Incorporating outlier detection and replacement into a non-parametric framework for movement and distortion correction of diffusion MR images.
Andersson, Jesper L R; Graham, Mark S; Zsoldos, Eniko; Sotiropoulos, Stamatios N.
Afiliación
  • Andersson JLR; FMRIB Centre, Oxford University, Oxford, United Kingdom. Electronic address: jesper.andersson@ndcn.ox.ac.uk.
  • Graham MS; Centre for Medical Image Computing & Department of Computer Science, University College London, London, United Kingdom.
  • Zsoldos E; Department of Psychiatry, Oxford University, Oxford, United Kingdom.
  • Sotiropoulos SN; FMRIB Centre, Oxford University, Oxford, United Kingdom.
Neuroimage ; 141: 556-572, 2016 Nov 01.
Article en En | MEDLINE | ID: mdl-27393418
ABSTRACT
Despite its great potential in studying brain anatomy and structure, diffusion magnetic resonance imaging (dMRI) is marred by artefacts more than any other commonly used MRI technique. In this paper we present a non-parametric framework for detecting and correcting dMRI outliers (signal loss) caused by subject motion. Signal loss (dropout) affecting a whole slice, or a large connected region of a slice, is frequently observed in diffusion weighted images, leading to a set of unusable measurements. This is caused by bulk (subject or physiological) motion during the diffusion encoding part of the imaging sequence. We suggest a method to detect slices affected by signal loss and replace them by a non-parametric prediction, in order to minimise their impact on subsequent analysis. The outlier detection and replacement, as well as correction of other dMRI distortions (susceptibility-induced distortions, eddy currents (EC) and subject motion) are performed within a single framework, allowing the use of an integrated approach for distortion correction. Highly realistic simulations have been used to evaluate the method with respect to its ability to detect outliers (types 1 and 2 errors), the impact of outliers on retrospective correction of movement and distortion and the impact on estimation of commonly used diffusion tensor metrics, such as fractional anisotropy (FA) and mean diffusivity (MD). Data from a large imaging project studying older adults (the Whitehall Imaging sub-study) was used to demonstrate the utility of the method when applied to datasets with severe subject movement. The results indicate high sensitivity and specificity for detecting outliers and that their deleterious effects on FA and MD can be almost completely corrected.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Algoritmos / Encéfalo / Reconocimiento de Normas Patrones Automatizadas / Interpretación de Imagen Asistida por Computador / Aumento de la Imagen / Artefactos / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Neuroimage Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2016 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Algoritmos / Encéfalo / Reconocimiento de Normas Patrones Automatizadas / Interpretación de Imagen Asistida por Computador / Aumento de la Imagen / Artefactos / Imagen de Difusión por Resonancia Magnética Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Neuroimage Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2016 Tipo del documento: Article