Your browser doesn't support javascript.
loading
Investigation of folic acid stability in fortified instant noodles by use of capillary electrophoresis and reversed-phase high performance liquid chromatography.
Hau Fung Cheung, Rodney; Morrison, Paul D; Small, Darryl M; Marriott, Philip J.
Afiliación
  • Hau Fung Cheung R; Applied Chemistry, School of Applied Sciences, RMIT University, GPO Box 2476V, Melbourne 3001, Victoria, Australia.
J Chromatogr A ; 1213(1): 93-9, 2008 Dec 05.
Article en En | MEDLINE | ID: mdl-18930464
A single enzyme treatment with alpha-amylase, prior to the quantification of added folic acid (FA) in fortified instant fried Asian noodles with analysis performed by capillary zone electrophoresis (CZE) and reversed-phase high performance liquid chromatography (RP-HPLC) with UV detection, is described. The method was validated and optimized for capillary electrophoresis (CE) with separation achieved using a 8 mM phosphate-12 mM borate run buffer with 5% MeOH at pH 9.5. FA was well separated from matrix components with nicotinic acid (NA) employed as an internal standard. In a comparative study, separation of FA was performed using HPLC with a mobile phase consisting of 27% MeOH (v/v) in aqueous potassium phosphate buffer (3.5 mM KH(2)PO(4) and 3.2 mM K(2)HPO(4)), pH 8.5, and containing 5 mM tetrabutylammonium dihydrogen phosphate as an ion-pairing agent. For both methods, excellent results were obtained for various analytical parameters including linearity, accuracy and precision. The limit of detection was calculated to be 2.2 mg/L for CE without sample stacking and 0.10 mg/L with high performance liquid chromatography (HPLC). Sample extraction involved homogenization and enzymatic extraction with alpha-amylase. Results indicated that FA was stable during four main stages of instant fried noodle manufacturing (dough crumbs, cut sheets, steaming and frying).
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Alimentos Fortificados / Cromatografía Líquida de Alta Presión / Electroforesis Capilar / Ácido Fólico / Análisis de los Alimentos Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Chromatogr A Año: 2008 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Alimentos Fortificados / Cromatografía Líquida de Alta Presión / Electroforesis Capilar / Ácido Fólico / Análisis de los Alimentos Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Chromatogr A Año: 2008 Tipo del documento: Article País de afiliación: Australia