Comparison of multislice computed tomography findings between bicuspid and tricuspid aortic valves before and after transcatheter aortic valve implantation.
Watanabe, Yusuke; Chevalier, Bernard; Hayashida, Kentaro; Leong, Tora; Bouvier, Erik; Arai, Takahide; Farge, Arnaud; Hovasse, Thomas; Garot, Philippe; Cormier, Bertrand; Morice, Marie-Claude; Lefèvre, Thierry.
Afiliación
  • Watanabe Y; Division of Cardiology, Department of Internal Medicine, Teikyo University School of Medicine, Tokyo, Japan.
  • Chevalier B; Department of Cardiology and Cardiovascular Surgery, Institut Cardiovasculaire Paris Sud, Massy, France.
  • Hayashida K; Department of Cardiology and Cardiovascular Surgery, Institut Cardiovasculaire Paris Sud, Massy, France.
  • Leong T; Department of Cardiology, Keio University School of Medicine, Tokyo, Japan.
  • Bouvier E; Department of Cardiology and Cardiovascular Surgery, Institut Cardiovasculaire Paris Sud, Massy, France.
  • Arai T; Department of Cardiology and Cardiovascular Surgery, Institut Cardiovasculaire Paris Sud, Massy, France.
  • Farge A; Department of Cardiology and Cardiovascular Surgery, Institut Cardiovasculaire Paris Sud, Massy, France.
  • Hovasse T; Department of Cardiology and Cardiovascular Surgery, Institut Cardiovasculaire Paris Sud, Massy, France.
  • Garot P; Department of Cardiology and Cardiovascular Surgery, Institut Cardiovasculaire Paris Sud, Massy, France.
  • Cormier B; Department of Cardiology and Cardiovascular Surgery, Institut Cardiovasculaire Paris Sud, Massy, France.
  • Morice MC; Department of Cardiology and Cardiovascular Surgery, Institut Cardiovasculaire Paris Sud, Massy, France.
  • Lefèvre T; Department of Cardiology and Cardiovascular Surgery, Institut Cardiovasculaire Paris Sud, Massy, France.
Catheter Cardiovasc Interv ; 86(2): 323-30, 2015 Aug.
Article en En | MEDLINE | ID: mdl-25594190
ABSTRACT

AIMS:

This study sought to compare the multislice computed tomography (MSCT) characteristics of bicuspid aortic valves (BAV) and tricuspid aortic valves (TAV) before and after implantation of the CoreValve (Medtronic, Santa Rosa, California) or the Edwards SapienXT (Edwards Lifesciences, Irvine, CA). METHODS AND

RESULTS:

From March 2009 to March 2013, a total of 67 TAVI patients who had both pre- and post-procedural MSCT were studied. Eleven patients underwent TAVI in BAV with the CoreValve (n = 6) or SapienXT (n = 5) and 56 patients underwent TAVI in TAV with the CoreValve (n = 38) or SapienXT (n = 18). The BAV group was similar to the TAV group except for a higher pre-procedural mean pressure gradient (53.1 ± 17.4 vs. 48.8 ± 20.4 mm Hg, P = 0.03), a larger annulus perimeter (89.3 ± 9.0 vs. 81.8 ± 8.1 mm, P = 0.03) and a higher aortic valve calcium volume (1262.7 ± 396.0 vs. 556.4 ± 461.9 mm(3) , P < 0.01). In the CoreValve group, post-procedural mean pressure gradient was significantly higher in the BAV group (11.0 ± 2.6 vs. 8.2 ± 2.8 mm Hg, P = 0.04) and a smaller valve area/pre-annulus area ratio was observed at each level of the prosthesis (base of the stent frame 81.7% ± 14.9% vs. 94.7% ± 15.0%, P = 0.06, annulus level 74.3% ± 16.7% vs. 89.9% ± 10.5%, P = 0.03, leaflet level 64.6% ± 13.1% vs. 81.2% ± 13.2%, P < 0.01). This was not observed in the Edwards group.

CONCLUSIONS:

Compared to TAV, patients with BAV have higher gradients, larger annulus perimeters and more calcified valves. Higher post procedural gradient and valve underexpansion were frequently observed after CoreValve implantation. Further MSCT study is required to demonstrate the efficacy of TAVI in BAV.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Calcinosis / Cateterismo Cardíaco / Implantación de Prótesis de Válvulas Cardíacas / Tomografía Computarizada Multidetector / Enfermedades de las Válvulas Cardíacas Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2015 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Calcinosis / Cateterismo Cardíaco / Implantación de Prótesis de Válvulas Cardíacas / Tomografía Computarizada Multidetector / Enfermedades de las Válvulas Cardíacas Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Catheter Cardiovasc Interv Asunto de la revista: CARDIOLOGIA Año: 2015 Tipo del documento: Article País de afiliación: Japón