Your browser doesn't support javascript.
loading
Gas chromatography/atmospheric pressure chemical ionization/mass spectrometry for the analysis of organochlorine pesticides and polychlorinated biphenyls in human serum.
Geng, Dawei; Jogsten, Ingrid Ericson; Dunstan, Jody; Hagberg, Jessika; Wang, Thanh; Ruzzin, Jerome; Rabasa-Lhoret, Rémi; van Bavel, Bert.
Afiliación
  • Geng D; MTM Research Centre, School of Science and Technology, Örebro University, SE-701 82 Örebro, Sweden. Electronic address: dawei.geng@oru.se.
  • Jogsten IE; MTM Research Centre, School of Science and Technology, Örebro University, SE-701 82 Örebro, Sweden.
  • Dunstan J; Waters Corporation, Manchester, United Kingdom.
  • Hagberg J; MTM Research Centre, School of Science and Technology, Örebro University, SE-701 82 Örebro, Sweden; Department of Occupational and Environmental Medicine, Faculty of Medicine and Health, Örebro University, SE 70182 Örebro, Sweden.
  • Wang T; MTM Research Centre, School of Science and Technology, Örebro University, SE-701 82 Örebro, Sweden.
  • Ruzzin J; Department of Biology, University of Bergen, Norway.
  • Rabasa-Lhoret R; Institut de Recherches Cliniques de Montréal, Montréal, Québec, H2W 1R7, Canada; Montreal Diabetes Research Centre at the Centre de Recherche du Centre Hospitalier de l'Université de Montréal (CRCHUM) Montréal, Québec, H1W 4A4, Canada; Nutrition Department of Université de Montréal, Montréal, Québec
  • van Bavel B; MTM Research Centre, School of Science and Technology, Örebro University, SE-701 82 Örebro, Sweden; Norwegian Institute for Water Research, NIVA, Oslo, Norway.
J Chromatogr A ; 1453: 88-98, 2016 Jul 01.
Article en En | MEDLINE | ID: mdl-27236485
ABSTRACT
A method using a novel atmospheric pressure chemical ionization source for coupling gas chromatography (GC/APCI) to triple quadrupole mass spectrometry (MS/MS) for the determination of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) regulated by the Stockholm Convention is presented. One microliter injection of a six-point calibration curve of native PCBs and OCPs, ranging from 0.04 to 300pg/µL, was performed. The relative standard deviation (RSD) of the relative response factors (RRFs) was less than 15% with a coefficient of determination (r(2))>0.995. Meanwhile, two calibration solutions (CS), CS 2 (0.4pg/µL) and CS 3 (4pg/µL) were analyzed to study the repeatability calculated for both area and RRFs. The RSD for RRF ranged from 3.1 to 16% and 3.6 to 5.5% for CS 2 and CS 3, respectively. The limits of detection (LOD) determined by peak-to-peak signal-to-noise ratio (S/N) of 3 were compared between the GC/APCI/MS/MS and a GC coupled to high resolution mass spectrometry (GC/HRMS) system. GC/APCI/MS/MS resulted in lower LOD for most of the compounds, except for PCB#74, cis-chlordane and trans-chlordane. GC/APCI/MS/MS and GC/HRMS were also compared by performing analysis on 75 human serum samples together with eight QA/QC serum samples. The comparison between GC/APCI/MS/MS system and GC/HRMS system for 16 of the targeted compounds was carried out. No statistically significant difference was discovered. Due to increased sensitivity and user friendly operation under atmospheric pressure, GC/APCI/MS/MS is a powerful alternative technique that can easily meet the specification of GC/HRMS.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Plaguicidas / Bifenilos Policlorados / Espectrometría de Masas en Tándem / Hidrocarburos Clorados / Cromatografía de Gases y Espectrometría de Masas Límite: Humans Idioma: En Revista: J Chromatogr A Año: 2016 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Plaguicidas / Bifenilos Policlorados / Espectrometría de Masas en Tándem / Hidrocarburos Clorados / Cromatografía de Gases y Espectrometría de Masas Límite: Humans Idioma: En Revista: J Chromatogr A Año: 2016 Tipo del documento: Article