1.
Microcirculation ; 31(1): e12835, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37947797

RESUMEN

OBJECTIVE: The success of engineered tissues continues to be limited by time to vascularization and perfusion. Recently, we described a simple microsurgical approach, termed micropuncture (MP), which could be used to rapidly vascularize an adjacently placed scaffold from the recipient macrovasculature. Here we studied the long-term persistence of the MP-induced microvasculature. METHODS: Segmental 60 µm diameter MPs were created in the recipient rat femoral artery and vein followed by coverage with a simple Type 1 collagen scaffold. The recipient vasculature and scaffold were then wrapped en bloc with a silicone sheet to isolate intrinsic vascularization. Scaffolds were harvested at 28 days post-implantation for detailed analysis, including using a novel artificial intelligence (AI) approach. RESULTS: MP scaffolds demonstrated a sustained increase of vascular density compared to internal non-MP control scaffolds (p < 0.05) secondary to increases in both vessel diameters (p < 0.05) and branch counts (p < 0.05). MP scaffolds also demonstrated statistically significant increases in red blood cell (RBC) perfused lumens. CONCLUSIONS: This study further highlights that the intrinsic MP-induced vasculature continues to persist long-term. Its combination of rapid and stable angiogenesis represents a novel surgical platform for engineered scaffold and graft perfusion.


Asunto(s)
Inteligencia Artificial , Andamios del Tejido , Animales , Ratas , Punciones , Siliconas , Ingeniería de Tejidos , Angiogénesis
2.
Biomacromolecules ; 25(7): 4510-4522, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38877976

RESUMEN

Stimuli-responsive adhesives with on-demand adhesion capabilities are highly advantageous for facilitating wound healing. However, the triggering conditions of stimuli-responsive adhesives are cumbersome, even though some of them are detrimental to the adhesive and adjacent natural tissues. Herein, a novel stimuli-responsive adhesive called shear-stiffening adhesive (SSA) has been created by constructing a poly(diborosiloxane)-based silicone network for the first time, and SSA exhibits a rate-responsive adhesion behavior. Furthermore, we introduced bactericidal factors (PVP-I) into SSA and applied it as a wound dressing to promote the healing of infected wounds. Impressively, the wound dressing not only has excellent biocompatibility and long-term antibacterial properties but also performs well in accelerating wound healing. Therefore, this study provides a new strategy for the synthesis of intelligent adhesives with force rate response, which simplifies the triggering conditions by the force rate. Thus, SSA has great potential to be applied in wound management as an intelligent bioadhesive with on-demand adhesion performance.


Asunto(s)
Vendajes , Siliconas , Cicatrización de Heridas , Cicatrización de Heridas/efectos de los fármacos , Animales , Siliconas/química , Adhesivos/química , Adhesivos/farmacología , Antibacterianos/farmacología , Antibacterianos/química , Ratones , Adhesivos Tisulares/química , Adhesivos Tisulares/farmacología , Humanos , Staphylococcus aureus/efectos de los fármacos
3.
J Surg Oncol ; 129(2): 208-218, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37792635

RESUMEN

BACKGROUND AND OBJECTIVES: Neoadjuvant chemotherapy (NCH) has demonstrated efficacy in downsizing tumors and facilitating less extensive surgery. However, immediate breast reconstruction (IBR) after NCH has raised concerns regarding higher complication rates. This study evaluates the impact of NCH on outcomes following IBR with a latissimus dorsi flap and implant (LDI) after mastectomy. METHODS: Cases from a prospective maintained database were reviewed, and patients classified according to whether or not they received NCH. Risk factors and major and minor complications in both groups were then analyzed. RESULTS: Among the 196 patients who underwent 198 IBR procedures, 38.4% received NCH and 66.1% did not. The overall complication rate was 46.7% in the non-NCH group and 53.3% in the NCH group (p = 0.650). The presence of comorbidities increased the likelihood of any complication (odds ratio [OR]: 3.46; 95% confidence interval [CI]: 1.38-8.66; p = 0.008) as well as major complications (OR: 3.35; 95% CI: 1.03-10.95; p = 0.045). Although patients in the NCH group experienced more major complications (10.5% vs. 4.9%; p = 0.134) and early loss of breast reconstruction (3.9% vs. 0.8%; p = 0.128), these findings were not statistically significant. CONCLUSION: This study found no statistically significant association between NCH and higher risk of complications or loss of IBR with LDI after mastectomy.


