One-year outcomes in unselected patients treated with a thin-strut, platinum-chromium, paclitaxel-eluting stent: primary endpoint results from the TAXUS Element European post-approval surveillance study (TE-PROVE).
EuroIntervention
; 10(11): 1261-6, 2015 Mar.
Article
en En
| MEDLINE
| ID: mdl-25572023
AIMS: To evaluate clinical outcomes in patients receiving the next-generation, paclitaxel-eluting, platinum-chromium TAXUS Element stent in a real-world setting. The PERSEUS Workhorse and Small Vessel studies showed positive results with the TAXUS Element stent in a clinical trial setting. METHODS AND RESULTS: TE-PROVE was a prospective, open-label, multicentre, "all-comers" study which enrolled 1,014 patients at 37 European sites. Follow-up was at 30 days, six months and one year, and will continue annually up to five years. The primary endpoint was overall and stent-related target vessel failure (TVF), defined as cardiac death, target vessel-related myocardial infarction (MI) and target vessel revascularisation (TVR) at one year post implantation. Secondary endpoints included the components of TVF, all-cause mortality, and ARC definite/probable stent thrombosis. Follow-up was available in 97.3% (987/1,014) of patients. Patients were 75.0% male (760/1,014), mean age was 65.1±10.8 years, 25.5% had medically treated diabetes (259/1,014), and 10.7% (109/1,014) were treated for STEMI. At baseline, mean lesion length among 1,299 treated lesions was 19.8±12.0 mm and mean reference vessel diameter was 3.1±0.5 mm. At one year, the rate of TVF (primary endpoint) was 6.0% (59/987) overall; 3.7% (37/987) of TVF events were stent-related. Cardiac death was 0.7% (7/987), target vessel-related MI was 1.1% (11/987), and TVR was 4.7% (46/987). All-cause death occurred in 1.2% (12/987) of patients and ARC definite/probable ST was 0.5% (5/987). CONCLUSIONS: The primary endpoint results from the TE-PROVE registry demonstrate good performance and safety for the TAXUS Element paclitaxel-eluting stent at one year in everyday clinical practice. CLINICAL TRIAL REGISTRATION INFORMATION: NCT01242696.
Texto completo:
1
Bases de datos:
MEDLINE
Asunto principal:
Platino (Metal)
/
Cromo
/
Paclitaxel
/
Estenosis Coronaria
/
Moduladores de Tubulina
/
Stents Liberadores de Fármacos
/
Infarto del Miocardio
Tipo de estudio:
Clinical_trials
/
Observational_studies
/
Risk_factors_studies
/
Screening_studies
Límite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
País/Región como asunto:
Europa
Idioma:
En
Revista:
EuroIntervention
Asunto de la revista:
ANGIOLOGIA
/
CARDIOLOGIA
/
TERAPEUTICA
Año:
2015
Tipo del documento:
Article
País de afiliación:
Italia