Your browser doesn't support javascript.
loading
Development of parallel line analysis criteria for recombinant adenovirus potency assay and definition of a unit of potency.
Ogawa, Yasushi; Fawaz, Farah; Reyes, Candice; Lai, Julie; Pungor, Erno.
Afiliación
  • Ogawa Y; Analytical Development, Global CMC Development Biologics, Berlex, Inc., Richmond, CA 94804, USA. yogawa@pacbell.net
PDA J Pharm Sci Technol ; 61(3): 183-93, 2007.
Article en En | MEDLINE | ID: mdl-17722485
ABSTRACT
Parameter settings of a parallel line analysis procedure were defined by applying statistical analysis procedures to the absorbance data from a cell-based potency bioassay for a recombinant adenovirus, Adenovirus 5 Fibroblast Growth Factor-4 (Ad5FGF-4). The parallel line analysis was performed with a commercially available software, PLA 1.2. The software performs Dixon outlier test on replicates of the absorbance data, performs linear regression analysis to define linear region of the absorbance data, and tests parallelism between the linear regions of standard and sample. Width of Fiducial limit, expressed as a percent of the measured potency, was developed as a criterion for rejection of the assay data and to significantly improve the reliability of the assay results. With the linear range-finding criteria of the software set to a minimum of 5 consecutive dilutions and best statistical outcome, and in combination with the Fiducial limit width acceptance criterion of <135%, 13% of the assay results were rejected. With these criteria applied, the assay was found to be linear over the range of 0.25 to 4 relative potency units, defined as the potency of the sample normalized to the potency of Ad5FGF-4 standard containing 6 x 10(6) adenovirus particles/mL. The overall precision of the assay was estimated to be 52%. Without the application of Fiducial limit width criterion, the assay results were not linear over the range, and an overall precision of 76% was calculated from the data. An absolute unit of potency for the assay was defined by using the parallel line analysis procedure as the amount of Ad5FGF-4 that results in an absorbance value that is 121% of the average absorbance readings of the wells containing cells not infected with the adenovirus.
Asunto(s)
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Bioensayo / Adenoviridae / Factor 4 de Crecimiento de Fibroblastos Idioma: En Revista: PDA J Pharm Sci Technol Asunto de la revista: FARMACIA / FARMACOLOGIA Año: 2007 Tipo del documento: Article País de afiliación: Estados Unidos
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Bioensayo / Adenoviridae / Factor 4 de Crecimiento de Fibroblastos Idioma: En Revista: PDA J Pharm Sci Technol Asunto de la revista: FARMACIA / FARMACOLOGIA Año: 2007 Tipo del documento: Article País de afiliación: Estados Unidos