Your browser doesn't support javascript.
loading
A flow injection procedure using Layered Double Hydroxide for on line pre-concentration of fluoride.
Rocha, Diego P; Anjos, Gabriel T C; Neri, Thais S; Tronto, Jairo; Pinto, Frederico G; Silva, Sidnei G; Coelho, Nívia M M.
Afiliación
  • Rocha DP; Federal University of Uberlândia, Institute of Chemistry, Avenue João Naves de Ávila, 2121, Santa Mônica, Uberlândia, MG CEP 38400-902, Brazil.
  • Anjos GTC; Federal University of Uberlândia, Institute of Chemistry, Avenue João Naves de Ávila, 2121, Santa Mônica, Uberlândia, MG CEP 38400-902, Brazil.
  • Neri TS; Federal University of Uberlândia, Institute of Chemistry, Avenue João Naves de Ávila, 2121, Santa Mônica, Uberlândia, MG CEP 38400-902, Brazil.
  • Tronto J; Federal University of Viçosa, Campus de Rio Paranaíba, Institute of Exact and Technological Sciences, Rodovia MG-230 - Km 8, Rio Paranaíba, MG CEP 38810-000, Brazil.
  • Pinto FG; Federal University of Viçosa, Campus de Rio Paranaíba, Institute of Exact and Technological Sciences, Rodovia MG-230 - Km 8, Rio Paranaíba, MG CEP 38810-000, Brazil.
  • Silva SG; Federal University of Uberlândia, Institute of Chemistry, Avenue João Naves de Ávila, 2121, Santa Mônica, Uberlândia, MG CEP 38400-902, Brazil.
  • Coelho NMM; Federal University of Uberlândia, Institute of Chemistry, Avenue João Naves de Ávila, 2121, Santa Mônica, Uberlândia, MG CEP 38400-902, Brazil. Electronic address: niviammcoelho@gmail.com.
Talanta ; 178: 102-108, 2018 Feb 01.
Article en En | MEDLINE | ID: mdl-29136791
ABSTRACT
This work showed a flow system designed with solenoid valves for preconcentration of fluoride using SPADNS method in water samples. The analyte was preconcentrated in a mini-column coated with Layered Double Hydroxides (LDH) used as adsorbent. Then, the fluoride ions were eluted with 0.5molL-1 sodium hydroxide and determined by spectrophotometry. The variables that affect the system such adsorbent mass, type of eluent, solutions flow rate, reagent concentration and pH effect were critically evaluated. Under optimized conditions, the detection limit, coefficient of variation, linear range and preconcentration factor were estimated at 15µgL-1 (99.7% confidence level), 0.8% (500µgL-1, n = 10), 50-500µgL-1 and 10, respectively. The accuracy of the method was evaluated by analysis of ALPHA APS 1076 (Simulated Rain Water) certified material, the values were not significantly different at a 95% level of confidence. The method was applied for fluoride determination in water samples and the levels found were below the maximum values established by Brazilian environmental and health legislations.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Análisis de Inyección de Flujo / Fluoruros / Hidróxidos Idioma: En Revista: Talanta Año: 2018 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Análisis de Inyección de Flujo / Fluoruros / Hidróxidos Idioma: En Revista: Talanta Año: 2018 Tipo del documento: Article País de afiliación: Brasil