The extent of aortic annulus calcification is a predictor of postprocedural eccentricity and paravalvular regurgitation: a pre- and postinterventional cardiac computed tomography angiography study.
Bekeredjian, Raffi; Bodingbauer, Dorothea; Hofmann, Nina P; Greiner, Sebastian; Schuetz, Moritz; Geis, Nicolas A; Kauczor, Hans U; Bryant, Mark; Chorianopoulos, Emmanuel; Pleger, Sven T; Mereles, Derliz; Katus, Hugo A; Korosoglou, Grigorios.
Afiliación
  • Bekeredjian R; University of Heidelberg, Department of Cardiology, Im Neuenheimer Feld 410, Heidelberg, 69120, Germany. gkorosoglou@hotmail.com.
J Invasive Cardiol ; 27(3): 172-80, 2015 Mar.
Article en En | MEDLINE | ID: mdl-25740972
ABSTRACT

PURPOSE:

To investigate if the extent of aortic valve calcification is associated with postprocedural prosthesis eccentricity and paravalvular regurgitation (PAR) in patients undergoing transcatheter aortic valve implantation (TAVI).

METHODS:

Cardiac computed tomography angiography (CCTA) was performed before and 3 months after TAVI in 46 patients who received the self-expanding CoreValve and in 22 patients who underwent balloon-expandable Edwards Sapien XT implantation. Aortic annulus calcification was measured with CCTA prior to TAVI and prosthesis eccentricity was assessed with post-TAVI CCTA. Standard echocardiography was also performed in all patients at 3-month follow-up exam.

RESULTS:

Annulus eccentricity was reduced during TAVI using both implantation systems (from 0.23 ± 0.06 to 0.18 ± 0.07 using CoreValve and from 0.20 ± 0.07 to 0.05 ± 0.03 using Edwards Sapien XT; P<.001 for both). With Edwards Sapien XT, eccentricity reduction at the level of the aortic annulus was significantly higher compared with CoreValve (P<.001). Annulus eccentricity after CoreValve use was significantly related to absolute valve calcification and to valve calcification indexed to body surface area (BSA) (r = 0.48 and 0.50, respectively; P<.001 for both). Furthermore, a significant association was observed between aortic valve calcification and PAR (P<.01 by ANOVA) in patients who received CoreValve. Using ROC analysis, a cut-off value over 913 mm² aortic valve calcification predicted the occurrence of moderate or severe PAR with a sensitivity of 92% and a specificity of 63% (area under the curve = 0.75). Furthermore, multivariable analysis showed that aortic valve calcification was a robust predictor of postprocedural eccentricity and PAR, independent of the aortic annulus size and native valve eccentricity and of CoreValve prosthesis size (adjusted r = 0.46 and 0.50, respectively; P<.01 for both). Such associations were not present with the Edwards Sapien XT system.

CONCLUSION:

The extent of native aortic annulus calcification is predictive for postprocedural prosthesis eccentricity and PAR, which is an important marker for long-term mortality in patients undergoing TAVI. This observation applies for the CoreValve, but not for the Edwards Sapien XT valve.
Asunto(s)
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Válvula Aórtica / Insuficiencia de la Válvula Aórtica / Estenosis de la Válvula Aórtica / Calcinosis / Prótesis Valvulares Cardíacas / Tomografía Computarizada Multidetector / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Aged80 / Female / Humans / Male Idioma: En Revista: J Invasive Cardiol Asunto de la revista: CARDIOLOGIA Año: 2015 Tipo del documento: Article País de afiliación: Alemania
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Válvula Aórtica / Insuficiencia de la Válvula Aórtica / Estenosis de la Válvula Aórtica / Calcinosis / Prótesis Valvulares Cardíacas / Tomografía Computarizada Multidetector / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Aged80 / Female / Humans / Male Idioma: En Revista: J Invasive Cardiol Asunto de la revista: CARDIOLOGIA Año: 2015 Tipo del documento: Article País de afiliación: Alemania