Your browser doesn't support javascript.
loading
Respiratory-gated PET/CT versus delayed images for the quantitative evaluation of lower pulmonary and hepatic lesions.
Tahari, Abdel K; Lodge, Martin A; Wahl, Richard L.
Afiliación
  • Tahari AK; Nuclear Medicine Division, Department of Radiology and Radiological Science, School of Medicine, Johns Hopkins University, Baltimore, Maryland, USA.
J Med Imaging Radiat Oncol ; 58(3): 277-82, 2014.
Article en En | MEDLINE | ID: mdl-24438486
ABSTRACT

PURPOSE:

Respiratory motion degrades fluorodeoxyglucose positron emission tomography (FDG PET) images of the lower chest and upper abdomen, as the blur introduced by breathing motion increases the apparent size of the moving tumour lesions and decreases their apparent uptake, reducing the sensitivity of PET in detection of small lesions. We assessed the role of delayed and respiratory-gated PET acquisition in the quantitative evaluation of lung and liver lesions.

METHODS:

A retrospective analysis of 64 lesions was performed. After initial non-gated whole-body PET/CT, respiratory gating was performed with 15 min in list mode. Non-gated delayed images were obtained by summing all list mode data. SUV(max) adjusted for lean body mass (SUL(max)) was measured in the initial whole-body scan, the delayed non-gated scans and the individual gated bins for each lesion. The axial z-position of SUL(max) for each lesion in five respiratory-gated bins was determined. The mean SUL of the non-pathological liver parenchyma was also recorded for each patient.

RESULTS:

Tumour lesion SUL(max) increased by an average of 34% in the delayed non-gated scan as compared with the whole-body initial scan and further by an additional 17.2% in respiratory-gated images. The maximum lesion displacement was 6.2 ± 5.0 mm.

CONCLUSION:

Delayed imaging alone substantially increases the magnitude of the SUL of liver and lung lesions as compared with standard whole-body images and may allow for a more accurate definition of the lesion's volume and localisation and improve tracer quantitation in malignant lesions in the lungs or upper abdomen. While respiratory gating provides more optimal imaging with greatest increase in SUL(max), the benefit is small, and delayed imaging appears sufficient in most cases.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Artefactos / Fluorodesoxiglucosa F18 / Tomografía de Emisión de Positrones / Técnicas de Imagen Sincronizada Respiratorias / Neoplasias Hepáticas / Neoplasias Pulmonares Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Med Imaging Radiat Oncol Asunto de la revista: DIAGNOSTICO POR IMAGEM / NEOPLASIAS / RADIOLOGIA Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Artefactos / Fluorodesoxiglucosa F18 / Tomografía de Emisión de Positrones / Técnicas de Imagen Sincronizada Respiratorias / Neoplasias Hepáticas / Neoplasias Pulmonares Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Med Imaging Radiat Oncol Asunto de la revista: DIAGNOSTICO POR IMAGEM / NEOPLASIAS / RADIOLOGIA Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos