1.
Histochem Cell Biol ; 161(5): 367-379, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38347221

RESUMEN

Valvular heart disease leads to ventricular pressure and/or volume overload. Pressure overload leads to fibrosis, which might regress with its resolution, but the limits and details of this reverse remodeling are not known. To gain more insight into the extent and nature of cardiac fibrosis in valve disease, we analyzed needle biopsies taken from the interventricular septum of patients undergoing surgery for valve replacement focusing on the expression and distribution of major extracellular matrix protein involved in this process. Proteomic analysis performed using mass spectrometry revealed an excellent correlation between the expression of collagen type I and III, but there was little correlation with the immunohistochemical staining performed on sister sections, which included antibodies against collagen I, III, fibronectin, sarcomeric actin, and histochemistry for wheat germ agglutinin. Surprisingly, the immunofluorescence intensity did not correlate significantly with the gold standard for fibrosis quantification, which was performed using Picrosirius Red (PSR) staining, unless multiplexed on the same tissue section. There was also little correlation between the immunohistochemical markers and pressure gradient severity. It appears that at least in humans, the immunohistochemical pattern of fibrosis is not clearly correlated with standard Picrosirius Red staining on sister sections or quantitative proteomic data, possibly due to tissue heterogeneity at microscale, comorbidities, or other patient-specific factors. For precise correlation of different types of staining, multiplexing on the same section is the best approach.


Asunto(s)
Estenosis de la Válvula Aórtica , Proteínas de la Matriz Extracelular , Fibrosis , Humanos , Estenosis de la Válvula Aórtica/metabolismo , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/cirugía , Fibrosis/metabolismo , Fibrosis/patología , Proteínas de la Matriz Extracelular/metabolismo , Proteínas de la Matriz Extracelular/análisis , Insuficiencia de la Válvula Aórtica/metabolismo , Insuficiencia de la Válvula Aórtica/patología , Insuficiencia de la Válvula Aórtica/cirugía , Masculino , Tabique Interventricular/patología , Tabique Interventricular/metabolismo , Femenino , Anciano , Persona de Mediana Edad
2.
J Cardiovasc Electrophysiol ; 35(4): 802-810, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38409896

RESUMEN

INTRODUCTION: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions. METHODS: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34). RESULTS: The paced QRS duration (QRS-d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS-d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS-d and the lead depth. CONCLUSION: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.


Asunto(s)
Estimulación Cardíaca Artificial , Tabique Interventricular , Humanos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Catéteres , Electrocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Tabique Interventricular/diagnóstico por imagen
3.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38691562

RESUMEN

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Tabique Interventricular , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Tabique Interventricular/diagnóstico por imagen , Anciano de 80 o más Años , Factores de Riesgo , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/diagnóstico por imagen , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Conducción Cardíaco/diagnóstico por imagen , Resultado del Tratamiento , Valor Predictivo de las Pruebas , Medición de Riesgo , Índice de Severidad de la Enfermedad , Estudios Retrospectivos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Tomografía Computarizada Multidetector , Tomografía Computarizada por Rayos X , Potenciales de Acción
4.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38703372

RESUMEN

AIMS: To characterize the diagnosis, frequency, and procedural implications of septal venous channel perforation during left bundle branch area pacing (LBBAP). METHODS AND RESULTS: All consecutive patients undergoing LBBAP over an 8-month period were prospectively studied. During lead placement, obligatory septal contrast injection was performed twice, at initiation (implant entry zone) and at completion (fixation zone). An intuitive fluoroscopic schema using orthogonal views (left anterior oblique/right anterior oblique) and familiar landmarks is described. Using this, we resolved zonal distribution (I-VI) of lead position on the ventricular septum and its angulation (post-fixation angle θ). Subjects with and without septal venous channel perforation were compared. Sixty-one patients {male 57.3%, median age [interquartile range (IQR)] 69.5 [62.5-74.5] years} were enrolled. Septal venous channel perforation was observed in eight (13.1%) patients [male 28.5%, median age (IQR) 64 (50-75) years]. They had higher frequency of (i) right-sided implant (25% vs. 1.9%, P = 0.04), (ii) fixation in zone III at the mid-superior septum (75% vs. 28.3%, P = 0.04), (iii) steeper angle of fixation-median θ (IQR) [19 (10-30)° vs. 5 (4-19)°, P = 0.01], and (iv) longer median penetrated-lead length (IQR) [13 (10-14.8) vs. 10 (8.5-12.5) mm, P = 0.03]. Coronary sinus drainage of contrast was noted in five (62.5%) patients. Abnormal impedance drops during implantation (12.5% vs. 5.7%, P = NS) were not significantly different. CONCLUSION: When evaluated systematically, septal venous channel perforation may be encountered commonly after LBBAP. The fiducial reference framework described using fluoroscopic imaging identified salient associated findings. This may be addressed with lead repositioning to a more inferior location and is not associated with adverse consequence acutely or in early follow-up.


