Refocused turbo spin-echo for noncontrast peripheral MR angiography.
Fielden, Samuel W; Mugler, John P; Hagspiel, Klaus D; Norton, Patrick T; Kramer, Christopher M; Meyer, Craig H.
Afiliación
  • Fielden SW; Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
J Magn Reson Imaging ; 39(6): 1468-76, 2014 Jun.
Article en En | MEDLINE | ID: mdl-24006269
ABSTRACT

PURPOSE:

To develop and assess a three-dimensional refocused turbo spin-echo (rTSE) sequence for generating peripheral angiograms. This sequence combines the rapid T2 -weighting of TSE and the better flow performance of the fully-refocused gradients of balanced steady state free precession (bSSFP), along with bSSFP-style phase alternation of refocusing radiofrequency (RF) pulses. MATERIALS AND

METHODS:

The signal behavior generated by such a sequence was explored through Bloch equation simulations. The rTSE and TSE sequences were both used to generate peripheral angiograms in nine normal volunteers. The signal to noise ratio, contrast resolution, and vessel sharpness of the resulting images were used as bases for comparison. Additionally, the rTSE sequence was applied in four patients with peripheral artery disease to preliminarily assess its efficacy in a clinical setting through quality scoring by two experienced radiologists.

RESULTS:

The rTSE's RF phase alternation approach out-performs a simple balanced-gradient CPMG (Carr-Purcell-Meiboom-Gill) -style TSE sequence in the presence of B0 and B1 inhomogeneities. In volunteers, the rTSE sequence yielded better arterial-venous contrast (0.378 ± 0.145 versus 0.155 ± 0.202; P < 0.01) and increased vessel sharpness (0.340 ± 0.034 versus 0.263 ± 0.034; P < 0.005) over TSE images. Stenoses visible in conventional angiographic images in patients were successfully imaged with the rTSE sequence; however, image quality scores in patients were lower than in volunteers (1.2 ± 0.38 versus 3.0 ± 1.0; P < 0.05).

CONCLUSION:

The rTSE sequence generates nonsubtractive, flow-independent, peripheral MR angiograms with better arterial-venous contrast and vessel sharpness in normal volunteers than a conventional TSE sequence.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Interpretación de Imagen Asistida por Computador / Enfermedades Vasculares Periféricas / Angiografía por Resonancia Magnética / Imagenología Tridimensional Límite: Adult / Aged / Female / Humans / Male Idioma: En Revista: J Magn Reson Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Interpretación de Imagen Asistida por Computador / Enfermedades Vasculares Periféricas / Angiografía por Resonancia Magnética / Imagenología Tridimensional Límite: Adult / Aged / Female / Humans / Male Idioma: En Revista: J Magn Reson Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos