Your browser doesn't support javascript.
loading
PVC membrane, coated-wire, and carbon-paste ion-selective electrodes for potentiometric determination of galantamine hydrobromide in physiological fluids.
Abdel-Haleem, Fatehy M; Saad, Mohamed; Barhoum, Ahmed; Bechelany, Mikhael; Rizk, Mahmoud S.
Afiliación
  • Abdel-Haleem FM; Chemistry Department, Faculty of Science, Cairo University, Gamaa Street, Giza 12613, Egypt.
  • Saad M; Chemistry Department, Faculty of Science, Cairo University, Gamaa Street, Giza 12613, Egypt.
  • Barhoum A; Chemistry Department, Faculty of Science, Helwan University, Helwan, Cairo 11795, Egypt. Electronic address: ahmed.barhoum@science.helwan.edu.eg.
  • Bechelany M; Institut Européen des Membranes, UMR 5635, Université de Montpellier, CNRS, ENSCM, Place Eugène Bataillon, 34095 Montpellier Cedex 5, France.
  • Rizk MS; Chemistry Department, Faculty of Science, Cairo University, Gamaa Street, Giza 12613, Egypt.
Mater Sci Eng C Mater Biol Appl ; 89: 140-148, 2018 Aug 01.
Article en En | MEDLINE | ID: mdl-29752082
ABSTRACT
We report on highly-sensitive ion-selective electrodes (ISEs) for potentiometric determining of galantamine hydrobromide (GB) in physiological fluids. Galantamine hydrobromide (GB) was selected for this study due to its previous medical importance for treating Alzheimer's disease. Three different types of ISEs were investigated PVC membrane electrode (PVCE), carbon-paste electrode (CPE), and coated-wire electrode (CWE). In the construction of these electrodes, galantaminium-reineckate (GR) ion-pair was used as a sensing species for GB in solutions. The modified carbon-paste electrode (MCPE) was prepared using graphene oxide (MCPE-GO) and sodium tetrakis (trifluoromethyl) phenyl borate (MCPE-STFPB) as ion-exchanger. The potentiometric modified CPEs (MCPE-GO and MCPE-STFPB) show an improved performance in term of Nernstian slope, selectivity, response time, and response stability compared to the unmodified CPE. The prepared electrodes PVCE, CWE, CPE, MCPE-GO and MCPE-STFPB show Nernstian slopes of 59.9, 59.5, 58.1, 58.3 and 57.0 mV/conc. decade, and detection limits of 5.0 × 10-6, 6.3 × 10-6, 8.0 × 10-6, 6.0 × 10-6 and 8.0 × 10-6 mol L-1, respectively. The prepared ISEs also show high selectivity against cations (i.e. Na+, K+, NH4+, Ca2+, Al3+, Fe3+), amino acids (i.e. glycine, L-alanine alanine), and sugars (i.e. fructose, glucose, maltose, lactose). The prepared ISEs are applicable for determining GB in spiked serums, urines, and pharmaceutical preparations, using a standard addition and a direct potentiometric method. The fast response time (<10 s), long lifetime (1-5 weeks), reversibility and stability of the measured signals facilitate the application of these sensors for routine analysis of the real samples.
Asunto(s)
Palabras clave

Texto completo: 1 Bases de datos: MEDLINE Asunto principal: Cloruro de Polivinilo / Potenciometría / Carbono / Galantamina Idioma: En Revista: Mater Sci Eng C Mater Biol Appl Año: 2018 Tipo del documento: Article País de afiliación: Egipto