Asunto(s)
Neoplasias de la Mama , Mamoplastia , Músculos Superficiales de la Espalda , Humanos , Femenino , Mastectomía/efectos adversos , Mastectomía/métodos , Terapia Neoadyuvante/métodos , Resultado del Tratamiento , Estudios Prospectivos , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/cirugía , Neoplasias de la Mama/etiología , Mamoplastia/efectos adversos , Mamoplastia/métodos , Siliconas , Estudios Retrospectivos
4.
Int J Legal Med ; 138(4): 1357-1368, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38570340

RESUMEN

Gunshot wound analysis is an important part of medicolegal practice, in both autopsies and examinations of living persons. Well-established and studied simulants exist that exhibit both physical and biomechanical properties of soft-tissues and bones. Current research literature on ballistic wounds focuses on the biomechanical properties of skin simulants. In our extensive experimental study, we tested numerous synthetic and natural materials, regarding their macromorphological bullet impact characteristics, and compared these data with those from real bullet injuries gathered from medicolegal practice. Over thirty varieties of potential skin simulants were shot perpendicularly, and at 45°, at a distance of 10 m and 0.3 m, using full metal jacket (FMJ) projectiles (9 × 19 mm Luger). Simulants included ballistic gelatine at various concentrations, dental silicones with several degrees of hardness, alginates, latex, chamois leather, suture trainers for medical training purposes and various material compound models. In addition to complying to the general requirements for a synthetic simulant, results obtained from dental silicones shore hardness 70 (backed with 20 % by mass gelatine), were especially highly comparable to gunshot entry wounds in skin from real cases. Based on these results, particularly focusing on the macroscopically detectable criteria, we can strongly recommend dental silicone shore hardness 70 as a skin simulant for wound ballistics examinations.


Asunto(s)
Balística Forense , Gelatina , Piel , Heridas por Arma de Fuego , Heridas por Arma de Fuego/patología , Balística Forense/métodos , Humanos , Piel/lesiones , Piel/patología , Látex , Siliconas , Modelos Biológicos , Dureza
5.
J Toxicol Environ Health B Crit Rev ; 27(3): 106-129, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38375664

RESUMEN

Cyclic and linear siloxanes are compounds synthesized from silicon consisting of alternating atoms of silicone and oxygen [Si-O] units with organic side chains. The most common cyclic siloxanes are octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5), and dodecamethylcyclohexasiloxane (D6), while the most common linear siloxanes are high molecular weight polydimethylsiloxanes (PDMS) and low molecular weight volatile linear siloxanes known as hexamethyldisiloxane (L2), octamethyltrisiloxane (L3), decamethyltetrasiloxane (L4), dodecamethylpentasiloxane (L5). These compounds (1) exhibit low dermal toxicity, (2) are generally inert and non-reactive, and (3) are compatible with a wide range of chemicals offering beneficial chemical properties which include the following: wash-off or transfer resistance from the skin, sun protection factor (SPF) enhancement, emolliency in cleaning products). Because of these properties, these compounds are incorporated into multiple consumer products for use on the skin, such as cosmetics and health-care products, with over 300,000 tons annually sold into the personal care and consumer products sector. Because of their widespread use in consumer products and potential for human dermal exposure, a comprehensive understanding of the dermal absorption and overall fate of siloxanes following dermal exposure is important. This review summarizes available data associated with the dermal absorption/penetration as well as fate of the most commonly used siloxane substances.


Asunto(s)
Cosméticos , Siloxanos , Humanos , Siloxanos/toxicidad , Siloxanos/química , Piel , Siliconas , Dimetilpolisiloxanos
6.
Environ Sci Technol ; 58(15): 6499-6508, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38572580

RESUMEN

A social housing estate in Denmark was designated for demolition due to exceedance of guidance values for polychlorinated biphenyls (PCBs) in indoor air. Here, we deployed precleaned silicone wristbands (n = 46) among demolition workers of these contaminated buildings during single workdays while conducting various work tasks. We established a method to analyze all 209 PCBs in wristbands to identify prominent congeners of exposure and evaluate differences between tasks. Wristbands were extracted using microwave-assisted extraction and then concentrated for gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. Twenty-nine chromatographic peaks representing 37 congeners were detected in every wristband, and tetra-CBs were the dominant homologue group. PCB-66, -44, and -70 were the most abundant congeners measured in worker wristbands, none of which are included within the typical seven indicator or WHO 12 PCBs. Workers who cut PCB-containing sealants had wristbands with the highest PCB concentrations (geometric mean ∑209PCBs = 1963 ng/g wristband), which were followed by those handling concrete elements on the building roof. Additionally, wristbands captured a broader range of PCBs than has been previously measured in air and serum samples. Taken together, our results highlight the importance of total congener analysis in assessing current PCB exposure in demolition work and the utility of wristbands for assessing these exposures.


