Your browser doesn't support javascript.
loading
Usefulness of a novel "response score" to predict hemodynamic and clinical outcome from cardiac resynchronization therapy.
Heist, E Kevin; Taub, Cynthia; Fan, Dali; Arzola-Castaner, Daniel; Alabiad, Chrisfouad R; Reddy, Vivek Y; Mansour, Moussa; Mela, Theofanie; Picard, Michael H; Ruskin, Jeremy N; Singh, Jagmeet P.
Afiliación
  • Heist EK; Cardiac Arrhythmia Service, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
Am J Cardiol ; 97(12): 1732-6, 2006 Jun 15.
Article en En | MEDLINE | ID: mdl-16765123
Cardiac resynchronization therapy (CRT) is an important treatment for patients with congestive heart failure and ventricular dyssynchrony, but response to CRT is highly variable. We assessed whether a scoring system that encompasses a combination of patient selection and procedural variables would improve prediction of CRT response. Thirty-nine patients who underwent CRT with echocardiographic assessment of baseline contractility and left ventricular (LV) dyssynchrony, intraprocedural assessment of LV lead electrical delay, and postprocedural chest radiography were included. Baseline LV dyssynchrony was measured by Doppler tissue velocity imaging as the maximum time difference between peak systolic velocity of anterior, lateral, posterior, and septal walls. The hemodynamic effect of CRT was measured by Doppler analysis of mitral regurgitation as percent change in maximal +dP/dt (DeltadP/dt) with CRT on versus off. Acute responders to CRT were defined as Deltadp/dt >or=25%. Clinical response was measured as a combined end point of hospitalization for heart failure and all-cause mortality. A 4-point response score was generated using variables associated with DeltadP/dt and assigning 1 point for a dorsoventral LV/right ventricular interlead distance>10 cm, 1 point for a LV lead electrical delay>or=50%, 1 point for a baseline maximum +dP/dt <600 mm Hg/s, and 1 point for a maximum time difference>100 ms. In conclusion, there was a significant association between response score (0 to 4 points) and acute hemodynamic response to CRT (p<0.0001). Kaplan-Meier analysis associated a higher response score with improved 12-month event-free survival after CRT implantation (p=0.0019).
Asunto(s)
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Estimulación Cardíaca Artificial / Evaluación de Resultado en la Atención de Salud / Insuficiencia Cardíaca / Hemodinámica Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: Am J Cardiol Año: 2006 Tipo del documento: Article País de afiliación: Estados Unidos
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Estimulación Cardíaca Artificial / Evaluación de Resultado en la Atención de Salud / Insuficiencia Cardíaca / Hemodinámica Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: Am J Cardiol Año: 2006 Tipo del documento: Article País de afiliación: Estados Unidos