Your browser doesn't support javascript.
loading
Transmission of Er:YAG laser through different dental ceramics.
Sari, Tugrul; Tuncel, Ilkin; Usumez, Aslihan; Gutknecht, Norbert.
Afiliación
  • Sari T; 1 Bezmialem Vakif University Faculty of Dentistry Department of Prosthodontics, Fatih, Istanbul/ Turkey .
Photomed Laser Surg ; 32(1): 37-41, 2014 Jan.
Article en En | MEDLINE | ID: mdl-24328609
OBJECTIVE: The aim of this study was to determine the erbium-doped yttrium aluminum garnet (Er:YAG) laser transmission ratio through different dental ceramics with different thicknesses. BACKGROUND DATA: Laser debonding procedure of adhesively luted all-ceramic restorations is based on the transmission of laser energy through the ceramic and the ablation of resin cement, because of the transmitted laser energy. METHODS: Five different dental ceramics were evaluated in this study: sintered zirconium-oxide core ceramic, monolithic zirconium-oxide ceramic, feldspathic ceramic, leucite-reinforced glass ceramic, and lithium disilicate-reinforced glass ceramic. Two ceramic discs with different thicknesses (0.5 and 1 mm) were fabricated for each group. Ceramic discs were placed between the sensor membrane of the laser power meter and the tip of the contact handpiece of an Er:YAG laser device with the aid of a custom- made acrylic holder. The transmission ratio of Er:YAG laser energy (500 mJ, 2 Hz, 1 W, 1000 µs) through different ceramic discs was measured with the power meter. Ten measurements were made for each group and the results were analyzed with two way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) tests. RESULTS: The highest transmission ratio was determined for lithium disilicate-reinforced ceramic with 0.5 mm thickness (88%) and the lowest was determined for feldspathic ceramic with 1 mm thickness (44%). The differences among the different ceramics and between the different thicknesses were significant (p<0.05). CONCLUSIONS: Ceramic type and thickness should be taken into consideration to adjust the laser irradiation parameters during laser debonding of adhesively luted all-ceramic restorations.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Cerámica / Desconsolidación Dental / Láseres de Estado Sólido Límite: Humans Idioma: En Revista: Photomed Laser Surg Año: 2014 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Cerámica / Desconsolidación Dental / Láseres de Estado Sólido Límite: Humans Idioma: En Revista: Photomed Laser Surg Año: 2014 Tipo del documento: Article