Asunto(s)
Estimulación Cardíaca Artificial , Humanos , Masculino , Femenino , Estudios Prospectivos , Persona de Mediana Edad , Anciano , Estimulación Cardíaca Artificial/métodos , Tabique Interventricular/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/diagnóstico por imagen , Resultado del Tratamiento , Factores de Riesgo , Fascículo Atrioventricular/fisiopatología , Tabiques Cardíacos/diagnóstico por imagen , Medios de Contraste , Fluoroscopía , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/etiología
5.
Pacing Clin Electrophysiol ; 47(1): 149-155, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38055612

RESUMEN

BACKGROUND: Conventional right ventricle (RV) pacemaker stimulation has been associated with worse clinical outcomes in patients with cardiac amyloidosis (CA). Left bundle branch area pacing (LABPP) has been suggested as a promising alternative. We sought to assess the safety, feasibility, and outcomes of LABPP in patients with CA. METHODS: We retrospectively analyzed echocardiography and pacing parameters and clinical outcomes in 23 consecutive patients with CA and LBBAP implanted from June 2020 to October 2022. RESULTS: LBBAP was successfully performed in 22 over 23 patients (19 male, 78.6 ± 11.7 years, 20 ATTR, mean LVEF 45.5 ± 16.2%). After the procedure, 9 patients showed Qr pattern and 11 a qR pattern in V1 on ECG. Average procedure time was 67 ± 28 min. After 7.7 ± 5.2 months follow-up, no procedure-related complications had occurred. Although, a significant reduction in QRS width (p = .001) was achieved, we did not observe significant changes in LVEF and Nt ProBNP at 6 months of follow-up. Pacing parameters were stable during follow-up: LBB capture threshold and R wave amplitude were 1.0 ±  0.5 V and 10.6 ± 6.0 mV versus 0.8 ±  0.1 V, p = .21 and 10.6 ± 5.1 mV (p = .985) at follow up. CONCLUSION: LBBAP is safe and feasible pacing technique for patients with CA. LBBAP is associated with significant narrowing of QRSd without worsening in LVEF and Nt-proBNP.


Asunto(s)
Amiloidosis , Tabique Interventricular , Humanos , Masculino , Estudios de Factibilidad , Estudios Retrospectivos , Amiloidosis/terapia , Ventrículos Cardíacos , Electrocardiografía , Estimulación Cardíaca Artificial , Fascículo Atrioventricular , Resultado del Tratamiento
6.
Pacing Clin Electrophysiol ; 47(4): 525-532, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38430478

