Your browser doesn't support javascript.
loading
Reproducibility of three-dimensional gel installation sonohysterography in the assessment and classification of intrauterine abnormalities.
Nieuwenhuis, Lotte L; Bij de Vaate, Marjolein A J; Hehenkamp, Wouter J K; Heymans, Martijn W; van Baal, Marchien W M; Brölmann, Hans A M; Huirne, Judith A F.
Afiliación
  • Nieuwenhuis LL; Department of Obstetrics and Gynaecology, VU medical centre (VUmc), Amsterdam, the Netherlands. Electronic address: ll.nieuwenhuis@vumc.nl.
  • Bij de Vaate MA; Department of Obstetrics and Gynaecology, VU medical centre (VUmc), Amsterdam, the Netherlands.
  • Hehenkamp WJ; Department of Obstetrics and Gynaecology, VU medical centre (VUmc), Amsterdam, the Netherlands.
  • Heymans MW; Department of Epidemiology and Biostatistics, VU medical centre (VUmc), Amsterdam, the Netherlands.
  • van Baal MW; Department of Obstetrics and Gynaecology, Flevoziekenhuis, Almere, the Netherlands.
  • Brölmann HA; Department of Obstetrics and Gynaecology, VU medical centre (VUmc), Amsterdam, the Netherlands.
  • Huirne JA; Department of Obstetrics and Gynaecology, VU medical centre (VUmc), Amsterdam, the Netherlands.
Eur J Obstet Gynecol Reprod Biol ; 179: 141-6, 2014 Aug.
Article en En | MEDLINE | ID: mdl-24965995
ABSTRACT

OBJECTIVE:

Purpose of this study is to determine the interobserver and intraobserver variability of 3D GIS in the assessment of intrauterine abnormalities. STUDY

DESIGN:

Forty five 3D volumes were randomly selected from a larger prospective cohort study that studied the diagnostic accuracy of 3D GIS in addition to 2D GIS. To study interobserver agreement volumes were reviewed by two independent examiners. One examiner reviewed these samples twice with an interval of 1 month in a random order. Interobserver and intraobserver agreement were tested with Cohen's kappa coefficient and shown in Bland and Altman plots. Quality of the 3D volumes was evaluated.

RESULTS:

Cohen's kappa for interobserver variability for type of abnormalities (none, polyp, fibroid, other) was 0.64 and for presence of a fibroid (fibroid yes/no) 0.77. Agreement on type of fibroid was 0.59. Intraobserver agreement was almost perfect for type of abnormality (Cohen's kappa of 1.0) and good for fibroid diameter. Quality of the 3D volumes was poor in 11 out of 45 cases. Reproducibility increased when poor quality images were excluded.

CONCLUSION:

Substantial interobserver and intraobserver agreement for 3D GIS in the diagnoses of intrauterine abnormalities was found. 3D GIS interobserver and intraobserver agreement are good for fibroid diameter and moderate for volume and protrusion.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Pólipos / Neoplasias Uterinas / Leiomioma Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Adult / Female / Humans / Middle aged Idioma: En Revista: Eur J Obstet Gynecol Reprod Biol Año: 2014 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Pólipos / Neoplasias Uterinas / Leiomioma Tipo de estudio: Diagnostic_studies / Observational_studies Límite: Adult / Female / Humans / Middle aged Idioma: En Revista: Eur J Obstet Gynecol Reprod Biol Año: 2014 Tipo del documento: Article