Asunto(s)
Bifenilos Policlorados , Humanos , Bifenilos Policlorados/análisis , Monitoreo del Ambiente , Espectrometría de Masas en Tándem , Siliconas
7.
Environ Sci Technol ; 58(12): 5229-5243, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38466915

RESUMEN

Silicone-based passive samplers, commonly paired with gas chromatography-mass spectrometry (GC-MS) analysis, are increasingly utilized for personal exposure assessments. However, its compatibility with the biotic exposome remains underexplored. In this study, we introduce the wearable silicone-based AirPie passive sampler, coupled with nontargeted liquid chromatography with high-resolution tandem mass spectrometry (LC-HRMS/MS), GC-HRMS, and metagenomic shotgun sequencing methods, offering a comprehensive view of personalized airborne biotic and abiotic exposomes. We applied the AirPie samplers to 19 participants in a unique deep underwater confined environment, annotating 4,390 chemical and 2,955 microbial exposures, integrated with corresponding transcriptomic data. We observed significant shifts in environmental exposure and gene expression upon entering this unique environment. We noted increased exposure to pollutants, such as benzenoids, polycyclic aromatic hydrocarbons (PAHs), opportunistic pathogens, and associated antibiotic-resistance genes (ARGs). Transcriptomic analyses revealed the activation of neurodegenerative disease-related pathways, mostly related to chemical exposure, and the repression of immune-related pathways, linked to both biological and chemical exposures. In summary, we provided a comprehensive, longitudinal exposome map of the unique environment and underscored the intricate linkages between external exposures and human health. We believe that the AirPie sampler and associated analytical methods will have broad applications in exposome and precision medicine.


Asunto(s)
Exposoma , Enfermedades Neurodegenerativas , Hidrocarburos Policíclicos Aromáticos , Dispositivos Electrónicos Vestibles , Humanos , Espacios Confinados , Transcriptoma , Monitoreo del Ambiente/métodos , Siliconas
8.
Environ Sci Technol ; 58(15): 6772-6780, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38577774

RESUMEN

The quality of chemical analysis is an important aspect of passive sampling-based environmental assessments. The present study reports on a proficiency testing program for the chemical analysis of hydrophobic organic compounds in silicone and low-density polyethylene (LDPE) passive samplers and hydrophilic compounds in polar organic chemical integrative samplers. The median between-laboratory coefficients of variation (CVs) of hydrophobic compound concentrations in the polymer phase were 33% (silicone) and 38% (LDPE), similar to the CVs obtained in four earlier rounds of this program. The median CV over all rounds was 32%. Much higher variabilities were observed for hydrophilic compound concentrations in the sorbent: 50% for the untransformed data and a factor of 1.6 after log transformation. Limiting the data to the best performing laboratories did not result in less variability. Data quality for hydrophilic compounds was only weakly related to the use of structurally identical internal standards and was unrelated to the choice of extraction solvent and extraction time. Standard deviations of the aqueous concentration estimates for hydrophobic compound sampling by the best performing laboratories were 0.21 log units for silicone and 0.27 log units for LDPE (factors of 1.6 to 1.9). The implications are that proficiency testing programs may give more realistic estimates of uncertainties in chemical analysis than within-laboratory quality control programs and that these high uncertainties should be taken into account in environmental assessments.


Asunto(s)
Polietileno , Contaminantes Químicos del Agua , Polietileno/análisis , Contaminantes Químicos del Agua/análisis , Monitoreo del Ambiente/métodos , Compuestos Orgánicos , Siliconas
9.
Environ Res ; 258: 119465, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38908658

