Your browser doesn't support javascript.
loading
Three-dimensional whole-heart vs. two-dimensional high-resolution perfusion-CMR: a pilot study comparing myocardial ischaemic burden.
McDiarmid, Adam K; Ripley, David P; Mohee, Kevin; Kozerke, Sebastian; Greenwood, John P; Plein, Sven; Motwani, Manish.
Afiliación
  • McDiarmid AK; Division of Cardiovascular and Diabetes Research, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.
  • Ripley DP; Division of Cardiovascular and Diabetes Research, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.
  • Mohee K; Division of Cardiovascular and Diabetes Research, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.
  • Kozerke S; Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland.
  • Greenwood JP; Division of Cardiovascular and Diabetes Research, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.
  • Plein S; Division of Cardiovascular and Diabetes Research, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.
  • Motwani M; Division of Cardiovascular and Diabetes Research, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK m.motwani@leeds.ac.uk.
Eur Heart J Cardiovasc Imaging ; 17(8): 900-8, 2016 Aug.
Article en En | MEDLINE | ID: mdl-26450417
AIMS: Typically, myocardial perfusion imaging with two-dimensional (2D) cardiovascular magnetic resonance (CMR) acquires data in three to four myocardial slices at a spatial resolution of 2-3 mm. However, accelerated data acquisition can facilitate higher spatial resolution (<2 mm) or three-dimensional (3D) whole-heart coverage (up to 16 slices). This study aims to compare image quality, diagnostic confidence, and quantitation of myocardial ischaemic burden (MIB) between 2D high-resolution and 3D whole-heart perfusion-CMR. METHODS AND RESULTS: Twenty-seven patients with stable angina underwent both high-resolution 2D and whole-heart 3D perfusion-CMR. Total perfusion defect (TPD) and total scar burden (TSB) areas were contoured and expressed as percentage myocardium. MIB was calculated by subtracting TSB from TPD. Image quality, artefact, and diagnostic confidence scores were similar for both techniques (P>0.05). The mean MIB from high-resolution and 3D acquisition was similar (4.3±5.2% vs. 4.1±4.9%; P=0.81), with a strong correlation between techniques (r=0.72; P<0.001). There was no systematic bias for estimates of MIB between techniques [mean bias=-0.17%, 95% confidence interval (CI): -1.7 to -1.3%] and the 95% limits of agreement were -7.5 to 7.2%. When used to categorize MIB as >10% or <10%, there was only fair agreement between the two techniques (κ=0.29, 95% CI: -0.12 to 0.70). CONCLUSION: There is strong correlation and broad agreement between estimates of MIB from both techniques. However, the 95% limits of agreement are relatively wide and therefore a larger comparative study is needed before they can be considered interchangeable-particularly around the clinically relevant 10% threshold.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Isquemia Miocárdica / Imagen por Resonancia Cinemagnética / Imagenología Tridimensional / Imagen de Perfusión Miocárdica Tipo de estudio: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Heart J Cardiovasc Imaging Año: 2016 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Isquemia Miocárdica / Imagen por Resonancia Cinemagnética / Imagenología Tridimensional / Imagen de Perfusión Miocárdica Tipo de estudio: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Heart J Cardiovasc Imaging Año: 2016 Tipo del documento: Article