Your browser doesn't support javascript.
loading
Functionalizing Arrays of Transferred Monolayer Graphene on Insulating Surfaces by Bipolar Electrochemistry.
Koefoed, Line; Pedersen, Emil Bjerglund; Thyssen, Lena; Vinther, Jesper; Kristiansen, Thomas; Pedersen, Steen U; Daasbjerg, Kim.
Afiliación
  • Koefoed L; Department of Chemistry, Aarhus University , Langelandsgade 140, 8000 Aarhus C, Denmark.
  • Pedersen EB; Interdisciplinary Nanoscience Center (iNANO), Aarhus University , Gustav Wieds Vej 14, 8000 Aarhus C, Denmark.
  • Thyssen L; Department of Chemistry, Aarhus University , Langelandsgade 140, 8000 Aarhus C, Denmark.
  • Vinther J; Interdisciplinary Nanoscience Center (iNANO), Aarhus University , Gustav Wieds Vej 14, 8000 Aarhus C, Denmark.
  • Kristiansen T; Department of Chemistry, Aarhus University , Langelandsgade 140, 8000 Aarhus C, Denmark.
  • Pedersen SU; Interdisciplinary Nanoscience Center (iNANO), Aarhus University , Gustav Wieds Vej 14, 8000 Aarhus C, Denmark.
  • Daasbjerg K; Department of Chemistry, Aarhus University , Langelandsgade 140, 8000 Aarhus C, Denmark.
Langmuir ; 32(25): 6289-96, 2016 06 28.
Article en En | MEDLINE | ID: mdl-27299175
ABSTRACT
Development of versatile methods for graphene functionalization is necessary before use in applications such as composites or as catalyst support. In this study, bipolar electrochemistry is used as a wireless functionalization method to graft 4-bromobenzenediazonium on large (10 × 10 mm(2)) monolayer graphene sheets supported on SiO2. Using this technique, transferred graphene can be electrochemically functionalized without the need of a metal support or the deposition of physical contacts. X-ray photoelectron spectroscopy and Raman spectroscopy are used to map the chemical changes and modifications of graphene across the individual sheets. Interestingly, the defect density is similar between samples, independent of driving potential, whereas the grafting density is increased upon increasing the driving potential. It is observed that the 2D nature of the electrode influences the electrochemistry and stability of the electrode compared to conventional electrografting using a three-electrode setup. On one side, the graphene will be blocked by the attached organic film, but the conductivity is also altered upon functionalization, which makes the graphene electrode different from a normal metal electrode. Furthermore, it is shown that it is possible to simultaneously modify an array of many small graphene electrodes (1 × 1 mm(2)) on SiO2.

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Langmuir Asunto de la revista: QUIMICA Año: 2016 Tipo del documento: Article País de afiliación: Dinamarca

Texto completo: 1 Bases de datos: MEDLINE Idioma: En Revista: Langmuir Asunto de la revista: QUIMICA Año: 2016 Tipo del documento: Article País de afiliación: Dinamarca