RESUMEN

In the United States and abroad, ortho-phthalates and non-ortho-phthalate plasticizers continue to be used within a diverse array of consumer products. Prior California-specific biomonitoring programs for ortho-phthalates have focused on rural, agricultural communities and, to our knowledge, these programs have not measured the potential for exposure to non-ortho-phthalate plasticizers. Therefore, the potential for human exposure to ortho-phthalates and non-ortho-phthalate plasticizers have not been adequately addressed in regions of California that have higher population density. Since there are numerous sources of ortho-phthalates and non-ortho-phthalate plasticizers in population-dense, urban regions, the objective of this study was to leverage silicone wristbands to quantify aggregate ortho-phthalate and non-ortho-phthalate plasticizer exposure over a 5-day period across two different cohorts (2019 and 2020) of undergraduate students at the University of California, Riverside (UCR) that commute from all over Southern California. Based on 5 d of aggregate exposure across two different cohorts, total ortho-phthalate plus non-ortho-phthalate plasticizer concentrations ranged, on average, from ∼100,000-1,000,000 ng/g. Based on the distribution of individual ortho-phthalate and non-ortho-phthalate plasticizer concentrations, the concentrations of di-isononyl phthalate (DiNP, a high molecular weight ortho-phthalate), di (2-ethylhexyl) phthalate (DEHP, a high molecular weight ortho-phthalate), and di-2-ethylhexyl terephthalate (DEHT, a non-ortho-phthalate plasticizer) detected within wristbands were higher than the remaining seven ortho-phthalates and non-ortho-phthalate plasticizers measured, accounting for approximately 94-97% of the total mass depending on the cohort. Overall, our findings raise concerns about chronic DiNP, DEHP, and DEHT exposure in urban, population-dense regions throughout California.


Asunto(s)
Exposición a Riesgos Ambientales , Ácidos Ftálicos , Plastificantes , Humanos , Plastificantes/análisis , California , Ácidos Ftálicos/análisis , Exposición a Riesgos Ambientales/análisis , Siliconas/química , Contaminantes Ambientales/análisis , Femenino , Masculino , Adulto Joven , Monitoreo del Ambiente/métodos , Muñeca , Adulto
10.
Environ Res ; 250: 118537, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38408627

RESUMEN

E-waste recycling is an increasingly important activity that contributes to reducing the burden of end-of-life electronic and electrical apparatus and allows for the EU's transition to a circular economy. This study investigated the exposure levels of selected persistent organic pollutants (POPs) in workers from e-waste recycling facilities across Europe. The concentrations of seven polychlorinated biphenyls (PCBs) and eight polybrominated diphenyl ethers (PBDEs) congeners were measured by GC-MS. Workers were categorized into five groups based on the type of e-waste handled and two control groups. Generalized linear models were used to assess the determinants of exposure levels among workers. POPs levels were also assessed in dust and silicone wristbands (SWB) and compared with serum. Four PCB congeners (CB 118, 138, 153, and 180) were frequently detected in serum regardless of worker's category. With the exception of CB 118, all tested PCBs were significantly higher in workers compared to the control group. Controls working in the same company as occupationally exposed (Within control group), also displayed higher levels of serum CB 180 than non-industrial controls with no known exposures to these chemicals (Outwith controls) (p < 0.05). BDE 209 was the most prevalent POP in settled dust (16 µg/g) and SWB (220 ng/WB). Spearman correlation revealed moderate to strong positive correlations between SWB and dust. Increased age and the number of years smoked cigarettes were key determinants for workers exposure. Estimated daily intake through dust ingestion revealed that ΣPCB was higher for both the 50th (0.03 ng/kg bw/day) and 95th (0.09 ng/kg bw/day) percentile exposure scenarios compared to values reported for the general population. This study is one of the first to address the occupational exposure to PCBs and PBDEs in Europe among e-waste workers through biomonitoring combined with analysis of settled dust and SWB. Our findings suggest that e-waste workers may face elevated PCB exposure and that appropriate exposure assessments are needed to establish effective mitigation strategies.


Asunto(s)
Polvo , Residuos Electrónicos , Éteres Difenilos Halogenados , Exposición Profesional , Bifenilos Policlorados , Reciclaje , Humanos , Polvo/análisis , Exposición Profesional/análisis , Europa (Continente) , Residuos Electrónicos/análisis , Éteres Difenilos Halogenados/sangre , Éteres Difenilos Halogenados/análisis , Adulto , Masculino , Persona de Mediana Edad , Bifenilos Policlorados/sangre , Bifenilos Policlorados/análisis , Femenino , Contaminantes Orgánicos Persistentes/sangre , Siliconas , Monitoreo del Ambiente/métodos
11.
J Nanobiotechnology ; 22(1): 467, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39103899

