Stent-assisted coiling versus balloon remodeling of wide-neck aneurysms: comparison of angiographic outcomes.
AJNR Am J Neuroradiol
; 34(10): 1987-92, 2013 Oct.
Article
en En
| MEDLINE
| ID: mdl-23639562
BACKGROUND AND PURPOSE: Stent-assisted coiling and balloon-assisted coiling are 2 well-established techniques for treatment of wide-neck intracranial aneurysms. A direct comparative analysis of angiographic outcomes with the 2 techniques has not been available. We compare the angiographic outcomes of wide-neck aneurysms treated with stent-assisted coiling versus balloon-assisted coiling. MATERIALS AND METHODS: A retrospective review was conducted on 101 consecutive patients treated at our institution, 69 with stent-assisted coiling and 32 with balloon-assisted coiling. Two multivariate logistic regression analyses were performed to determine predictors of aneurysm obliteration and predictors of progressive aneurysm thrombosis at follow-up. RESULTS: The 2 groups were comparable with respect to all baseline characteristics with the exception of a higher proportion of ruptured aneurysms in the balloon-assisted coiling group (65.6%) than in the stent-assisted coiling group (11.5%, P < .001). Procedural complications did not differ between the stent-assisted coiling group (6%) and the balloon-assisted coiling group (9%, P = .5). The rates of complete aneurysm occlusion (Raymond score 1) at the most recent follow-up were significantly higher for the stent-assisted coiling group (75.4%) compared with the balloon-assisted coiling group (50%, P = .01). Progressive occlusion of incompletely coiled aneurysms was noted in 76.6% of aneurysms in the stent-assisted coiling group versus 42.8% in the balloon-assisted coiling group (P = .02). Retreatment rates were significantly lower with stent-assisted coiling (4.3%) versus balloon-assisted coiling (15.6%, P = .05). In multivariate analysis, stented aneurysms independently predicted both complete aneurysm obliteration and progression of occlusion. CONCLUSIONS: Stent-assisted coiling may yield lower rates of retreatment and higher rates of aneurysm obliteration and progression of occlusion at follow-up than balloon-assisted coiling with a similar morbidity rate.
Texto completo:
1
Bases de datos:
MEDLINE
Asunto principal:
Angiografía Cerebral
/
Stents
/
Aneurisma Intracraneal
/
Oclusión con Balón
Tipo de estudio:
Etiology_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Límite:
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
AJNR Am J Neuroradiol
Año:
2013
Tipo del documento:
Article