toxins (Basel) ; 3(9): 1131-45, 2011 09.
Artículo en Inglés | MEDLINE | ID: mdl-22069759

RESUMEN

The entry of ricin toxin into macrophages and certain other cell types in the spleen and liver results in toxin-induced inflammation, tissue damage and organ failure. It has been proposed that uptake of ricin into macrophages is facilitated by the mannose receptor (MR; CD206), a C-type lectin known to recognize the oligosaccharide side chains on ricin's A (RTA) and B (RTB) subunits. In this study, we confirmed that the MR does indeed promote ricin binding, uptake and killing of monocytes in vitro. To assess the role of MR in the pathogenesis of ricin in vivo, MR knockout (MR(-/-)) mice were challenged with the equivalent of 2.5× or 5× LD(50) of ricin by intraperitoneal injection. We found that MR(-/-) mice were significantly more susceptible to toxin-induced death than their age-matched, wild-type control counterparts. These data are consistent with a role for the MR in scavenging and degradation of ricin, not facilitating its uptake and toxicity in vivo.


Asunto(s)
Inmunidad Innata/efectos de los fármacos , Lectinas Tipo C/fisiología , Lectinas de Unión a Manosa/fisiología , Receptores de Superficie Celular/fisiología , Ricina/toxicidad , Animales , Apoptosis/efectos de los fármacos , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Citocinas/inmunología , Femenino , Humanos , Leucocitos/efectos de los fármacos , Macrófagos/efectos de los fármacos , Masculino , Receptor de Manosa , Ratones , Ratones Noqueados , Ricina/sangre , Ricina/farmacocinética
16.
PLoS One ; 5(9): e12858, 2010 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-20877567

RESUMEN

BACKGROUND: Ricin (also called RCA-II or RCA(60)), one of the most potent toxins and documented bioweapons, is derived from castor beans of Ricinus communis. Several in vitro methods have been designed for ricin detection in complex food matrices in the event of intentional contamination. Recently, a novel Immuno-PCR (IPCR) assay was developed with a limit of detection of 10 fg/ml in a buffer matrix and about 10-1000-fold greater sensitivity than other methods in various food matrices. METHODS AND FINDINGS: In order to devise a better diagnostic test for ricin, the IPCR assay was adapted for the detection of ricin in biological samples collected from mice after intoxication. The limit of detection in both mouse sera and feces was as low as 1 pg/ml. Using the mouse intravenous (iv) model for ricin intoxication, a biphasic half-life of ricin, with a rapid t(1/2)α of 4 min and a slower t(1/2)ß of 86 min were observed. The molecular biodistribution time for ricin following oral ingestion was estimated using an antibody neutralization assay. Ricin was detected in the blood stream starting at approximately 6-7 h post- oral intoxication. Whole animal histopathological analysis was performed on mice treated orally or systemically with ricin. Severe lesions were observed in the pancreas, spleen and intestinal mesenteric lymph nodes, but no severe pathology in other major organs was observed. CONCLUSIONS: The determination of in vivo toxicokinetics and pathological effects of ricin following systemic and oral intoxication provide a better understanding of the etiology of intoxication and will help in the future design of more effective diagnostic and therapeutic methods.


Asunto(s)
Heces/química , Inmunoensayo/métodos , Reacción en Cadena de la Polimerasa/métodos , Ricina/análisis , Ricina/toxicidad , Animales , Ricinus communis/química , Femenino , Ratones , Distribución Aleatoria , Ricina/sangre , Ricina/farmacocinética , Sensibilidad y Especificidad , Distribución Tisular
18.
J Toxicol Environ Health ; 8(3): 409-17, 1981 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-7345165

RESUMEN

Radioimmunoassays for abrin and ricin are described. There is little cross-reactivity between the two toxins. The procedures described are capable of determining blood concentrations down to 50-100 pg/ml, permitting identification of abrin and ricin poisoning and monitoring of the blood concentrations in cancer patients treated with these agents.


Asunto(s)
Abrina/sangre , Proteínas de Plantas/sangre , Ricina/sangre , Reacciones Cruzadas , Humanos , Radioinmunoensayo
19.
Hum Toxicol ; 2(2): 239-42, 1983 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-6862467

RESUMEN

1 A 21-year-old student ingested thirty ricin seeds in a suicidal attempt, some of which were masticated. Three hours later he developed severe diarrhoea with vomiting and abdominal cramps, followed by extracellular dehydration and circulatory collapse. 2 Biological changes included haemoconcentration. He recovered following symptomatic treatment by infusion of saline and glucose solutions. 3 Ricin was quantified by a radioimmunologic method using Iodine 125, and showed that only a small part of the ricin contained in the seeds was absorbed.


Asunto(s)
Ricina/envenenamiento , Adulto , Humanos , Masculino , Lectinas de Plantas , Plantas Tóxicas , Radioinmunoensayo , Ricina/sangre , Ricina/orina , Ricinus , Semillas , Intento de Suicidio
20.
Eur J Biochem ; 155(1): 1-10, 1986 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-3948873

RESUMEN

In recent years, antibody--ricin-A-chain immunotoxins have been investigated as anti-neoplastic agents. To achieve in vivo therapy it is necessary that the immunotoxin remains in circulation at a sufficiently high level for a sufficiently long time to allow binding to tumor cells to occur. Therefore, examination of the pharmacology of immunotoxins may elucidate the reasons for the poor in vivo tumoricidal effect of immunotoxin described before. In this study the plasma clearance of antibody--ricin-A-chain immunotoxins, after intravenous injection in animals of different species, has been examined. Sensitive and reproducible techniques were developed to monitor the level of immunotoxin and its constituents in the blood. It is shown that immunotoxins are rapidly eliminated from the bloodstream. Neither the properties of the antibody moiety nor the nature of the linkage binding ricin A-chain to antibody account for the disappearance of immunotoxin from the plasma. On the other hand, we found that the rapid clearance of immunotoxin is due to the mannose residues on the ricin A-chain moiety which are specifically recognized by liver cells. When immunotoxin is administrated together with yeast mannan, which enhances the level of active immunotoxin in circulation by inhibition of liver uptake, the anti-cancer efficacy of immunotoxin in vivo is drastically improved.


Asunto(s)
Anticuerpos Monoclonales/metabolismo , Ricina/sangre , Animales , Disulfuros/metabolismo , Inmunoglobulina G/metabolismo , Técnicas In Vitro , Inyecciones Intravenosas , Pulmón/metabolismo , Macaca mulatta , Macrófagos/metabolismo , Mananos , Tasa de Depuración Metabólica , Ratones , Ratones Endogámicos BALB C , Unión Proteica , Conejos , Ratas , Especificidad de la Especie , Distribución Tisular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA