Your browser doesn't support javascript.
loading
Evaluation of the Luminex xTAG Respiratory Viral Panel FAST v2 assay for detection of multiple respiratory viral pathogens in nasal and throat swabs in Vietnam.
Thi Ty Hang, Vu; Thi Han Ny, Nguyen; My Phuc, Tran; Thi Thanh Tam, Pham; Thao Huong, Dang; Dang Trung Nghia, Ho; Tran Anh Vu, Nguyen; Thi Hong Phuong, Pham; Van Xang, Nguyen; Dong, Nguyen; Nhu Hiep, Pham; Van Hung, Nguyen; Tinh Hien, Tran; Rabaa, Maia; Thwaites, Guy E; Baker, Stephen; Van Tan, Le; van Doorn, H Rogier.
Afiliación
  • Thi Ty Hang V; Hospital for Tropical Diseases, Wellcome Trust Major Overseas Programme, Oxford University Clinical Research Unit, Ho Chi Minh City, Vietnam.
  • Thi Han Ny N; Hospital for Tropical Diseases, Wellcome Trust Major Overseas Programme, Oxford University Clinical Research Unit, Ho Chi Minh City, Vietnam.
  • My Phuc T; Hospital for Tropical Diseases, Wellcome Trust Major Overseas Programme, Oxford University Clinical Research Unit, Ho Chi Minh City, Vietnam.
  • Thi Thanh Tam P; Hospital for Tropical Diseases, Wellcome Trust Major Overseas Programme, Oxford University Clinical Research Unit, Ho Chi Minh City, Vietnam.
  • Thao Huong D; Hospital for Tropical Diseases, Wellcome Trust Major Overseas Programme, Oxford University Clinical Research Unit, Ho Chi Minh City, Vietnam.
  • Dang Trung Nghia H; Hospital for Tropical Diseases, Wellcome Trust Major Overseas Programme, Oxford University Clinical Research Unit, Ho Chi Minh City, Vietnam.
  • Tran Anh Vu N; Dong Thap General Hospital, Dong Thap, Vietnam.
  • Thi Hong Phuong P; Dong Thap General Hospital, Dong Thap, Vietnam.
  • Van Xang N; Khanh Hoa General Hospital, Khanh Hoa, Vietnam.
  • Dong N; Khanh Hoa General Hospital, Khanh Hoa, Vietnam.
  • Nhu Hiep P; Hue Central Hospital, Thua Thien - Hue, Vietnam.
  • Van Hung N; Dak Lak General Hospital, Dak Lak, Vietnam.
  • Tinh Hien T; Hospital for Tropical Diseases, Wellcome Trust Major Overseas Programme, Oxford University Clinical Research Unit, Ho Chi Minh City, Vietnam.
  • Rabaa M; Centre for Tropical Medicine, Nuffield Department of Clinical Medicine, Oxford University, Oxford, UK.
  • Thwaites GE; Hospital for Tropical Diseases, Wellcome Trust Major Overseas Programme, Oxford University Clinical Research Unit, Ho Chi Minh City, Vietnam.
  • Baker S; Hospital for Tropical Diseases, Wellcome Trust Major Overseas Programme, Oxford University Clinical Research Unit, Ho Chi Minh City, Vietnam.
  • Van Tan L; Centre for Tropical Medicine, Nuffield Department of Clinical Medicine, Oxford University, Oxford, UK.
  • van Doorn HR; Hospital for Tropical Diseases, Wellcome Trust Major Overseas Programme, Oxford University Clinical Research Unit, Ho Chi Minh City, Vietnam.
Wellcome Open Res ; 2: 80, 2017.
Article en En | MEDLINE | ID: mdl-29503874
ABSTRACT

BACKGROUND:

Acute respiratory infections (ARI) are among the leading causes of hospitalization in children ≤5 years old. Rapid diagnostics of viral pathogens is essential to avoid unnecessary antibiotic treatment, thereby slowing down antibiotic-resistance. We evaluated the diagnostic performance of the Luminex xTAG Respiratory Viral Panel FAST v2 against viral specific PCR as reference assays for ARI in Vietnam.

METHODS:

Four hundred and forty two nose and throat swabs were collected in viral transport medium, and were tested with Luminex xTAG Respiratory Viral Panel FAST v2. Multiplex RT-PCR and single RT-PCR were used as references.   

Results:

Overall, viral pathogens were detected in a total count of 270/294 (91.8%, 95% CI 88.1-94.7) by the Luminex among reference assays, whilst 112/6336 (1.8%, 95% CI, 1.4-2.1) of pathogens were detected by the Luminex, but not by reference assays. Frequency of pathogens detected by Luminex and reference assays was 379 and 292, respectively. The diagnostic yield was 66.7% (295/442, 95%CI 62.1-71.1%) for the Luminex assay and 54.1% (239/442, 95% CI, 49.3-58.8%) for reference assays. The Luminex kit had higher yields for all viruses except influenza B virus, respiratory syncytial virus, and human bocavirus. High agreements between both methods [mean (range) 0.91 (0.83-1.00)] were found for 10/15 viral agents.

CONCLUSIONS:

The Luminex assay is a high throughput multiplex platform for rapid detection of common viral pathogens causing ARI. Although the current high cost may prevent Luminex assays from being widely used, especially in limited resource settings where ARI are felt most, its introduction in clinical diagnostics may help reduce unnecessary use of antibiotic prescription.
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Wellcome Open Res Año: 2017 Tipo del documento: Article País de afiliación: Vietnam

Texto completo: 1 Bases de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Wellcome Open Res Año: 2017 Tipo del documento: Article País de afiliación: Vietnam