RESUMEN

INTRODUCTION: The optimal slow pathway (SP) ablation site in cases with an inferiorly located His bundle (HIS) remains unclear. METHODS AND RESULTS: In 45 patients with atrioventricular nodal reentrant tachycardia, the relationship between the HIS location and successful SP ablation site was assessed in electroanatomical maps. We assessed the location of the SP ablation site relative to the bottom of the coronary sinus ostium in the superior-to-inferior (SPSI), anterior-to-posterior (SPAP), and right-to-left (SPRL) directions. The HIS location was assessed in the same manner. The HIS location in the superior-to-inferior direction (HISSI), SPSI, SPAP, and SPRL were 17.7 ± 6.4, 1.7 ± 6.4, 13.6 ± 12.3, and -1.0 ± 13.0 mm, respectively. The HISSI was positively correlated with SPSI (R2 = 0.62; P < .01) and SPAP (R2 = 0.22; P < .01), whereas it was not correlated with SPRL (R2 = 0.01; P = .65). The distance between the HIS and SP ablation site was 17.7 ± 6.4 mm and was not affected by the location of HIS. The ratio of the amplitudes of atrial and ventricular potential recorded at the SP ablation site did not differ between the high HIS group (HISSI ≥ 13 mm) and low HIS group (HISSI < 13 mm) (0.10 ± 0.06 vs. 0.10 ± 0.06; P = .38). CONCLUSION: In cases with an inferiorly located HIS, SP ablation should be performed at a lower and more posterior site than in typical cases.


Asunto(s)
Taquicardia por Reentrada en el Nodo Atrioventricular , Tabique Interventricular , Humanos , Fascículo Atrioventricular/cirugía , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Ventrículos Cardíacos , Atrios Cardíacos
7.
Pacing Clin Electrophysiol ; 47(1): 101-105, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37158275

RESUMEN

Coronary artery lesions related to pacemaker implantation are rare complications. With the increasing adoption of the technique of permanent transseptal pacing of the left bundle branch area pacing (LBBAP), an increase in the incidence of these complications may be expected. We report two cases of coronary lesions after permanent transeptal pacing of the LBBAP: the first with a small coronary artery fistula, and the second with an extrinsic coronary compression. Both complications occurred with stylet-driven pacing leads with extendable helix. In the first case, since the shunt volume was small and no major complications were reported, the patient was treated conservatively with good outcome. The second case required lead repositioning due to acute decompensated heart failure.


Asunto(s)
Insuficiencia Cardíaca , Tabique Interventricular , Humanos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Vasos Coronarios , Electrocardiografía/métodos , Sistema de Conducción Cardíaco , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/prevención & control , Fascículo Atrioventricular , Resultado del Tratamiento
8.
Artículo en Inglés | MEDLINE | ID: mdl-38522878

RESUMEN

Ventricular septation of the double-inlet ventricle is a largely abandoned operation due to poor historical outcomes. However, there has been renewed interest in septation as an alternative to Fontan palliation given its long-term sequelae. As one of the few centers to revisit septation in the early 1990s, our institution has long-term data on a series of patients with a double-inlet ventricle who underwent biventricular repair. This manuscript is a summary of our approach to staged septation of the double-inlet ventricle, with a focus on patient selection criteria, surgical techniques, perioperative considerations on timing of interventions, and long-term results. We believe that septation of the double-inlet ventricle should be reconsidered in patients with suitable anatomy in light of the known complications of Fontan palliation.


Asunto(s)
Procedimiento de Fontan , Corazón Univentricular , Tabique Interventricular , Humanos , Ventrículos Cardíacos/cirugía , Bahías , Tabique Interventricular/cirugía
10.
Echocardiography ; 41(3): e15802, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38527007

RESUMEN

The right sinus of the Valsalva aneurysm (SVA) rupturing into the right atrium (RA) and dissecting into the interventricular septum (IVS) is rare. The disease can be definitively diagnosed using two-dimensional (2D) echocardiography and color Doppler ultrasonography. Real-time biplane imaging and three-dimensional (3D) echocardiography offer new perspectives for viewing and diagnosing this disease.


Asunto(s)
Aneurisma Roto , Aneurisma de la Aorta , Disección Aórtica , Rotura de la Aorta , Seno Aórtico , Tabique Interventricular , Humanos , Aneurisma de la Aorta/complicaciones , Aneurisma de la Aorta/diagnóstico por imagen , Seno Aórtico/diagnóstico por imagen , Atrios Cardíacos/diagnóstico por imagen
11.
Adv Exp Med Biol ; 1441: 535-549, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38884730

