Detección de efectos adversos en cirugía general mediante la aplicación de la metodología «Trigger Tool» / Detection of adverse events in general surgery using the « Trigger Tool» methodology
Pérez Zapata, Ana Isabel; Gutiérrez Samaniego, María; Rodríguez Cuéllar, Elías; Andrés Esteban, Eva María; Gómez de la Cámara, Agustín; Ruiz López, Pedro.
Cir. Esp. (Ed. impr.);
93(2): 84-90, feb. 2015. graf, tab
Artículo
en Español
| IBECS (España) | ID: ibc-132534
INTRODUCCIÓN:
La cirugía supone una de las áreas de alto riesgo para la aparición de efectos adversos (EA). El objetivo de este estudio es conocer el porcentaje de EA en hospitalización que se detectan mediante la metodología «Global Trigger Tool» en pacientes de cirugía general, las características de los mismos y la validez de la herramienta. MATERIAL YMÉTODOS:
Estudio retrospectivo, observacional y descriptivo sobre pacientes ingresados en cirugía general de un hospital de tercer nivel, sometidos a intervención quirúrgica durante el año 2012. La identificación de EA se lleva a cabo mediante una revisión de historias clínicas empleando una adaptación de la metodología «Global Trigger Tool» Una vez identificado el EA, se le asignó una categoría de daño y se determinó el grado en el que este podría haber sido evitado así como su relación con el procedimiento quirúrgico.RESULTADOS:
La prevalencia de EA fue de 36,8%. Con un número de EA por paciente de 0,5. El 56,2% se consideraron evitables. Y un 69,3% se relacionaron directamente con el procedimiento quirúrgico. La herramienta demostró una sensibilidad del 86% y una especificidad del 93,6%. El valor predictivo positivo fue de 89%, el valor predictivo negativo de 92%.CONCLUSIONES:
La prevalencia de EA es más alta de lo estimado en otros estudios. La mayoría de los EA detectados están relacionados con el procedimiento quirúrgico, y más de la mitad son evitables. La metodología «Global Trigger Tool» adaptada ha demostrado ser altamente eficaz y eficiente para la detección de EA en cirugía, identificando todos los EA graves y con pocos falsos negativosINTRODUCTION:
Surgery is one of the high-risk areas for the occurrence of adverse events (AE). The purpose of this study is to know the percentage of hospitalisation-related AE that are detected by the «Global Trigger Tool» methodology in surgical patients, their characteristics and the tool validity. MATERIAL ANDMETHODS:
Retrospective, observational study on patients admitted to a general surgery department, who underwent a surgical operation in a third level hospital during the year 2012. The identification of AE was carried out by patient record review using an adaptation of «Global Trigger Tool» methodology. Once an AE was identified, a harm category was assigned, including the grade in which the AE could have been avoided and its relation with the surgical procedure.RESULTS:
The prevalence of AE was 36,8%. There were 0,5 AE per patient. 56,2% were deemed preventable. 69,3% were directly related to the surgical procedure. The tool had a sensitivity of 86% and a specificity of 93,6%. The positive predictive value was 89% and the negative predictive value 92%.CONCLUSIONS:
Prevalence of AE is greater than the estimate of other studies. In most cases the AE detected were related to the surgical procedure and more than half were also preventable. The adapted «Global Trigger Tool» methodology has demonstrated to be highly effective and efficient for detecting AE in surgical patients, identifying all the serious AE with few false negativeresults:
Asunto(s)
Humanos /efectos adversos Seguridad del Paciente/estadística & datos numéricos Complicaciones Posoperatorias/epidemiología Complicaciones Intraoperatorias/epidemiología Administración de la Seguridad/organización & administración Factores de Riesgo
Biblioteca responsable:
ES1.1
Ubicación: BNCS
powered by iAHx-2.18-89
Portal de Búsqueda de la BVS España