Your browser doesn't support javascript.
loading
Reliability of a semi-automated algorithm for the vastus lateralis muscle architecture measurement based on ultrasound images.
Marzilger, Robert; Legerlotz, Kirsten; Panteli, Chrystalla; Bohm, Sebastian; Arampatzis, Adamantios.
Afiliación
  • Marzilger R; Department of Training and Movement Sciences, Humboldt-Universität zu Berlin, Philippstr. 13, Haus 11, 10115, Berlin, Germany.
  • Legerlotz K; Berlin School of Movement Sciences, Humboldt-Universität zu Berlin, Berlin, Germany.
  • Panteli C; Department of Training and Movement Sciences, Humboldt-Universität zu Berlin, Philippstr. 13, Haus 11, 10115, Berlin, Germany.
  • Bohm S; Berlin School of Movement Sciences, Humboldt-Universität zu Berlin, Berlin, Germany.
  • Arampatzis A; Department of Physical Education and Sport Science, Aristoteles University of Thessaloniki, Thessaloniki, Greece.
Eur J Appl Physiol ; 118(2): 291-301, 2018 Feb.
Article en En | MEDLINE | ID: mdl-29214464
ABSTRACT

PURPOSE:

The assessment of muscle architecture with B-mode ultrasound is an established method in muscle physiology and mechanics. There are several manual, semi-automated and automated approaches available for muscle architecture analysis from ultrasound images or videos. However, most approaches have limitations such as workload, subjectivity, drift or they are applicable to short muscle fascicles only. Addressing these issues, an algorithm was developed to analyse architectural parameters of the vastus lateralis muscle (VL).

METHODS:

In 17 healthy young men and women, ultrasound images were taken five times on two different days during passive knee joint flexion. From the images, fascicle length (FL), pennation angle (PAN) and muscle thickness (MTH) were calculated for both test days using the algorithm. Interday differences were determined using a two-way ANOVA. Interday and intraday reliability were assessed using intraclass correlation coefficients (ICC) and root mean square (RMS) differences.

RESULTS:

FL, MTH and PAN did not differ between day one and two. The within day ICCs were above 0.94 for all tested parameters. The average interday ICCs were 0.86 for the FL, 0.96 for MTH and 0.60 for PAN. The average RMS differences between both days were 5.0%, 8.5% and 12.0% for MTH, FL and PAN, respectively.

CONCLUSION:

The proposed algorithm provides high measurement reliability. However, the interday reliability might be influenced by small differences in probe position between days.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Ultrasonografía / Músculo Cuádriceps Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prognostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Eur J Appl Physiol Asunto de la revista: FISIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Ultrasonografía / Músculo Cuádriceps Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prognostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Eur J Appl Physiol Asunto de la revista: FISIOLOGIA Año: 2018 Tipo del documento: Article País de afiliación: Alemania