RESUMEN

BACKGROUND: The elastomechanical properties of nanocarriers have recently been discussed as important for the efficient delivery of various therapeutics. Some data indicate that optimal nanocarriers' elasticity can modulate in vivo nanocarrier stability, interaction with phagocytes, and uptake by target cells. Here, we presented a study to extensively analyze the in vivo behavior of LIP-SS liposomes that were modified by forming the silicone network within the lipid bilayers to improve their elastomechanical properties. We verified liposome pharmacokinetic profiles and biodistribution, including retention in tumors on a mouse model of breast cancer, while biocompatibility was analyzed on healthy mice. RESULTS: We showed that fluorescently labeled LIP-SS and control LIP-CAT liposomes had similar pharmacokinetic profiles, biodistribution, and retention in tumors, indicating that modified elasticity did not improve nanocarrier in vivo performance. Interestingly, biocompatibility studies revealed no changes in blood morphology, liver, spleen, and kidney function but indicated prolonged activation of immune response manifesting in increased concentration of proinflammatory cytokines in sera of animals exposed to all tested liposomes. CONCLUSION: Incorporating the silicone layer into the liposome structure did not change nanocarriers' characteristics in vivo. Further modification of the LIP-SS surface, including decoration with hydrophilic stealth polymers, should be performed to improve their pharmacokinetics and retention in tumors significantly. Activation of the immune response by LIP-SS and LIP-CAT, resulting in elevated inflammatory cytokine production, requires detailed studies to elucidate its mechanism.


Asunto(s)
Elasticidad , Liposomas , Siliconas , Liposomas/química , Animales , Ratones , Femenino , Siliconas/química , Distribución Tisular , Ratones Endogámicos BALB C , Línea Celular Tumoral , Neoplasias de la Mama/tratamiento farmacológico , Membrana Dobles de Lípidos/química , Portadores de Fármacos/química
12.
Biofouling ; 40(2): 177-192, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38465991

RESUMEN

Silicone materials are widely used in fouling release coatings, but developing eco-friendly protection via biosourced coatings, such as polyhydroxyalcanoates (PHA) presents a major challenge. Anti-bioadhesion properties of medium chain length PHA and short chain length PHA films are studied and compared with a reference Polydimethylsiloxane coating. The results highlight the best capability of the soft and low-roughness PHA-mcl films to resist bacteria or diatoms adsorption as compared to neat PDMS and PHBHV coatings. These parameters are insufficient to explain all the results and other properties related to PHA crystallinity are discussed. Moreover, the addition of a low amount of PEG copolymers within the coatings, to create amphiphilic coatings, boosts their anti-adhesive properties. This work reveals the importance of the physical or chemical ambiguity of surfaces in their anti-adhesive effectiveness and highlights the potential of PHA-mcl film to resist the primary adhesion of microorganisms.


Asunto(s)
Diatomeas , Polihidroxialcanoatos , Biopelículas , Siliconas/química , Adsorción
13.
Biofouling ; 40(2): 209-222, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38500010

RESUMEN

This study explores the potential of geranium essential oil as a natural solution for combating marine biofouling, addressing the environmental concerns associated with commercial antifouling coatings. Compounds with bactericidal activities were identified by 13Carbon nuclear magnetic resonance (13C NMR). Thermogravimetric analysis (TGA) revealed minimal impact on film thermal stability, maintaining suitability for antifouling applications. The addition of essential oil induced changes in the morphology of the film and Fourier transform infrared spectroscopy (FTIR) analysis indicated that oil remained within the film. Optical microscopy showed an increase in coating porosity after immersion in a marine environment. A total of 18 bacterial colonies were isolated, with Psychrobacter adeliensis and Shewanella algidipiscicola being the predominant biofilm-forming species. The geranium essential oil-based coating demonstrated the ability to reduce the formation of Psychrobacter adeliensis biofilms and effectively inhibit macrofouling adhesion for a duration of 11 months.


Asunto(s)
Incrustaciones Biológicas , Geranium , Aceites Volátiles , Psychrobacter , Biopelículas , Incrustaciones Biológicas/prevención & control , Aceites Volátiles/farmacología , Aceites de Silicona/farmacología , Siliconas
14.
BMC Med Imaging ; 24(1): 53, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38429683

