Your browser doesn't support javascript.
loading
Inter- and intra-observer variability in contouring of the prostate gland on planning computed tomography and cone beam computed tomography.
Choi, Hyuck Jae; Kim, Young Seok; Lee, Se Hyung; Lee, Yu Sun; Park, Geumju; Jung, Jin Hong; Cho, Byung Chul; Park, Sung Ho; Ahn, Hanjong; Kim, Choung-Soo; Yi, Seong Yoon; Ahn, Seung Do.
Afiliación
  • Choi HJ; Department of Radiology, Asan Medical Center, College of Medicine, University of Ulsan, Seoul, Republic of Korea.
Acta Oncol ; 50(4): 539-46, 2011 May.
Article en En | MEDLINE | ID: mdl-21391773
ABSTRACT

PURPOSE:

To investigate inter-/intra-observer variability in defining the prostate by use of planning computed tomography (PCT) and cone beam CT (CBCT) with magnetic resonance image (MRI) as guidance prior to the introduction of an adaptive radiotherapy for prostate cancer. MATERIAL AND

METHODS:

We reviewed PCT and firstly acquired CBCT datasets of each ten patients with prostate cancer. Three physicians independently delineated the prostate based on PCT and CBCT with MRI as guidance, allowing determination of inter-physician variability. Two physicians repeated prostate contouring three times in total to investigate intra-physician variability. We compared delineated prostate volumes in terms of the generalized conformity index (CI(gen)), maximum variation ratio (MVR), and center of mass (COM).

RESULTS:

There were no significant inter-/intra-observer differences in the estimation of prostate volume on both PCT and CBCT. For both inter- and intra-observer variability in contouring the prostate gland, there were no significant differences in MVR between PCT and CBCT. The CI(gen) for inter-observer variability was 0.74 by PCT and 0.69 by CBCT. The CI(gen) for intra-observer variability on PCT and CBCT was 0.84 and 0.81 for observer 2 and 0.76 and 0.73 for observer 3. COM analyses showed that the greatest inter-/intra-observer variability was in the measurement of the prostate apex and base. With respect to CI(gen) and COM analysis for the inter-observer variability, more precise delineation of the prostate was possible on PCT than CBCT. More precise contouring in terms of both CI(gen) and COM was demonstrated by observer 2 than observer 3.

CONCLUSIONS:

Despite some ambiguity in apex and base level, there was a good consistency in delineating the gland on CBCT plus MRI-guided modification both among/within observer(s), without any significant difference from the consistency in defining the prostate on PCT. This study provides a framework for future studies of CBCT imaging of the prostate.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Próstata / Neoplasias de la Próstata / Planificación de la Radioterapia Asistida por Computador / Tomografía Computarizada por Rayos X / Variaciones Dependientes del Observador / Tomografía Computarizada de Haz Cónico Tipo de estudio: Prognostic_studies Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: Acta Oncol Asunto de la revista: NEOPLASIAS Año: 2011 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Próstata / Neoplasias de la Próstata / Planificación de la Radioterapia Asistida por Computador / Tomografía Computarizada por Rayos X / Variaciones Dependientes del Observador / Tomografía Computarizada de Haz Cónico Tipo de estudio: Prognostic_studies Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: Acta Oncol Asunto de la revista: NEOPLASIAS Año: 2011 Tipo del documento: Article