Improving Kinematic Accuracy of Soft Wearable Data Gloves by Optimizing Sensor Locations.
Kim, Dong Hyun; Lee, Sang Wook; Park, Hyung-Soon.
Afiliación
  • Kim DH; Mechanical Engineering Department, Korea Advanced Institute of Science and Technology, Daejeon 34141, Korea. bomdon@kaist.ac.kr.
  • Lee SW; Department of Biomedical Engineering, Catholic University of America, Washington, DC 20064, USA. leeb@cua.edu.
  • Park HS; Center for Applied Biomechanics and Rehabilitation Research, MedStar National Rehabilitation Hospital, Washington, DC 20010, USA. leeb@cua.edu.
Sensors (Basel) ; 16(6)2016 May 26.
Article en En | MEDLINE | ID: mdl-27240364
ABSTRACT
Bending sensors enable compact, wearable designs when used for measuring hand configurations in data gloves. While existing data gloves can accurately measure angular displacement of the finger and distal thumb joints, accurate measurement of thumb carpometacarpal (CMC) joint movements remains challenging due to crosstalk between the multi-sensor outputs required to measure the degrees of freedom (DOF). To properly measure CMC-joint configurations, sensor locations that minimize sensor crosstalk must be identified. This paper presents a novel approach to identifying optimal sensor locations. Three-dimensional hand surface data from ten subjects was collected in multiple thumb postures with varied CMC-joint flexion and abduction angles. For each posture, scanned CMC-joint contours were used to estimate CMC-joint flexion and abduction angles by varying the positions and orientations of two bending sensors. Optimal sensor locations were estimated by the least squares method, which minimized the difference between the true CMC-joint angles and the joint angle estimates. Finally, the resultant optimal sensor locations were experimentally validated. Placing sensors at the optimal locations, CMC-joint angle measurement accuracies improved (flexion, 2.8° ± 1.9°; abduction, 1.9° ± 1.2°). The proposed method for improving the accuracy of the sensing system can be extended to other types of soft wearable measurement devices.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Dispositivos Electrónicos Vestibles Límite: Humans Idioma: En Revista: Sensors (Basel) Año: 2016 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Dispositivos Electrónicos Vestibles Límite: Humans Idioma: En Revista: Sensors (Basel) Año: 2016 Tipo del documento: Article