Your browser doesn't support javascript.
loading
Using color flow detection of air insufflation to improve accuracy in verifying nasogastric tube position.
Wong, Kin Wa; Chan, Hok Hang; Wong, Chi Pang; Chan, Ming Yin; Chau, Jeffrey Cheuk Wai; Wong, Tai Wai.
Afiliación
  • Wong KW; Accident and Emergency Department, Tseung Kwan O Hospital, Hong Kong. Electronic address: kinwawong@gmail.com.
  • Chan HH; Accident and Emergency Department, Pamela Youde Nethersole Eastern Hospital, Hong Kong.
  • Wong CP; Accident and Emergency Department, Pamela Youde Nethersole Eastern Hospital, Hong Kong.
  • Chan MY; Accident and Emergency Department, Pamela Youde Nethersole Eastern Hospital, Hong Kong.
  • Chau JCW; Accident and Emergency Department, Pamela Youde Nethersole Eastern Hospital, Hong Kong.
  • Wong TW; Accident and Emergency Department, Pamela Youde Nethersole Eastern Hospital, Hong Kong.
Am J Emerg Med ; 35(2): 333-336, 2017 Feb.
Article en En | MEDLINE | ID: mdl-28038826
ABSTRACT

OBJECTIVES:

Previous studies have shown that ultrasonography (USG), as an alternative to radiography, has a good accuracy in confirming nasogastric tube (NGT) position. Color flow detection of air insufflation is a novel approach in verifying NGT position. In our study, we aimed at evaluating its sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy in confirming the NGT position, as compared with 2-dimensional (2D) USG.

METHODS:

The study was conducted on adult patients over a period of 38months in an emergency department in Hong Kong. 2D USG and color flow Doppler imaging were conducted for each subject. Chest X-ray was used as the gold standard for NGT position confirmation.

RESULTS:

100 patients (59 males and 41 females) were recruited totally. Their mean age was 82. The sensitivity, specificity, PPV and NPV of 2D USG were 11.1% (95% CI 4.6%-17.6%), 100% (95% CI 100%-100%), 100% (95% CI 100%-100%), and 11.1% (95% CI 4.6%-17.6%) respectively. For color flow Doppler USG, the sensitivity, specificity, PPV and NPV were 90% (95% CI 83.7%-96.2%), 80% (95% CI 55.2%-100%), 97.6% (95% CI 94.3%-100%), and 47.1% (95% CI 23.3%-70.8%) respectively. The overall accuracy of color Doppler imaging was 89%, which was higher than that of 2D USG (20% only).

CONCLUSIONS:

Color flow detection of air insufflation improves the diagnostic accuracy of ultrasound in verifying NGT position. It is a quick investigation such that fasting time of patients and their length of ED stay can be shortened.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Estómago / Insuflación / Radiografía Torácica / Ultrasonografía Doppler en Color / Errores Médicos / Intubación Gastrointestinal Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Aged / Aged80 / Female / Humans / Male País/Región como asunto: Asia Idioma: En Revista: Am J Emerg Med Año: 2017 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Estómago / Insuflación / Radiografía Torácica / Ultrasonografía Doppler en Color / Errores Médicos / Intubación Gastrointestinal Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Aged / Aged80 / Female / Humans / Male País/Región como asunto: Asia Idioma: En Revista: Am J Emerg Med Año: 2017 Tipo del documento: Article