Assessment of contrast sensitivity loss after intrastromal femtosecond laser and LASIK procedure.
Mai, Elsa L C; Lian, Ie-Bin; Chang, David C K.
Afiliación
  • Mai EL; Far Eastern Memorial Hospital, Taipei 100, Taiwan, China.
  • Lian IB; National Changhua University of Education, Changhua 500, Taiwan, China.
  • Chang DC; Taiwan Nobel Eye Institute, Taipei 100, Taiwan, China.
Int J Ophthalmol ; 9(12): 1798-1801, 2016.
Article en En | MEDLINE | ID: mdl-28003982
AIM: To assess the loss of contrast sensitivity (CS) function for INTRACOR or intrastromal femtosecond laser presbyopia procedure to conventional LASIK procedures. METHODS: Patients were recruited from a refractive surgery center for either INTRACOR or conventional LASIK. INTRACOR was performed on 8 eyes and LASIK was performed for 40 eyes in an overlapping period. Pre-operative evaluation and post-operative follow up for up to three months was done. Drops of CS in 4 spatial frequency (3 cpd, 6 cpd, 12 cpd and 18 cpd) right before and 3mo after the surgery were compared by Wilcoxon signed ranks test. RESULTS: For INTRACOR, CS threshold showed significant drop at both glare and non-glare condition, the drop was seen in all 4 spatial frequency. The averaged loss over the 4 spatial frequencies 3mo after surgery was 1.18 for non-glare and 0.71 for glare. For LASIK the CS threshold drop was most significant in 12 cpd for glare. CONCLUSION: INTRACOR procedure produces a gain of near vision for presbyopia patients but also introduces a high lost of contrast sensitivity plus worsen of vision quality. Pre-surgical patient selection and advise should be given with specific regards to night driving and glare conditions.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Int J Ophthalmol Año: 2016 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Int J Ophthalmol Año: 2016 Tipo del documento: Article País de afiliación: China