Your browser doesn't support javascript.
loading
Advantages of real time three-dimensional echocardiography in the assessment of right ventricular volumes and function in patients with pulmonary hypertension compared with conventional two-dimensional echocardiography.
Di Bello, Vitantonio; Conte, Lorenzo; Delle Donne, Maria Grazia; Giannini, Cristina; Barletta, Valentina; Fabiani, Iacopo; Palagi, Caterina; Nardi, Carmela; Dini, Frank Lloyd; Marconi, Letizia; Paggiaro, Pierluigi; Palla, Antonio; Marzilli, Mario.
Afiliación
  • Di Bello V; Cardiac Thoracic and Vascular Department, University of Pisa, Pisa, Italy. vitantonio.dibello@med.unipi.it
Echocardiography ; 30(7): 820-8, 2013 Aug.
Article en En | MEDLINE | ID: mdl-23496202
ABSTRACT

BACKGROUND:

In recent years, right ventricular (RV) function has acquired greater relevance as a clinical and prognostic marker in many physiopathological conditions. The study aims to point out the value of real time three-dimensional echocardiography (RT3DE) and tissue Doppler imaging (TDI) in the evaluation of patients affected by pulmonary hypertension (PH), compared with conventional two-dimensional (2D) echocardiography.

METHODS:

We enrolled 44 subjects affected by PH who underwent 2D and Doppler echocardiography, RT 3D Echocardiography and TDI evaluation of the RV, and a healthy control group. PH itself can induce severe functional and structural abnormalities of the RV, such as RV hypertrophy, RV dilation, and RV systolic and diastolic dysfunction.

RESULTS:

In this study, RV FAC, and TAPSE showed marked alterations in patients with PH compared to the control group (C) (RVFAC [PH] 0.29 ± 0.07 vs. [C] 0.49 ± 0.05%, P < 0.0001; TAPSE [PH] 15.3 ± 3.2 vs. [C] 21.1 ± 2.6 mm, P > 0.0001). The 3D RV end-diastolic volume was significantly higher in PH than in C (PH) (138.7 ± 25.3 vs. [C] 82.8 ± 12.5 mL, P < 0.0001] as well as 3D RV end-systolic volume (PH) (97.6 ± 21.5 vs. [C] 39.3 ± 9.5 mL, P < 0.0001). The 3D RV ejection fraction (EF) was significantly lower in the pulmonary hypertension group than in healthy subjects (31.8 ± 6.8 vs. [C] 52.5 ± 4.7%, P < 0.0001).

CONCLUSIONS:

In patients with PH, evaluation of the RV diastolic and systolic volume and EF by RT3DE has shown a higher discriminating power in comparison, respectively, with 2DRV diastolic area and the relative fractional area changes.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Volumen Sistólico / Disfunción Ventricular Derecha / Disfunción Ventricular Izquierda / Ecocardiografía Tridimensional / Hipertensión Pulmonar Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Echocardiography Asunto de la revista: CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2013 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Volumen Sistólico / Disfunción Ventricular Derecha / Disfunción Ventricular Izquierda / Ecocardiografía Tridimensional / Hipertensión Pulmonar Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Echocardiography Asunto de la revista: CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Año: 2013 Tipo del documento: Article País de afiliación: Italia