Your browser doesn't support javascript.
loading
Sliding hip screw versus cannulated cancellous screws for fixation of femoral neck fracture in adults: A systematic review.
Ma, Jian-Xiong; Kuang, Ming-Jie; Xing, Fei; Zhao, Yun-Long; Chen, Heng-Ting; Zhang, Lu-Kai; Fan, Zheng-Rui; Han, Chao; Ma, Xin-Long.
Afiliación
  • Ma JX; Biomechanics Labs of Orthopaedics Institute, Tianjin Hospital, Tianjin, 300050, People's Republic of China; Tianjin Hospital, Tianjin University, Tianjin, 300211, People's Republic of China. Electronic address: mjx969@163.com.
  • Kuang MJ; Biomechanics Labs of Orthopaedics Institute, Tianjin Hospital, Tianjin, 300050, People's Republic of China; Tianjin Hospital, Tianjin University, Tianjin, 300211, People's Republic of China; Tianjin Medical University, Tianjin, 300070, People's Republic of China. Electronic address: doctorkmj@tmu.ed
  • Xing F; Biomechanics Labs of Orthopaedics Institute, Tianjin Hospital, Tianjin, 300050, People's Republic of China; Tianjin Medical University, Tianjin, 300070, People's Republic of China. Electronic address: lisomox@outlook.com.
  • Zhao YL; Biomechanics Labs of Orthopaedics Institute, Tianjin Hospital, Tianjin, 300050, People's Republic of China; Tianjin Hospital, Tianjin University, Tianjin, 300211, People's Republic of China; Tianjin Medical University, Tianjin, 300070, People's Republic of China. Electronic address: zandom@126.com.
  • Chen HT; Biomechanics Labs of Orthopaedics Institute, Tianjin Hospital, Tianjin, 300050, People's Republic of China; Tianjin Medical University, Tianjin, 300070, People's Republic of China. Electronic address: 1192602465@qq.com.
  • Zhang LK; Biomechanics Labs of Orthopaedics Institute, Tianjin Hospital, Tianjin, 300050, People's Republic of China; Tianjin Hospital, Tianjin University, Tianjin, 300211, People's Republic of China. Electronic address: 13820852131@sina.cn.
  • Fan ZR; Biomechanics Labs of Orthopaedics Institute, Tianjin Hospital, Tianjin, 300050, People's Republic of China; Tianjin Hospital, Tianjin University, Tianjin, 300211, People's Republic of China. Electronic address: 517494450@qq.com.
  • Han C; Biomechanics Labs of Orthopaedics Institute, Tianjin Hospital, Tianjin, 300050, People's Republic of China; Tianjin Hospital, Tianjin University, Tianjin, 300211, People's Republic of China. Electronic address: craborth@163.com.
  • Ma XL; Biomechanics Labs of Orthopaedics Institute, Tianjin Hospital, Tianjin, 300050, People's Republic of China; Tianjin Hospital, Tianjin University, Tianjin, 300211, People's Republic of China. Electronic address: maxinlong8686@126.com.
Int J Surg ; 52: 89-97, 2018 Apr.
Article en En | MEDLINE | ID: mdl-29471156
ABSTRACT

OBJECTIVE:

Femoral neck fracture is considered a difficult fracture to treat and often gives rise to unsatisfactory treatment results. Cannulated cancellous screws (CCS) or a sliding hip screw (SHS) are the mainstream internal fixations used for osteosynthesis of femoral neck fractures. There is a need to integrate existing data through a meta-analysis to investigate the safety and effectiveness of CCS and SHS in the treatment of femoral neck fractures.

METHOD:

According to the Cochrane Handbook for Systematic Reviews of Interventions, we screened for the relevant studies by searching Google Scholar, the Cochrane Controlled Trials Register, the Cochrane Library, Web of Science, EMBASE, and PubMed. The PICOS criteria was used to make sure the included studies fulfilled the inclusion criteria.

RESULTS:

Pooled data showed that there were no significant differences between the SHS and CCS groups for the Harris Hip Score. Significant differences were found between the SHS and CCS groups in terms of union time, postoperative complications, blood loss, operation time, incision length and length of hospital stay.

CONCLUSIONS:

Although the SHS and CCS groups showed similar functional recovery in treatment of femoral neck fracture in terms of the Harris Hip Score, the SHS group showed fewer postoperative complications and faster union time for patients with femoral neck fractures. Therefore, compared with CCS, the use of SHS may be a more effective treatment of femoral neck fractures.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tornillos Óseos / Fracturas del Cuello Femoral / Fijación Interna de Fracturas Tipo de estudio: Etiology_studies / Systematic_reviews Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Surg Año: 2018 Tipo del documento: Article

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Tornillos Óseos / Fracturas del Cuello Femoral / Fijación Interna de Fracturas Tipo de estudio: Etiology_studies / Systematic_reviews Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Surg Año: 2018 Tipo del documento: Article