Your browser doesn't support javascript.
loading
Performance of the resurfaced hip. Part 1: the influence of the prosthesis size and positioning on the remodelling and fracture of the femoral neck.
Dickinson, A S; Taylor, A C; Browne, M.
Afiliación
  • Dickinson AS; Bioengineering Science Research Group, University of Southampton, Highfield, Southampton, UK. alex.dickinson@soton.ac.uk
Proc Inst Mech Eng H ; 224(3): 427-39, 2010.
Article en En | MEDLINE | ID: mdl-20408488
Hip resurfacing is an established treatment for osteoarthritis in young active patients. Failure modes include femoral neck fracture and prosthesis loosening, which may be associated with medium-term bone adaptation, including femoral neck narrowing and densification around the prosthesis stem. Finite element modelling was used to indicate the effects of prosthesis sizing and positioning on the bone remodelling and fracture strength under a range of normal and traumatic loads, with the aim of understanding these failure modes better. The simulations predicted increased superior femoral neck stress shielding in young patients with small prostheses, which required shortening of the femoral neck to give an acceptable implant-bone interface. However, with a larger prosthesis, natural femoral head centre recreation in the implanted state was possible; therefore stress shielding was restricted to the prosthesis interior, and its extent was less sensitive to prosthesis orientation. With valgus orientation, the implanted neck strength was, at worst, within 3 per cent of its intact strength. The study suggests that femoral neck narrowing may be linked to a reduction in the horizontal femoral offset, occurring if the prosthesis is excessively undersized. As such, hip resurfacing should aim to reproduce the natural femoral head centre, and, for valgus prosthesis orientation, to avoid femoral neck fracture.
Asunto(s)
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Falla de Prótesis / Remodelación Ósea / Artroplastia de Reemplazo de Cadera / Fracturas del Cuello Femoral / Prótesis de Cadera / Modelos Biológicos Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Proc Inst Mech Eng H Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2010 Tipo del documento: Article
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Falla de Prótesis / Remodelación Ósea / Artroplastia de Reemplazo de Cadera / Fracturas del Cuello Femoral / Prótesis de Cadera / Modelos Biológicos Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Proc Inst Mech Eng H Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2010 Tipo del documento: Article