RESUMEN

Ventricular septation is a complex process which involves the major genes of cardiac development, acting on myocardial cells from first and second heart fields, and on mesenchymal cells from endocardial cushions. These genes, coding for transcription factors, interact with each other, and their differential expression conditions the severity of the phenotype. In this chapter, we will describe the formation of the ventricular septum in the normal heart, as well as the molecular mechanisms leading to the four main anatomic types of ventricular septal defects: outlet, inlet, muscular, and central perimembranous, resulting from failure of development of the different parts of the ventricular septum. Experiments on animal models, particularly transgenic mouse lines, have helped us to decipher the molecular determinants of ventricular septation. However, a precise description of the anatomic phenotypes found in these models is mandatory to achieve a better comprehension of the complex mechanisms responsible for the various types of VSDs.


Asunto(s)
Modelos Animales de Enfermedad , Defectos del Tabique Interventricular , Animales , Humanos , Ratones , Regulación del Desarrollo de la Expresión Génica , Defectos del Tabique Interventricular/genética , Defectos del Tabique Interventricular/patología , Defectos del Tabique Interventricular/metabolismo , Ratones Transgénicos , Transducción de Señal/genética , Tabique Interventricular/patología , Tabique Interventricular/metabolismo , Tabique Interventricular/embriología
12.
J Electrocardiol ; 83: 21-25, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38241779

RESUMEN

BACKGROUND: The left bundle branch block (LBBB) is associated with ventricular septal mid-wall fibrosis (SMF) in patients with dilated cardiomyopathy (DCM). However, whether LBBB is also associated with SMF in patients with preserved left ventricular ejection fraction (LVEF) remains unclear. METHODS: We performed a retrospective study of 210 patients with preserved LVEF (male, n = 116; female, n = 94; mean age, 44 ± 17 years). LBBB was defined as QRS duration ≥140 ms for men or ≥ 130 ms for women, QS or rS in V1-V2, mid-QRS notching or slurring in at least two leads (V1, V2, V5, V6, I, and aVL). SMF determined by late gadolinium-enhancement cardiovascular magnetic resonance was defined as stripe-like or patchy mid-myocardial hyper-enhancement in the interventricular septal segments. RESULTS: SMF was detected in 24.8% (52/210) of these patients. The proportion of patients with SMF with LBBB was higher than the proportion of patients with SMF without LBBB (58.3% vs. 20.4%; P < 0.001). In the forward multivariate logistic analysis, LBBB (OR, 4.399; 95% CI, 1.774-10.904; P = 0.001) and age (OR, 1.028; 95% CI, 1.006-1.051; P = 0.011) were independently associated with SMF. The presence of LBBB showed a sensitivity of 27%%, specificity of 94%, positive predictive value of 58%%, and negative predictive value of 80% for the detection of SMF. CONCLUSION: LBBB was significantly associated with SMF in hospitalized patients with preserved LVEF. Screening with a resting 12­lead ECG may help to identify patients who are at a high risk of the presence of SMF.


Asunto(s)
Función Ventricular Izquierda , Tabique Interventricular , Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Volumen Sistólico , Bloqueo de Rama/diagnóstico , Electrocardiografía , Estudios Retrospectivos , Fibrosis
13.
Pediatr Cardiol ; 45(3): 681-689, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36840807

RESUMEN

This study aimed to investigate the feasibility and effectiveness of left bundle branch area pacing (LBBaP) in young children. From September 2020 to May 2021, a total of 31 children (≤ 7 years) with complete atrioventricular block were included. All patients were scheduled to undergo LBBaP. Pacing parameters, and cardiac function and synchrony were evaluated during follow-up. LBBaP succeeded in 21 children (3.3 ± 2.1 years old), with a success rate of 70.9%. LBBaP failed in nine children, who eventually received right ventricular septal pacing (RVSP). The average postoperative QRS duration in patients of LBBaP group was narrower than that of RVSP group: 100.9 ± 9.1 versus 114.2 ± 11.9 ms (P = 0.002). The median follow-up duration was 12 [interquartile range (IQR) 6-15] months. At last time of follow-up, the capture threshold of ventricular electrode in patients of LBBaP group were significantly lower than that of RVSP group (0.70 ± 0.25 versus 1.39 ± 0.94 V, P = 0.011). The echo-left ventricular ejection fraction (LVEF) in patients in the LBBaP group was better than that in the RVSP group (66.1 ± 3.3 versus 63.1 ± 2.2%, P = 0.025). LBBaP can be safely and effectively administered in young children. Satisfactory pacing parameters, and narrow QRS durations were obtained.


