Your browser doesn't support javascript.
loading
The effects of residual pump blood on patient plasma free haemoglobin levels post cardiac surgery.
Schotola, H; Wetz, A J; Popov, A F; Bergmann, I; Danner, B C; Schöndube, F A; Bauer, M; Bräuer, A.
Afiliación
  • Schotola H; Anaesthetist, Department of Anaesthesiology, Georg-August-University Goettingen, Goettingen, Germany.
  • Wetz AJ; Anaesthetist, Department of Anaesthesiology, Georg-August-University Goettingen, Goettingen, Germany.
  • Popov AF; Cardiac Surgeon, Department of Cardiothoracic Transplantation and Mechanical Support, Brompton and Harefield Hospital, London, United Kingdom.
  • Bergmann I; Anaesthetist, Department of Anaesthesiology, Georg-August-University Goettingen, Goettingen, Germany.
  • Danner BC; Cardiac Surgeon, Department of Thoracic and Cardiovascular Surgery, Georg-August-University Goettingen, Goettingen, Germany.
  • Schöndube FA; Professor, Cardiac Surgeon, Department of Thoracic and Cardiovascular Surgery, Georg-August-University Goettingen, Goettingen, Germany.
  • Bauer M; Anaesthetist, Professor, Department of Anaesthesiology, Georg-August-University Goettingen, Goettingen, Germany.
  • Bräuer A; Anaesthetist, Professor, Department of Anaesthesiology, Georg-August-University Goettingen, Goettingen, Germany.
Anaesth Intensive Care ; 44(5): 587-92, 2016 09.
Article en En | MEDLINE | ID: mdl-27608341
ABSTRACT
At the end of cardiopulmonary bypass, there are invariably several hundred millilitres of residual pump blood in the reservoir, which can either be re-transfused or discarded. The objective of this prospective observational study was to investigate the quality of the residual pump blood, focusing on plasma free haemoglobin (pfHb) and blood cell counts. Fifty-one consecutive patients were included in the study. Forty-nine units of residual pump blood and 58 units of transfused red blood cell (RBC) concentrates were analysed. The mean preoperative pfHb of the patients was 0.057 ± 0.062 g/l, which increased gradually to 0.55 ± 0.36 g/l on arrival in the intensive care unit postoperatively. On the first postoperative day, the mean pfHb had returned to within the normal range. Our data showed that haemoglobin, haematocrit, and erythrocyte counts of residual pump blood were approximately 40% of the values in standardised RBC concentrates. Plasma free haemoglobin was significantly higher in residual pump blood compared to RBC concentrates, and nearly twice as high as the pfHb in patient blood samples taken contemporaneously. Our findings indicate that residual pump blood pfHb levels are markedly higher compared to patients' blood and RBC concentrates, but that its administration does not significantly increase patients' pfHb levels.
Asunto(s)
Palabras clave
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Hemoglobinas / Puente Cardiopulmonar / Procedimientos Quirúrgicos Cardíacos Tipo de estudio: Observational_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Anaesth Intensive Care Año: 2016 Tipo del documento: Article País de afiliación: Alemania
Buscar en Google
Bases de datos: MEDLINE Asunto principal: Hemoglobinas / Puente Cardiopulmonar / Procedimientos Quirúrgicos Cardíacos Tipo de estudio: Observational_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Anaesth Intensive Care Año: 2016 Tipo del documento: Article País de afiliación: Alemania