A simple method for measuring patient anti-globulin responses against isotypic or idiotypic determinants.
Cobbold, S P; Rebello, P R; Davies, H F; Friend, P J; Clark, M R.
Afiliación
  • Cobbold SP; Department of Pathology, Cambridge University, U.K.
J Immunol Methods ; 127(1): 19-24, 1990 Feb 20.
Article en En | MEDLINE | ID: mdl-2319138
A simple inhibition of capture enzyme-linked immunosorbent assay (IOC-ELISA) was developed which permitted the independent measurement of anti-idiotypic and anti-isotypic antiglobulins in serum samples from patients receiving therapeutic monoclonal antibodies.
Asunto(s)
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Isotipos de Inmunoglobulinas / Ensayo de Inmunoadsorción Enzimática / Anticuerpos Antiidiotipos Límite: Humans Idioma: En Revista: J Immunol Methods Año: 1990 Tipo del documento: Article