Asunto(s)
Función Ventricular Izquierda , Tabique Interventricular , Niño , Humanos , Preescolar , Lactante , Estudios de Factibilidad , Volumen Sistólico , Ventrículos Cardíacos/diagnóstico por imagen
14.
Pediatr Cardiol ; 45(2): 446-451, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37955720

RESUMEN

Absent pulmonary valve with tricuspid atresia or tricuspid stenosis (APV-TA/TS) is an extremely rare congenital heart defect associated with significant morbidity and mortality. Compared to Tetralogy of Fallot with Absent Pulmonary Valve Syndrome, branch pulmonary arteries are not typically significantly dilated. We present the case of a newborn male prenatally diagnosed APV-TA with intact ventricular septum (IVS) and nearly discontinuous branch pulmonary arteries, the surgical strategy employed, and the salient hemodynamic factors considered in the medical decision-making.


Asunto(s)
Cardiopatías Congénitas , Atresia Pulmonar , Válvula Pulmonar , Atresia Tricúspide , Tabique Interventricular , Recién Nacido , Masculino , Humanos , Atresia Tricúspide/diagnóstico por imagen , Atresia Tricúspide/cirugía , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/anomalías , Arteria Pulmonar/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Atresia Pulmonar/diagnóstico por imagen , Atresia Pulmonar/cirugía
15.
Cardiol Young ; 34(1): 189-191, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38031460

RESUMEN

Coronary cameral fistula is a rare congenital anomaly and clinical presentation depends on the location of the defect, degree of shunting, and associated complications. We present a case of coronary cameral fistula where segmental analysis by echocardiogram helped us to avoid misdiagnosis as a ventricular septal defect.


Asunto(s)
Enfermedad de la Arteria Coronaria , Fístula , Cardiopatías Congénitas , Defectos del Tabique Interventricular , Tabique Interventricular , Humanos , Tabique Interventricular/diagnóstico por imagen , Defectos del Tabique Interventricular/diagnóstico por imagen
16.
Cardiol Young ; 34(1): 120-125, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37231590

RESUMEN

Pulmonary atresia with an intact ventricular septum is characterised by heterogeneity in right ventricle morphology and coronary anatomy. In some cases, the presence of ventriculocoronary connections may promote coronary artery stenosis or interruption, and aortic diastolic pressure may not be sufficient to drive coronary blood flow. This requires a correct evaluation (currently done by angiography) which depends on whether the patient can be offered decompression of the right ventricle. To date, there is no objective method to do so, so we designed a percutaneous, transitory technique with the purpose of occluding the transtricuspid anterograde flow. The manoeuverer was performed in a 25-day-old female with pulmonary atresia with intact ventricular septum, right ventricle at suprasystemic level, and selective coronarography was not conclusive, the anterior descendant with stenosis in its middle third and from this point, thinner with to-fro flow. Occlusion was performed with a balloon catheter. We re-evaluated the coronary flow and the normalised anterior descendant flow. We hope that with this new method, we can give a more accurate diagnosis and determine the cases in which the coronary circulation is truly not right ventricle dependent to offer a greater number of patients biventricular or 1.5 ventricular repairs and thereby improve their quality of life and survival, the ones that turn out to be right ventricular dependant; offer them an early reference for cardiac transplant or in case it is not available to consider univentricular palliation knowing that this probably would not reduce the risk of ischaemia and/or death over time.