RESUMEN

BACKGROUND: The diameter of the ostial and proximal left main coronary artery can be greater than 5.0 mm. However, the diameters of the mostly available coronary drug-eluting stents (DESs) are ≤ 4.0 mm. Whether high-pressure dilatation can increase the diameter of stents from 4.0 to 5.0 mm and whether post-dilatation leads to longitudinal stent deformation (LSD) of 4.0-mm-diameter stents have rarely been studied. Therefore, this study aims to evaluate LSD and stent malapposition of six types of commercially available 4.0-mm-diameter stents in China in a 5.0-mm-diameter artificial blood vessel model by optical coherence tomography (OCT) in vitro. METHODS: The left main coronary artery was simulated by a truncated cone-shaped silicone tube. The internal diameters were 4.0 mm at one end of the silicone tube and 5.0 mm at the other end. Six different types of coronary stents widely used in China were selected for this study. Each stent was respectively implanted into the simulated blood vessel and dilated to a diameter of 4.2 mm according to the stent-balloon pressure compliance table. The stents were subjected to post-dilatation with a 5.0 × 15-mm noncompliant balloon. The LSD ratio of the longitudinal axis of each stent and stent malapposition were measured through OCT, and any fractures of the stents were determined. RESULTS: None of the six types of stents fractured following post-dilatation. The longitudinal axes of the BuMA and Excrossal stents were slightly shortened, while the other stents were elongated after high-pressure post-dilatation. All stents expanded to a diameter of 5.0 mm without incomplete stent apposition, except for the Nano Plus stent, which remained malapposed after high-pressure post-dilatation. CONCLUSION: All 4.0-mm-diameter stents can be expanded to a diameter of 5.0 mm by noncompliant balloon post-dilatation without stent strut fracture. Most stents were found to be well apposed after high-pressure post-dilatation. However, LSD was observed after post-balloon dilatation. Stent malapposition might be positively correlated with the percentage change in stent length.


Asunto(s)
Stents , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Dilatación , Stents/efectos adversos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Siliconas
15.
Intern Med J ; 54(2): 204-213, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38140778

RESUMEN

The first dedicated tracheobronchial silicone stent was designed by the French pulmonologist Jean-Paul Dumon. The most common indications for stenting are to minimise extrinsic airway compression from mass effect, maintain airway patency due to intrinsic obstruction or treat significant nonmalignant airway narrowing or fistulae. Silicone stents require rigid bronchoscopy for insertion; however, they are more readily repositioned and removed compared with metallic stents. Metallic stents demonstrate luminal narrowing when loads are applied to their ends, therefore stents should either be reinforced at the ends or exceed the area of stenosis by a minimum of 5 mm. Nitinol, a nickel-titanium metal alloy, is currently the preferred material used for airway stents. Airway stenting provides effective palliation for patients with severe symptomatic obstruction. Drug-eluting and three-dimensional printing of airway stents present promising solutions to the challenges of the physical and anatomical constraints of the tracheobronchial tree. Biodegradable stents could also be a solution for the treatment of nonmalignant airway obstruction.


Asunto(s)
Obstrucción de las Vías Aéreas , Broncoscopía , Níquel , Titanio , Humanos , Broncoscopía/métodos , Obstrucción de las Vías Aéreas/cirugía , Siliconas , Metales , Stents , Resultado del Tratamiento
16.
BMC Ophthalmol ; 24(1): 112, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38454351

RESUMEN

INTRODUCTION: Severe congenital ptosis poses a complex challenge for oculoplastic surgeons, requiring meticulous surgical intervention to restore eyelid function and improve aesthetic outcomes mainly by using frontalis sling approach. A crucial issue in frontalis sling surgeries is the sustainability of effect. PURPOSE: This retrospective study reports the outcomes of two surgical techniques for treating severe congenital ptosis in the paediatric age group: Silicon rods ptosis sling and a novel technique involving the use of Silicon rods with green braided polyester (Ethibond) sutures to secure the rods in place "sling for the sling". METHODS: The medical records of children who underwent frontalis suspension were reviewed in a retrospective fashion. We identified two groups; the first group (20 patients: 35 eyelids) had the traditional frontalis suspension surgery using silicone suspension set, the second group (14 patients: 25 eyelids) was operated using the new "sling for sling" technique. We used the postoperative marginal reflex distance-1 (MRD-1) as the primary outcome measure while the frequency of both wound related complications and recurrence were considered as secondary outcome measures. Post operative data were collected and compared after 1 month, 6 months, 12 months, and 18 months. RESULTS: Preliminary results indicate promising outcomes for both techniques, with significant improvement in eyelid elevation observed in both groups. However, the novel technique using Silicon rods with Ethibond sutures demonstrated enhanced sustainability, leading to a more durable outcome with significantly less recurrence. CONCLUSION: This study highlights the potential benefits of the novel technique in treating severe congenital ptosis and introduces an innovative approach to Silicone rods fixation to achieve a long-term corrective effect.


