Your browser doesn't support javascript.
loading
Comprehensive Assessment of Coronary Artery Disease by Using First-Pass Analysis Dynamic CT Perfusion: Validation in a Swine Model.
Hubbard, Logan; Lipinski, Jerry; Ziemer, Benjamin; Malkasian, Shant; Sadeghi, Bahman; Javan, Hanna; Groves, Elliott M; Dertli, Brian; Molloi, Sabee.
Afiliación
  • Hubbard L; From the Department of Radiological Sciences (L.H., J.L., B.Z., S. Malkasian, B.S., H.J., B.D., S. Molloi) and Division of Cardiology (E.M.G.), University of California, Irvine, Medical Sciences I, B-140, Irvine, CA 92697.
  • Lipinski J; From the Department of Radiological Sciences (L.H., J.L., B.Z., S. Malkasian, B.S., H.J., B.D., S. Molloi) and Division of Cardiology (E.M.G.), University of California, Irvine, Medical Sciences I, B-140, Irvine, CA 92697.
  • Ziemer B; From the Department of Radiological Sciences (L.H., J.L., B.Z., S. Malkasian, B.S., H.J., B.D., S. Molloi) and Division of Cardiology (E.M.G.), University of California, Irvine, Medical Sciences I, B-140, Irvine, CA 92697.
  • Malkasian S; From the Department of Radiological Sciences (L.H., J.L., B.Z., S. Malkasian, B.S., H.J., B.D., S. Molloi) and Division of Cardiology (E.M.G.), University of California, Irvine, Medical Sciences I, B-140, Irvine, CA 92697.
  • Sadeghi B; From the Department of Radiological Sciences (L.H., J.L., B.Z., S. Malkasian, B.S., H.J., B.D., S. Molloi) and Division of Cardiology (E.M.G.), University of California, Irvine, Medical Sciences I, B-140, Irvine, CA 92697.
  • Javan H; From the Department of Radiological Sciences (L.H., J.L., B.Z., S. Malkasian, B.S., H.J., B.D., S. Molloi) and Division of Cardiology (E.M.G.), University of California, Irvine, Medical Sciences I, B-140, Irvine, CA 92697.
  • Groves EM; From the Department of Radiological Sciences (L.H., J.L., B.Z., S. Malkasian, B.S., H.J., B.D., S. Molloi) and Division of Cardiology (E.M.G.), University of California, Irvine, Medical Sciences I, B-140, Irvine, CA 92697.
  • Dertli B; From the Department of Radiological Sciences (L.H., J.L., B.Z., S. Malkasian, B.S., H.J., B.D., S. Molloi) and Division of Cardiology (E.M.G.), University of California, Irvine, Medical Sciences I, B-140, Irvine, CA 92697.
  • Molloi S; From the Department of Radiological Sciences (L.H., J.L., B.Z., S. Malkasian, B.S., H.J., B.D., S. Molloi) and Division of Cardiology (E.M.G.), University of California, Irvine, Medical Sciences I, B-140, Irvine, CA 92697.
Radiology ; 286(1): 93-102, 2018 01.
Article en En | MEDLINE | ID: mdl-29059038
ABSTRACT
Purpose To retrospectively validate a first-pass analysis (FPA) technique that combines computed tomographic (CT) angiography and dynamic CT perfusion measurement into one low-dose examination. Materials and Methods The study was approved by the animal care committee. The FPA technique was retrospectively validated in six swine (mean weight, 37.3 kg ± 7.5 [standard deviation]) between April 2015 and October 2016. Four to five intermediate-severity stenoses were generated in the left anterior descending artery (LAD), and 20 contrast material-enhanced volume scans were acquired per stenosis. All volume scans were used for maximum slope model (MSM) perfusion measurement, but only two volume scans were used for FPA perfusion measurement. Perfusion measurements in the LAD, left circumflex artery (LCx), right coronary artery, and all three coronary arteries combined were compared with microsphere perfusion measurements by using regression, root-mean-square error, root-mean-square deviation, Lin concordance correlation, and diagnostic outcomes analysis. The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were also determined. Results FPA and MSM perfusion measurements (PFPA and PMSM) in all three coronary arteries combined were related to reference standard microsphere perfusion measurements (PMICRO), as follows PFPA_COMBINED = 1.02 PMICRO_COMBINED + 0.11 (r = 0.96) and PMSM_COMBINED = 0.28 PMICRO_COMBINED + 0.23 (r = 0.89). The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were 10.8 and 17.8 mGy, respectively. Conclusion The FPA technique was retrospectively validated in a swine model and has the potential to be used for accurate, low-dose vessel-specific morphologic and physiologic assessment of coronary artery disease. © RSNA, 2017.
Asunto(s)

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Interpretación de Imagen Asistida por Computador / Tomografía Computarizada por Rayos X / Imagen de Perfusión Miocárdica Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: Radiology Año: 2018 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Interpretación de Imagen Asistida por Computador / Tomografía Computarizada por Rayos X / Imagen de Perfusión Miocárdica Tipo de estudio: Prognostic_studies Límite: Animals Idioma: En Revista: Radiology Año: 2018 Tipo del documento: Article