Asunto(s)
Cardiopatías Congénitas , Atresia Pulmonar , Tabique Interventricular , Humanos , Femenino , Atresia Pulmonar/diagnóstico por imagen , Atresia Pulmonar/cirugía , Tabique Interventricular/diagnóstico por imagen , Tabique Interventricular/cirugía , Ventrículos Cardíacos , Calidad de Vida , Resultado del Tratamiento , Circulación Coronaria
17.
Cardiol Young ; 34(1): 1-10, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38037810

RESUMEN

Surgical repair of channels between the ventricles is enhanced when the surgeon knows precisely where to place a patch, or baffle, so as to restore septal integrity. The paediatric cardiologist should provide the necessary information. Communication will be enhanced if the same words are used to account for the structures in question. Currently, however, the same term, namely "ventricular septal defect," is used to account for markedly different areas within the heart. Closure of perimembranous defects found in hearts with concordant or discordant ventriculo-arterial connections restores the integrity of the ventricular septum, at the same time separating the systemic and pulmonary blood streams. When both arterial trunks arise from the right ventricle, in contrast, the surgeon when placing a baffle so as to separate the blood streams, does not close the channel most frequently described as the "ventricular septal defect." In this review, we show that the perimembranous lesions as found in hearts with concordant or discordant ventriculo-arterial connections are the right ventricular entrances to the areas subtended beneath the hinges of the leaflets of the aortic or pulmonary valves. When both arterial trunks arise from the right ventricle, and the channel between the ventricles is directly subaortic, then the channel termed the "ventricular septal defect" is the left ventricular entrance to the comparable space subtended beneath the aortic root. We argue that recognition of these fundamental anatomical differences enhances the appreciation of the underlying morphology of the various lesions that reflect transfer, during cardiac development, of the aortic root from the morphologically right to the morphologically left ventricle.


Asunto(s)
Defectos del Tabique Interventricular , Transposición de los Grandes Vasos , Tabique Interventricular , Niño , Humanos , Defectos del Tabique Interventricular/cirugía , Defectos del Tabique Interventricular/patología , Ventrículos Cardíacos/cirugía , Aorta/patología
18.
Pediatr Emerg Care ; 40(6): 434-437, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38316020

RESUMEN

BACKGROUND: Hypertrophic cardiomyopathy is a genetic, life-threatening cardiovascular disease that often goes unidentified in pediatric patients. Patients are often asymptomatic and neither history or physical examination are reliable to detect the disease. The only reliable method to diagnose hypertrophic cardiomyopathy is with echocardiography to look at interventricular septal thickness. Emerging literature has shown that cardiac point-of-care ultrasound (POCUS) performed by pediatric emergency medicine (PEM) physicians is as effective and accurate compared with cardiac echocardiography performed by pediatric cardiologists. OBJECTIVE: The objective of the study was to determine the diagnostic accuracy of POCUS performed by ultrasound-trained PEM physicians in measuring the interventricular septum end diastole (IVSd) thickness in the pediatric emergency department. METHODS: We conducted a prospective, single-center, observational, diagnostic accuracy study to examine the diagnostic accuracy of POCUS in measuring IVSd thickness in pediatric patients who presented to the pediatric emergency department with symptoms that prompted a cardiac POCUS. Cardiac POCUS findings were interpreted by a PEM physician at the bedside and retrospectively by a pediatric cardiologist. Diagnostic concordance of the measurements obtained by the PEM physician and cardiologist was assessed. RESULTS: Forty-eight patients were enrolled. Median patient age was 13.4 years. There was excellent diagnostic agreement on the measurement of the IVSd thickness between PEM physicians and the pediatric cardiologist (81.25% of cases; 39/48). Disagreement was seen in 18.75% of the cases (9/48). The mean error of disagreement was -0.32, with a 95% confidence interval of -0.37 to -0.28. Overall, the mean error of both agreement and disagreement was -0.046, with 95% confidence interval of -0.08 to -0.01 and P value of 0.008. CONCLUSIONS: Point-of-care ultrasound performed by ultrasound-trained PEM physicians to measure pediatric IVSd thickness has a high diagnostic accuracy with excellent agreement with a pediatric cardiologist.