Asunto(s)
Blefaroplastia , Blefaroptosis , Niño , Humanos , Blefaroplastia/métodos , Estudios Retrospectivos , Silicio , Técnicas de Sutura , Blefaroptosis/cirugía , Blefaroptosis/congénito , Siliconas , Músculos Oculomotores/cirugía , Resultado del Tratamiento
17.
Skin Res Technol ; 30(8): e13888, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39099447

RESUMEN

BACKGROUND: Incontinence-associated dermatitis (IAD) is a tough problem in clinical settings, not only increasing the risk of complications like catheter-related urinary tract infections and pressure ulcers in elderly and critically ill patients, but also prolonging hospital stays, raising hospital costs, and possibly leading to medical disputes. This study is aimed to evaluate the therapeutic effect of silicone dressing combined with topical oxygen therapy on IAD in a rat model. METHODS: An IAD rat model induced by synthetic urine with trypsin was established. Hematoxylin & eosin staining was carried out to examine skin histology. Using immunofluorescence, the microvessel density in the affected skin tissues was determined. ELISA was performed to measure the concentrations of inflammatory cytokines and angiogenic factors in serum. The mRNA expression of EGF, PDGF, and VEGF was detected via qRT-PCR. Western blotting was employed to determine NF-κB p65/STAT1 pathway-related protein levels. RESULTS: Compared to single therapy, silicone dressing combined with topical oxygen therapy could significantly reduce the severity of IAD, improve skin histology, inhibit inflammation, and promote angiogenesis in IAD rat models. Additionally, the results showed that relatively speaking, the combined therapy suppressed the NF-κB p65/STAT1 signaling pathway more effectively. CONCLUSION: These findings indicated that silicone dressing combined with topical oxygen therapy can alleviate IAD through promoting wound healing and inhibiting inflammation via NF-κB p65/STAT1 signaling pathway in a rat model, which provided a theoretical basis for the prevention and treatment of IAD in clinic.


Asunto(s)
Vendajes , Dermatitis , Modelos Animales de Enfermedad , Oxígeno , Ratas Sprague-Dawley , Factor de Transcripción STAT1 , Transducción de Señal , Siliconas , Factor de Transcripción ReIA , Incontinencia Urinaria , Animales , Ratas , Transducción de Señal/efectos de los fármacos , Oxígeno/administración & dosificación , Factor de Transcripción STAT1/metabolismo , Dermatitis/terapia , Dermatitis/etiología , Factor de Transcripción ReIA/metabolismo , Incontinencia Urinaria/terapia , Incontinencia Urinaria/etiología , Masculino
18.
BMC Pulm Med ; 24(1): 383, 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39123192

RESUMEN

BACKGROUND: A straight silicone stent can be used to treat proximal benign tracheal stenosis in non-surgical candidates. However, stent migration is a common complication when placed at a particular location and can lead to major complications. This case series of laryngotracheal stenosis reports a fixation method for straight silicone stents in the subglottic trachea (Stage 3 of the McCaffrey classification). METHODS: The medical charts of these patients scheduled for straight silicone stent placement with suture fixation between 2014 and 2020 at the CHU UCL Namur Hospital (Belgium) were retrospectively reviewed. The procedure was performed using a rigid bronchoscope. Details of the procedure were obtained from medical records. RESULTS: This case series included six patients (males: 4, females: 2). The median patient age was 59 years. Two suture fixations were placed following previous silicone stent migration episodes, whereas the others were placed proactively to avoid this risk. All fixations were performed by the device Freka® Pexact II ENFIt®, originally developed for gastropexy in endoscopic gastrostomy. The sutures were subcutaneously buried. CONCLUSIONS: During the 6-month follow-up period, complications such as fixation issues and stent migration were reported despite the off-label use of the treatment. The straight silicone stent fixation technique used in this case series was simple and effective for securing the stent in upper benign tracheal stenosis.


Asunto(s)
Laringoestenosis , Stents , Estenosis Traqueal , Humanos , Femenino , Persona de Mediana Edad , Masculino , Estenosis Traqueal/cirugía , Laringoestenosis/cirugía , Estudios Retrospectivos , Anciano , Adulto , Técnicas de Sutura , Recurrencia , Siliconas , Broncoscopía
19.
Ophthalmic Physiol Opt ; 44(5): 876-883, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38712751

