Your browser doesn't support javascript.
loading
Early and Late Outcomes of Aortic Valve Replacement with Aortic Annular Enlargement: A Propensity Analysis.
Okamoto, Yuki; Yamamoto, Kazuo; Sugimoto, Tsutomu; Yoshii, Shinpei.
Afiliación
  • Okamoto Y; Department of Cardiovascular Surgery, Tachikawa Medical Center, Nagaoka City, Niigata, Japan.
  • Yamamoto K; Department of Cardiovascular Surgery, Tachikawa Medical Center, Nagaoka City, Niigata, Japan.
  • Sugimoto T; Department of Cardiovascular Surgery, Tachikawa Medical Center, Nagaoka City, Niigata, Japan.
  • Yoshii S; Department of Cardiovascular Surgery, Tachikawa Medical Center, Nagaoka City, Niigata, Japan.
Thorac Cardiovasc Surg ; 64(5): 410-7, 2016 Aug.
Article en En | MEDLINE | ID: mdl-26334242
ABSTRACT
Objectives Early and late outcomes were evaluated in Japanese patients undergoing aortic valve replacement (AVR) with or without aortic annular enlargement (AAE). Propensity matching adjusted for baseline differences in this study. Methods Between January 2001 and July 2014, 589 patients underwent AVR for aortic stenosis. Of these, 58 patients received AVR with AAE (AAE group), and the others received standard AVR without annular enlargement (sAVR group). Of these 589 patients, 116 patients were selected using propensity score matching analysis. We compared early and late outcomes between the two groups. Results Compared with the sAVR group, cardiopulmonary bypass time (177 ± 42 vs. 157 ± 39 minutes) and aortic cross-clamp time (126 ± 32 vs. 110 ± 34 minutes) were significantly longer in the AAE group. However, there were no significant differences between the AAE group and the sAVR group in 30-day mortality (1.7 vs. 3.4%) and in-hospital mortality (1.7 vs. 3.4%). There was no severe patient-prosthesis mismatch after AVR in the AAE group. The overall survival rate and freedom from cardiac events in the AAE group and in the sAVR group at 10 years were 92.4 versus 75.9% (p = 0.477) and 89.5 versus 82.8% (p = 0.076), respectively. No differences were found between the two groups. Conclusions AAE was performed safely in Japanese patients with small aortic annulus. Surgical outcomes of the AAE group were not inferior to those of sAVR. Using this technique, which did not require advanced skills, it was easy to avoid severe patient-prosthesis mismatch.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Implantación de Prótesis de Válvulas Cardíacas Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: Thorac Cardiovasc Surg Año: 2016 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Implantación de Prótesis de Válvulas Cardíacas Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Región como asunto: Asia Idioma: En Revista: Thorac Cardiovasc Surg Año: 2016 Tipo del documento: Article País de afiliación: Japón