Asunto(s)
Cardiomiopatía Hipertrófica , Ecocardiografía , Servicio de Urgencia en Hospital , Sistemas de Atención de Punto , Humanos , Estudios Prospectivos , Masculino , Femenino , Niño , Adolescente , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Ecocardiografía/métodos , Tabique Interventricular/diagnóstico por imagen , Preescolar , Lactante
19.
Semin Cell Dev Biol ; 110: 2-10, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32418658

RESUMEN

An essential role for cilia in the pathogenesis of congenital heart disease (CHD) has emerged from findings of a large-scale mouse forward genetic screen. High throughput screening with fetal ultrasound imaging followed by whole exome sequencing analysis recovered a preponderance of cilia related genes and cilia transduced cell signaling genes among mutations identified to cause CHD. The perturbation of left-right patterning in CHD pathogenesis is suggested by the association of CHD with heterotaxy, but also by the finding of the co-occurrence of laterality defects with CHD in birth defect registries. Many of the cilia and cilia cell signaling genes recovered were found to be related to Hedgehog signaling. Studies in mice showed cilia transduced hedgehog signaling coordinates left-right patterning with heart looping and differentiation of the heart tube. Cilia transduced Shh signaling also regulates later events in heart development, including outflow tract septation and formation of the atrioventricular septum. More recent work has shown mutations in cilia related genes may also contribute to valve disease that largely manifest in adult life. Overall, these and other findings show cilia play an important role in CHD and also in more common valve diseases.


Asunto(s)
Cilios/metabolismo , Cardiopatías Congénitas/genética , Miocardio/metabolismo , Tabique Interventricular/metabolismo , Vía de Señalización Wnt/genética , Animales , Tipificación del Cuerpo/genética , Cilios/patología , Cilios/ultraestructura , Modelos Animales de Enfermedad , Feto , Regulación de la Expresión Génica , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/metabolismo , Cardiopatías Congénitas/patología , Humanos , Cinesinas/genética , Cinesinas/metabolismo , Proteína 2 Relacionada con Receptor de Lipoproteína de Baja Densidad/genética , Proteína 2 Relacionada con Receptor de Lipoproteína de Baja Densidad/metabolismo , Proteínas de la Membrana/genética , Proteínas de la Membrana/metabolismo , Ratones , Miocardio/patología , Proteínas Represoras/genética , Proteínas Represoras/metabolismo , Ultrasonografía Prenatal , Tabique Interventricular/diagnóstico por imagen , Tabique Interventricular/patología , Secuenciación del Exoma
20.
J Cardiovasc Electrophysiol ; 34(9): 1944-1950, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37565366

RESUMEN

INTRODUCTION: Current delivery tools were not designed for left bundle branch area pacing (LBBAP). Challenges using these tools include lack of reach into the right ventricle and poor support for the lead to penetrate the interventricular septum. Concerns using stylet-driven leads (SDL) for LBBAP have been previously highlighted. Knowledge and the technical know-how of using SDL for LBBAP need to be evaluated in a fair and consistent manner. A stepwise approach is devised for use of Agilis HisProTM steerable catheter with Tendril STS Model 2088TC lead for LBBAP and evaluated for safety and reproducibility. METHODS: Consecutive patients undergoing LBBAP using the stepwise approach with Agilis HisProTM steerable catheter were analyzed. The safety, efficacy and reproducibility of the technique were evaluated. The lead parameters were analyzed in the immediate (1 day) and short-term period (3-6 months) post implantation. RESULTS: LBBAP was attempted in 41 patients using the stepwise approach of which 37 (90.7%) were successful. The lead parameters were stable in the immediate and short-term post implantation in all our patients. There was no significant difference between the group of patients with multiple repositioning of the lead compared to those successful at the 1st attempt. There were no acute or short-term lead and procedural complications. CONCLUSION: A stepwise and systematic approach using the Agilis HisProTM steerable catheter and proper handling of the Tendril STS Model 2088TC stylet-driven lead is an important part of the armamentarium to deliver LBBAP in a practical, effective and reproducible manner.


Asunto(s)
Catéteres , Tabique Interventricular , Humanos , Reproducibilidad de los Resultados , Ventrículos Cardíacos , Estimulación Cardíaca Artificial , Electrocardiografía , Fascículo Atrioventricular , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS