Your browser doesn't support javascript.
loading
The incorporation of the concept of minimum RBE (RbEmin) into the linear-quadratic model and the potential for improved radiobiological analysis of high-LET treatments.
Carabe-Fernandez, Alejandro; Dale, Roger G; Jones, Bleddyn.
Afiliación
  • Carabe-Fernandez A; Department of Radiation Physics and Radiobiology, Imperial College School of Medicine, Hammersmith Hospitals NHS Trust, Charing Cross Hospital, London, UK. a.carabe@imperial.ac.uk
Int J Radiat Biol ; 83(1): 27-39, 2007 Jan.
Article en En | MEDLINE | ID: mdl-17357437
ABSTRACT

PURPOSE:

The formulation of relative biological effectiveness (RBE) for high linear energy transfer (high-LET) radiation treatments is revisited. The effects of changed production of sub-lethal damage with varying LET is now considered via the RBEmin concept, where RBEmin represents the lower limit to which RBE tends at high doses per fraction. MATERIALS AND

METHODS:

An existing linear-quadratic formulation for calculating RBE variations with fractional dose for high-LET radiations is modified to incorporate the twin concepts of RBEmax (which represents the value of RBE at an effective dose-per-fraction of 0 Gy) and RBEmin.

RESULTS:

Fits of the model to data showed RBEmin values in the range of 0.1- 2.27. In all cases the raw data was a better statistical fit to the model which included RBEmin, although this was only very highly significant in one case. In the case of the mouse oesophagus it is shown that, if change in the beta-radiosensitivity coefficient with LET is considered as trivial, an underestimation > 5% in RBE can be expected at X-ray doses of 2 Gy/fraction if RBEmin is not considered. To ensure that the results were not biased by the statistical method used to obtain the parameter values relevant to this analysis (i.e., using fraction-size effect or Fe-plots), an alternative method was used which provided very similar correlation with the data.

CONCLUSIONS:

If the production of sublethal damage is considered independent of LET, there will be a risk that non-corrected evaluation of RBE will lead to an over- or under-estimate of RBE at low doses per fractions (the clinically relevant region).
Asunto(s)
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Transferencia Lineal de Energía / Fraccionamiento de la Dosis de Radiación / Esófago / Terapia de Protones / Pulmón Límite: Animals Idioma: En Revista: Int J Radiat Biol Asunto de la revista: RADIOLOGIA Año: 2007 Tipo del documento: Article País de afiliación: Reino Unido
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Transferencia Lineal de Energía / Fraccionamiento de la Dosis de Radiación / Esófago / Terapia de Protones / Pulmón Límite: Animals Idioma: En Revista: Int J Radiat Biol Asunto de la revista: RADIOLOGIA Año: 2007 Tipo del documento: Article País de afiliación: Reino Unido