RESUMEN

OBJECTIVE: This randomised clinical trial assessed the impact on symptoms, tear film dynamics and ocular surface integrity of daily disposable silicone-hydrogel contact lenses (CLs) over a month, paying special attention to lid wiper epitheliopathy (LWE) and its implications for CL discomfort. METHODS: Neophyte CL wearers (n = 44, 21.09 ± 5.00 years old) were randomly assigned to either the experimental (n = 24) or control group (n = 20). Participants assigned to the experimental group were required to wear daily disposable CLs for 1 month for at least 8 h/day and 6 days/week. All participants were healthy subjects (no history of ocular surgery or active ocular disease) with spherical refractive errors between -8.00 and +5.00 D and cylindrical power <0.75 D. At the baseline and 1-month sessions, the Dry Eye Questionnaire 5 (DEQ-5) was completed, together with the measurement of tear film osmolarity with the TearLab osmometer, tear meniscus height (TMH) and lipid layer pattern (LLP) using a slit-lamp with Tearscope Plus attached, fluorescein break-up time (FBUT), maximum blink interval (MBI), corneal staining with fluorescein under cobalt blue light and LWE with lissamine green under slit lamp and halogen white light. RESULTS: At the baseline session, LWE showed a negative correlation with DEQ-5 (r = -0.37, p = 0.02). Significant differences in FBUT and LWE (p = 0.04) and a positive correlation between LWE and DEQ-5 (r = 0.49, p = 0.007) were observed at 1 month. Intrasession analysis at 1 month showed significant differences between the experimental and control groups in DEQ-5, FBUT and LWE (all p ≤ 0.02). Intersession analysis in the experimental group showed variations in DEQ-5, FBUT and LWE (all p ≤ 0.02) but no significant variation in the control group (all p ≥ 0.11). CONCLUSION: The presence of LWE was significantly correlated with higher symptom values in the DEQ-5. Also, participants in the experimental group presented higher values of LWE after 1 month of CL wear, in comparison with the control group.


Asunto(s)
Lentes de Contacto Hidrofílicos , Equipos Desechables , Síndromes de Ojo Seco , Lágrimas , Humanos , Masculino , Femenino , Lágrimas/fisiología , Lágrimas/metabolismo , Adulto Joven , Síndromes de Ojo Seco/fisiopatología , Síndromes de Ojo Seco/diagnóstico , Adulto , Errores de Refracción/terapia , Errores de Refracción/fisiopatología , Siliconas , Adolescente , Encuestas y Cuestionarios , Enfermedades de los Párpados/fisiopatología , Enfermedades de los Párpados/terapia , Concentración Osmolar
20.
Acta Radiol ; 65(7): 716-723, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38872362

RESUMEN

BACKGROUND: With rising breast augmentations worldwide, there is an increasing clinical need for an early and accurate detection of implant complications. PURPOSE: To compare the quality of chemical shift encoding-based (CSE) water-fat-silicone separation compared to double inversion recovery (DIR) silicone-only imaging in breast magnetic resonance imaging (MRI). MATERIAL AND METHODS: This retrospective, single-center study included women with silicone implants subjected to 3-T MRI between January 2021 and March 2022. MRI included (i) two-dimensional silicone-only T2-weighted turbo spin echo DIR acquisition and (ii) three-dimensional CSE imaging based on multi-echo gradient-echo sequence enabling water-, fat-, and silicone-image separation. Images were evaluated and compared by three independent radiologists using a clinically established rating including differentiability of the silicone implant, visibility and contouring of the adjacent fibrous capsule, and accuracy of intralesional folds in a ranking of 1-5. The apparent contrast-to-noise (aCNR) was calculated. RESULTS: In 71 women, the average quality of water-fat-silicone images from CSE imaging was assessed as "good" (assessment 4 ± 0.9). In 68 (96%) patients, CSE imaging achieved a concise delineation of the silicone implant and precise visualization of the fibrous capsule that was not distinguishable in DIR imaging. Implant ruptures were more easily detected in CSE imaging. The aCNR was higher in CSE compared to DIR imaging (18.43 ± 9.8 vs. 14.73 ± 2.5; P = 0.002). CONCLUSION: Intrinsically co-registered water-fat-silicone-separated CSE-based images enable a reliable assessment of silicone implants. The simultaneously improved differentiability of the implant and fibrous capsule may provide clinicians with a valuable tool for an accurate evaluation of implant integrity and early detection of potential complications.


Asunto(s)
Implantes de Mama , Imagen por Resonancia Magnética , Siliconas , Humanos , Femenino , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Adulto , Persona de Mediana Edad , Mama/diagnóstico por imagen , Agua , Tejido Adiposo/diagnóstico por imagen , Geles de Silicona , Anciano
SELECCIÓN DE REFERENCIAS